RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters



Similar documents
RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

PHOENIX CONTACT Features

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic overload relay EF19 and EF45

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electronic overload relay EF65, EF96 and EF146

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

38 Series - Relay interface modules A

Digital input modules

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

80 Series - Modular timers 16 A. Features

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Safety technique. Emergency stop module BO 5988 safemaster

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Analog signal converters CC-E I/I Current / current isolators

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SINEAX U553 Transducer for AC Voltage

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Preset Counter signo 721

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

49 Series - Relay interface modules A. Features

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Thermistor motor protection

Relés e Contatores de Estado Sólido SIRIUS

13 SERIES. Electronic step relays A

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Redundancy Module QUINT-DIODE/40

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SURGE PROTECTIVE DEVICES

EMR measuring and monitoring relays

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Type: DILM9 10(24VDC) Article No.:

R.C.C.B. s two-pole LEXIC

MasterINTERFACE 39 Series - Relay interface modules

Power Supplies 3. SDN-P DIN Rail Series

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

80 Series - Modular timers 16 A. Features

DS 600. A contact free flux gate based current measurement sensor 600A rms

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MasterINTERFACE 39 Series - Relay interface modules

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Type: DILM32 10(24V50HZ) Article No.:

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

E-STOP relays, safety gate monitors

Pluggable interface relays CR-P Pcb relays

Quick Connect. quick - simple - efficient.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

RY2 miniature industrial relays

E-STOP relays, safety gate monitors

7 - Phaseo power supplies and transformers

CompactLogix Power Supplies Specifications

Thermal-Magnetic Circuit Breaker M1-..

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

CQM1-SF200/CS1W-SF200

PNOZsigma - Base units

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ABB i-bus KNX SA/S Switch Actuators Product Manual

E-STOP relays, safety gate monitors

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Contact expansion modules

E-STOP relays, safety gate monitors

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Energy Management Energy Meter Type EM23 DIN

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Bimetallic Overload Relay Specifications

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Transcription:

Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Switching capacity in VA Minimum switching current Maximum switching current Power consumption in VA Measurement range Electrical connection Zelio Control Modular measurement and control relays Multifunction voltage control relay RM35UA Overvoltage or undervoltage detection Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold 1250 VA 10 ma at 5 V DC 5 A AC/DC <= 3.5 VA AC 15...600 V voltage 1 conductor cable 0.2...2.5 mm² AWG24...AWG12 flexible cablewith cable end conforming to IEC 1 conductor cable 0.5...4 mm² AWG20...AWG11 solid cablewithout cable end conforming to IEC 2 conductors cable 0.2...1.5 mm² AWG24...AWG16 flexible cablewith cable end conforming to IEC 2 conductors cable 0.5...2.5 mm² AWG20...AWG14 solid cablewithout cable end conforming to IEC Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 1500 ms for time delay 250 V AC/DC 24...240 V AC/DC 20.4...264 V AC/DC <= 0.6 W DC Control circuit frequency 40...70 Hz +/- 10 % Resistance across terminals Output contacts Nominal output current Measuring cycle Hysteresis Delay at power up Measurement accuracy 150 mohm E1-M terminals 300 mohm E2-M terminals 600 mohm E3-M terminals 2 C/O 5 A <= 30 ms measurement cycle as true rms value 5...50 % of threshold setting 0.6 s +/- 10 % of the full scale value The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 7/9/2011 1

Repeat accuracy Measurement error Polarity Sensitivity scale Threshold setting 10...100 % Marking +/- 0.5 % for input and measurement circuit +/- 2 % for time delay +/- 0.05 %/ C with temperature variation < 1 % over the whole range with voltage variation Non reversible polarity on DC supply 15...150 V E1-M terminals 30...300 V E2-M terminals 60...600 V E3-M terminals CE : 73/23/EEC CE : EMC 89/336/EEC Overvoltage category III conforming to IEC 60664-1 Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 [Ui] rated insulation voltage 250 V conforming to IEC 60664-1 600 V conforming to IEC 60664-1 Operating voltage tolerance - 15 % + 10 % Un Supply frequency 50/60 Hz +/- 10 % Insulation Operating position Between supply and measurement Any position without derating Tightening torque 0.6...1 N.m conforming to IEC Housing material Status LED Self-extinguishing plastic 1 LED green for power ON 1 LED yellow for relay ON Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability Mechanical durability Operating rate Width Product weight 100000 cycles 30000000 cycles <= 360 operations/hour under full load 35 mm 0.08 kg Environment Immunity to microbreaks 10 ms Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 Standards EN/IEC 60255-6 Product certifications CSA C-Tick GL GOST UL Ambient air temperature for storage -40...70 C Ambient air temperature for operation -20...50 C Relative humidity 95 % at 55 C conforming to IEC 60068-2-30 Vibration resistance 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f = 57.6...150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 Shock resistance 5 gn conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2 kv AC 50 Hz, 1 min conforming to IEC 60255-5 2 kv AC 50 Hz, 1 min conforming to IEC 60664-1 Non-dissipating shock wave 4 kv conforming to IEC 60255-5 4 kv conforming to IEC 60664-1 4 kv conforming to IEC 61000-4-5 RoHS EUR status Compliant RoHS EUR conformity date 0701 2

Dimensions Drawings Multifunction Voltage Control Relays Dimensions and Mounting 3

Connections and Schema Multifunction Voltage Control Relays Wiring Diagram 4

Technical Description Function Diagrams Undervoltage Control Without memory ("No Memory" mode) U< Undervoltage threshold (set by means of a potentiometer graduated as a percentage of the scale value of Un) With memory ("Memory" mode) U< Undervoltage threshold (set by means of a potentiometer graduated as a percentage of the scale value of Un) In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product. Overvoltage Control Without memory ("No Memory" mode) U> Overvoltage threshold (set by means of a potentiometer graduated as a percentage of the scale value of Un) 5

With memory ("Memory" mode) U> Overvoltage threshold (set by means of a potentiometer graduated as a percentage of the scale value of Un) In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product. 6