A. Work on this project shall consist of, but is not limited to, the following:

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Product Information/Specifications

RECOATING AND RENEWING SPF ROOFING SYSTEMS

Resurfacing Concrete. Page 1 of 5

XONYX Solid Surface Owner's Manual

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

White rust on galvanized and galvanized pre-painted steel. Technical Information

Sunbrella Care and Cleaning Instructions

Dow Corning AllGuard Silicone Elastomeric Coating. Application and Maintenance Guide

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Sto Specification R100. Guideline Specification for Repair of Exterior Insulation and Finish (EIFS) Wall Assemblies

Product Information/Specifications

VINYL SIDING CERTAINTEED CORPORATION L I M I T E D

SECTION Formatted Specification for the ULTRAFLOR DIAMATIC Topical Polished Concrete System DRAFT

T R A N S F E R A B L E F U L LY

Cedar Impressions Siding LIFETIME LIMITED

WARRANTY VINYL SIDING CERTAINTEED CORPORATION LIFETIME LIMITED

Minor Cracks in Horizontal Surfaces

SECTION POLISHED CONCRETE FINISHING

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

LIMITED LIFETIME CERTAINTEED CORPORATION VINYL SIDING PRODUCTS

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

Newfoundland and Labrador Paint Recycling Program Guidelines

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Installation Instructions

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

Section Polished Concrete Finishing. Vexcon

Managing Water Infiltration into Buildings. Water Damage Check List

Matte Finish Paint Owner s Guide. Matte Finish Paint Owner s Guide. Matte Finish Paint Owner s Guide 3. NP150-V2013 (Rev 06/11/12) Printing xx/xx/12

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

Operating Instructions

Acrylic Enamel Topcoat

Manufactured Stone Veneer Installation Instructions

Pictorial Surface Preparation Standards For Painting Steel Surfaces

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

GigaCrete Specification PlasterMax

3M Scotchkote Urethane Coating 165HB

G 2500 VH /06

TIMELY INFORMATION Flood Recovery

SECTION GUARDA SECURITY WINDOW SCREENS

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Smartstrand Cleaning Guidelines

care & cleaning guide

Dehumidifier Users manual. For Models: DH45S DH65S

Vacating Your Northwood III Apartment

Guide. to Common Brick Staining. in New Construction. improving the appearance and performance of buildings

SECTION 810 SEWER LINE CLEANING

PRODUCT INTENDED USE:

K2 STONE NATURAL VENEER

Introducing an All New Line of Cleaning Chemicals

SECTION 807 PUMP STATION REHABILITATION

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Product Guide. Products. Specialty. Construction

Basement Window Installation Guide Hopper and Sliding

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

dryvitcare EIFS Repair Procedures

3 WATT LED SPOTLIGHT Model No. SLM

COMMERCIAL BUILDING APPLICATIONS

BedRug Bedliner Installation Instructions. Part Number(s): Multiple. Preparation

Active and Passive Sash Replacement

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

INSTALLATION MANUAL. Glass Vessel Sink. I toll free: I Kraus USA Inc.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

PRODUCT DATA SHEET DESCRIPTION:

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

& CLEANING GUIDE MAINTAIN BEAUTY & PERFORMANCE

Attractive Durable Easy to maintain

Acrylic Walls Installation Instructions

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

SECTION 8 HANDLING AND MAINTENANCE CONTENTS

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

SURFACE PREPARATION. High pressure fresh water cleaning.

San josé OWNER S MANUAL

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

Application of Exterior Wood Finishes

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

How To Insure Against Problems With Your Home Warranty

CLEANING GUIDE.

DRYVIT SYSTEMS, INC. RESIDENTIAL MD SYSTEM AND SPRINT MD SYSTEM 30-YEAR WARRANTY AND MAINTENANCE AND CARE GUIDE

Selection, Use, and Care of Brushes

3 Masonry and Manufactured Stone (Interior and Exterior)

Primer-Sealers Solutions

Maintaining YOUR TILE ROOF

DryvitCARE Frequently Asked Questions

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes.

Transcription:

Sto Specification No. RC100 Guideline Specifications for Section No. 090170 Surface preparation for Sto restore Level 1 or Level 2 projects Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com Note: Depending on the size of the area to be cleaned and the tenacity of dirt or other accumulation on the surface, the tools used for cleaning will vary. Guideline specifications below may apply to all or part of a cleaning project, depending on the nature of the surface contaminants. In all cases, Sto recommends testing cleaning solutions and techniques on inconspicuous small areas to evaluate the effectiveness of the materials and methods that are proposed for use and to verify that unintended damage or adverse effects are not produced. Where commercially available cleaning products are to be used, verify applicability of the product for its intended use with the cleaning product manufacturer. The materials and techniques described below may be used on painted or coated concrete, masonry, stucco or EIFS. All materials and techniques are not necessarily appropriate for all substrates. Notes in italics, such as this one, are explanatory and intended to guide the design/construction professional and user in the proper selection and use of materials. This specification should be modified where necessary to accommodate individual project conditions. Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 1

Table of Contents PART 1 GENERAL...3 1.1 SUMMARY...3 1.2 RELATED DOCUMENTS...3 1.3 MATERIALS CLEANING SOLUTIONS...3 1.4 MILD DETERGENT WASH...3 1.5 EFFLORESCENCE REMOVAL...3 1.6 ALGAE AND MILDEW REMOVAL...4 PART 2 EXECUTION...4 2.1 GENERAL...4 2.2 APPLICATION OF CLEANING SOLUTIONS...4 2.3 HAND-SCRUBBING...5 2.4 PRESSURE WASHING (AS MEANS OF CLEANING EXISTING COATING)...5 2.5 PRESSURE WASHING (AS A MEANS OF REMOVING EXISTING COATING LAYERS)...5 Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 2

PART 1 GENERAL 1.1 Summary A. Provide cleaning of existing wall surface in preparation for resurfacing and/or recoating. 1.2 Related Documents ASTM D 4258 SSPC-SP 13/NACE 6 ICRI No. 03732 Sto Corp. Sto Corp. Standard Practice for Surface Cleaning of Concrete for Coating Surface Preparation of Concrete Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays StoTherm EIFS Reference Guide: Repair and Maintenance 1.01 Stucco Repair and Maintenance 1.3 Materials Cleaning Solutions A. General 1. Mix and use commercially available cleaning solutions in accordance with the cleaning product manufacturer s instructions. 2. Refer technical questions about specific commercial cleaning products to the cleaning product manufacturer. 3. Use and dispose of cleaning solutions and rinse water in accordance with applicable local regulations. 4. DO NOT USE solvent based cleaners (acetone, gasoline, ketones, mineral oils, or turpentine) 1.4 Mild Detergent Wash A. Solution of 1 2 cups tri-sodium-phosphate (TSP) or TSP substitute per gallon of warm water B. General Purpose Cleaner by Wind-lock Corp., www.wind-lock.com C. Wash Down by Demand Products, www.demandproducts.com D. EIFS Clean N Prep by PROSOCO, www.prosoco.com E. Other commercial general cleaners as recommended by the cleaning material manufacturer for the surface to be cleaned. 1.5 Efflorescence Removal A. Efflorescence and Scale Remover, by Demand Products B. Sentry Efflorescence and Scale Remover, by Wind-lock Corp. C. Other commercial efflorescence cleaners as recommended by the cleaning material manufacturer for the surface to be cleaned. Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 3

1.6 Algae and Mildew Removal A. Solution of ½ to 1 quart household bleach to 1 gallon of water (may be added to TSP detergent solution for general cleaning) B. Miracle Mildew Remover by Wind-lock Corp. C. Other commercial algae and mildew cleaners as recommended by the cleaning material manufacturer for the surface to be cleaned. NOTE: Bleach is not required if algae or mildew are not present, but existing algae or mildew will recur if bleach solution is not used) PART 2 Execution 2.1 General A. The techniques described in this section may be used on painted or coated concrete, stucco or EIFS surfaces. All techniques are not necessarily appropriate for all substrates. B. Test method and material in an inconspicuous area to verify techniques and materials to be used. C. Use the least aggressive means that produces effective results. D. Use methods in compliance with applicable local regulations. E. Protect adjacent construction, property and landscaping from overspray where cleaning solutions are used. F. Follow applicable regulations for personal protective equipment when performing cleaning. 2.2 Application of Cleaning Solutions A. Commercial cleaning products: 1. Select the appropriate cleaning solution and apply in accordance with the cleaning solution manufacturers recommendations. 2. Rinse thoroughly with clean water to remove all residue and surface contaminants. B. Generic mild detergent wash: 1. Apply mild detergent solution to the wall area to be cleaned. 2. Rinse thoroughly with clean water to remove all residue and surface contaminants. C. Generic algae and mildew removal: 1. Apply algae and mildew removal solution and allow to soak for minimum 15 minutes. (Reapplication may be necessary for severe growth). 2. Use hand-scrubbing technique to remove streaking or other localized growth. 3. Rinse thoroughly using clean water to remove all residue and surface contaminants. Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 4

2.3 Hand-Scrubbing A. Use hand scrubbing technique for localized stubborn stains that are resistant to low pressure washing techniques or otherwise require special treatment. B. Use soft to medium bristled brush C. Avoid overly aggressive scrubbing which could damage the existing coatings. NOTE: DO NOT USE stiff-bristled or wire brushes. 2.4 Pressure Washing (as means of cleaning existing coating) A. Use cool or warm water. DO NOT USE steam or high temperature methods when existing coatings are to remain in-place B. Use minimum 30 degree fan tip C. Determine distance from wall and pressure required to provide satisfactory results without damage to existing coatings or substrates based on test area. 1. Use pressure in the range of 2500 psi to 3000 psi for coatings applied to solid substrates (concrete, masonry, and stucco), unless undesirable effects are produced. If damage to existing coating occurs, adjust pressure, distance of tip from wall, or fan tip angle to achieve satisfactory results. NOTE: DO NOT USE high pressure on EIFS claddings. Limit pressure to 500 psi, maximum, when EIFS is the substrate. 2. Determine if architectural features are foam shapes to protect against accidental damage in cases where they are attached to solid substrates such as stucco, masonry or concrete. Limit pressure to 500 psi, maximum, for foam trim features. 2.5 Pressure Washing (as a means of removing existing coating layers) A. Determine pressure, fan tip angle and tip distance from wall as required to remove loose coatings or excess coating applications on solid substrates. B. Verify that the technique does not produce damage to the substrate and adjust as necessary. C. Dispose of rinse-water and waste in accordance with appropriate local regulations. NOTE: A chemical paint stripper may be an option to improve efficiency in combination with pressure washing when existing coatings are to be removed. Consult with the paint stripper manufacturer for proper use and disposal of rinse-water and waste. END OF SECTION Copyright 2015 Sto Corporation. All Rights Reserved. A copyright license to reproduce this specification is granted to specifying architects and engineers. Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 5

ATTENTION Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general contractor or builder. They should be installed in accordance with those specifications and Sto s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections, for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building components or assemblies, or for other construction activities beyond Sto s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or building may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPT FOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO S WARRANTY PROGRAMS WHICH ARE SUBJECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers, please refer to the Sto Corp. website, www.stocorp.com. Sto Guide Specification RC100 Sto Corp. is an ISO 9001:2008 and 14001:2004 Registered Company 6