Structural Design of Multi-story Residential Building for in Salem, India



Similar documents
Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

SEISMIC RETROFITTING OF STRUCTURES

How To Design A Post Tensioned Deck For A Building

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Optimum proportions for the design of suspension bridge

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Technical Notes 3B - Brick Masonry Section Properties May 1993

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Technical Assignment 2 TABLE OF CONTENTS

9.3 Two-way Slabs (Part I)

Advanced Structural Analysis. Prof. Devdas Menon. Department of Civil Engineering. Indian Institute of Technology, Madras. Module

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

AASHTOWare Bridge Design and Rating Training. STL8 Single Span Steel 3D Example (BrDR 6.6)

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

Finite Element Method (ENGC 6321) Syllabus. Second Semester

New approaches in Eurocode 3 efficient global structural design

A Case Study Comparing Two Approaches for Applying Area Loads: Tributary Area Loads vs Shell Pressure Loads

Seismic performance evaluation of an existing school building in Turkey

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

The Basics of FEA Procedure

In-situ Load Testing to Evaluate New Repair Techniques

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

How To Write An Analysis System For Bridge Test

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Aluminium systems profile selection

Structural Audit of Buildings

[TECHNICAL REPORT I:]

Seismic Risk Prioritization of RC Public Buildings

bi directional loading). Prototype ten story

STATIC STRUCTURAL ANALYSIS OF SUSPENSION ARM USING FINITE ELEMENT METHOD

Reinforced Concrete Design

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

Designing a Structural Steel Beam. Kristen M. Lechner

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

The elements used in commercial codes can be classified in two basic categories:

Formwork for Concrete

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

DYNAMIC ANALYSIS OF THICK PLATES SUBJECTED TO EARTQUAKE

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

CH. 2 LOADS ON BUILDINGS

Structural Analysis. EUROCODE 2 Background and Applications

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Specification for Structures to be Built in Disaster Areas

Sisal Composite Ltd. Apparel 4 Ltd. JM Knit Ltd. Natun Para, Hemayetpur, Savar, Dhaka-1340 ( N, E)

ick Foundation Analysis and Design

SAFE. Key Features and Terminology DESIGN OF SLABS, BEAMS AND FOUNDATIONIS REINFORCED AND POST-TENSIONED CONCRETE

A project report on, Prepared in partial fulfillment of. Study oriented project, Course code: CE G611 Computer Aided Analysis and Design

Civil Engineering and Architecture (CEA) Detailed Outline

Guidelines for the Design of Post-Tensioned Floors

Plates and Shells: Theory and Computation - 4D9 - Dr Fehmi Cirak (fc286@) Office: Inglis building mezzanine level (INO 31)

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

Page & Turnbull imagining change in historic environments through design, research, and technology

How To Build A Luxury Apartment Complex In London

The International Journal Of Science & Technoledge (ISSN X)

COMMONLY USED RESIDENTIAL BUILDING CODES

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Introduction to Beam. Area Moments of Inertia, Deflection, and Volumes of Beams

Personal Information. Professional Education

HOUSE BUILDING DIGEST

INTRODUCTION TO LIMIT STATES

Professional Engineers Providing Structural Engineering Services In Buildings

Seismic Analysis and Design of Steel Liquid Storage Tanks

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

CHAPTER 2 QUANTITY TAKE-OFF

Design of an Orphanage, Learning and Community Center in Ethiopia Abstract

ASHULIA APPARELS LTD. Client Summary Report

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

Statics of Structural Supports

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

POST AND FRAME STRUCTURES (Pole Barns)

Modeling Beams on Elastic Foundations Using Plate Elements in Finite Element Method

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Optimising plate girder design

Tower Cross Arm Numerical Analysis

Egcobox Software Manuel Version Max Frank GmbH & Co. KG

Joist Models in Standard Structural Software

Transcription:

ASEE Conference at WPI, March 17, 2006. Structural Design of Multi-story Residential Building for in Salem, India P. Jayachandran* and S. Rajasekaran@ *Worcester Polytechnic Institute, Worcester, MA 01609, @PSG College of Technology, Coimbatore, Tamil Nadu, India, 641014 INTRODUCTION The structural analysis and design aspects of a four story reinforced concrete building, designed and built in Salem, Tamilnadu State, India, is described herein. The design was referred to the second author for proof checking. The building is an apartment complex proposed by the Tamil Nadu Housing Board. This is a reinforced concrete framed building. This was done at the PSG College of Technology, Coimbatore, India, as a part of senior thesis design at WPI, in Worcester MA, 01609 at the India Project Centre at PSG College of Technology, Coimbatore, India, for a period of 7 weeks as a residential student project. The students names are Frederic Carrie, Abraham Pinales and Antonio Durate. This was accomplished as their project centre in PSG College of Technology, Coimbatore, India, during the year 1998. This was part of the degree requirements for BSCE in Civil and Environmental Engineering at WPI. WPI sent 20 students to the India Projects program at PSG College of Technology, Coimbatore, under the sponsorship of Dr. S. Rajasekaran, Chair, CEE Department at PSG College of Technology. Professor S. Rajasekaran served as the on campus advisor, while Professor P. Jayachandran, served as an off-campus advisor at WPI. The students did a literature survey, problem definition and did a complete structural analysis and design of the four story residential building in reinforced concrete. They followed the Indian code BIS 456 1978 and used ACI-1999 and wind/earthquake loads by using Canadian Code 1995, and ANSI standards 1995 for checking. The analysis and design of slabs, beams, girders, columns and footings were completed using theory from Reinforced Concrete Design and Structural Analysis by STAAD-III software, which uses finite elements. Design for slabs, beams, columns and footings were carried out using the software RC Design Suite. Drawings were done using Auto-CAD. To prevent the misuse of these software applications, the Limit State Design was exclusively used as a hand calculation method to verify the output from STAAD-III and RC Design suite. Estimating and quantity surveying was done to calculate quantities and specifications for construction and fabrication. The drift was kept to within H/500, where theory for design adapted was, from textbooks by C.K. Wang and C.G. Salmon in Reinforced Concrete Design and J.G.McGrager, Reinforced Concrete Design, and S.Rajasekaran, Finite Element Method. The students have completed structural design and drawings and a technical report and made a presentation of results, before an audience of Senior Professors and other faculty members and students of PSG College of Technology as well as at WPI. This project

was awarded a Provost s Award at WPI. WPI will be sending a group of students to PSG Tech in 2006. This is being examined at WPI. DESIGN SPECIFICATIONS The three dimensional view of the building is shown in Fig.1 and the plan view is given in Fig.2. The geometrical properties of the structure included a maximum length spanning 48.27 meters, and a maximum width of 31.60 meters. The building comprised of 2.9 meter floors and spanned 11.6 meters above grade. A wall beam was provided 0.75 meters below grade to support the earth pressure against supporting columns above the footings of the structure. At the roof level, a mechanical room was provided for the elevator of the complex. ( 1metre = 3.281 feet ) Each typical floor consisted of 8 apartments. The slab of the bath room was depressed approximately 0.6 meters and was accounted for in the beam design around the toilet rooms. A balcony was attached to each apartment, and the loading was accounted for in the floor beam design. The Indian code BIS 456-1978 was used using the concrete mix with 15 MPa and 415 MPa reinforcing steel. The surrounding conditions indicated a low seismic, and a strong soil layer boundary with a strength of 150 KN/sq.m. As indicated, the height to width ratio of the structure did not exceed 2, therefore a wind analysis was not required according to the Indian Code. Due to the monsoon season, the Indian Code included a specific loading for the roof of the structure. ASSUMPTIONS MADE 1. Only centre line dimensions are taken 2. The base joints are assumed to be hinged and assumed to be at a depth of 3.35 m below ground level. 3. Half of the structure is considered because of symmetry and on the symmetric axis suitable boundary conditions are applied 4. Even though the beam behaviour is like a T beam over a certain length of span, moment of inertia is calculated based on the rectangular beam. This is on the conservative side. 5. The following three loading conditions are considered a) dead load b) live load c) 1.5 dead load + 1.5 live load. Since the design is carried out using limit state design load factor of 1.5 is used. 6. The live load on the slab is assumed as 3 kn/sq.m and the self weight of slab + floor finish (assuming 120 mm thick ) is taken as 4 kn/sq.m and the total load on the slab is taken as 7 kn/sq.m for all floors except roof for which 10kN/sq.m is considered. Based on slab load and 45 degrees distribution the loads for beams for all floors are considered. 7. In addition, the wall load assuming the self-weight of masonry as 20 kn/cu.m is taken as 13.34 kn/m for full brick wall and 6.67 kn/m for half brick wall. 8. The slab is assumed to be 120mm thick, floor and roof beams are assumed as 230 x 450 mm or 230 x 400 mm as the case may be and the concrete columns are assumed

to be 230x380 and some columns are assumed to be 230 x 450. The columns in the lift portion are assumed to be 230 x 230 9. The safe bearing capacity of the soil is taken as 150 kn/sq.m ANALYSIS BY STAAD-III Staad-III is a finite element analysis and design software system and was developed by Research Engineers Inc. In addition to the analysis and design complete graphical interface is included in this package. The following are the main options available from the concurrent Graphics environment. STAAD-III - Analysis and Design STAAD-III Graphical Input Generator STAAD-POST Graphical post processing STAAD-INTDES Interactive Design of structural components This package can perform static analysis, second order stability analysis and dynamic analysis. It uses 2 or 3 dimensional frame elements, grid elements, and continuum elements and spring elements. Extensive design capabilities are available in STAAD- III/ISDS for steel, concrete, timber and pre-stressed sections. Interactive design consists of design for footing, slab and retaining walls. One can also get deformed shape, bending and shear and axial forces diagrams. Displacements are also checked for ACI, Canadian and Indian Standards. SIX STEPS IN THE ANALYSIS The following six steps are used in the Finite element analysis of any structure. 1. Idealize the structure into a number of elements 2. Develop the element stiffness matrix using constitutive law. 3. Assemble the element stiffness to form global stiffness matrix using compatibility and equilibrium. 4. Apply necessary boundary conditions 5. Solve the equations [K]{r}={R} where [K] is the structural stiffness matrix, {r} generalized displacements and {R} generalized forces. 6. Knowing the displacements solve for elemental stresses. The four story-building complex included a 3 dimensional mesh arrangement consisting of 2212 nodes with total of 6 degrees of freedom at each node. This model required a total of 13272 equilibrium equations to be solved in the form of a matrix system, ad in order to compute bending moments and displacements. Fortunately, the building contains a symmetry line, which permitted the analysis of half of the structure, therefore reducing the mesh arrangement to 1106 nodes and the number of equations was reduced to a total of 6636 equations which were solved using STAAD-III. The renumbering of nodes is automatically done so as to reduce the bandwidth. Reducing the number of equations and reducing the bandwidth of the matrix system to be solved, which alternatively required less time from cpu point of view. This factor is extremely important especially in the

industry since most companies operate on a network basis, which could ultimately affect the daily productivity. It also reduces the chance of human error in the input file which consists of over 2500 lines of the code. RC-DESIGN SUITE RC Design suite is a reinforced concrete design program that has numerous applications for the design of concrete structures. It contains modules for the design of beams, columns, footings and slabs. For this project the students utilized this program only for the design of floor slab and combined footings. This program will also be used in the partial design of the raft footing. Design of beams and columns are carried out in STAAD- III package itself. A clear cover of 20 mm is adopted for the slab. For each column load the individual footing is designed. However, many of these individual footings overlapped each other and had to be redesigned as combined footings. RC Design suite provided an effective way of designing these combined footings through its footing design module. The footing design module of the program provides the footing length, effective depth and reinforcement requirements. The raft footing was designed in the area under the lift duct of the building. Some criteria dictated that the support to the elevator shaft should be watertight. RC-Design Suite was used to engineer the design of the raft. Four column loads of 562 kn, 425 kn, 832 kn and 498 kn are being transmitted to the four corners of the raft of the lift well. The design of the raft footing was modelled adopting an inverted slab-beam-column approach. To prevent deterioration in the footing, associated with the position of the water table, it was decided that a raft footing would be beneficiary since its depth would be considerably less than a conventional shallow or combined footing. The thickness of the raft was 0.6 m. IMPORTANCE OF HAND CALCULATIONS The students have been asked to perform hand calculations. Computer analysis and design programs offer great benefits to the design engineer. However, the computer programs can be easily misused without proper precautions in analysis and design procedures. If the design of any structure is based on the results obtained from erroneous computer analysis, it can lead to structural failures, costly disputes and poor performing structures. Performing the following procedures can eliminate many of the errors. 1. Model the structure as closely to the real structure as possible. 2. Recognize the important structural reactions 3. Check the input and understand the material behaviour and boundary conditions 4. Perform simple equilibrium and compatibility checks using hand calculations. 5. Know and understand the limitations of the software. A series of hand design calculations were performed on a typical slab panel, a randomly selected set of three beams and columns, one critical footing supporting the highest column load in the structure, and a typical combined footing. The purpose of the hand design calculation was to verify manually, the analysis from the finite element software package, STAAD-III and the Indian code driven RC Design Suite programs.

WHAT THE STUDENTS LEARNT IN THE MAJOR QUALIFYING PROJECT 1. To use Autocad to sketch the floor plan (see Fig.2) and the details of the frame and foundations of the structure and also the details of beam etc as shown in Fig.3 2. To use Microsoft EXCEL to facilitate the computation of the service loads on the structure. 3. To use STAAD-III package for the analysis of four storied apartment complex 4. To familiarize with Indian Code BIS 456-1978 and other American and Canadian codes. 5. To use RC Design Suite for the design of slabs and combined footings. REFERENCES 1. Annonymous, Bureau of Indian Standards Indian Standards Code of Practice for Plain and Reinforced Concrete : IS 456 1978, New Delhi, 1996. 2. Annonymous, Bureau of Indian Standards Design Aids for Reinforced Concrete to IS : 456-1978, New Delhi, 1996. 3. Rajasekaran,S. Finite Element Analysis in Engineering Design, Wheeler publishing, Allahabad, 1994. 4. McGregor, J.G. Reinforced Concrete Mechanics and Design, Prentice Hall, New Jersey, 1997. 5. Carrie, F., Pinales, A. and Duarate, A., Structural Analysis and Design of Multi- Story Building in Salem, India, Major Qualifying Project submitted for BSCE Degree, Worcester Polytechnic Institute, Worcester, MA., and PSG College of Technology, Coimbatore, India, 1998 - A Global Studies Project under IGSD of WPI. ABSTRACT The structural analysis and design of 4 story multistory building complex for the hostel for legislators of Tamil Nadu State in Salem, Tamil Nadu, in India, is described herein. This is a result of a senior thesis project completed by 3 senior students, Fred Carrie, Abraham Pinales and Antonio Duarte, of Worcester Polytechnic Institute, Worcester, Massachusetts, carried out at its India Project Centre, at PSG College of Technology, Coimbatore, India. Salem is a sister city of Salem, Massachusetts. Gravity and Lateral loads were determined using Canadian Code 1995, ANSI Standards 1995 and Indian Standards 1990. Stress analysis was conducted using finite elements, and utilizing STAAD3 software system. Structural design was accomplished for reinforced concrete slabs, beams, girders, columns and footings, based on this stress analysis an its resultants. Design drawings were prepared, and specifications written for construction. Dr.S.Rajasekaran, the second author was the structural consultant for proof checking of the building s design by its project structural engineers. The students project verified some aspects of this peer review of design. Students traveled to India and did this project at PSG College of Technology, under the guidance of Profs. P. Jayachandran and S. Rajasekaran. WPI global studies division has sponsored this 7-week residential project in

India. The students have reported that this project was a life changing experience for them, as they learned about design in India, and its culture and its people. BIOGRAPHICAL SKETCHES Dr. P.Jayachandran is on the faculty of Civil and Environmental Engineering at WPI, Worcester, Massachusetts. He has design experience as Senior Engineer at CBM Engineers, Inc., Houston, TX, which has designed the tallest buildings in Los Angeles, Houston, Dallas, New Orleans, Washington, DC., and in St.Louis. He was also a Research Engineer in Structural Engineering Research Centre, Madras, India, a national laboratory. He has Ph.D from University of Wisconsin, Madison, WI. See www. sercm@nic.in and also www.wpi.edu Dr.S.Rajasekaran is the Chair of Infrastructure Engineering and CEE at PSG College of Technology, Coimbatore, India. He is an expert in Non-linear FEM, and has recently carried out non-linear FEM based stress analysis, for the design of LCA-Light Combat Aircraft, for the ADA-Aeronautical Development Agency, Bangalore, India. PSG College of Technology is a top 10 school in India in Science and Technology. He has Ph.D from University of Alberta, Edmonton, Canada, and D.Sc. from Bharathiar University, India. See www.psgtech.edu

Figure 1-Three Dimensional View

Figure 2-Typical Floor Plan

Figure 3-Typical Beam Design