80 Series - Modular timers 16 A. Features 80.01 80.11



Similar documents
80 Series - Modular timers 16 A. Features

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

38 Series - Relay interface modules A

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

13 SERIES. Electronic step relays A

49 Series - Relay interface modules A. Features

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

40 Series - Miniature PCB/Plug-in relays A. Features

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

60 Series - General purpose relays 6-10 A. Features

15 Series - Electronic step relay and dimmer. Features SERIE

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

12 Series - Time switches 16 A. Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Analog signal converters CC-E I/I Current / current isolators

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Safety technique. Emergency stop module BO 5988 safemaster

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Relés e Contatores de Estado Sólido SIRIUS

Thermistor motor protection

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM4TG20 three-phase network control relay RM4-T - range V

3-phase, bidirectional energy meter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RY2 miniature industrial relays

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Voltage Regulator SPAU 341 C. Product Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic overload relay EF19 and EF45

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Telephone- and leased line modem for industrial applications TD-36

Redundancy Module QUINT-DIODE/40

Pluggable interface relays CR-P Pcb relays

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. S.p.A. ISO 9001 ISO The power in relays and timers since 1954

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

STRATO LED Drivers 70W, Single output

Electric Rotary Actuator - On/Off or programmable control actuator

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Relays and Timers Specifications Bulletin Number 700

Quick Connect. quick - simple - efficient.

Electronic overload relay EF65, EF96 and EF146

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

HERZ-Thermal Actuators

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Speed Control Relays SX2

PHOENIX CONTACT - 01/2007

7.5 Watt AC-DC Switch Power Supply

Easy Multifunctional Safe

Digital input modules

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Power Meter Series 700

Solid-state Timers H3DK

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

E-STOP relays, safety gate monitors

Rosemount 333 HART Tri-Loop

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Multifunction Digital Timer

Energy Management Energy Meter Type EM23 DIN

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

ABB i-bus KNX SA/S Switch Actuators Product Manual

Rack mounted telephone- and leased line modem for industrial applications

Transcription:

80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h High input/output isolation 35 mm rail (EN 60715) mount Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip New multi-voltage versions with PWM clever technology / 80.11 Multi-function AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on AI: On-delay FOR UL RATINGS SEE: General technical information page V For outline drawing see page 6 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V AC (50/60 Hz) Rated power AC/DC (50 Hz)/W Operating range V AC Specified time range Repeatability % Recovery time Minimum control impulse Setting accuracy-full range % Electrical life at rated load in AC1 cycles Ambient temperature range C Protection category Approvals (according to type) (with control signal) 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 250/400 250/400 4,000 4,000 750 750 0.55 0.55 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) AgCdO AgCdO 12 240 24...240 12 240 24...240 < 1.8 / < 1 < 1.8 / < 1 10.8...265 16.8...265 10.8...265 16.8...265 (0.1 2)s, (1 20)s, (0.1 2)min, (1 20)min, (0.1 2)h, (1 24)h ± 1 ± 1 100 100 50 ± 5 ± 5 100 10 3 100 10 3 10 +50 10 +50 IP 20 IP 20 1

80 Series - Modular timers 16 A Features 80.21 80.41 80.91 Mono-function timer range 80.21 - Interval, multi-voltage 80.41 - Off-delay with control signal, multi-voltage 80.91 - Asymmetrical flasher, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h High input/output isolation 35 mm rail (EN 60715) mount Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip New multi-voltage versions with PWM clever technology 80.21 / 80.41 / 80.91 DI: Interval BE: Off-delay with control signal LI: Asymmetrical flasher (starting pulse on) LE: Asymmetrical flasher (starting pulse on) with control signal FOR UL RATINGS SEE: General technical information page V For outline drawing see page 6 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V AC (50/60 Hz) Rated power AC/DC (50 Hz)/W Operating range V AC Specified time range Repeatability % Recovery time Minimum control impulse Setting accuracy-full range % Electrical life at rated load in AC1 cycles Ambient temperature range C Protection category Approvals (according to type) 2 (with control signal) (without control signal) 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 16/30 250/400 250/400 250/400 4,000 4,000 4,000 750 750 750 0.55 0.55 0.55 16/0.3/0.12 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) 500 (10/5) AgCdO AgCdO AgCdO 24...240 24...240 12...240 24...240 24...240 12...240 < 1.8 / < 1 < 1.8 / < 1 < 1.8 / < 1 16.8...265 16.8...265 10.8...265 16.8...265 16.8...265 10.8...265 (0.1 2)s, (1 20)s, (0.1 2)min, (1 20)min, (0.1 2)h, (1 24)h ± 1 ± 1 ± 1 100 100 100 50 50 ± 5 ± 5 ± 5 100 10 3 100 10 3 100 10 3 10 +50 10 +50 10 +50 IP 20 IP 20 IP 20 (with control signal)

80 Series - Modular Solid State timer (SST) 1 A Features Multi-function and multi-voltage solid-state output timer 17.5 mm wide Six time scales from 0.1s to 24h High input/output isolation 35 mm rail (EN 60715) mount output (24...240 V AC/DC), independent from the input voltage Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip input with PWM clever technology Multi-function AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on For outline drawing see page 6 (with control signal) Output circuit Contact configuration 1 NO (SPST-NO) Rated current A 1 Rated voltage V AC/DC 24...240 Switching voltage range V AC/DC 19...265 Rated load AC15 A 1 Rated load DC1 A 1 Minimum switching current ma 0.5 Max. OFF-state leakage current ma 0.05 Max. ON-state voltage drop V 2.8 Input circuit Nominal voltage (U N ) V AC (50/60 Hz) 24...240 24 240 Rated power (50 Hz)/W 1.3/1.3 Operating range V AC 19...265 19...265 Specified time range (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Repeatability % ± 1 Recovery time 100 Minimum control impulse 50 Setting accuracy-full range % Electrical life cycles Ambient temperature range C Protection category Approvals (according to type) ± 5 100 10 6 20 +50 IP 20 3

80 Series - Modular timers 6-8 A Features 80.61 80.82 Mono-function timer range 80.61 - Power off-delay (True off-delay), multi-voltage 80.82 - Star-delta, multi-voltage 17.5 mm wide Rotary range selector, and timing trimmer Four time scales from 0.05s to 3 min (type 80.61) Six time scales from 0.1s to 20min (type 80.82) High input/output isolation 35 mm rail (EN 60715) mount 80.61 / 80.82 BI: Power off-delay (True off-delay) Transfer time can be regulated (0.05 1)s SD: Star-delta FOR UL RATINGS SEE: General technical information page V For outline drawing see page 6 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V AC (50/60 Hz) Rated power AC/DC (50 Hz)/W Operating range V AC Specified time range Repeatability % Recovery time Minimum control impulse Setting accuracy-full range % Electrical life at rated load in AC1 cycles Ambient temperature range C Protection category Approvals (according to type) 4 1 CO (SPDT) 2 NO (DPST-NO) 8/15 6/10 250/400 250/400 2,000 1,500 400 300 0.3 8/0.3/0.12 6/0.2/0.12 300 (5/5) 500 (12/10) AgNi AgNi 24...240 24...240 24 220 24...240 < 0.6/ < 0.6 < 1.3/ < 0.8 16.8...265 16.8...265 16.8...242 16.8...265 (0.05 2)s, (1 16)s, (8 70)s, (50 180)s (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min ± 1 ± 1 100 500 (A1-A2) ± 5 ± 5 100 10 3 60 10 3 10 +50 10 +50 IP 20 IP 20

Ordering information Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12 240)V AC/DC. 80 Series - Modular timers 1-6 - 8-16 A 8 0. 0 1. 0. 2 4 0. 0 0 0 0 Series Type 0 = Multi-function (AI, DI, SW, BE, CE, DE) 1 = On-delay (AI) 2 = Interval (DI) 4 = Off-delay with control signal (BE) 6 = Power off-delay (True off-delay) (BI) 7 = Multi-function with solid state output (AI, DI, SW, BE, CE, DE) 8 = Star-delta (SD) 9 = Asymmetrical flasher (LI, LE) Versions 0 = Standard Supply voltage 240 = (12... 240)V AC/DC (, 80.91) 240 = (24... 240)V AC/DC (80.11, 80.21, 80.41,, 80.82) 240 = (24...240)V AC, (24...220) (80.61) Supply version 0 = AC (50/60 Hz)/DC No. of poles 1 = 1 CO (SPDT) 1 = 1 NO (SPST-NO), type only 2 = 2 NO (DPST-NO), type 80.82 only Insulation Dielectric strength /11/21/41/82/91 80.61 between input and output circuit V AC 4,000 2,500 2,500 between open contacts V AC 1,000 1,000 Insulation (1.2/50 µs) between input and output kv 6 4 4 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kv air discharge EN 61000-4-2 8 kv Radio-frequency electromagnetic field (80 1,000 MHz) EN 61000-4-3 10 V/m Fast transients (burst) (5-50 ns, 5 khz) on Supply terminals EN 61000-4-4 4 kv Surges (1.2/50 µs) on Supply terminals common mode EN 61000-4-5 4 kv differential mode EN 61000-4-5 4 kv on start terminal (B1) common mode EN 61000-4-5 4 kv differential mode EN 61000-4-5 4 kv Radio-frequency common mode (0.15 80 MHz) on Supply terminals EN 61000-4-6 10 V Radiated and conducted emission EN 55022 class A Other data Current absorption on signal control (B1) < 1 ma Power lost to the environment without contact current W 1.4 with rated current W 3.2 Screw torque Nm 0.8 Max. wire size solid cable stranded cable mm 2 1x6 / 2x4 1x4 / 2x2.5 AWG 1x10 / 2x12 1x12 / 2x14 Accessories Sheet of marker tags, for types 80.82, plastic, 24 tags, 9x17 mm 020.24 020.24 060.72 Sheet of marker tags, for types /11/21/41/61/71, plastic, 72 tags, 6x12 mm 060.72 5

80 Series - Modular timers 1-6 - 8-16 A Outline drawings 80.11 80.21 80.41 80.91 80.61 80.82 6

80 Series - Modular timers 1-6 - 8-16 A Functions U = Supply voltage S = Signal switch = Output contact LED* Supply voltage OFF NO output contact Open Open 15-18 Contacts Closed 15-16 ON Open 15-18 15-16 ON Open (Timing in Progress) 15-18 15-16 ON Closed 15-16 15-18 * The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED is not illuminated. Without control signal Type Without control signal = Start via contact in supply line (A1). With control signal = Start via contact into control terminal (B1). (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). With control signal (BE) Off-delay with control signal. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. (CE) On- and off-delay with control signal. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. NOTE: The function must be set before energising the timer. Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 7

80 Series - Modular timers 6-8 - 16 A Functions Without control signal Type 80.11 (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 80.21 (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80.11/21/61 80.61 (BI) Power off-delay (True off-delay). Apply power to timer (minimum 500). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 80.82 With control signal 80.82 80.41 (SD) Star-delta. Apply power to timer. The star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further transfer time variable from (0.05 1)s the delta contact ( Δ ) closes and remains in that position, until reset on power off. (BE) Off-delay with control signal. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. 80.41 Without control signal 80.91 (LI) Asymmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ON (T1) and OFF (T2) times are independently adjustable. 80.91 With control signal (LE) Asymmetrical flasher (starting pulse on) with control signal Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON (T1) and OFF (T2), until opened. 80.91 Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. 8 * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12