Controllers Model 353 Process Automation Controller with Ethernet Communication (Design Level B) Introduction



Similar documents
Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

40.3. Control Relays and Timers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Application/Connection Examples

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Programming Logic controllers

Regards from the Team at Rheology Solutions.

Disturbance Recoder SPCR 8C27. Product Guide

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Temperature & Humidity SMS Alert Controller

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Programmable Controller G Series. New. Models

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

NEW. EVEN MORE data acquisition and test stand automation

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

NC-12 Modbus Application

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

PIEZOMETER AIRFLOW MEASURING RING

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power


LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Safety technique. Emergency stop module BO 5988 safemaster

Unidirectional Transmitter/ Receiver Units Introduction

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation manual. Generator Paralleling Controller GPC multi-line C

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

PCS0100en Persy Control Services B.V. Netherlands

Optimize your simple machines... Modicon M218 Selection Guide

Simplify Data Acquisition with a Built-in LXI Web Server

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Voltage Regulator SPAU 341 C. Product Guide

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Generator Differential Relay Electrical Apparatus

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

EnerVista TM Viewpoint Monitoring v7.10

How to read this guide

Thyristor-controlled power supplies and battery chargers

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TC-9102 Series Surface Mount Temperature Controllers

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

HI/ICMI UVR-1 Universal Voltage Regulator Control

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Everything you need for protection scheme testing

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Table of Contents. TransformerIQ FAQs 1

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

SL Series AC and DC Electronic Loads

V350-TA24 V350J-TA24.

Web-Based Remote Monitoring & Datalogging

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Remote Sources. Facility. Router

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Short information Parameters are programmed via front-side membrane keypad

Programmable Logic Controller PLC

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Features, Benefits, and Operation

LOXONE 12 Channel Amplifier

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

OZW30. Central Unit SYNERGYR

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Electronic Flow Switches

Electronic Control Devices The European Product Catalogue 2007

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

PowerLogic Sub Meter Display (SMD and SMDOPN)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Sanitary Type Electronic Flow Switches

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Programming A PLC. Standard Instructions

Multi-Range Programmable DC Power Supplies 9115 Series

T Zone Weekly Timer

Controller Automation, Model II+

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

In-Sight Hardware specifications

Modular I/O System Analog and Digital Interface Modules

Polyphase kwh Electricity Meter

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

1.44 kw Programmable DC Power Supplies XLN Series

iologik E1200 Series User s Manual

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Transcription:

Introduction Features & Benefits Affords easy integration with and migration to existing systems Multiple loop capabilities for indication, control, logic, or sequencing accommodate comprehensive process control needs Scalable hardware provides lower entry costs, without limiting future needs Full configuration capability via front faceplate push-buttons allows quick field changes without requiring additional tools Ethernet communication is standard, providing peer-to-peer communications. RS485 MODBUS network connection allows multi-drop wiring for operation, monitoring, troubleshooting, or configuration from a system workstation Front panel PC connection accommodates local configuration, monitoring, or troubleshooting using the graphical configuration software Real Time Clock provides status ouput based on time of day. Removeable configuration media stores a complete backup copy of the control strategy configuration Factory Configured Options (FCOs) facilitate fast configuration for common applications Password protection provides individual security for various plant personnel Graphical configuration program provides a choice of function block or ladder logic configuration Short case design allows mounting in 1" deep cabinets Coated circuit boards ensure reliable operation and environmental integrity Description The is a stand-alone, microprocessor-based industrial controller designed for a broad range of process applications. It can serve as a simple single-loop controller or as a multi-loop controller with complete control and logic functions for a small unit batch or continuous process. The Model 353 s standard Ethernet communication enables it to function as an integral element in a plant system. using the L (Loop) & S (Station) indicator lights along with the priority assignments and flashing options of each alarm. User defined pushbuttons in each loop can be used for traditional functions, such as Console/Local, External/Internal Switching or individual user requirements, such as Start, Stop or Jog. Multiple variables are displayed on the operator faceplate and viewed using the D button. User defined units assigned to each variable are displayed via the UITS button. Complete configuration of the Model 353 is available using buttons located behind the flipdown ID door. A built-in library of preconfigured control strategies (FCOs) enable selection of common basic controller types for quick field set-up. A large selection of reusable function blocks enable simple changes to FCOs or the design of a custom control strategy to meet the needs of specific process control application. The Model 353 Configuration Utility accommodates design, downloading, uploading, and on-line monitoring capabilities for improved management of controller configurations. In addition, sequencer/logic loops can be configured and monitored on-line in ladder diagram format for those more familiar with this language. Loops are configured for control, sequence, or logic as needed within the Model 353. Each configured loop can have a virtual operator display that is viewed locally using the LOOP button on the faceplate and is mapped to network communication for a plant operator station. Alarm management is handled.1

Technical data Specifications Electrical & Environmental Power Supply Standard: 10/40 Vac (85 to 64 Vac); 47 to 63 Hz Optional: 4 Vdc, +0%, -15% Power Requirements 5 Watts, 40 VA (max.) -Wire Transmitter Power Voltage: 5 Vdc ±3V Current: 10 ma, short circuit protected Hazardous Area Approvals Pending FM/CSA: Class I, Division, Groups A, B, C & D ABS CE (Consult Siemens for current approvals) Ambient Temperature Range Operating: 3 to 1 F (0 to 50 C) Storage: -40 to 185 F (-40 to 85 C) Climate Conditions - IEC654-1 Class B3 - Standard Mounting Class D1 - Installed per instructions in Class D1 enclosure Electrostatic Discharge IEC 801- RFI Protection IEC 801-3 Electrical Transients IEC 801-4 et Weight 6 lbs. Heat Dissipation 80 BTU/Hr. Scan Time Varies with configuration: 0 msec (minimum) Inputs Analog Inputs (non-isolated) 1-5 Vdc, 4-0 ma with included 50 resistor MPU Controller Board: Qty 3 Digital Inputs (isolated) 0-1 Vdc OFF, 15-30 Vdc O MPU Controller Board: Qty 3. Analog Input, Universal (isolated) Thermocouple: J, K, T, E, S, R, B & RTD: DI 43760, US (BS16), JIS C-1604 Slidewire: 500-5000 Ohms: 0-5000 Millivolt: arrow: -19.0 to 19.0 mv; Wide:-30.0 to 77.0 mv I/O Expander Board: Qty Digital/Frequency Input, Universal (isolated) Frequency Range: 0 to 5,000 Hz Minimum Operating Frequency: 0.05 Hz O Voltage: 4-30 Vdc OFF Voltage: 0-1 Vdc Input Current: <5 ma @ 30 Vdc I/O Expander Board: Qty Outputs Analog Outputs (non-isolated) 4-0 ma into 800 ohms (max.) MPU Controller Board: Qty Digital Outputs (non-isolated) Open Collector Transistor (emitter @ station common) Load Voltage: 30Vdc (maximum) Load Current: 100 ma (maximum) Off State Leakage Current: <00 A @ 30 Vdc MPU Controller Board: Qty Relay Outputs (SPDT) Contact Rating: 5A @ 10 Vac,.5 A @ 30 Vac, Resistive Load Minimum Current: 100 ma @ 10 mvdc; 150 ma @ 50 mvac I/O Expander Board: Qty Optional Boards Local I/O Expander Communication Front configuration port: RS3 MODBUS Rear port: RS485 MODBUS Ethernet: MODBUS/TCP Standard Configuration ine of the most common control strategies have been stored in a built-in library and can be selected with a single pushbutton entry. These control strategies, which can be customized to accommodate individual needs, are: Single-Loop Controller with Tracking Setpoint Single-Loop Controller with Fixed Setpoint Ratio Set Controller with Operator Setpoint Limits Single-Loop Controller with Operator Setpoint Limits Cascade Loop Controller Cascade Loop Controller with Operator Setpoint Limits External Set Controller with Tracking Setpoint External Setpoint with Fixed Setpoint Dual Loop controller

Technical data Function Blocks Control strategies within the Model 353 are configured using the following function blocks, which are stored in memory. The total number and type of I/O function blocks available in the Model 353 depend on the installed hardware, and when available, can be used as needed within a configured loop. Loop function blocks can be used in the quantities indicated within each loop. Each configured loop can contain one operator display block & one controller block*. Station Hardware I/O AI1-4 - Analog Input AIU1- - Analog Input Universal AOUT1-3 - Analog Output DI1-4 - Digital Input DIU1- - Digital Input, Universal DOUT1- - Digital Output ROUT1- - Relay Output Ethernet Peer-To-Peer I/O AIE01-3 - Analog Input Ethernet AOE01-3 - Analog Output Ethernet AWE01-3 - Analog Write Ethernet CIE01-3 - Coil Input Ethernet CWE01-3 - Coil Write Ethernet DIE01-3 - Digital Input Ethernet DOE01-3 - Digital Output Ethernet DWE01-3 - Digital Write Ethernet Loop Function Blocks A/M - Auto/Manual ACS01-99 - ARC Cosine ADD01-99 - Addition AGA3 - Orifice Metering of atural Gas AGA7 - Measurement of Gas by Turbine Meters AGA8 - Compressibility Factors of atural Gas ALARM - Alarm AD01-99 - AD Logic AS01-99 - ARC Sine ATD01-05 - Analog Trend Display AT01-09 - Arc Tangent BATOT - Batch Totalizer BATSW - Batch Switch BIAS - Bias CHR01-99 - Characterizer CMP01-99 - Comparator COS01-99 - Cosine DAM01-99 - Deviation Amplifier DIV01-99 - Division DC01-99 - Divide by Counter DTM01-99 - Dead Time Table DYT01-99 - Delay Timer E/I - External/Internal Transfer ESL - Event Sequence Logger EXP01-99 - atural Exponentiation EXT01-99 - Exponentiation FTG01-99 - Falling Edge Trigger GB01-99 - Gain & Bias HLD01-99 - Hold ID* - ID Controller LL01-99 - Lead/Lag LMT01-99 - Limit L01-99 - atural Logarithm LOG01-99 - Logarithm Base 10 MTH01-99 - Math MUL01-99 - Multiplication D01-99 - AD Logic OR01-99 - OR Logic OT01-99 - OT Logic ODC* - Operator Display for Controllers ODS* - Operator Display for Sequencers ODA* - Operator Display for Analog ODD* - Operator Display for Discrete ODP* - Operator Display for Pushbutton OOFF* - O OFF Controller OR01-99 - OR Logic ORSL - Override Selector OST01-99 - One Shot Timer PB1SW - PB1 Switch PBSW - PB Switch PB3SW - PB3 Switch PCOM - Phase Communication PD* - PD Controller PID* - PID Controller PIDAG* - PIDAG Controller PRSEQ - Program Sequencer QHD01-99 - Quickset Hold RATIO - Ratio RCT01-99 - Repeat Cycle Timer RLM01-99 - Rate Limiter ROT01-99 - Retentive On Timer RSF01-99 - RS Flip-Flop RTG01-99 - Rising Edge Trigger RTT01-99 - Real Time Clock Trip SCL01-99 - Scaler SEL01-99 - Signal Selector SETPT - Setpoint SI01-99 - Sine SPLIM - Setpoint Limit SRF01-99 - SR Flip-Flop SRT01-99 - Square Root SUB01-99 - Subtraction TA01-99 - Tangent TH01-99 - Track & Hold TOT01-99 - Totalizer TSW01-99 - Transfer Switch XOR01-99 - Exclusive OR Logic OTE: Each configured loop can have one operator display block and one controller block..3

Ordering data Model umber Process Automation Controller w/ethernet Communication TGX: 353 Controller Board 10/40 Vac (85-64 Vac); 47-63 Hz 4 Vdc, +0%, -15% Mounting Case Standard Case with Ethernet Connector High Shock & Vibration Case w/ Ethernet Connector Operator's Display Panel Fixed Analog & Digital Displays Expander Board ot Required Local I/O Expander (T/C, RTD, Frequency, Relay,..) Multi Media Card MMC ModificationOption ot required Controller modified as detailed in order Bill of Material) Design Level Design Level B Electrical Approval ot required FM/CSA Class I, Div., Groups A, B, C, D suitable for non-incendive (CE Compliant) FM/CSA Class I, Div., Groups A, B, C, D suitable for non-incendive (CE Compliant & ABS Approved) Order o. - A D 4 5 F 1 C X B 4 W Sample Model umber TGX:353 A4 F CB 4.5