Altivar 212 Drive. Selection Guide. Make the most of your energy SM



Similar documents
Bulletin 150 SMC Flex Smart Motor Controller Specifications

HVAC DRIVE H300 HVAC Drive for Building Automation

Easy to connect - Easy to configure Easy to install

Variable Speed Drives

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Frequency Converter Fv

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Altivar 71. Variable speed drives for synchronous motors and asynchronous motors

RM4TG20 three-phase network control relay RM4-T - range V

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Specifying a Variable Frequency Drive s

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Number 1 in efficiency

How To Use The Vacon 0 Machinery

Variable speed drives

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

vacon 100 hvac for indoor climate control

3753 en /b VE/B - VE/RG Va V riable speed drives

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Multi-Range Programmable DC Power Supplies 9115 Series

Phone: Fax: Web: info@clrwtr.com

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

DC Electronic Loads 8500 series

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications

SmartVFD HVAC and BYPASS

32VFD Variable Frequency Drives for Centrifugal Chillers

Three-phase monitoring relay CM-PFE

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Model: DC-A2IO Advanced HVAC Controller

vacon 100 hvac premium ac drive for indoor climate control

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Electronic Control Devices The European Product Catalogue 2007

EFC Frequency converters

Telephone- and leased line modem for industrial applications TD-36

Power Supplies 3. SDN-P DIN Rail Series

Products and solutions for lifting systems

NX Series Inverters. HVAC Pocket Programming Guide

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

NXL Series Inverters. HVAC Inverters made simple

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

Telemecanique Drives Solutions. from BPX. Edition 2. The brochure from BPX with everything you need to know about Telemecanique Variable Speed Drives

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Permissible ambient temperature Operation Storage, transport

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

vacon compact ac drives creating perfect harmony

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Quick Connect. quick - simple - efficient.

38 Series - Relay interface modules A

Thyristor-controlled power supplies and battery chargers

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Installation manual. Generator Paralleling Controller GPC multi-line C

Analog Servo Drive 25A8

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Multi-Range Programmable DC Power Supplies 9115 Series

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Altivar 61 Variable Speed Drive Controllers Simplified Manual

vacon x series rugged drives for the real world

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Meter Series 700

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

40.3. Control Relays and Timers

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Safety technique. Emergency stop module BO 5988 safemaster

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital input modules

NC-12 Modbus Application

Softstarters Type PSR

FX07 Field Controller

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PIEZOMETER AIRFLOW MEASURING RING

vacon 100 x & vacon 20 x decentralized ac drives

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

80 Series - Modular timers 16 A. Features

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Products and solutions for pumping, irrigation and piping

PSR The compact range Description

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Preset Counter signo 721

A1000 Cheat Sheet (Open Loop Vector)

Square D Model 6 Motor Control Centers

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Bimetallic Overload Relay Specifications

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Transcription:

Altivar 212 Drive Selection Guide Variable speed drives for asynchronous motors used in centrifugal pump and fan applications Make the most of your energy SM

Altivar 212 Drive Selection The Altivar 212 drive is intended for use with three-phase asynchronous motors for variable torque pump and fan applications. Select the Altivar 212 drive using the nameplate voltage and full load ampere rating of the motor nameplate and the table below. The Altivar 212 drive includes 3 logic inputs, 2 analog inputs, 1 analog output and 2 relay outputs (with 1 NO and 1 NO/NC contacts). It includes integrated 4 digit, 7 segment LED dispay with 7 button keypad, as well as RJ45 Modbus port, plus a 4 screw removable terminal block for software selectable BACnet, Modbus, METASYS N2 or APOGEE P1 communication protocols. LonWorks is available in an option card. Altivar 212 Drive Selection Enclosure rating AC Input line voltage 208/240 Vac threephase 380/480 Vac threephase Three-phase motor power Continuous Output current IP 20 Open style product HP kw A Catalog number QTY Frame size Type 1 conduit kit (purchase ATV212 and conduit Kit for Type 1 installation) Type 12/IP54 Catalog number QTY Catalog number C QTY Frame size 1 0.75 4.6 ATV212H075M3X 1 VW3A31814 2 1.5 7.5 ATV212HU15M3X 1 VW3A31814 3 2.2 10.6 ATV212HU22M3X 1 VW3A31814 4 3 13.7 ATV212HU30M3X 2 VW3A31815 5 4 18.7 ATV212HU40M3X 2 VW3A31815 7.5 5.5 24.2 ATV212HU55M3X 3 VW3A31816 10 7.5 32 ATV212HU75M3X 3 VW3A31816 15 11 46.2 ATV212HD11M3X 4 VW3A31817 20 15 61 ATV212HD15M3X 4 VW3A31817 25 18.5 74.8 ATV212HD18M3X 4 VW3A31817 30 22 88 ATV212HD22M3X 5 VW3A9206 40 30 117 ATV212HD30M3X 7 VW3A9208 1 0.75 2.2 ATV212H075N4 1 VW3A31814 ATV212W075N4 1 2 1.5 3.7 ATV212HU15N4 1 VW3A31814 ATV212WU15N4 1 3 2.2 5.1 ATV212HU22N4 1 VW3A31814 ATV212WU22N4 1 4 3 7.2 ATV212HU30N4 2 VW3A31815 ATV212WU30N4 2 5 4 9.1 ATV212HU40N4 2 VW3A31815 ATV212WU40N4 2 7.5 5.5 12 ATV212HU55N4 2 VW3A31815 ATV212WU55N4 2 10 7.5 16 ATV212HU75N4 3 VW3A31816 ATV212WU75N4 2 15 11 22.5 ATV212HD11N4 3 VW3A31816 ATV212WD11N4 3 20 15 30.5 ATV212HD15N4 4 VW3A31817 ATV212WD15N4 3 25 18.5 37 ATV212HD18N4 4 VW3A31817 ATV212WD18N4 4 30 22 43.5 ATV212HD22N4S C 4 VW3A31817 30 22 43.5 ATV212HD22N4 5 VW3A9206 ATV212WD22N4 5 40 30 58.5 ATV212HD30N4 5 VW3A9206 ATV212WD30N4 5 50 37 79 ATV212HD37N4 6 VW3A9207 ATV212WD37N4 6 60 45 94 ATV212HD45N4 6 VW3A9207 ATV212WD45N4 6 75 55 116 ATV212HD55N4 7 VW3A9208 ATV212WD55N4 7 100 75 160 ATV212HD75N4 7 VW3A9208 ATV212WD75N4 7 ATV212HU15N4 ATV212W075N4 ATV212HU55M3X ATV212HD37N4 ATV212HU30M3X ATV212HD37N4 These horsepower, kw and continuous ampere ratings apply to default switching frequency and maximum 40 C ambient. Refer to the installation manual for derating curves as a function of switching frequency, ambient temperature and mounting conditions. IP20 Altivar 212 drives can be installed as UL Type 1 with the optional conduit box when following instruction in the Installation Manual. To select an Altivar 212W... drives with Class B EMC filter, add the letter C to the end of the standard catalog number. C Late 3Q 2011 availability. 2

Altivar 212 Accessories and Options User interface options For use with Catalog number QTY Remote LCD display keypad Altivar 212, 312, 32, VW3A1101 61, 71 8 line, 24 characters per line, plain text, 8 keys, rotary wheel, 60 C IP54 rated Remote LCD keypad mounting accessories IP54 rated kit for remote mounting LCD keypad on enclosure door VW3A1101 VW3A1102 Clear plastic door for use with VW3A1102 for IP65 rating and tamper resistance VW3A1102 VW3A1103 Female/Female right angle RJ45 adaptor, to connect cable and keypad.* VW3A1101 VW3A1105 (*not required if using VW3A1102) Remote LCD keypad mounting cables equipped with two RJ45 connectors 1 meter length VW3A1101 VW3A1104R10 3 meter length VW3A1101 VW3A1104R30 5 meter length VW3A1101 VW3A1104R50 10 meter length VW3A1101 VW3A1104R100 Multi-loader Altivar 12, 212, 312, 32 VW3A8121 Altistart 22 Use to copy configurations between like drives, PC Soft or SoMove PC software Software For use with Catalog number PCSoft Altivar 21 and 212 Download at www. schneider-electric.us/go/ drives PC software use for: configuring, monitoring and trouble shooting Alitvar 212 drives Requires one of two cables (noted below) to connect a PC to the RJ45 Modbus port on the drive USB/RS485 cable: equipped with USB connector and RJ45 connector Altivar and Altistart TCSMCNAM3M002P RS 232-RS485 converter with SUB-D and RJ45 port, cable with two Altivar 212 VW3A8106 RJ45 connectors SoMove Mobile Altivar 212 Download at www. schneider-electric.us/go/ drives Software for compatible mobile phones provides wireless interface similar to the LCD display Requires Modbus to Bluetooth adaptor to connect phone and Altivar 212 drive Modbus Bluetooth adaptor: connects to RJ45 Modbus port on the drive Altivar 12, 212, 312,61, 71 VW3A8114 Communication option For use with Catalog number LonWorks communication option card Altivar 212 VW3A21212 Provides 4 screw terminal block for connection to LonWorks network Install in place of standard control board that comes mounted in the Altivar 212 drive The I/O count is reduce to 3LI, 1 AI and 1 NO/NC relay Mounting kit For use with Catalog number DIN rail mounting kit Altivar 212H075M3X VW3A31852 22M3X and Altivar 212H075N4 22N4 For installation on to 35mm wide DIN rail VW3A1101 VW31101, VW31102, VW31103, VW3A1104R10 VW3A8121 PCSoft Software SoMove Mobile Software VW3A21212 3

Altivar 212 Drive Technical Characteristics Environmental Specifications Temperature ratings 0 to + 40 C operational without de-rating, up to 60 C with de-rating (see installation manual for deratings) Altitude ratings Up to 3,300 ft (1,000 meters) without de-rating, de-rate nominal current by 1% for each additional 330 ft ( 100m) up to 10,000 ft ( 3,000 m) Limit to 6,600 ft (2,000 m) if supplied by corner grounded distribution system Humidity Up to 95% non-condensing, IEC 60068-2-3 Vibration resistance 1.5 mm peak to peak from 3 to 13 Hz conforming to EN/IEC 600068-2-6, 1 gn from 13 to 200 Hz conforming to IEC/EN 60068-2-8 Shock resistance 15 gn for 11 ms conforming to IEC/EN 60068-2-27 Pollution degree 1 HP to 25 HP @ 200/240 V, 1 HP to 5 HP @ 380/480 V: Pollution degree 2 per IEC/EN 61800-5-1, 30 HP to 40 HP @ 200/240 V, 30 HP to 100 HP @ 380/480 V: Pollution degree 3 per IEC/EN 61800-5-1 Degree of protection: ATV212 H range ATV212 W range Electrical Specifications Input voltage and HP range ATV212 W is available in 380/480 range only IP20, Conformal coating per IEC 60721-3-3 classes 3C2 and 3S2, Type 1 with optional conduit kit IP54/Type 12, Conformal coating per IEC 60721-3-3 classes 3C2 and 3S2 200 15% to 240 +10%, Three phase input, Three phase output, 1 HP to 40 HP 380 15% to 480 +10%, Three phase input, Three phase output, 1 HP to 100 HP Input frequency 50 Hz -5% to 60 Hz +5% Galvanic isolation Galvanic isolation between power and control (inputs, outputs and power supplies) Drive input power section Six pulse bridge rectifier Drive output power section IGBT inverter with pulse width modulated output Power factor Above 99% Efficiency Above 98% at full load Switching frequency Selectable from 6 to 16 khz, 12 khz nominal rating for 1 HP to 20 HP @ 200/240 V, 380/480 V Selectable: 6 to 16 khz, 8kHz nominal rating for 30 HP to 40 HP @ 200/240 V, 30 HP to 100 HP @ 380/480 V Acceleration and deceleration ramps 0.1 to 3200 seconds in 0.1 seconds increments Frequency output range 0.5 to 200 hertz Skip frequencies Three adjustable skip frequency bands Speed range 1 to 10 Integrated motor protection Class 10 electronic overload protection Asynchronous motor control profiles Sensorless flux vector, 2 point volts/hertz, quadratic volts/hertz, energy savings mode: a optimization motor algorithm that automatically optimizes voltage based on load Transient over current 110% nominal for 60 seconds, 180% for 2 seconds Embedded functions Over 50 functions dedicated to pump and fan applications User interface On board: 5 LED indicators for various functions, 4 digit, 7 segment LED display with 7 button keypad for: Run, Stop/Reset, Local/remote, Speed up, speed down, Mode selection and Enter. Quick start menu, fault history, I/O mapping, last-used menus, status monitoring and self diagnostics. Fault messages and status such as: power on time, elapsed time, motor run time, line voltage, motor current, ready to run, running, motor speed, etc. Embedded communication Embedded RJ45 port for remote keypad connection, Multi-loader, PC software, or Bluetooth dongle for So Mobile smart phone connection. Embedded 4 screw removable terminal for daisy chain connection for: Modbus, BACnet, Metesys N2, or Apogee P1 communication networks. Harmonic abatement Embedded reduced harmonic technology provides <35% THDI at VFD input terminals, which is equivalent to a 3% line reactor or DC choke. See technical paper 8800DB0702 for more information. EMC compliance: ATV212 H and W N4 range: ATV212 W N4C range: ATV212H M3X range: Compliance Certifications Integrated Class 2 EMC filter for radiated and conducted emissions, IEC 61800-3, category C2 and C3 Integrated Class 2 EMC filter for radiated and conducted emissions, IEC 61800-3, category C1 No integrated EMC filter (use optional filters to reduce emission levels) UL 508C, RoHS, IEC 61800-5-1, IEC/EN61000-3-12 THDI harmonic standard UL File E116875, CSA 2278406, UL 508C, Plenum rated per UL508C for UL1995 installations, C-Tick, NOM 117, CE marked 4

Altivar 212 Inputs/Outputs Electrical Characteristics Default function setting Function Terminals Characteristics External power supply input PLC +24 Vdc input for external power supply for logic inputs Max. permissible voltage: 50 Vdc Internal supply P24 Short-circuit and overload protection: 24 Vdc supply (min. 21 Vdc, max. 27 Vdc), maximum current: 200 ma Common CC 0 Vdc common (2 terminals) Fault relay FLA 1 relay logic output, 1 N/C contact, and 1 N/O contact with common point FLB Minimum switching capacity: 10 ma for 5 Vdc FLC Maximum switching capacity: On resistive load (cos = 1): 5 A for 250 Vac or 30 Vdc On inductive load (cos = 0.4 and L/R = 7 ms): 2 A for 250 Vac or 30 Vdc Max. response time: 10 ms Speed attained F: Run forward R: Preset speed at 15 Hz RES: Reset Output frequency Configurable relay outputs Configurable logic inputs RY RC F R RES 1 relay logic output, 1 N/O contact Minimum switching capacity: 3 ma for 24 Vdc Maximum switching capacity: On resistive load (cos = 1): 3 A for 250 Vac or 30 Vdc On inductive load (cos = 0.4 and L/R = 7 ms): 2 A for 250 Vac or 30 Vdc Max. response time: 7 ms ± 0.5 ms 3 programmable logic inputs, 24 Vdc, compatible with level 1 PLC, IEC 65A-68 standard Impedance: 4.7 kω Maximum voltage: 30 Vdc Max. sampling time: 2 ms ±0.5 ms Multiple assignment makes it possible to configure several functions on one input Positive logic (Source): State 0 if 5 Vdc or logic input not wired, state 1 if 11 Vdc Negative logic (Sink): State 0 if 16 Vdc or logic input not wired, state 1 if 10 Vdc Configurable analog output FM 1 switch-configurable (SW101) voltage or current analog output: Voltage analog output 0 10 Vdc, minimum load impedance 7.62 kω Current analog output X Y ma by programming X and Y from 0 to 20 ma, maximum load impedance: 970 Ω Max. sampling time: 2 ms ±0.5 ms Resolution: 10 bits Accuracy: ±1 % for a temperature variation of 60 C Linearity: ±0.2% Internal supply available PP Short-circuit and overload protection: One 10.5 Vdc ± 5% supply for the reference potentiometer (1 to 10 kω), maximum current: 10 ma Primary speed reference, 0 10 V Secondary speed reference, 1 10 V Configurable analog/ logic input VIA Switch-configurable voltage or current analog input: Voltage analog input 0 10 Vdc, impedance 30 kω maximum voltage: 24 Vdc Analog current input X Y ma by programming X and Y from 0 to 20 ma, with impedance 250 Ω Max. sampling time: 3.5 ms ±0.5 ms Resolution: 10 bits Accuracy: ±0.6% for a temperature variation of 60 C Linearity: ±0.15% of the maximum value This analog input is also configurable as a logic input Consult the Altivar 212 Programming Manual for more information Configurable analog input VIB Voltage analog input, configurable as an analog input or as a PTC probe input Voltage analog input: 0 10 Vdc, impedance 30 kω max. voltage 24 Vdc Max. sampling time: 22 ms ±0.5 ms Resolution: 10 bits Accuracy: ±0.6% for a temperature variation of 60 C Linearity: ±0.15% of the maximum value PTC probe input: 6 probes max. mounted in series Nominal value < 1.5 kω Trip resistance 3 kω, reset value 1.8 kω Short-circuit detection threshold < 50 Ω Graphic display terminal or Modbus RJ45 Fieldbus Open style connector Used to connect graphic display terminal or connect the drive to a Modbus fieldbus Note: for using Modbus on the RJ45, modify parameter F807 (see Modbus manual) Refer to communication manual related to the fieldbus 5

Altivar 212 Drive Integrated Fan and Pump Functionality Run command Speed command Run status Speed feedback Fault Output Loss of Speed Automatic Restart Skip Frequency Bands Local/Remote Control Catch on the Fly Damper Control Relay Smoke Purge Override Broken Belt Detection PID Control Sleep/Wake-up Pump Jam Management Motor direction protection Input to drive by remote contact from the BAS, 24 vdc supplied by VFD Input to drive from the BAS; typically 4-20mAdc or 0-10 Vdc Output contact from drive to the BAS; 1 N.O. contact on drive Analog output from drive to the BAS; typically 4-20mAdc, or assignable to meter values Output contact from drive to the BAS; 1 N.O. & 1 N.C. contact on drive Configuration to run at last speed or a pre-defined speed on loss of speed command Selectable configuration to automatically restart after cause of fault is cleared Three skip frequency settings with adjustable bandwidth to tune out resonating frequencies in piping or ductwork Keypad selectable: local keypad control for Run, Stop and speed control or from remote signal from BAS Configuration to initiate speed and direction search to provide smooth start of windmilling fans Output on the drive to control damper opening sequence, and wait for feedback to start the motor Logic Input on the drive configured to run the motor at configured speed for forced ventilation Configuration to detect under load condition and initiate alarm sequence Set point and feedback inputs for proportional, integral, and derivative control Configuration in the drive to stop the pump at low or no flow and re-start on demand for flow Configuration to manage blocked pump impeller Configuration to prevent operation in reverse direction Scan this code to download the Altivar 212 Installation Manual Typical air handling applications: HVAC supply and return fans Exhaust and ventilation fans Cooling tower fans Energy recovery wheels Typical pumping applications: Cooling tower pumps Chilled water and hot water pumps Fountain pumps Domestic water supply pumps Scan this code to download the Altivar 212 Programming Manual 6

Altivar 212 Drive Dimension and Weights Electronic 2D sales drawings with specifications and 3D CAD models available at www.schneider-electric.us/go/cad IP20 drives UL Type 1 Frame size a Width b Height c Depth Approximate weight d Height with Type 1 conduit kit Weight with Type 1 conduit kit mm in. mm in. mm in. kg. lbs. mm in. kg. lbs. 1 105 4.13 143 5.63 150 5.91 1.2 2.65 194.5 7.66 2.1 4.65 2 140 5.51 184 7.24 150 5.91 2.4 5.29 236 9.29 3.53 7.79 3 180 7.09 232 9.13 170 6.69 4.7 10.36 311 12.24 6.05 13.36 4 245 9.65 329.5 12.97 190 7.48 7 15.44 401 15.79 7.23 15.94 5 240 9.45 420 16.54 213 8.39 9 19.85 480 18.89 10.59 23.35 6 240 9.45 550 21.65 244 9.61 38.1 84.01 610 24.01 39.92 88.01 7 320 12.60 630 24.80 289.9 11.41 55.4 122.16 833 32.80 57.68 127.16 Frame 1 and 2 Frame 3 and 4 Frame 5 and 6 Frame 7 7

Altivar 212W Drive Dimension and Weights IP54 drives Frame size a Width b Height c Depth Appr. weight mm In. mm In. mm In. kg. lbs. 1 215 8.46 297 11.69 192 7.56 7 15.44 2 230 9.06 340 13.39 208 8.19 9.65 21.28 3 290 11.42 560 22.05 315 12.40 30.3 66.81 4 310 12.20 665 26.18 315 12.40 37.4 82.47 5 284 11.18 720 28.35 315 12.40 49.5 109.15 6 284 11.18 880 34.65 343 13.59 57.4 126.57 7 362 14.25 1000 39.51 364 14.33 61.9 136.49 Frame 1 and 2 Frame 3 to 7 Scan this code to review 3D CAD drawings for Altivar 212 Schneider Electric USA, Inc. Automation and Control Center of Excellence 8001 Knightdale Blvd. Knightdale, NC 27545 Tel: 919-266-3671 www.schneider-electric.us Schneider Electric Canada, Inc. 19 Waterman Avenue Toronto, ON M4B 1Y2 Tel: 1-800-565-6699 www.schneider-electric.ca This document has been printed on recycled paper 2011 Schneider Electric. All Rights Reserved. Document Number 8800HO1101 May 2011 sf