BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch



Similar documents
BNI IOL K006 BNI IOL K006. IO-Link Sensor-Hub analog User s Guide

BNI EIP Z015 IP67 Modules 4 IO Link/In-/Outputs,12 In-/Outputs User s Guide

HARTING econ 3000 Introduction and features

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Modular I/O System Analog and Digital Interface Modules

HARTING mcon 1000 Introduction and features

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

HARTING Ethernet Cabling 4-poles Overview

PCS0100en Persy Control Services B.V. Netherlands

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

AXIS T81B22 DC 30W Midspan

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Instruction Manual Differential Pressure Transmitter

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

HARTING Ethernet Cabling 4-poles Overview

ABSOLUTE ROTARY ENCODER ETHERNET/IP

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

HARTING mcon 3000 Introduction and features

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Hardware Manual RM CANview Ethernet

Perle 10/100 Ethernet Media Converters

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Rack mounted telephone- and leased line modem for industrial applications

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

HARTING econ 4000 Introduction and features

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Ha-VIS FTS 3000 Introduction and features

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Original instructions Tina 3A/Aps Adaptor unit

Accessories SUNNY REMOTE CONTROL

Telephone- and leased line modem for industrial applications TD-36

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Moxa EtherDevice Switch

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

My first Hirschmann: The SPIDER family of switches.

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

R60 USB to CAN interface Manual (1.5 EN)

HARTING Ethernet Cabling 8-poles Overview

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.2 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

USB-to-CAN V2 compact

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

INSTALLATION INSTRUCTIONS

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Perle 10/100/1000 Ethernet Media Converter Module

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

GREISINGER electronic GmbH

Antenna Splitter ASA 1. Instruction manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

KNX R. Rain Sensor. Installation and Adjustment

CONFIGURABLE SAFETY RELAYS

HMI display Installation Guide

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

9000 Series Accelerometers Specifications

GAE953 Electrical Alarm Unit 19" with Indicator

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Tina 2A/B Adaptor unit

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

IMVIB. Online vibration monitoring for Ariel compressors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Grid Automation Products. SAM600 Process Bus I/O System Cyber Security Deployment Guideline

aseries A13B Mini Bullet Camera User Manual

MINI MCR-SL-R-UI(-SP)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Manual Serial PCI Cards

LMR16TC Mini 10BASE-T Repeater. Installation Guide

General 1-2-Opto-electronics Safety Switches 4-Emergency

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

USB Rover port USB m Cat 5 Extender. User Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical Data. Dimensions

Digital display DA 48

Digital input modules

Addendum to the Operating Instructions

CONFIGURABLE SAFETY RELAYS

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Transcription:

BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch

Balluff Ethernet IP, BNI EIP-104-100-Z016 1 Notes to the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typgraphical Conventions 2 1.4 Symbols 2 1.5 Abbreviations 2 2 Safety 2.1 Intended Use 3 2.2 General Safeety Notes 3 2.3 Meaning of the warnings 3 3 Getting Started 3.1 Connection overview 4 3.2 Mechanical connection 5 3.3 Electrical connection 5 3.4 Ethernet connection 5 3.5 Connecting sensors 5 4 Technical Data 4.1 Dimensions 6 4.2 Mechanical Data 6 4.3 Operating conditions 6 4.4 Electrical Data 6 4.5 Ethernet Port 7 4.6 Function Indicators 7 5 Included Material 5.1 Included Material 17 6 Appendix Ordering code 18 Bit Layout 18

1 Notes to the User 1.1 About this guide This guide describes the Balluff Ethernet IP Fieldbus Module BNI EIP-, which enables expanded communication down to the lowest level so as to provide improved process optimizing and preventive maintenance. This module is IP67 protected and features a rugged metal IP67 housing. The device is ideal for use in harsh industrial environments. 1.2 Structure of the guide 1.3 Typographical Conventions Syntax Cross-references The Guide is organized so that the sections build on one another. Section 2. Basic safety informations. Section 3: The main steps for installing the device. Section 4: Technical data for the device. The following typographical conventions are used in this Guide. Numbers Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex). Cross-references indicate where further information on the topic can be found ("see Section 4.2 ). 1.4 Symbols Note, tip This symbol indicates general notes. 1.5 Abbreviations BNI Balluff Network Interface EIP Ethernet IP EMC Electromagnetic Compatibility FE Function Ground Attention! This symbol in connection with the word "Attention" warns of a possible hazardous situation for the health of persons or for equipment damage. Disregard of these warning notes may result in injury or damage to equipment. Always observe the described measures for preventing this danger. www.balluff.com 2

2 Safety 2.1 Intended Use The BNI EIP- serves as a unmanaged switch module for connecting to a Ethernet IP network. 2.2 General Safety Notes Installation and startup Installation and startup are to be performed only by trained personnel. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The device is an equipment in accordance with EMC Class A. Such equipment may generate RF noise. The operator is responsible for taking the appropriate measures before using. The device may be operated only using an approved power supply (see 4 Technical Data ). Only approved cables may be used. 2.3 Meaning of the warnings Operation and testing The operator is responsible for ensuring that local prevailing safety regulations are followed. When defects and non-clearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use is ensured only when the housing is fully installed. Caution! This symbol in connection with the word "Caution" warns of a possible hazardous situation for the health of persons or for equipment damage. Disregard of these warning notes may result in injury or damage to equipment. Always observe the described measures for preventing this danger. www.balluff.com 3

3 Getting Started 3.1 Connection Overview 1 13 12 2 3 11 4 10 5 9 6 8 7 1 Connection overview BNI EIP-950-000-Z009 1 Mounting hole 2 Port label 3 Status LED 4 Ethernet IP Port 5 5 Ethernet IP Port 6 6 Ethernet IP Port 7 7 Ethernet IP Port 8 8 Ethernet IP Port 4 9 Ethernet IP Port 3 10 Ethernet IP Port 2 11 Ethernet IP Port 1 12 Power supply 13 Ethernet IP Uplink Port www.balluff.com 4

3 Getting Started 3.2 Mechanical connection 3.3 Electrical connection Supply voltage The module is attached using 2 M6 screws and 2 washers. Isolation pad as accessory available Power (7/8 Mini 4-pin plug) PIN Signal Demand 1 +24 V Output Power 2 +24 V Input Power (not used for the 8 O modules) 3 0 V Input Power Common 4 0 V Output Power Common 24 V DC. Total current <9A. The total current of all modules may not exceed 9A even when daisy chaining the actuator supply. Function ground Note! The FE connection from the housing to the machine must be low-impedance and kept as short as possible. 3.4 Ethernet Connection The Ethernet connection is made using the M12 females (D-coded). Ethernet Port: (M12, D-coded, female) PIN Requirement 1 Tx+ 2 Rx+ 3 Tx- 4 Rx- www.balluff.com 5

4 Technical Data 4.1 Dimensions 4.2 Mechanical Data Housing material Die-case zinc, matte nickel plated Enclosure rating per IEC 60529 IP 67 (only when plugged-in and threaded-in) Supply voltage 7/8 4-pin male Dimensions (W x H x D in mm) 68 x 224 x 30.9 Mounting type 2-hole screw mount Ground strap attachment M4 Weight Approx. 580gr. 4.3 Operating conditions Operating temperature T a Storage temperature EMC - EN 61000-4-2/3/4/5/6 - EN 55011-5 C... 55 C -25 C... 75 C - Severity level 4A/3A/4B/2A/3A - Gr.1, CL. A Shock/vibration EN 60068-2-6, EN 60068-2-27 EN 60068-2-29, EN 60068-2-64 4.4 Electrical Data Supply voltage 18...30.2 V DC, per EN 61131-2 Ripple <1% Input current at 24 V 130 ma www.balluff.com 6

4 Technical Data 4.5 Ethernet Port Ethernet IP Uplink port 1 x 10Base-/100Base-Tx Connection for Ethernet IP Uplink port Standard Ethernet IP ports Connection for standard Ethernet ports Cable types per IEEE 802.3 Data transmission rate Max. cable length Flow control M12, D-coded 8 x 10Base-/100Base-Tx M12, D-coded Shielded twisted pair, min. STP CAT 5/ STP CAT 5e 10/100 Mps 100 m Half Duplex/Full Duplex (IEEE 802.33x- Pause) 4.6 Function Indicators LED indicators Ethernet IP / module LED 1-9: Indication: Module / Uplink port Port LED: Link Port LED: Data transmission rate LED Indicator Function LED 1 Green/Red Power Status LED 4 Red/Off Module Status LED 7 Yellow/Off Data transfer Uplink port active/inactive LED 9 Yellow/Off Data trans. Rate Uplink port: 100Mbit/s / 50 Mbit/s LED indicators ports Each M12 Port is assigned two 2-color LEDs which indicate the configuration or operating states. LED LNK Off Yellow Green blinking LED 100 Yellow/Off Function LED Ethernet link is inactive Ethernet link is active Data transfer is active Data trans. Rate: 100 Mibit/s / 50 Mbit/s www.balluff.com 7

5 Included Material 5.1 Included Material The BNI EIP consists of the following components: IO-block 4 blind plugs M12 Ground strap Screw M4x6 20 labels www.balluff.com 8

6 Appendix Ordering code BNI EIP-950-000-Z009 Balluff Network Interface IO-Link interface Functions 950 = IP 67 module, unmanaged switch Variant 000 = Standard version Mechanical version Z009 = Die-cast zinc housing Material: 1. Balluff housing version Uplink: 1 x M12x1 internal thread Power: 7/8 external thread Ethernet Ports: 8 x M12x1 internal thread www.balluff.com 9

www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de ν www.balluff.com www.balluff.com 10