APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors



Similar documents
ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

MAJORSINE Power Inverter

Rack mounted telephone- and leased line modem for industrial applications

AURORA. Photovoltaic Inverter & Wind Inverter. Power solutions for renewable energy sources and energy saving

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Operating Manual UWAPS-TINY Series

Telephone- and leased line modem for industrial applications TD-36

User s Manual Before using the inverter, you need to read and save the safety instructions.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ABB central inverters PVS to 1000 kw

Inductive Proximity Sensors

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

BITMAIN. APW PSU Series User Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

BB800 Off-Grid Solar System

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Redundancy Module QUINT-DIODE/40

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Emergency lighting units EM powerled

PCS0100en Persy Control Services B.V. Netherlands

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

GROWATT NEW ENERGY CO.,LTD. GR - UM

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Differential Charge Amplifier

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Pressure transmitter For general industrial applications Model A-10

ST Series POWER SUPPLIES USER INSTRUCTIONS

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Power Supplies 3. SDN-P DIN Rail Series

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

80 Series - Modular timers 16 A. Features

LOXONE 12 Channel Amplifier

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

User Manual for CH-PFC76810

CW46S GPS Sensor P R O D U C T B R I E F. Description. Features. Applications. Block Diagram

Modular I/O System Analog and Digital Interface Modules

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

for Energy Storage System, New & Renewable Energy

Your own power station: For continuous power

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SolarMax P series The power package for residential solar plants

38 Series - Relay interface modules A

Plug and Socket Devices CES 63 A Series 8579

Research RF Sputtering Packages

ACS-30-EU-EMDR-10-MOD

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

How To Power A Schen

MCR1900 Media Converter 19-Slot Chassis

User manual Rev. 1.2 (17/04/2015)

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

is then retained absolutely without interruption.

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Fronius IG Plus. The next generation grid-connected PV inverter

650W Single Output Power Supply

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

IRT Eurocard. Types DAX-3200

Relés e Contatores de Estado Sólido SIRIUS

Re-defining the utility-scale inverter

Kit Watt Audio Amplifier

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Intersection Preassembled 19-inch Rack

Three-phase monitoring relay CM-PFE

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Transcription:

APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN - Data Line Signal Return Common reference for logical signals. RJ45 connectors Pin # Signal Name Description 1 Not Used 2 Not Used 3 +TR + Data Line 4 +R Remote OFF Required or Remote OFF control. 5 -TR - Data Line 6 Not Used 7 RTN Signal Return Common reference for logical signals. 8 Not Used

APPENDIX B CABLE WIRING DIAGRAM FOR RS485 LINE

APPENDIX APPENDIX B RS485 CABLE SPECIFICATION SINGLE TWISTED PAIR RS485 CABLE SPECIFICATION Type of Cable RS485 EIA Application Cable Structure AWG 22-24 Charateristic Impedance 120 Ω Working Frequency 1 khz / 1 MHz DOUBLE TWISTED PAIR RS485 CABLE SPECIFICATION Type of Cable RS485 EIA Application Cable Structure 2 twisted pair, shielded AWG 22-24 Charateristic Impedance 120 Ω Working Frequency 1 khz / 1 MHz

APPENDIX C - TECHNICAL DATA MODEL PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTD INPUT PARAMETERS Nominal DC Power [kw] 3,12 3,75 4,375 Max. Recommended DC Power [kw] 3,5 4,15 4,82 Operating Input Voltage Range [V] 0,7xVstart - 580 (360 nominal) Full Power MPPT input voltage range (symmetrical load) [V] 160-530 120-530 140-530 Full Power MPPT input voltage range (asymmetrical load) [V] 200-530 (@ 2kW) / 112-530 (@ 1,12kW) 190-530 (@ 3kW) / 90-530 (@ 0,75kW) 190-530 (@ 3kW) / 90-530 (@ 1,38kW) Absolute Max. Input Voltage [V] 600 Activation voltage Vstart [V] 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) No of independent MPPT trackers 2 Max. Input Power, each MPPT [kw] 2 3 No. of DC Inputs 2 ( 1 each MPPT ) 3 ( 2 for MPPT1, 1 for MPPT2 ) Max. DC Current, each MPPT [A] 10 ( 12,5 short circuit ) 16 ( 20 short circuit ) 4 (2 positive, 2 negative) 6 (3 positive, 3 negative) DC Connection Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable Ø w/insulator: 3-6mm INPUT PROTECTION Reverse polarity protection Yes Fuse rating, each input (-FS suffix versions only) NA NA NA Thermally Protected DC side varistor 4 ( 2 for each MPPT ) PV array Insulation Control DC Switch (-S/-FS suffix versions only) Integrated (Rating : 600Vdc / 25A) OUTPUT PARAMETERS Nominal AC Power [up to 50 C, kw] 3 3,6 4,2 Max. AC Power [kw] 3,3 4 4,6 AC Grid Connection single phase ( Live, Neutral, PE ) Nominal AC Voltage [V] 230 AC Voltage Range [V] 180-264 (may vary to comply with regulations in each country) Nominal AC Frequency [Hz] 50 Max. AC Line Current [A] 14,5 ( 16 short circuit ) 17,2* ( 19 short circuit ) 20 ( 22 short circuit ) Screw terminal block AC Connection Conductor cross section: Solid 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M25 - Cable Ø: 10-17mm Line Power Factor >0,995 AC Current Distortion [THD%] <3,5% at rated power with sine wave voltage OUTPUT PROTECTION AC side varistors 2 ( Live - Neutral / Live - PE ) Ground fault protection (AC + DC leakage current) ENVIRONMENTAL PARAMETERS Cooling Natural cooling Ambient Temp. Range [ C] above 50 C) above 55 C) above 50 C) Opertaing Altitude [m] 2000 Acoustical Noise [dba] < 50 @ 1mt Environmental IP Rating IP65 Relative Humidity 0-100% condensing MECHANICAL Dimensions [H x W x D] 547 x 325 x 210 Overall Dimensions (whit flanges) [H x W x D] 689 x 325 x 222 Weight [kg] (*) Limited to 16A for UK G83/1 Version.

APPENDIX APPENDIX C - TECHNICAL DATA MODEL PVI-5000-TL-OUTD PVI-6000-TL-OUTD INPUT PARAMETERS Nominal DC Power [kw] 4,8 6,2 Max. Recommended DC Power [kw] 5,75 6,9 Operating Input Voltage Range [V] 0,7xVstart - 580 (360 nominal) Full Power MPPT input voltage range (symmetrical load) [V] 150-530 180-530 Full Power MPPT input voltage range (asymmetrical load) [V] 220-530 (@ 4kW) / 90-530 (@ 0,8kW) 220-530 (@ 4kW) / 120-530 (@ 2,2kW) Absolute Max. Input Voltage [V] 600 Activation voltage Vstart [V] 200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input) No of independent MPPT trackers 2 Max. Input Power, each MPPT [kw] 4 No. of DC Inputs 4 (2 each MPPT) Max. DC Current, each MPPT [A] 18 (22 shortcircuit) DC Connection Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable Ø w/insulator: 3-6mm INPUT PROTECTION Reverse polarity protection Yes Fuse rating, each input (-FS suffix versions only) NA NA DC side varistors 4 ( 2 for each MPPT ), thermally protected PV array Insulation Control DC Switch (-S/-FS suffix versions only) Integrated (Rating: 600Vdc / 25Adc) OUTPUT PARAMETERS Nominal AC Power [up to 50 C, kw] 5(**) 6 Max. AC Power [kw] 5(**) 6 AC Grid Connection Nominal AC Voltage [V] 230 AC Voltage Range [V] 180-264 (may vary to comply with regulations in each country) Nominal AC Frequency [Hz] 50 Max. AC Line Current [A] 25 (32 short circuit) 30 (40 short circuit) Cage-clamp terminal block AC Connection Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M32 - Cable Ø: 13-21mm Line Power Factor >0,995 AC Current Distortion [THD%] <3,5% at rated power with sine wave voltage OUTPUT PROTECTION AC side varistors 2, plus gas arrester to ground Ground fault protection (AC + DC leakage current) ENVIRONMENTAL PARAMETERS Cooling Natural cooling Ambient Temp. Range [ C] Opertaing Altitude [m] 2000 Acoustical Noise [dba] <50 @1mt Environmental IP Rating IP65 Relative Humidity 0-100% condensing MECHANICAL BOX Dimensions [H x W x D] 740 x 325 x 208 Overall Dimensions (whit flanges) [H x W x D] 910 x 325 x 222 Weight [kg] 26 (**) Limited to 4600W for Germany.

(***) Limited to 10000W for Benelux. APPENDIX C - TECHNICAL DATA MODEL PVI-10.0-TL-OUTD PVI-12.5-TL-OUTD INPUT PARAMETERS Nominal DC Power [kw] 10,3 12,8 Max. Recommended DC Power [kw] 11,4 14,3 Operating Input Voltage Range [V] 0,7xVstart - 850 (580 nominal) Full Power MPPT input voltage range (symmetrical load) [V] 300-750 360-750 Full Power MPPT input voltage range (asymmetrical load) [V] 380-750 (@ 6,8kW) / 195-750 (@ 3,5kW) 445-750 (@ 8kW) / 270-750 (@ 4,8kW) Absolute Max. Input Voltage [V] 900 Activation voltage Vstart [V] 360 nominal (adjustable within the range 250Vdc-500Vdc, independently/each input) No of independent MPPT trackers 2 Max. Input Power, each MPPT [kw] 6,8 8 6 (3 each MPPT, optionally fused) in PVI-10.0/12.5-TL-OUTD No. of DC Inputs and in PVI-10.0/12.5-TL-OUTD-FS version 4 (2 each MPPT) in PVI-10.0/12.5-TL-OUTD-S version Max. DC Current, each MPPT [A] 18 (22 shortcircuit) in PVI-10.0/12.5-TL-OUTD and in PVI-10.0/12.5-TL-OUTD-FS version DC Connection in PVI-10.0/12.5-TL-OUTD-S version Mating cable connector included Conductor cross section: 4-6mmq/AWG12-10 - Cable Ø w/insulator: 3-6mm INPUT PROTECTION Reverse polarity protection Yes Fuse rating, each input (-FS suffix versions only) 10Adc / 900Vdc DC side varistors 4 ( 2 for each MPPT ), thermally protected PV array Insulation Control DC Switch (-S/-FS suffix versions only) Integrated (Rating: 1000Vdc / 25Adc) OUTPUT PARAMETERS Nominal AC Power [up to 50 C, kw] 10 12,5 Max. AC Power [kw] 11(***) 13,8 AC Grid Connection Nominal AC Voltage [V] 400V AC Voltage Range [V] 320-480Vac (may vary to comply with regulations in each country) Nominal AC Frequency [Hz] 50 Max. AC Line Current [A] 16,6A per phase (19A short circuit) 20A per phase (22A short circuit) Screw terminal block AC Connection Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6 Cable Gland: M40 - Cable Ø: 19-28mm Line Power Factor >0,995 AC Current Distortion [THD%] <2% at rated power with sine wave voltage OUTPUT PROTECTION AC side varistors 3, star connected to common point, plus gas arrester to ground Ground fault protection (AC + DC leakage current) ENVIRONMENTAL PARAMETERS Cooling Natural cooling Ambient Temp. Range [ C] Opertaing Altitude [m] 2000 Acoustical Noise [dba] <50 @1mt Environmental IP Rating IP65 Relative Humidity 0-100% condensing MECHANICAL BOX Dimensions [H x W x D] 645 x 645 x 211 Overall Dimensions (whit flanges) [H x W x D] 716 x 645 x 224 Weight [kg] 38