4077 AIRPARK DRIVE STANDISH, MICHIGAN 48658 PHONE 989-846-4583 800-248-0278 FAX



Similar documents
Technical Data. Installation

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Part I - Installation

HIGH VELOCITY WATER SPRAY NOZZLE

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

FIVE YEAR CERTIFICATION REPORT

08.08 Vic-Check Valves

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures.

Model/Sprinkler Identification Numbers

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

FOAM CHAMBER MODEL - FC

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

The conditions below apply to the curves shown on the following pages.

Design & Construction Standards, Revised January

Installation Manual DIAPHRAGM WELL TANK

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

HotLok Pass Through Blanking Panel

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

3M Housings DS Series

Baumann Flexsleev Sanitary Control Valve

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

TABLE OF CONTENTS 11.0 WARRANTY

Wet alarm valves. Wet alarm valves. FM trim

Terms and Conditions

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

VALVES FOR REFRIGERATING SYSTEMS

APCO SLOW CLOSING AIR/VACUUM VALVES

PRESSURE REDUCING CONTROL VALVE

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Installation Instructions

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

GD Valves Rubber Lined - Centric Fout! Onbekende naam voor documenteigenschap. PRODUCT DATA. General Description BUTTERFLY VALVE

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Style 9168 Field Service Kit Black Max Piston intake valve

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Original instructions Tina 3A/Aps Adaptor unit

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Quick response concealed horizontal sidewall sprinkler

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

SSNICLRG SSNICSM PLNICLRG PLNICSM

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Sprinkler Guards Model C Model D

Engineering Specifications

Price List January 1, 2015

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

Tina 2A/B Adaptor unit

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

BWX SERIES BUTTERFLY VALVE FOR CRYOGENIC APPLICATIONS

Wafer, Semi-Lug, Lug and Double Flanged Type

Threaded Inline Air Heaters

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Scotch-Weld PUR Easy 250 Adhesive Applicator

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Scraper Passage Indicator. Electrical Indicator. Features

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

PROTECTO 401 Price List

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Centro-Matic Automatic Lubrication Systems System Controls

FIRE PROTECTION VALVES Price Sheet FPVLV-7.15 Effective: July 6, 2015 Cancels Price Sheet FPVLV-2.15 of February 2, 2015

VK-250 WARRANTY REGISTRATION FORM

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

MODEL MAC-3 MULTIPLE APPLIANCE CONTROL

WATER VALVE OWNER S MANUAL REV051811

For Models #6-5001, #6-7501, # & #10-12K1

Advantium 2 Plus Alarm

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

BERMAD Fire Protection

Automatic Fire Sprinkler Submittal Requirements

Transcription:

Butterfly Valves 4077 AIRPARK DRIVE STANDISH, MICHIGAN 48658 PHONE 989-846-4583 800-248-0278 FAX 989-846-9231 www.globesprinkler.com MAY 2013 L-1 BULLETIN BUTTERFLY REV. #5

GLOBE BUTTERFLY VALVE INSTALLATION AND MAINTENANCE GUIDE Table of Contents Page Design Requirements and Installation 1 Care and Maintenance 1 GL175T 2 GL175G 3 GLR300G 4 GL300W 5 Friction Loss 6 Product Warranty 7 MAY 2013 Pagei BULLETIN BUTTERFLY REV. #5

GLOBE BUTTERFLY VALVE INSTALLATION AND MAINTENANCE GUIDE Design Requirements The Globe grooved butterfl y valve should be connected to the piping system with approved couplings or fl ange adapters. Flow may be from either direction, and the valve may be positioned in any direction. Globe butterfl y valves have been designed with a slow close hand wheel operator, which effectively minimizes water hammer. These valves feature minimum fl ow restriction and pressure loss when in the fully open position. Installation When the valves are received from the manufacturer they should be handled carefully to avoid breakage and damage to the seating area. Before installation of the valve, clean piping, fl ange and coupling. When the valve closes hard, it is usually due to debris lodged in the sealing area. Often this may be corrected by backing off the hand wheel and closing again. The valve should never be forced to seat by applying a wrench to the hand wheel as this may distort the valve components or score the sealing surface. The use of excessive force to open or close the valve violates all warranties whether express or implied. The inlet and outlet pipe adjacent to the valve should be properly supported to prevent excessive stress on the valve body. The valves should not be used to force a pipeline into position as this may result in distortion of the valve body. Conduit and electrical connections to the optional tamper switch must be in accordance with National Electrical Code (NFPA 72) and requirements of the local authority having jurisdiction. Care and Maintenance Globe butterfl y valves require no regular maintenance, however, it is advisable to inspect and verify proper operation of the unit annually or in accordance with the authority having jurisdiction. The inspection should include a visual check for leakage at the valve pipe connection and body to operator connection. Inspection and maintenance should be performed by a qualifi ed inspection service. Switch Installation Globe butterfl y valves are provided with internal supervisory position switches. The tamper switch operates by a cam connected to the valve stem. The switch will change position within two (2) full turns of the hand wheel from the fully open position. Switch #1 For connection to the supervisory circuit. Normally closed: 2 Red Normally open: 2 Yellow Common: 2 White Switch #2 Auxiliary switch connected per authority. Normally closed: 1 Orange Normally open: 1 Blue Common: 1 Black Ground Lead: 1 Green FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT VOLTAGE SOURCE COMMON (WHITE) OPEN (YELLOW) CLOSED (RED) END OF LINE RESISTOR OR NEXT DEVICE MAY 2013 Page 1 BULLETIN BUTTERFLY REV. #5 S-1 ACTUATOR CASE GROUND S-2 COMMON (BLACK) NOTES 1.RATED:5A-1/6HP-125/250V (GREEN) OPEN (BLUE) CLOSED (ORANGE) Shown with valve in closed position. AUX. DEVICE (BELL OR HORN)

GL175T Bronze Butterfly Valves Threaded End, Sizes : 1", 1 ¼", 1 ½", 2" and 2 ½" Specifications: Working Pressure : Max. Test Pressure : Max. Working Temp. : 175 PSI (12.5 Bars) 350 PSI (25.0 Bars) 250 F (120 C) Factory Installed UL Listed Double Tamper Switch for Indoor and Outdoor Use. Materials of Primary Components Body : ASTM B-505 Disc : ASTM B-584 EPDM Encapsulated Upper Stem : ASTM A-564 Type XM 12 Lower Stem : ASTM A-564 Type XM 12 Gear Housing, Cover : ASTM A-619 Hand Wheel : ASTM A-619 Flag Indicator : ASTM B-16 York Mechanism : ASTM A-283 Stem Bushing : ASTM B-16 Conduit Connector : ASTM A-307 O-Rings (All) : Cover Gasket : NBR 4.02 (102.0) Approvals: culus Listed FM Approved NYC - DOB MEA 155-06-E 2.32 (59.0) C B 3.72 (94.5) A DIMENSION UNIT: IN (mm) SIZE A B C Part No. 1" 2.16 (54.8) 2.06 (52.4) 1.48 (37.6) 311725-G 1 ¼" 2.68 (67.9) 2.25 (57.2) 1.63 (41.4) 311735-G 1 ½" 2.94 (74.6) 2.38 (60.3) 2.50 (63.5) 311745-G 2" 3.31 (84.2) 2.56 (65.1) 1.97 (50.0) 311755-G 2 ½" 4.16 (105.6) 2.75 (69.9) 2.19 (55.6) 311760-G MAY 2013 Page 2 BULLETIN BUTTERFLY REV. #5

GL175G Bronze Butterfly Valves Grooved End, Sizes : 2" and 2 ½" Specifications: Working Pressure : Max. Test Pressure : Max. Working Temp. : 175 PSI (12.5 Bars) 350 PSI (25.0 Bars) 250 F (120 C) Factory Installed UL Listed Double Tamper Switch for Indoor and Outdoor Use. Materials of Primary Components Body : ASTM B-505 Disc : ASTM B-584 EPDM Encapsulated Upper Stem : ASTM A-564 Type XM 12 Lower Stem : ASTM A-564 Type XM 12 Gear Housing, Cover : ASTM A-619 Hand Wheel : ASTM A-619 Flag Indicator : ASTM B-16 York Mechanism : ASTM A-283 Stem Bushing : ASTM B-16 Conduit Connector : ASTM A-307 O-Rings (All) : Cover Gasket : NBR 4.02 (102.0) Approvals: culus Listed FM Approved NYC - DOB MEA 155-06-E 2.32 (59.0) A C 3.72 (94.5) B DIMENSION UNIT: IN (mm) SIZE A B C Part No. 2" 1.97 (50.0) 4.56 (115.8) 3.62 (91.9) 311765-G 2 ½" 2.18 (55.4) 4.56 (115.8) 3.81 (96.8) 311775-G MAY 2013 Page 3 BULLETIN BUTTERFLY REV. #5

GLR300G Grooved Butterfly Valves Grooved End, Sizes : 2 ½", 65mm, 3, 4, 6, 150mm, 8 Specifications: Working Pressure : Max. Test Pressure : Max. Working Temp. : 300 PSI (21.4 Bars) 600 PSI (42.8 Bars) 250 F (120 C) Factory Installed UL Listed Double Tamper Switch for Indoor and Outdoor Use. Materials of Primary Components Body : Disc : ASTM A-536 Nylon-11 Coated ASTM A-536 EPDM Encapsulated AISI 420-SS AISI 410-SS Upper and Lower Stems : Worm Gear Shaft : Housing : ASTM A-536 Hand Wheel : ASTM A-536 Flag Indicator : ASTM A-536 Sheer Pin : ASTM A-510 Segment Gear : ASTM B-148 or B-584 Housing Gasket : O-Rings (All) : A Approvals: culus Listed FM Approved NYC - DOB MEA 155-06-E B E 5.00 (127.0) MAY 2013 Page 4 BULLETIN BUTTERFLY REV. #5 C DIMENSION D UNIT: IN (mm) 4.37 (111.0) SIZE A B C D E Part No. 2 ½" 5.31 (134.9) 5.06 (128.5) 4.13 (104.9) 3.31 (84.1) 3.81 (96.8) 311785-G 65mm (76mm PIPE O.D.) 5.31 (134.9) 5.06 (128.5) 4.13 (104.9) 3.31 (84.1) 3.81 (96.8) 311785-GD 3" 5.59 (142.0) 5.06 (128.5) 4.41 (112.0) 3.61 (91.7) 3.81 (96.8) 311790-G 4" 6.88 (174.8) 5.06 (128.5) 5.71 (145.0) 4.31 (109.5) 4.53 (115.1) 311795-G 6" 8.25 (209.6) 8.66 (220.0) 7.06 (179.3) 5.71 (145.0) 5.22 (132.6) 311805-G 150mm (165mm PIPE O.D.) 8.25 (209.6) 8.66 (220.0) 7.06 (179.3) 5.71 (145.0) 5.22 (132.6) 311805-GD 8" 9.22 (234.2) 8.66 (220.0) 8.03 (204.0) 6.71 (170.4) 5.81 (147.6) 311815-G

GLR300W Wafer Type Butterfly Valves Wafer Type End, Sizes : 2 ½", 3, 4, 6 and 8 Specifications: Working Pressure : Max. Test Pressure : Max. Working Temp. : 300 PSI (21.4 Bars) 600 PSI (42.8 Bars) 250 F (120 C) Factory Installed UL Listed Double Tamper Switch for Indoor and Outdoor Use. Materials of Primary Components Body : Disc : ASTM A-536 Nylon-11 Coated ASTM A-536 EPDM Encapsulated AISI 420-SS AISI 410-SS Upper and Lower Stems : Worm Gear Shaft : Housing : ASTM A-536 Hand Wheel : ASTM A-536 Flag Indicator : ASTM A-536 Sheer Pin : ASTM A-510 Segment Gear : ASTM B-148 or B-584 Housing Gasket : O-Rings (All) : A Approvals: culus Listed FM Approved NYC - DOB MEA 155-06-E B E 5.00 (127.00) C D 4.37 (111.0) DIMENSION UNIT: IN (mm) SIZE A B C D E Part No. 2 ½" 6.55 (166.4) 5.31 (134.9) 5.35 (135.9) 3.44 (87.4) 1.81 (46.0) 311836-G 3" 6.81 (173.0) 5.31 (134.9) 5.63 (143.0) 3.66 (93.0) 1.81 (46.0) 311839-G 4" 7.31 (185.7) 5.31 (134.9) 6.13 (155.7) 4.28 (108.7) 2.06 (52.3) 311846-G 6" 8.58 (217.9) 8.66 (220.0) 7.41 (188.2) 5.67 (144.0) 2.20 (55.9) 311861-G 8" 9.92 (252.0) 8.66 (220.0) 8.75 (222.3) 6.53 (165.9) 2.28 (57.9) 311871-G MAY 2013 Page 5 BULLETIN BUTTERFLY REV. #5

Grooved End Flow Characteristics 1.2 NORMAL PRESSURE DROP IN POUNDS PER SQUARE INCH (psi) 1.0 0.8 0.6 0.4 0.2 0.0 2½" 3" 4" 6" 8" 100 1,000 10,000 FLOW RATE IN GALLONS PER MINUTE (GPM) Wafer and Grooved End Friction Loss Valve Model DW (Wafer) Valve Size Inches (mm) Friction Loss in Equivalent Feet of Pipe Valve Model Valve Size Inches (mm) Friction Loss in Equivalent Feet of Pipe 2½ (65) 4.8 2½ (65) 6.9 3 (76.2) 3.5 3 (76.2) 4.1 4 (100) 2.4 DG (Grooved) 4 (100) 3 6 (150) 5.1 6 (150) 5.5 8 (200) 5.4 8 (200) 5.4 Grooved End Flow Coeffi cient : CV DN (mm) SIZE (in) Disk Open Angle 30 40 50 60 70 80 90 65 2 ½" 12 27.4 53.1 96 138 156 163 80 3" 18.9 39.4 78.9 144 210 243 249 100 4" 30 65.1 129 226 377 488 514 150 6" 84 184 369 634 964 1196 1286 200 8" 165 339 677 1230 2002 2850 3129 Wafer Type Flow Coeffi cient : CV at full open DN (mm) 65 80 100 150 200 SIZE (in) 2½" 3" 4" 6" 8" CV 222 389 1000 1998 4619 MAY 2013 Page 6 BULLETIN BUTTERFLY REV. #5

GLOBE WARRANTY Listed and approved sprinkler products and devices manufactured by Globe Fire Sprinkler Corporation are produced in strict accordance with standard quality control procedures. We warrant our products to be free from defects in material and workmanship under normal use and service. Our obligation under this warranty shall be limited to replacing, at our plant, any parts thereof which shall, within one year after delivery to the ORIGINAL PURCHASER, be demonstrated to be defective. In order to accomplish demonstration of defectiveness, the parts claimed to be defective must be sent by the original purchaser to Globe Fire Sprinkler Corporation, 4077 Airpark Drive, Standish, MI 48658. Globe's warranty does not extend to incidental or consequential damages of any nature. In no event shall Globe Fire Sprinkler Corporation be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether Globe Fire Sprinkler Corporation was informed about the possibility of such damages, and in no event shall Globe Fire Sprinkler Corporation liability exceed an amount equal to the sales price. THIS WARRANTY IS IN LIEU OF ALL OTHER WAR- RANTIES, EXPRESS OR IMPLIED INCLUDING MERCHANT ABILITY AND FITNESS for purpose intended. No person, fi rm or corporation is authorized to assume for us any other liability in connection with the sale of our products. MAY 2013 Page 7 BULLETIN BUTTERFLY REV. #5