Model 43AP Pneumatic Controller, Style B



Similar documents
POWERS CONTROL RC 195 Single Input Receiver-Controller

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

RC 195 Multiple Input Receiver-Controller

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

T-4000 Series Room Thermostat Adjusting Instructions*

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

PNEUMATIC CONTROLS Selection and Description

Fuel Injection Pump, Rotary ( )

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

How To Replace A Reverse Osmosis Water Tank

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Your safety and the safety of others are very important.

STEERING SYSTEM - POWER

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Speed-Mat Rectangle Cutter

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Installation Instructions S

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

NITROUS TRANSFER PUMP INSTRUCTIONS

TS93 EMR T/PT/TDE. Surface applied door closer

POWERS Controls No. 4 Pneumatic Damper Actuator

General Information... 2

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Submersion/Insertion Toroidal Sensor

T and T Single Input Receiver-Controllers Installation and Calibration

SureSite Magnetic Liquid Level Indicator

2006 JUDY SERVICE GUIDE

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

8900 EMR (WITH DETECTOR)

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Reduced Pressure Principle Assembly 3 Valve Procedure

A-4000 Oil Indicator

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Fisher 657 and 667 Diaphragm Actuators

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Self Purging Liquid Trap (SPLT ) User s Manual

SELECTION, APPLICATION AND MAINTENANCE

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Signature and ISX CM870 Fuel System

STABITHERM INSTALLATION & SERVICE BOOKLET

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

BERMAD Fire Protection

Installation Instructions

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

TYPE E Main Valve Sizes 3 /8 through 12

SunMaxx Solar Filling Station Operating Instructions

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions

SHOT BLAST CABINET MODEL NO: CSB20B

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

SELECTION, APPLICATION AND MAINTENANCE

Model 5600 & 5600 Econominder

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Class 5 to 7 Truck and Bus Hydraulic Brake System

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

Auto-belay Cable Replacement Process

APM HDC-4000 O PTICAL FIBER P OLISHING M ACHINE

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

The cylinder head bolts tightening stages have been updated as listed in Table 1.

WIKA INSTRUMENT CORPORATION

Stainless Steel Valves For the Sanitary Industries

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Example. Fluid Power. Circuits

Watts Pure Water Systems

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

INSTALLATION AND SERVICE MANUAL

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Select Radiators Installation Guide

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Transcription:

Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set point, and produces an output air signal that is a function of this difference and the type of control. The output signal is transmitted to a control valve or other control device. The process measurement, set point, and output signal are indicated on the controller. A Siebe Group Company

MI 011-476 January 1980 Principle of Operation Standard Specifications Types of Control Suffix Code A1: A2: A3: A4: A5: A7: A8: Control Limits Proportional: Reset: Derivative: Differential Gap: Output Signal: Air Supply: Air Consumption: Air Connections: Ambient Temperature Limits: Weight: Case: On-Off Proportional Proportional plus Derivative Proportional plus Reset Proportional plus Reset plus Derivative Differential Gap Automatic Shutdown 4 to 400% 0.01 to 50 minutes per repeat 0.05 to 50 minutes 1 to 100% 3-15 psi or 20-100 kpa 20 psi (140 kpa) 0.3 std ft 3 /min (0.5 std m 3 /h) Tapped for 1/4 NPT 40 to +180 F ( 40 to +80 C) Approx. 10 lb (4.5 kg), excluding element Glass fiber reinforced plastic Principle of Operation 1. A differential linkage measures difference between measurement pointer and setting index positions. This error signal moves proportioning lever. 2. Proportioning lever pivots at its center on end of a flat spring. 3. This motion changes flapper nozzle relationship, causing relay to establish an output pressure. 4. Output pressure is fed back to proportioning bellows, which acts through proportioning lever to rebalance flapper nozzle. 5. Reset bellows and tank assembly are used when measurement must be maintained exactly at control point (without offset ). 6. Derivative tank assembly is used to improve system response to a slow process. 2

Principle of Operation MI 011-476 January 1980 Controller with Proportional, Reset, and Derivative Actions, and Automatic-Manual Transfer System (Optional) Proportional Control For description, see Items 1 through 4 above. 3

MI 011-476 January 1980 Principle of Operation On-Off Control On-off control is obtained by pivoting the proportional lever about a fixed point without proportioning or reset bellows. This controller can be equipped with an automatic shutdown unit. Differential Gap Control Differential gap control is obtained with positive feedback.. 4

Installation MI 011-476 January 1980 Installation Controller Mounting Mount controller level on a rigid support. If controller has Type 37 Meter, see page 8. Flush Mounting After case is inserted in panel, install mounting brackets as shown. Slide brackets firmly against panel and tighten bracket bolts to case. in mm Surface Mounting Loosely install mounting brackets flush with rear of case as shown. Attach brackets to panel with 1/4-inch bolts or #14 wood screws. Tighten mounting bracket bolts to case. in mm 5

MI 011-476 January 1980 Installation Pipe Mounting Remove mounting bracket from controller case. Securely fasten bracket on a 2-inch or 3-inch pipe. Then reinstall controller into bracket. Controller Dimensions and Connections Flush Mounting in mm Surface Mounting in mm 6

Installation MI 011-476 January 1980 Pipe Mounting in mm Pressure Connection 1/4 NPT female (up to 2000 psi or 14 MPa) 1/2 NPT male (above 2000 psi or 14 MPa) 9/16-18 Aminco (from 10000 psi or 70 MPa) Pneumatic Receiver Connection 1/4 compression fitting NOTE When installing piping, hold case connections stationary with wrench. Optional Integral Filter-Regulator Set in mm Air Supply and Output Piping For Control Valve Piping see Instruction MI 012-210. 7

MI 011-476 January 1980 Installation! WARNING Air is usually used as controller operating gas, and it is vented directly from case. If a hazardous 1 gas is to be used instead, GTC option must be specified. This option provides a vent connection on case which can be used to pipe gas to a location classified for its dispersal. In addition, in normal operation some gas may bleed from case; therefore, classification of controller location must permit presence of this gas. 1. Air supply must be regulated at 20 psi (140 kpa). 2. Controller uses about 0.3 std ft 3 /min (0.5 std m 3 /h) of air in normal operation. 3. Air must be clean and dry. Blow out filter regularly. 4. Air lines must be free of leaks. Mounting Controller with Type 37 Meter 1. See Nat l Elect l Code, NFPA 70, Art. 500-517. 8

Installation MI 011-476 January 1980 Automatic-Manual Transfer System (optional) The automatic-manual transfer system consists of a regulator, a sensitive balance indicator, and a transfer switch. The system permits switching between manual and automatic control without upsetting the process. The illustration below shows the components that are concerned with the transfer system. To Transfer from Manual to Automatic Control Slowly turn set point knob (or adjust remote set point, if present) to move balance indicator ball to within central portion of tube (not up against either end). Then turn switch to automatic (A). To Transfer from Automatic to Manual Control Turn regulator slowly to move balance indicator ball to within central portion of tube (not up against either end). Turn regulator so that top of knob moves in direction that ball is to move. Then turn switch to manual (M). Valve can now be controlled with regulator. 9

MI 011-476 January 1980 Installation Automatic-Manual Transfer Using 2-Position Nozzle Seal Switch (optional) In place of the transfer system above, a 2-position nozzle seal switch is available. Moving this switch to the manual (M) position, seals the nozzle line causing the output to increase to the supply pressure. The output can now be set to the desired value by reducing the pressure with an external supply regulator furnished by the user. To Transfer from Manual to Automatic Control Turn set point knob (or adjust remote set point, if present) so that set point index is in line with measurement pointer. Move switch to automatic (A). Quickly increase air supply pressure to 20 psi (140 kpa). To Transfer from Automatic to Manual Operation Slowly reduce air supply pressure to output pressure, and move switch to manual (M). Valve can now be controlled with regulator. 10

Installation MI 011-476 January 1980 Putting Into Operation For on-off, differential gap, or automatic shutdown controllers, see page 14. 1. Make sure that measuring system is properly installed and operating. 2. Set control dial so that index points to desired control action (output either increases or decreases with increasing measurement). With latch in lowered position (as shown below), control dial cannot be accidentally rotated to area of reverse control action. To reverse control action, push up latch and rotate dial so that latch is on other side of stop, then push down latch (see figure below). 11

MI 011-476 January 1980 Installation 3. Turn PROPORTIONAL BAND adjustment (on control dial) to 400 or to safe high value. Turn DERIVATIVE adjustment (if present) to 0.05. Turn RESET adjustment (if present) to 50 or safe high value. 4. Open shutoff valves and close bypass valve. 5. Turn set point knob (or adjust remote set point, if present) so that set point index is at desired value. 6. If controller is not equipped with optional automatic-manual transfer, proceed to Step 7. If controller is equipped with transfer, start up in manual as follows: a. Move transfer switch to manual (see page 9). b. Turn on 20 psi (140 kpa) air supply. Blow out filter. c. Adjust output with regulator so that measurement pointer is held as close as possible to set point index. d. After measurement has stabilized, move transfer switch to automatic (see transfer procedure on page 9). Process is now on automatic control. 7. If controller is not equipped with optional automatic-manual switch, turn on 20 psi (140 kpa) air supply. Blow out filter. 8. After measurement has stabilized, adjust proportional band, derivative, and reset controls (if present) for best process operation (see page 13). 9. With reset control, after process has stabilized with proper control settings, if set point index and measurement pointer do not coincide, adjust as follows: a. Loosen lockscrew. b. Adjust nylon eccentric to change index. Retighten lockscrew. 12

Installation MI 011-476 January 1980 Control Adjustments Effect of Various Proportional Band Settings Effect of Various Reset Times Proportional Controller (Model 43AP-A2) 1. Set PROPORTIONAL BAND at 400 or at safe high value. 2. Make change in set point. Observe process and output responses. 3. If cycling does not occur, adjust PROPORTIONAL BAND to half of previous value. 4. Repeat Steps 2 and 3 until cycling is observed. Then increase PROPORTIONAL BAND to twice its value. Proportional Plus Derivative Controller (Model 43AP-A3) 1. With DERIVATIVE at 0.05, adjust PROPORTIONAL BAND as described in Proportional Controller, above. 2. Adjust DERIVATIVE using same procedure as Proportional Band, except doubling each setting instead of halving it. Proportional Plus Reset Controller (Model 43AP-A4) 1. With RESET at 50 or at safe high value, adjust PROPORTIONAL BAND as described in Proportional Controller, above. 2. Adjust RESET using same procedure as Proportional Band. Proportional Plus Reset Plus Derivative Controller (Model 43AP-A5) 1. With RESET at 50 or at safe high value, and DERIVATIVE to 0.05, adjust PROPORTIONAL BAND as described in Proportional Controller, above. 13

MI 011-476 January 1980 Installation 2. Adjust DERIVATIVE using same procedure as Proportional Band, except doubling each setting instead of halving it. 3. Adjust RESET to final setting of Derivative in Step 2, above. On-Off and Automatic Shutdown Controllers As the measurement crosses the control point (determined by the setting index), the control valve fully opens (or closes), and as the measurement reverses and recrosses the control point, the control valve fully closes (or opens). 1. Rotate control dial so that arrow points to small rectangle of desired control action. 2. After process has stabilized, if setting index and measurement pointer do not coincide, adjust index as shown on top of Page 7 of Instruction MI 011-477. NOTE For operation details of automatic shutdown unit, see Instruction MI 011-484. Differential Gap Action Controller As the measurement goes below the lower control point, the control valve fully opens (or closes). This reverses the measurement but there is no change in control action until the measurement crosses the upper control point, at which time the valve fully closes (or opens). One control point is determined by the setting index and the other control point by the gap width (see example below). Gap width = difference between control points divided by span. For example, if measurement scale is graduated from 20 to 120, and control points are to be 70 and 90, gap width 90 70 = --------------------- = 20 % 120 20 Typical Differential Gap Action Control Record 14

Installation MI 011-476 January 1980 1. If Increasing measurement, INCREASING output section of control dial is used, turn set point knob (or adjust remote set point, if present) to bring index to LOWER control point. If Increasing measurement, DECREASING output is used, bring index to UPPER control point. 2. Rotate control dial so that arrow points to desired gap width with desired control action. 3. When measurement pointer (moving within gap) coincides with setting index, output (on output gauge) should change suddenly. If this change does not occur when the two are in line, adjust index as shown on bottom of Page 7 of Instruction MI 011-477. 15

MI 011-476 January 1980 Installation ISSUE DATES JAN 1980 Vertical lines to right of text or illustrations indicate areas changed at last issue date. The Foxboro Company 33 Commercial Street Foxboro, MA 02035-2099 United States of America http://www.foxboro.com Inside U.S.: 1-888-FOXBORO (1-888-369-2676) Outside U.S.: Contact your local Foxboro Representative. Facsimile: (508) 549-4492 Foxboro is a registered trademark of The Foxboro Company. Siebe is a registered trademark of Siebe, plc. Aminco is a trademark of American Instrument Co. Copyright 1980 by The Foxboro Company All rights reserved A Siebe Group Company MB 100 Printed in U.S.A 0180