Yamaha Engine NMEA2000 Connection



Similar documents
NMEA 2000 Engine Interface

EP-85R Storage Device

LMS-480M, LMS-480DF & GlobalMap 4800M

EP-80R Temp. Electronic Temperature Sensor Installation and Configuration Instructions

Suzuki Modular Instrument System (SMIS) 4 Display

Prep Plus Bulletin. Bulletin No. 004 August 15, 2007

Outboard Engine Supplement

OIL PRESS 71.8 PSI FUEL. Cloud based, diagnostic, engine monitoring and reporting system.

HOOK-X Series. Operation manual. lowrance.com ENGLISH. HOOK-4x HOOK-5x HOOK-7x

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

HOOK-3x DSI. Operation manual. lowrance.com ENGLISH. HOOK-3x DSI

NAVICO SOFTWARE UPGRADE TOOL

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Model SETR-50 and SETR-51 Trim Tab Control

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

StructureScan HD Module. Installation Guide ENGLISH

Volvo Penta IPS Autopilot System DPU Installation and System Connections. Document Number: Date: May 2005

FLOWMETER INSTALLATION INSTRUCTIONS

User s Manual. Revision 1.1. Copyright 2012 Maretron, LLP All Rights Reserved

Pinpoint Gateway Setup Instructions

K-Type Thermocouple Sensor User s Guide

HDS Gen2 RTM 4.0 software update

HD udta Quick-Start Guide

CAN BUS UTILITY VW ACTIVE MSY

MTX-D, Oil Temperature/Pressure Gauge

StructureScan HD Transducer Installation manual

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

Fuel Alert FA-KRS-P21. Mounting instruction

The RIDZ 8x2 Audio Switcher

Mark and Elite series DSI. Sonar Operation manual

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

Before installation it is important to know what parts you have and what the capabilities of these parts are.

DTA INSTALLATION PROCESS & USER GUIDE FOR CHARTER BUSINESS CUSTOMERS

5X, Mark 5X, Mark 5X Pro & Elite 4X

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

NAVICO Software Upgrade Tool. English sw Document no: Doc Revision: D Date: January 2010

Complete Train Control. Run Your Trains, Not Your Track!

StructureScan 3D. User Guide ENGLISH.

TotalScan Transducer Installation manual

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

Grandstream Networks, Inc.

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Export: Exporting the call log or Voice Mail messages from the Viewer software is not supported.

Traditional Sonar and DSI Sonar Installation

Connecting instruments serially to your computer

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

I Click on a link tab to jump to that page. Cover Page

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Elite Monitoring System Installation and Operation

Malibu Monte Carlo El Camino

Connecting to the Internet

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Integrated KVM 2-Port Switch

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Linksys E2000 Wireless-N Router Configuration Guide

USER GUIDE. Publication AP7080. Allen & Heath 1 XONE:1D User Guide

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Berkeley Audio Design Alpha USB

The fastest and easiest way to troubleshoot Marine Electronic Fuel Injection Systems USER S GUIDE Version 5

DUKANE Intelligent Assembly Solutions

Transporter Current Flow Diagram No. 80 / 1

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

Addendum for compatible Navico MFD s that support the following Broadband 4G Radar features:

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

Quick Start Guide Ski Doo Snowmobiles

USB Security Key Instructions

GROM Interface Installation into Nissan and Infiniti cars using NIS02 vehicle specific harness

Yamaha R1 2007/2008/2009 R6 2006/2007/2008 Plug&Play kit user manual

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

I Click on a link tab to jump to that page. Cover Page

Quick Reference Guide VT55 & OBDII. Customer Service TPMS Version: QSG /12

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

AUTOPILOT BUYERS GUIDE

Lenco Preisliste Stand: Mai 2015

SYSTEM 45. C R H Electronics Design

ikommunicate NMEA - SignalK Gateway

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

RMK-9. Installation and Operation instructions. ENGLISH Date: Document number: EN 2013 Raymarine UK Limited

CMG-RTM Real-time Clock/ GPS Emulator

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Digi-Motor Installation Guide

ViewLine At the cutting edge of tomorrow s trends. < 7 m

Table of Contents. TransformerIQ FAQs 1

MTX-D, Boost/Shift Gauge

RETAINS STEERING WHEEL CONTROLS, SYNC MEDIA PLAYER, SYNC BLUETOOTH AND MORE!

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Chevy Bel-Era

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

HD Wing Camera II Short manual for use in R/C planes English version Dan Dolata Ad Astra on RCGroups.com

ELECTRICAL. Table of Contents. Section 2D Wiring Diagrams. Troll Control... 2D-39

User Manual 2-Port USB KVM Switch with Audio GCS632U PART NO. M0104

NC-12 Modbus Application

RIO1S. Relay / Input / Output Transformer-Balanced Module. Features

4. Do you have a VGA splitter ( Y Cable)? a document camera?

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

Transcription:

Yamaha Engine NMEA2000 Connection Many Yamaha outboard engines have the ability to output engine data to a NMEA 2000 network. This output from the engine can be displayed on a NMEA 2000 compatible Navico Multi Function Display such as the Lowrance HDS, Lowrance LMF 200 and 400 gauges, the Simrad NSS/NSE/NSO or the B&G Zeus. The vessel must be equipped with and existing or new NMEA 2000 network as pictured below. + _ 10-17 V DC Yamaha 4 stroke 50 250 2 stroke HDPI 150 350 Command Link Plus Systems RPM Alternator Voltage Engine Hours Engine Temperature* Fuel Pressure Fuel Rate Oil Pressure Trim * Water Pressure Warnings Boat Speed Water Depth Surface Water Temperature * 2006 and newer models. Digital trim must be connected by a Yamaha dealer. F50, T50, F60, T60, F75,F90, F115, LF115, F150, LF150, F200, LF200, F225, F225, F250, LF250. Z150, LZ150, VZ150, Z175, Z200, LZ200, VZ225, Z250, LZ250, VZ250, Z300, LZ300, VZ300.

Engine Connections: No Command Link Connect to the 4 pin factory harness located under the engine cowling using the Navico (000 0120 37) engine interface cable. See your Yamaha dealer for exact engine connector location. 1) 000 0120 37 Adapter. 2) Adapter installed in cowling. 3) Yamaha 4 pin connector. 4) Completed connection. Connecting to an Engine without Command Link If the Yamaha engine which is being connected to the NMEA 2000 network is not already connected to the Yamaha Command Link system, then the Yamaha Engine Interface cable connects directly to the NMEA 2000 connector under the engine s cowling. The NMEA 2000 connector is located on the starboard side of the engine near the bottom of the cowling. It is a white, 4 pin connector, with only two wires connected, blue and white. This connector might have a water proof plug installed from the factory, if so the plug must be removed before the Yamaha Engine Interface can be installed. Once this connection is made connect the Micro C connector to the vessels NMEA2000 network as shown in the system diagram on page 1 of this document. Engine Connections: Command Link Connect to the Command Link bus using the Yamaha Command Link Gateway (MAR GTWAY ML 09). 1) MAR GTWAY ML 09 2)Yamaha Command Link junction box (back). 3) Yamaha Command Link junction box (front). 4) Command Link terminator removed. Connecting to an Engine with Command Link Yamaha s Command Link is an engine and gauge network system based on NMEA 2000. This system connects to the engine through the same NMEA 2000 connector under the cowling as shown above. The Command Link system does not use discrete T connectors, but large junction boxes in order to connected devices. To connect Navico NMEA 2000 devices to a Yamaha Command Link System, the Yamaha Engine Gateway Cable, (MAR GTWAY ML 09) pictured above, will be used to extend the backbone of the network by changing it from the Yamaha connector system to the standard NMEA 2000 connector system. The Command Link terminator must be removed from the junction box that will be used to connect the Yamaha Engine Interface Gateway and an NMEA 2000 terminator (female) will be used to terminate the end of the NMEA 2000 network, as shown below.

Engine Connections: Command Link Plus Connect to the Command Link Plus network using the 6 pin Command Link Plus Gateway cable MAR GTWAY KT 00. Command Link Plus Gateway MAR GTWAY KT 00 Yamaha Command Link Plus Yamaha introduced the Command Link Plus system in 2009 with their new 4.2L F225/250/300 Offshore series of motors and the redesigned 5.3L F350 motor. Although the original Command Link System in natively compatible with NMEA 2000, the Command Link Plus System is not. To connect the Command Link Plus system to a NMEA 2000 network, the Yamaha Command Link Plus Gateway must be used. The Yamaha Command Link Plus Gateway is not the same as the Yamaha Command Link Gateway. The Command Link Plus Gateway is also only available from Yamaha, Yamaha part number MAR GTWAY KT 00. The Command Link Plus Gateway has a 6 pin Yamaha connector and the standard NMEA 2000 style connector. If both the Command Link Plus and Command Link buses are utilized it is important to note that the two buses should never be connected to each other. This could result in damage to the Yamaha system.

Connection locations for Command Link Plus. Digital Trim Connection If the Yamaha engine was previously connected to an analog trim gauge, the trim information output by the engine onto the NMEA 2000 network will be inaccurate. To enable accurate Trim Data onto the NMEA 2000 network, an additional connection must be made under the cowling. There are two single wire connectors under the cowling, near the NMEA 2000 connector, that must be connected together to allow accurate NMEA 2000 trim information to be transmitted from the engine. Both connectors have a pink wire. See your Yamaha dealer for exact location. MFD Setup After the physical connections have been made the user can now setup the unit to display the engine data. On HDS perform the following steps: 1) Vessel Setup: Press the Menu key twice to access the system menu, select the Fuel menu then Vessel Setup and press Enter. a. Change the Vessel Setup to match the Engine/Tank configuration of the vessel.

i. b. Set the Tank Size. i. c. Select Save to retain these settings. 2) With the Engine powered on Confirm that it shows up in the NMEA 2000 device list. a. Press the Menu key twice to access the system menu, select the Network menu then Device List and press Enter. i. You should now see your engine listed along with any other NMEA 2000 devices that are connected to your network. 1. b. From the Device List you can highlight the Engine and press enter to see and the Data that is available from the Engine. i. Scroll to the Data tab and press Enter. 3) Confirm that the data sources are set for the Engine. a. Press the Menu key twice to access the system menu, select the Network menu then Data Sources and press Enter. i. From here select Engine and press Enter. ii. Auto Configure the Network. In most cases this will set the data sources to the correct location. *If the engine instances are not set by Yamaha you will need to use Yamaha Command Link gauges to set them or have a Yamaha dealer set them.

1. You may also manually select the engine you wish to set (Port/Center/Starboard) and press Enter. 2. From here you can manually set the data source for all engine related information. a. 4) Now Data overlays and the Info gauge screen can be set up. a. Reference the manual for your MFD to set overlays and edit the gauge screen.