A99B Series Temperature Sensors



Similar documents
System 350 A350E Electronic Cooling Control

System 350 A350R Electronic Temperature Reset Control (with Relay)

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

System 350 A350A/B Electronic Temperature Control

G670 Intermittent Pilot Ignition Controls

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

P66 Series Electronic Fan Speed Controls

V47 Series Temperature Actuated Modulating Water Valves

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

T7079A,B Solid State Remote Temperature Controllers

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

CST29A Adapter Block for Carlyle Compressors

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

P70, P72, and P170 Series Controls for Dual Pressure Applications

MP8000 Series Pneumatic Valve Actuators

Part I - Installation

Advantium 2 Plus Alarm

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Toroidal Conductivity Sensor

TE-6300P Series Temperature Sensors

MCR1900 Media Converter 19-Slot Chassis

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Commercial Refrigeration Temperature and Defrost Controls

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

LIEBERT VNSA Installation Sheet

RAY-MAX Integrated Solar Power Strip

Submersion/Insertion Toroidal Sensor

! WARNING. Before using product, read and understand instructions.

Low Frequency Velocity Sensor

HP UPS R1500 Generation 3

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

SECTION MORTUARY REFRIGERATORS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

5800 Temperature Sensor Cable Assembly

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Ducoterra Radiant Heating Panel Installation Manual

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Duct Temperature Sensors

Series 510 Submersible Level Transmitters

Duct Humidity Transmitter

Radiant Temperature Sensor TY7321

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

PART 1 - INTRODUCTION...

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Pipe Temperature Sensors

TR21, TR22, TR23, and TR24 Wall Modules

ATL Fuel Level Sender Probes

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

RayClic Connection System Installation Instructions

FX07 Field Controller

Powers Controls TH 192 S Single Temperature Room Thermostat

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Tubing and Accessories

RayClic Connection System Installation Instructions

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

The Do s and Don ts of Pressure Transducers

GenStore Archive Cabinet

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Digital inductive conductivity transmitter

VG2000 Series Cast Iron Flanged Globe Valves

Thermistor Thermometer MODEL NO

T-4000 Series Pneumatic Room Thermostats

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

UV100A Ultraviolet Air Treatment System

16/32 Channel 1U Rack Mount CCTV Power Supply

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

QT Residential Blower Metal Residential Blower

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Power Supply Cables and Connectors

Single Station Remote Alarm

E-PDD Duct Smoke Detector Installation Sheet

V46 Pressure-Actuated Water-Regulating Valve

400 Series - Mini USB Buccaneer

Sanitary Type Electronic Flow Switches

Cooling system components, removing and installing

Complete System Shelter

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

About the BitStorm 6051 POTS Splitter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Transcription:

FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors are splashproof and are designed to measure temperature in a variety of refrigeration applications. Several accessories allow easy tailoring of the temperature sensor to various mounting configurations. Applications include temperature sensing for freezers and coolers, as well as in defrost termination sensing, space and return air temperature sensing, and condenser fan cycling. Figure 1: A99B Temperature s Features and Benefits Variety of Lead Lengths Assortment of Mounting Hardware Available Very Accurate Sensing Element Stainless Steel Bulb Encompasses most application requirements and simplifies wiring sensors Provides configuration for many applications customizable Provides excellent performance in a wide variety of control applications Allows use in more applications than other types of bulbs; no corrosion 2015 Johnson Controls, Inc. 1 Part No. 24-7664-1636, Rev. A www.johnsoncontrols.com Code No. LIT-125186

Application Overview IMPORTANT: All A99B Series s are designed for use only with operating controls. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory) that protect against, or warn of, control failure. The A99B temperature sensor line offers an economical solution for a wide variety of temperature sensing needs in refrigeration and HVAC applications. Typical temperature sensing applications and environments include: freezers display cases walk-in coolers reach-in coolers defrost termination temperature sensing condenser fan cycling space and return air temperature sensing outdoor air sensing process cooling and heating Temperature Averaging Multiple sensors may be wired in a series parallel arrangement to provide an average temperature reading in an area when one sensor cannot provide a representative temperature reading. This can be accomplished with 4, 9, 16, etc., (2 2, 3 2, 4 2, etc.) sensors. In a series parallel arrangement, there must always be the same number of parallel-connected sensors as there are series connected sensors. In Figures 2-4, each parallel leg is represented as a column of sensors and each series leg as a row of sensors. To Controller Figure 2: 4- Averaging Wiring To Controller Figure 3: 9- Averaging Wiring To Controller Figure 4: 16- Averaging Wiring 2 A99B Series Temperature s Product/Technical Bulletin

D imensions 1/4 (6) Accessories 2 (50) Figure 5: A99B, in. (mm) A99B series accessories include the following: 9 1/8 (229) 1 3/4 (44) 1 11/16 (42) 1 3/8 (35) O peration The A99B sensor incorporates a PTC silicon sensing element whose resistance increases with an increase in temperature. The sensor has a reference resistance of 1,035 ohms at 77F (25C). Each element is calibrated according to a standard graph, as shown in Table 2. The A99B series sensors are typically used with Johnson Controls/PENN System 450 controls, MR Defrost controls, MS Multi-Stage controls, and A421 Electronic Temperature Controls. The A99B sensors can also be used with Johnson Controls System 27 NOVA; A255 fan speed control modules; and R78, DX-9100, XP-9102, XPA-4x1, System 350 controls, A419 Electronic Temperature controls, and XPA-8x1 products. 1/4 (6) 4 5/16 (110) 1/2 (13) Sun Shield SHL10A-603R EMT Conduit Adapter ADP11A-600R 1 (25.4) 1 (25.4) Surface Mount Clip A99-CLP-1 4 3/4 (119) 7/8 (23) 4 1/2 (113.5) PVC Enclosure BOX10A-600R 3 (76) Dia. 3/8 (9.3) Figure 6: Available Accessories, in. (mm) M ounting Mounting Considerations The A99B sensor may be mounted in virtually any position. To ensure proper operation of the A99B Series sensors, observe the following guidelines: Mount sensors in areas where they are exposed to representative temperature conditions and sufficient air mixing. Avoid mounting the sensors where air stratification exists. Avoid areas subject to excessive mechanical vibration or electrical noise. For outdoor applications, avoid areas where the sensor will be exposed to direct sunlight because this causes the sensor to read a higher temperature. The north side of the building is preferred for outdoor sensors. If not possible, install a sun shield. Use a thermally conductive paste where appropriate to improve the thermal contact with the sensor. Do not subject silicon cable (A99BC) to any silicon-based fluids, as this will degrade the cable. A99B Series Temperature s Product/Technical Bulletin 3

Mounting Using an Immersion Well 1. Select the mounting location in the pipe line. A 1/2 in., 14 NPT, opening is required to properly install the immersion well (WEL11A- 601R). The pipe s diameter must be greater than the length of the well probe. 2. Insert an appropriate amount of thermally conductive paste in the well. 3. Install the immersion well. Tighten hex nut securely using a wrench. Tighten with Wrench Mounting with a PVC Enclosure The PVC enclosure can be mounted in a variety of ways. See Figure 6 for mounting dimensions. When mounting the PVC enclosure, refer to the Mounting Considerations section, as well as the following: To minimize false readings caused by air movement through the conduit hole, seal that part of the enclosure after the sensor has been inserted. If a conduit connection is required, snap the conduit adapter into the bottom opening of the enclosure and tighten the adapter s set screw. 1. Loosen the two PVC enclosure screws and remove the front plate. 1/2 inch 14 NPT Opening Figure 7: Installing the Immersion Well Clip Front Plate PVC Enclosure Screws 4. Using a straight slot screwdriver, loosen the set screw at top of the immersion well. 5. Thread the spring, then the bushing, onto the sensor lead. Figure 9: PVC Enclosure 2. Thread the sensor through the bottom opening and snap the sensor in the sensor clip inside the PVC enclosure. 3. Replace the front plate on the PVC enclosure and firmly tighten the screws. Figure 8: Insert, Spring, and Bushing 6. Insert sensor, spring, and bushing into well, so that at least one-half of the bushing is inserted into the well, as shown in Figure 8 (bushing will compress spring). 7. Tighten the set screw against the bushing. 4 A99B Series Temperature s Product/Technical Bulletin

W iring! WARNING: Shock Hazard. Disconnect all power to the controller that the sensor is connected to before wiring or servicing. For wiring, follow the instructions below: Make sure all wiring conforms to the National Electric Code and local regulations. Run high and low voltage wiring in separate conduits. For applications in critical industrial environments, use a sensor with a shielded cable (A99BA). If wire is added to the sensor leads, additional resistance may affect the sensor reading. Longer wires increase resistance, which causes a shift in the sensor temperature reading. Note: At the wire lengths listed in Table 1, the error in the sensed temperature is less than 1F (0.5C). Table 1: Maximum Wire Lengths (for less than 1 F error) Wire Gauge Wire Length AWG Feet Meters 14 AWG 800 244 16 AWG) 500 152 18 AWG 310 94 20 AWG 200 61 22 AWG 124 38 Checkout Procedure Before applying power, make sure installation and wiring connections are according to job specifications. After necessary adjustments and electrical connections have been made, operate the system and observe at least three complete cycles before leaving the installation. T roubleshooting Check the sensor for proper resistance: 1. Disconnect the sensor from the control. 2. Take a temperature reading at the sensor location. Be sure to let the thermometer stabilize before taking a reading. 3. Use the temperature reading from Step 2 to determine the expected sensor resistance from Table 2. 4. Using an ohmmeter, measure the actual resistance across the two sensor leads. 5. Compare the expected resistance to the actual resistance. 6. If the sensor's actual resistance deviates substantially from the expected resistance found in Table 2, replace the sensor. Shielded Cable Models (A99BA) Only: For all controls, including the Johnson Controls/PENN System 350, MR, MS, and A419, connect the sensor cable shield to the controller per the controller s instructions. A99B Series Temperature s Product/Technical Bulletin 5

Temperature ( F) Temperature ( C) 260 240 220 200 180 160 140 120 100 80 60 40 20 0-20 -40 500 700 900 1100 1300 1500 1700 1900 2100 120 100 80 60 40 20 0-20 Resistance in Ohms Figure 10: Resistance Scale for Fahrenheit Temperatures -40 500 700 900 1100 1300 1500 1700 1900 2100 Resistance in Ohms Figure 11: Resistance Scale for Celsius Temperatures Table 2: Resistance vs. Temperature F ( C) Resistance in Ohms F ( C) Resistance in Ohms -40 (-40) 613 113 (45) 1195-31 (-35) 640 122 (50) 1237-22 (-30) 668 131 (55) 1279-13 (-25) 697 140 (60) 1323-4 (-20) 727 149 (65) 1368 5 (-15) 758 158 (70) 1413 14 (-10) 789 167 (75) 1459 23 (-5) 822 176 (80) 1506 32 (0) 855 185 (85) 1554 41 (5) 889 194 (90) 1602 50 (10) 924 203 (95) 1652 59 (15) 960 212 (100) 1702 68 (20) 997 221 (105) 1753 77 (25) 1035 230 (110) 1804 86 (30) 1074 239 (115) 1856 95 (35) 1113 248 (120) 1908 104 (40) 1153 accuracy is within 0.9F (0.5C ) between 5 and 167 F (-15 and 75 C). Tolerance increases at temperatures outside this range, as shown in Figure 12. Error from Nominal F (C ) 2.7 (1.50) 1.8 (1.00) 0.9 (0.50) 0.00-0.9 (-0.50) -1.8 (-1.00) -2.7 (-1.50) -40 (-40) -4 (-20) 32 (0) 68 (20) 104 (40) 140 (60) 176 (80) 212 248 (100) (120) Temperature F ( C) Figure 12: Accuracy 6 A99B Series Temperature s Product/Technical Bulletin

Repairs and Replacement Field repairs or calibration must not be made. For replacement sensors, contact your nearest Johnson Controls/PENN representative. When contacting the supplier, state the model number of the sensor. The sensor model is printed on the yellow label wrapped around the sensor cable. Ordering Information Table 3: s Product Code Number A99BA-200C A99BB-25C A99BB-200C A99BB-200D A99BB-300C A99BB-500C A99BB-600C A99BC-25C A99BC-300C A99BC-1500C Description PTC Silicon with Shielded Cable; Cable length 6-1/2 ft (2 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable; Cable length 9-3/4 in. (0.25 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable; Cable length 6-1/2 ft (2 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable Bulk Pack; contains 100 A99BB-200 sensors. Individual sensor cable length 6-1/2 ft (2 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable; Cable length 9-3/4 ft (3 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable; Cable length 16-3/8 ft (5 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with PVC Cable; Cable length 19-1/2 ft (6 m); Range: -40 to 212 F (-40 to 100 C) PTC Silicon with High Temperature Silicon Cable Cable length 9-3/4 in. (0.25 m); Range: -40 to 248 F (-40 to 120 C) PTC Silicon with High Temperature Silicon Cable Cable length 9-3/4 ft (3 m); Range: -40 to 248 F (-40 to 120 C) PTC Silicon with High Temperature Silicon Cable Cable length 49 ft (15 m); Range: -40 to 248 F (-40 to 120 C) Table 4: Accessories (See Figure 6 for illustration of accessories.) Product Code Number A99-CLP-1 ADP11A-600R BOX10A-600R SHL10A-603R WEL11A-601R Description Surface Mounting Clip for the A99B Temperature 1/2 in. diameter EMT Conduit Adapter (box of 10) for use with BOX10A-600R PVC Enclosure Sun Shield Immersion Well A99B Series Temperature s Product/Technical Bulletin 7

S pecifications Product Sensing Range Reference Resistance Accuracy Construction Lead Wire Insulation Lead Wire Gauge Ambient Operating Conditions Ambient Storage Conditions Shipping Weight A99B Series Silicon Temperature s Model A99BA and A99BB: -40 to 212F (-40 to 100C) Model A99BC: -40 to 248F (-40 to 120C) 1,035 ohms at 77F (25C) 0.9 F (0.5 C) between 5 and 167 F (-15 and 75 C). See Figure 12 for accuracy outside of this range. Probe: Stainless Steel Model A99BA: Model A99BB: Model A99BC: 22 AWG Accessories See Table 4. Shielded PVC Cable PVC Cable High Temperature Silicon Cable Model A99BA and A99BB: -40 to 212 F (-40 to 100 C); 0 to 100% RH, Condensing Model A99BC: -40 to 248 F (-40 to 120 C); 0 to 100% RH, Condensing Model A99BA and A99BB: -40 to 221 F (-40 to 105 C); 0 to 100% RH, Condensing Model A99BC: -40 to 266 F (-40 to 130 C); 0 to 100% RH, Condensing 1.4 oz (41 g) for 6 1/2 ft (2 m) sensor The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls/Penn Application Engineering at (414) 274-5535. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 www.johnsoncontrols.com Printed in U.S.A. 8 A99B Series Temperature s Product/Technical Bulletin