ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks



Similar documents
ABLOY EL420, EL520 Europrofile motor locks



ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DC 240 DOOR CLOSER Heavy duty door closer

Narrow stile lock 1314

Modular mortice locks

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

ABLOY VEGA CABINET LOCKS

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions


An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

What locks do I have Timber Doors

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Mechanical Digital DX Locks

Lock Function Chart Page 1 of 7

Technical Information

EC-Certificate of Conformity Certificate CPD

Euro Profile Mortice Locks

KEY CYLINDER PLATFORMS

Digital Keypad Use s Manual

Series 300 / 200. Mortice locks for timber doors

PHA 2000 PHB 3000 EXIT PAD

CISA Safe Home. Locks for shutters and security grates

Mechanical Entry Locksets

CREATING LOCKING SOLUTIONS...

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ScanFlex lever handles

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

Combi B Alarm box. Mounting instructions

Key in Knob & Key in Lever

D.A.C.S. Door Access Control System

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

Panic & emergency exit devices

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Protect your home with

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

YALE DIGITAL DEADBOLT

Adaptability to Enhanced Security

An overview of mechanical lock and security related standards and why they re important to the Insurance Industry

Adaptability to Enhanced Security

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CMPD Home Security Newsletter

Relevant British, European and International standards

Basic Technical Fundamentals of Builders Hardware

Concealed Door Closers

Lockwood Digital Deadbolt

HERZ-Thermal Actuators

Hortonville School District Door Control System Phase I Request for Proposal July 5th, 2013

TS93 EMR T/PT/TDE. Surface applied door closer

Electromagnetic Locking

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

product brochure IMPLEMENTED

a practical guide to home security.

EMF/EMR. Holder/Release Devices with Integral Door Closers

COASTAL SERIES. 316 Solid Stainless Steel Door Furniture

INSTALLATION MANUAL XM3 Reader

BURGLARY PREVENTION FOR HOMES

Securing your school. Door hardware solutions for primary education

Medium voltage arc flash eliminator units VAM 3ED,

FAA077A2EMEI IIssued EntreMatic Swing Door Operator EMSW USER S MANUAL

Door Hardware Lock Specifications

Stove Guard Kit User Manual

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

PAC1 Door Access Controller

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Security Screen Door Hardware

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Drayton Digistat +2RF/+3RF

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

USER MANUAL V5.0 ST100

Simplex 1000 Series. All Simplex Controls are less I.C. core Series packed with both ASA and T strike.

bts 80 f/emb/flb/bsr Floor spring system

CISA esigno Contactless Lock

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ALWAYS THE SAFE CHOICE! Electronic door locking systems.

9300BC SERIES Light Commercial Door Closer

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Battery 12. Battery FAQ 13

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

ASSA HIGH SECURITY LOCKS ASSA Twin ASSA Twin 6000, Twin Exclusive & V10. ASSA cylinders can be supplied in the following keying forms:

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Camlocks and Cupboard Locks

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Assisted lift operated 2/2-way solenoid valves Type EV250B

DX Mechanical Digital Door Locks Service Manual. ASSA ABLOY, the global leader in door opening solutions

Standard Door Specification

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transcription:

EL460, EL461, EL560, EL561 Europrofile handle controlled locks Europrofile locks offer intelligent solution for medium traffic doors. Locks can be installed with long plates or roses. An ASSA Group brand

Convenience, High security, High durability - Europrofile handle controlled locks APPLICATIONS The locks are recommended to be used in the interior doors of business premises, public buildings, hospitals, educational premises etc. Typical applications are the doors of: - Offices - Meeting rooms - Storage rooms - Technical maintenance rooms - Consulting rooms - Fire doors (medium traffic) EL560 and EL561 are used in wooden and metal doors. EL460 and EL461 are used in narrow profile doors. EL560 or EL460 with split spindle is chosen, when exit by handle is needed. EL561 or EL461 is used, when both access and exit are electrically controlled. Handle controlled locks are best suited in medium traffic doors. The locks can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button. The locks can be used both in exit and fire rated doors (EN). The locks are not suitable for use with door automatics. Also available: - Microswitch locks EL360 for wooden and metal doors EL260 for narrow profile doors - Mechanical locks EL160 for wooden and metal doors EL060 for narrow profile doors Also available lock cases for Swiss cylinder (RZ): - EL562 (split spindle), EL563 (through spindle) for wooden and metal doors - EL462 (split spindle), EL463 (through spindle) for narrow profile doors - EL362 microswitch lock for wooden and metal doors - EL262 microswitch lock for narrow profile doors - EL162 mechanical lock for wooden and metal doors - EL062 mechanical lock for narrow profile doors FUNCTION Handle controlled locks can be set to function as fail locked or as fail unlocked. In the fail locked setting, the lock can be opened by controlled handle when power is on, and it can not be opened by controlled handle, when power is off. In the fail unlocked setting, the electrical function is the opposite. EL560 and EL460 Only outside handle is electrically controlled. The lock can always be opened by inside handle. Mechanical opening by cylinder is always possible. EL561 and EL461 Both inside and outside handles are electrically controlled. Mechanical opening by cylinder or thumbturn is always possible. STANDARDS EN STANDARDS EN 179:0 EN 1125:0 EN 1634-1 EN 61000-6-1:07 EN 61000-6-3:07 EN 129:04 LOCAL STANDARDS NEN 509:1995 GOST-R Exit Panic exit Fire resistance EMC EMC Mechanical resistance SKG, mechanical strength and burglary resistance STANDARD DELIVERY OPENING DIRECTIONS (HANDINGS) DIN 1 Right inwards Left inwards 2 Left inwards Right inwards 3 Left outwards Left outwards 4 Right outwards Right outwards 4 1 2 3 Standard delivery includes: - Lock case with opening direction 4 or 2,4 - Fixing screws - Spindle adapters - Lock case manual Please specify when ordering: - Lock type - Backset - Forend - Strike plate - Split spindle EA2 or EA29 (EL460 and EL560)

TECHNICAL DETAILS Operating voltage: 12 24 V DC STAB (-10%, +15%) Current: Max. 0.55 A (12V DC), 0.27 A (24V DC) Idle 0.24 A (12V DC), 0.11 A (24V DC) Microswitches: Max. 0.5 A 30 V AC/DC resist, 10 W Operating temperature: - C - +60 C Bolt throw: mm (deadbolt), 10 mm (double action bolt) Backset: 55, 60, 65, 0, 100 mm (EL560, EL561) 30, 35, 40, 45 mm (EL460, EL461) Forend:, 24 mm (EL560, EL561) 24, 2 mm (EL460, EL461) Spindle: 9 mm ( mm with spindle adapters) Settable functions: Mechanical functions: - Handing of trigger bolt - Electrically controlled side (EL560, EL460) Electrical function: - Fail locked / Fail unlocked Monitoring outputs: Bolt deadlocked Bolt inside the lock case Trigger bolt in Handle used Cylinder used Cable sabotage CONTROL PRINCIPLE AND AVAILABLE MONITORING OUTPUTS DOOR ENVIRONMENT Wooden and metal doors Door closer Leave some extra cable on both sides of the lead cover Ø 10 mm drilling for cable Narrow profile doors Door closer Ø mm pipes to lead cable inside the wall + 12V DC (-10%) - 24V DC (+15%) STAB. *)**) LOCKED / OPEN *)**) (POTENTIAL FREE CONTROL) CYLINDER USE HANDLE DOWN COMMON FOR HANDLE DOWN / CYLINDER USE BOLT OUT COMMON FOR BOLT OUT TRIGGER BOLT IN BOLT IN COMMON FOR BOLT IN / TRIGGER BOLT IN SABOTAGE LOOP MONITORING OUTPUTS **) Ø 15 mm pipe to lead cable inside the profile CAM ANGLE Leave some extra cable on both sides of the lead cover Ø mm pipes to lead cable inside the wall *) Not microswitch or mechanical locks **) Not mechanical locks Max 7 Max 45 Max 45 CYLINDERS, FITTINGS AND ACCESSORIES (Please order separately) Single Double Single with thumbturn NOVEL CY321U CY331U CY322U CY332U CY323U CY333U EUROPROFILE DIN CYLINDER PROTEC CY321N CY331N CY322N CY332N CY323N CY333N DISKLOCK PRO CY321D CY322D CY323D FITTINGS *) IKON Ruko BEZAULT others SPLIT SPINDLES EA2 (mm) EA29 (9mm) CABLES EA21 (6m) EA219 (10m) LEAD COVERS EA EA21 STRIKE PLATES EA321**) EA322 EA323**) EA324 EA325 EA326 EA327 EA32 EA329 EA330 EA331 EA332**) *) For further information, please contact Abloy Oy Architectural Hardware. **) Handing must be defined.

STRIKE PLATES EA321**) EA322 EA323**) EA324 EA325 EA323 152 170 232 250 EA321 2 2 25,1 EA326 EA327 EA32 EA329 EA330 EA331 EA332**) **) Handing must be defined

22 DIMENSIONS EL460, EL461 45 / 50 / 55 / 60 30 / 35 / 40 / 45.5 10.5 101 10 10.5 5.5 91 76 300 35 12 6 39 22 / 9.5 5.5 25 25 21.5 92(PZ) / 94 (RZ) 254 22 17 EL560, EL561 3 4.5 x 2 15 32 30 / 93 / 9 / 113 / 133 55 / 60 / 65 / 0 / 100 16.5 24 / 2 10 R7 / 9 66.5 3 235 6 21.5 72(PZ) / 74 (RZ) 16.5 35 6 x 2 / 24 3 3 6 x 2 35 57 63 35 15

EMERGENCY EXIT DEVICES ACCORDING TO EN 179 The following locks and handles are approved to be installed together in an emergency exit door to conform EN 179. Profile door locks EL460 EL260 EL060 Wooden and metal door locks EL560 EL360 EL160 DO.33.01 DO.33.02 e.g. INOXI 3-19/013 PZ+BL INOXI 3-19/013/1 PZ+BL DO.33.01 DO.33.02 e.g. INOXI 3-19/012 PZ+BL INOXI 3-19/012/1 PZ+BL IKON DO.15.02 e.g. S6B3, S6B6 e.g. S6B IKON DO.15.02 e.g. S326, S426, S4K3 e.g. S4K6 FSB DO.03.01, DO.03.02 1016, 1023, 1056, 1070, 100, 10, 1090, 1117, 111, 1119, 1137, 1146, 1155, 1160, 1161, 1162, 1177, 117, 1191, 0612, 0616, 0617, 0619, 0625, 0627, 062, 0646, 0662, 0665, 060, 061, 062, 06 HEWI DO.13.01, DO.13.02 111, 111.23, 114.23GK, 131, 132, 111X, 113X, 114X, 161X, 163X, 171X, 112X, 165X, 166X SAPEX DO.32.01 DO.32.02 e.g. 60-0019 SAPEX DO.32.01 DO.32.02 e.g. 60-0419, 60-0319 The safety features of this product are essential to its compliance with EN 179. No modification of any kind, other than those described in the installation manual, are permitted. PANIC EXIT DEVICES INSTALLATION ACCORDING TO EN 1125 The following locks and push bars are approved to be installed together in an panic exit door to conform EN 1125. The push bars can be installed for example with above mentioned outside fittings (Table EN 179) to conform EN 1125. Profile door locks effeff DO 30.04 JPM DO 30.05 TESA DO 30.06 HEWI DO 30.10 EL460, EL260, EL060 EL462, EL262, EL062 Wooden and metal door locks EL560, EL360, EL160 EL562, EL362, EL162 000-00-1100 (-), 000-10-1100 (PZ) 000-00-1100 (-), 000-11-1100 (RZ) effeff DO 30.04 000-00-1100 (-), 000--1100 (PZ) 000-00-1100 (-), 000-21-1100 (RZ) NORMA 990000-XX-0A 990100-XX-0A 990001-XX-0A 990101-XX-0A 991000-XX-0A 991100-XX-0A 991001-XX-0A 991101-XX-0A TESA DO 30.06 UNIVERSAL SERIE 19709G9xx HEWI PS 160XA 40 0 The safety features of this product are essential to its compliance with EN 1125. No modification of any kind, other than those described in the installation manual, are permitted. EN179 and EN1125 standards are comformed, when the above mentioned lock is installed with strike plates listed in this brochure. This document may not be used in the installation of a lock. Drilling and wiring diagrams and installation instructions are included in the installation manual, which is included in each lock case package. We reserve the right to make alterations to the products described in this leaflet. www.abloy.com Abloy Oy Wahlforssinkatu P.O.Box 10 FI-0101 JOENSUU FINLAND Tel. +35 599 2501 Fax +35 599 29 01046 2/11 00 kpl Suomen Painotuote, Joensuu An ASSA Group brand Abloy Oy is one of the leading manufacturers of locks, locking systems and architectural hardware and the world s leading developer of products in the field of electromechanical locking technology. ASSA is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.