DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE



Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

HYDRAULIC PIPING STANDARD HANDBOOK. Revision 1

Fuel Treatment and Conditioning Systems

Customer environment. Customers

ALFAGOMMA GROUP HISTORY

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

DET NORSKE VERITAS EC TYPE-EXAMINATION CERTIFICATE

Caterpillar Fluid Systems Srl HYDRAULIC HOSE & COUPLINGS

OIL & MARINE PRODUCT RANGE. Dock & onshore Floating roof tank drain Mooring Rig supply

INTEC Engineering GmbH Heating Solutions for the Marine Industry

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Drain & Sewer. Cleaning. Drain and Sewer cleaning Fluid transfer solutions TRELLEBORG FLUID HANDLING SOLUTIONS

General Description of The CMC- Services

Parker Subsea Drilling. BOP Umbilicals, Hotlines and Stack Hoses

Hydraulics CONTENT

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

3/2-way Solenoid Valve, direct-acting, NC or NO

DNVGL-RU-0050 Edition October 2014

FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES

Seamless stainless tubes for hydraulic and instrumentation systems

F l u i d M a n a g e m e n t S o l uti o n s fo r t h e A e rospace Industry

Ergonomical Polyurethane recoil hose

Rev Pag. TRECCIATO.. 1 Braided. SPIRALATO Spiral. TESSILE.. 33 Textile. TERMOPLASTICO.. 47 Thermoplastic. SPECIALI..

Automatic Bypass Control AVDO

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Aeroquip Series 1800 & 1801 Low Profile Ratchet Lock Couplings. Lightweight Self-Sealing Compact Design Minimum Pressure Loss

hydraulic hoses, couplings & equipment the world of Hose

SERVICE PARTS LIST AND ASSEMBLY INSTRUCTIONS

Flow divider (flow distributor), type TQ

Thermostatic valve Type AVTA

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

NAUTICUS HULL USER MANUAL GETTING STARTED DET NORSKE VERITAS WITH NAUTICUS HULL RULE CHECK

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

DNV Managing Risk. DNV corporate presentation. Tor E. Svensen, COO DNV Maritime 26 June 2008

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE

Technical information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Armaturenwerk Hötensleben GmbH. AWH-Connect

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

3/2- and 2/2-way cartridge valve type BVE

Ingersoll-Rand LIFTSTAR. Manriding Winches. Classification and compliance with safety requirements

HOSE, TUBE, AND PIPE CLAMPS

Electronic Pressure Switch EDS 300

Application Data Important Safety Information

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

PRODUCT CATALOGUE OFFSHORE. RCONTAINER AS PHONE: ADDRESS: Industrivegen 11, 2166 Oppaker OFFSHORE 1

Integrated Custom Systems

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

TYPE CERTIFICATION OF WIND TURBINES

Tubo altissima pressione / Very high pressure hose

Metal Pressfitting Pipe Systems

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Steel for wind power applications

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Workshop Compressors CLASSIC Series

VALVES FOR REFRIGERATING SYSTEMS

creating progress for the future

Very high pressure hoses. Tubo altissima pressione / Very high pressure hose

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Light-Weight Panels. High quality panels.

psens Pressure Measurement

servo-controlled 3-WaY vacuum solenoid valves WiTH

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

BULKSTREAM A160HW Series Multipurpose Suction & Delivery Hose

Festoon 715 P PUR cable for flexible application in festoon systems

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

For the transfer of : Oil Solvents Liquid Chemicals Acids Cryogenic Products Vapour

BG Millag ApS Egegårdsvej 5 DK-5260 Odense S Tlf.: info@millag.dk

Threaded Resistance Thermometers Model TR10-D, Miniature Design

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Hydraulic Control Solutions

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Via Stelvio, Marnate (VA), Italy Tel Fax info@italcontrol.net - Website:

OIL CONSOLE. Lube-,Seal-, & Control Oil Systems. Issued:

Data sheet ECC 12 and 22

QUALITY & TECHNICAL CERTIFICATIONS

Rickmeier Solutions. Gear pumps for superior Lubrication

Jobson THE RIGHT CONTACT

GUARDRAIL POST STEEL

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Automatic Back-Flushing Filter AutoFilt RF9.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Tubular solutions for the Solar Power Industry Rise in success with precision

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

OptiFlo. Air Operated Diaphragm Pumps

CNG & Hydrogen Tank Safety, R&D, and Testing

1805 Series Relief Valves

Engineering & Testing Services. Hydraulic Fitting Design and Hydro-Mechanical Testing

STENCA HT PIPE. Quality Insulation made of calcium silicate.

Transcription:

Pagina 1 di 6 DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. P-12685 This Certificate consists of 6 pages This is to certify that the Flexible Hoses of Non-Metallic Material with Permanently Fitted Couplings 791.70 with type designation(s) Flexor 1ST, -1A, -1SN, -1AT, Flexopak 2, Flexor 2ST, -2A, - 2AT, -2SN, 122T, 122G, 222T, 222G Manufactured by ALFAGOMMA HYDRAULIC SPA CASTELNUOVO VOMANO, Italy is found to comply with Det Norske Veritas' Rules for Classification of Ships Offshore Standard DNV-OS-D101, Marine and Machinery Systems and Equipment Det Norske Veritas' Standards for Certification 2.9 No. 5-791.70 Application Hydraulic and Pneumatic systems (incl. power and control for steering gears)/fuel Oil/Lube Oil/Compressed Air/Fresh Water/Sanitary. 122T and 122G, sizes 1/4" to 3/4" may be used as connection between valves and manifolds on high pressure CO2 systems Type: Temperature range: Max. working press.: Sizes: Flexor 1ST, -1A, - 1SN, -1AT -40 C to 125 C (see 40 to 225 bar (dep. Flexopak 2-40 C to 125 C (see 112 to 400 bar (dep. DN6 to 31mm (1/4" to

Pagina 2 di 6 1-1/4") Flexor 2ST, -2A, - 2AT, -2SN -40 C to 125 C (see 80 to 400 bar (dep. 122T, 122G -40 C to 125 C (see 40 to 225 bar (dep. 222T, 222G -40 C to 125 C (see 80 to 400 bar (dep. Place and date This Certificate is valid until Høvik, 2008-01-31 2009-12-31 for Det Norske Veritas AS Hanne Anita Hjerpetjønn Local Office Øyvind Skåra Head of Section DNV Milan Surveyor Product description Alfagomma Type designations: Flexor 1ST acc. EN 853 and 100R1A acc. SAE J517 (skive) Flexor 1SN acc. EN 853 and 100R1AT acc. SAE J517 (non-skive) Dunlop Hiflex Type designations: 122T, 122G acc. EN 853 1SN Design: Flexible rubber hoses reinforced by one steel wire braid. Tube: Oil resistant synthetic rubber nitrile. Reinforcement: One, high tensile steel wire braid. Cover: Chloroprene rubber, weather-, oil- and abrasion resistant. Couplings: Carbon steel (9SMnPb28 acc. UNI 4838) or Stainless Steel (XCrNi18 10 acc. UNI 6901) Alfagomma Type designations: Flexor 2ST acc. 2ST in EN 853 and 100R2A in SAE J517 (skive) Flexor 2SN acc. 2SN in EN 853 and 100R2AT in SAE J517 (non-skive) Dunlop Hiflex Type designations: 222T, 222G acc. EN 853 2SN Alfagomma Type designation : Flexopak 2 acc. 2SC in EN857 (DN 25), 100R16 acc. SAE 517 (DN32) Design: Flexible rubber hoses reinforced by two steel wire braids. Tube: Oil resistant synthetic rubber nitrile. Reinforcement: Two high tensile steel wire braids. Cover: Chloroprene rubber, weather-, oil- and abrasion resistant. Couplings: Carbon steel. Manufacturing plants:

Pagina 3 di 6 Couplings Alfatechnology S.r.l. Zona Industriale Piano Lago 87050 Mangone (CS) Alfatechnology S.r.l. Via dell'industria, 12 20040 Bellusco (MI) Hoses Alfagomma Hydraulic S.p.A. Via Enrico Mattei no.6 64020 - Castelnuovo Vomano (TE) Alfagomma Hydraulic S.p.A. Area Industriale Piano Lago 87050 Figline Vegliaturo (CS) Hose/fitting combinations: Flexor 1ST, -1A, -1SN, -1AT, 122T, 122G DN FERRULE INSERT [inch] [mm] Carbon Steel Stainl. Steel Carbon Steel Stainl. Steel 1/4 6 H1100204-04 H3100204-04 H12-04 H32-04 5/16 8 H1100204-05 H3100204-05 H12-05 H32-05 3/8 10 H1100204-06 H3100204-06 H12-06 H32-06 1/2 12 H1100204-08 H3100204-08 H12-08 H32-08 5/8 16 H1100204-10 H3100204-10 H12-10 H32-10 3/4 19 H1100204-12 H3100204-12 H12-12 H32-12 1 25 H1100204-16 H3100204-16 H12-16 H32-16 1 1/4 31 H1100104-20 H3100104-20 H12-20 H32-20 1 1/2 38 H1100104-24 H3100104-24 H12-24 H32-24 2 51 H1100104-32 H3100104-32 H12-32 H32-32 Hose/fitting combinations: Flexopak 2, Flexor 2ST, -2A, -2AT, -2SN, 222T, 222G DN FERRULE INSERT [inch] [mm] Carbon Steel Stainl. Steel Carbon Stainl. Steel Steel 1/4 6 H1100204-04 H3100204-04 H12-04 H32-04 5/16 8 H1100204-05 H3100204-05 H12-05 H32-05 3/8 10 H1100204-06 H3100204-06 H12-06 H32-06 1/2 12 H1100204-08 H3100204-08 H12-08 H32-08 5/8 16 H1100204-10 H3100204-10 H12-10 H32-10 3/4 19 H1100204-12 H3100204-12 H12-12 H32-12 1 25 H1100204-16 H3100204-16 H12-16 H32-16 1 1/4 31 H1100204-20 H3100204-20 H12-20 H32-20 H1100104-20 *) H3100104-20 *) 1 1/2 38 H1100204-24 H3100204-24 H12-24 H32-24 2 51 H1100204-32 H3100204-32 H12-32 H32-32 *) - Flexopak 2 Couplings are fitted to the hoses at: Alfatechnology S.r.l.

Pagina 4 di 6 Application/Limitation The type approval is valid also for distributors authorised by Alfagomma Hydraulic Hose South S.p.A to fit the couplings to the hoses when same specifications, tolerances, equipment and quality control procedures are used. The following companies are given the authorisation: Dunlop Hiflex UK Ltd. PO Box 87, Dunlop Hiflex Oy Leyland Business Park, Vapaalantie 8 Centurion Way, 01650 Vantaa Farington, Leyland. FINLAND PR25 3WL Dunlop Hiflex AB Dunlop Hiflex Norway Seldonsvägen 2 Stanseveien 30 Postbox 536 Postboks 175 Kalbakken S-301 80 Halmstad N-0903 OSLO SWEDEN NORWAY Dunlop Fluidtechnik GmbH Dunlop Hiflex A/S Pforzheimer Str. 126 Industrisvingen 5 76275 Ettlingen Postboks 195 GERMANY DK-2605 BRØNDBY Maximum working pressure (MWP): DENMARK DN [inch] [mm] Flexor 1ST, -1A, -1SN, - 1AT, 122T, 122G MWP[bar] Flexor 2ST, -2A, -2AT, -2SN, Flexopak 2 222T, 222G ¼ 6 225 400 400 5/16 8 215 350 375 3/8 10 180 330 350 ½ 12 160 275 310 5/8 16 130 250 280 ¾ 19 105 215 240 1 25 88 165 185 1 ¼ 31 63 125 112

Pagina 5 di 6 1 ½ 38 50 90-2 51 40 80 - Temperature range: -40 to 100 ºC continuos operation. Maximum peak temperature 125 ºC. Hoses used for continuous operation at temperatures higher than 100 C will have their lifetime reduced. In such cases more frequent inspections and planned exchange should be a part of the maintenance program. For compressed air or gases above 16 bar the cover should be pin prickled. Flexible hoses are only to be used in lengths up to 2 meters where it is necessary due to vibrations or flexible mounting of the machinery. The hoses shall not replace/be used where permanent piping is possible/required. The hoses must only be fitted in places where they are always accessible. Flexible hoses of these types are not to be used in boiler fronts. The hoses are to be mounted in accordance with the manufacturer's instructions. It must be possible to shut off from the system all flexible hoses used in systems for compressed air, lube oil, fuel oil and petroleum base hydraulic oil. Each hose is to be hydraulic pressure tested to 1.5 times the maximum working pressure and to be delivered with manufacturer's pressure test certificate. Hose assemblies with couplings made of carbon steel are not to be used at temperatures below -10 C unless the material is normalized. Type Approval documentation Tests carried out Dimensional Check Test, Change in Length Test, Burst Test, Cold Flexibility Test, Ozone Resistance Test, Impulse Test, Oil Resistance Test according to EN853 and SAE J517 respectively and Fire Test according to ISO 15540. Burst test at - 60 C qualifying 122T and 122G: 3/16" to 3/4" for CO 2 Marking of product For traceability to this type approval, the final products (hoses with couplings) are to be marked: Manufacturer's name or trademark and type designation: - Alfagomma ( ) Flexor 1ST, -1A, -1SN, -1AT; Flexopak 2; Flexor 2ST, -2A, -2AT, -2SN

Pagina 6 di 6 - Dunlop Hiflex ( ) 122T, 122G or 222T, 222G Additional marking at manufacturer's option. Certificate retention survey For retention of the Type Approval, DNV Surveyor shall perform a survey every second year, to verify that the conditions for the type approval are complied with and to witness the following tests on a selection of sizes: - Dimensional check. - Change in length - Leakage test - Burst test The tests shall be performed in accordance with procedures given in Det Norske Veritas' Certification Notes no. 2.9-5-791.70 "Type Approval of Flexible Hoses of Non-Metallic Material" or another recognised standard. The tests are to be performed with the type of couplings fitted that are Type Approved with the hoses. Hoses from all manufacturing plants mentioned in this certificate are to be tested. END OF CERTIFICATE Notice: This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million.in this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. DET NORSKE VERITAS AS VERITASVEIEN 1, 1322 HØVIK, NORWAY TEL: (+47) 67 57 99 00 FAX: (+47) 67 57 99 11