Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P



Similar documents
Bimetallic Overload Relay Specifications

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

CompactLogix Power Supplies Specifications

1756 ControlLogix Chassis Specifications

1788 Linking Device Specifications

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Rotary Disconnect Switch Specifications

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Model #: SMART2200CRMXL

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

SMC -3 Specifications

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Bulletin 1609 Uninterruptible Power Supply

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

USB-to-Data Highway Plus Cable

Back-UPS Pro 1300/1500 Installation and Operation

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Uninterruptible Power Supply

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Installation and Operation Back-UPS 1250, 1300, 1500

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

BC Pro UPS System Standby UPS System

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

MAJORSINE Power Inverter

Legacy PanelView to PanelView Plus 6 Catalog Number Conversions

BB800 Off-Grid Solar System

HP UPS R1500 Generation 3

PowerGem Pro Uninterruptible Power Supply

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

R5000 Uninterruptible Power System (UPS) Overview

Installation and Operation

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

1756 ControlLogix Power Supplies Specifications

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Internet Office 500VA Tower Standby 120V UPS with USB port

PE8216/PE8324. Energy Intelligence Solutions

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Reference Manual. Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

LAP ENERGIA PARA DATACENTERS

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

Cisco Redundant Power System 2300

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Internet Office UPS System Standby UPS for PCs, workstations and more

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

EKOS Cart. Instructions for Use

BroadBand PowerShield. User Manual

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

R5000 Uninterruptible Power System (UPS) Overview

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

MicroLogix 1100 Embedded Web Server

LT-82 Stationary IR Transmitter

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

APC Smart-UPS 2400/3000 VA 100/ VAC 3U. Uninterruptible Power Supply

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Stratix 5700 Switch Configuration

Thyristor-controlled power supplies and battery chargers

ADM1TE 5/30A DIN rail single phase two wire energy meter

Smart-UPS On-Line 230 V

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Manual. Solar Fountain Mobile Phone Charger

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

User s Manual Before using the inverter, you need to read and save the safety instructions.

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Transcription:

Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.ab.com Description Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

1609-P Tower Uninterruptible Power Supply Specifications Specifications Input Output On Battery Efficiency Protection Regulatory Battery Pack Environment Rear Panel Communication Indicators and Controls Electrical Ratings 1609-P3000N 1609-P3000A 1609-P5000E 1609-P8000E 1609-P10000E V nom. (V AC) 120 230 208/230 208/230 208/230 Voltage Range, default (V AC) 90 150V 160 280V Current (A) 20 nom., 28 max. 11 nom., 14 max. 19 nom., 24 max. 30 nom., 40 max. 39 nom., 48 max. Capacity 3000VA (2100 W) 5000VA (3500 W) 8000VA (6400 W) 10 000VA (8000 W) Frequency 45 65 Hz (self sensing) PFC > 0.95 Protection N/A N/A N/A 70 A input circuit breaker V nom. 120V 208V Capacity 3000VA (2100 W) 5000VA (3500 W) 8000VA (6400 W) 10 000VA (8000 W) Protection 3 15 A circuit breaker N/A N/A Frequency Reg. THD +/- 2% static +/- 5% dynamic Nominal +/- 3 Hz +/- 1% static, +/- 5% dynamic <5% at full load Crest Factor 3:01 On Battery 86% On Line 88% Surge IEC 1000-4-4 Overload Output Short Thermal Protection 125% : 1 minute, 150% : 30 seconds Input circuit breakers and/or premises branch protection Bypass N/A 70 A input circuit breaker Safety UL 1778, culus, IEC 60950 Yes EN 61000-3-2 UL 1778, culus, IEC 60950 EMC FCC (Class A) EN50091-2 FCC (Class A), EN50091-2 Markings culus, CSA CE culus, CSA, CE Run Time Type Voltage Charger Recharge Time Lifetime Temperature Altitude Humidity Heat Output (Full Load) Audible Noise AC Outlets 14 minutes @ full load, 34 minutes @ half load Less than 3 hours to 90% capacity <50 db @ 1 meter (full load) (6) NEMA 5 15 (2) NEMA 5 20 5 7 minutes @ full load, 13 18 minutes @ half load Sealed Lead Acid, valve regulated, hot swappable, user replaceable 192V Temperature compensated current limited, float charger Less than 3 hours to 85% capacity 2 4 years @ 25 C ambient 0 40 C (operating), -20 60 C (short term storage) 10 000 ft (operating) 0 95% non-condensing (operating) 655 BTU/hour 1040 BTU/hour 1536 BTU/hour 2216 BTU/hour (8) IEC C13 (2) IEC C19 <55 db @ 1 meter (full load) (12) IEC C13 (2) IEC C19 AC Inlets NEMA L5 30 IEC C14 IEC C20 3 position terminal blocks DB9 Serial and Contact Closures EPO Via Contact Closure Network Via Network Management Card (1609-NMC, provided as standard with units >3 KVA) LED Status On-line, In Bypass Mode, On Battery, Overload and Replace Battery, Fault, Bar graph for Load, Bar graph for Battery Fuel Gauge, Bar graph for Measured Input Voltage when recessed switch is held Control (Front panel) On/self-test/alarm silence/cold start/load off On Battery: 4 short beeps repeats about 20 seconds (mutable), Low Battery: persistent 0.5 second beep every 1 Audible second (mutable), In Bypass: continuous beeping, Failure: continuous tone, Replace Battery: occasional on/off change - single beep Wiring of the UPS should be performed by a qualified electrician. Use appropriate size wires. In 230V AC applications, the UPS must be protected with a circuit breaker that complies with European standards for branch rated protection per the country of installation. In 208V AC applications, the UPS must be protected by a dual-pole, 10 A branch rated, UL 489 circuit breaker. The 120V AC 1609-P3000N has supplementary circuit breaker protection. The unit should be protected by a singlepole, 15 A branch rated, UL 489 circuit breaker. Allen-Bradley part number 1492-MCAA115 is suggested. The branch circuit breaker must be off prior to wiring the unit. 2 Rockwell Automation Publication -1609-TD001A-EN-P

1609-P Tower Uninterruptible Power Supply Approximate Dimensions Notes 208V AC applications: The 1609-P5000E, 1609-P8000E, and 1609-P10000E, ship ready for 230V AC sources. When operating one of these in 208V AC applications, the UPS low transfer voltage settings are adjusted through the PowerChute software or the Network Management Card. Refer to the PowerChute User Guide or the Network Management Card instructions for details. Approximate Dimensions and Shipping Weights Approximate dimensions are shown in millimeters (in.) unless otherwise indicated. Dimensions are not to be used for manufacturing purposes. (25.3) (5.1) (25.3) (10.3) Approximate Shipping Weights Output Power Input Voltage Cat. No. Approx. Shipping Weight [kg (lb)] 3000VA (2100 W) 120V AC 1609-P3000N 63.5 (140) 3000VA (2100 W) 230V AC 1609-P3000A 63.5 (140) 5000VA (3500 W) 208/230V AC 1609-P5000E 63.5 (140) 8000VA (6400 W) 208/230V AC 1609-P8000E 128.8 (284) 10000VA (8000 W) 208/230V AC 1609-P10000E 128.8 (284) Approximate dimensions are shown in millimeters (in.) unless otherwise indicated. Dimensions are not to be used for manufacturing purposes. Rockwell Automation Publication -1609-TD001A-EN-P 3

1609-P Tower Uninterruptible Power Supply Approximate Dimensions (22.8) (3.7) (4.8) (25.3) (5.1) (25.3) (5.1) Approximate Shipping Weights Description Cat. No. Approx. Shipping Weight [kg (lb)] Replacement battery 1609-PBAT 37.2 (82) External battery pack 1609-PXBP 101.2 (223) 5000VA CCT (120V step down transformer) 1609-5000CCT 63.5 (140) Rail kit 1609-PRK1 3.6 (8) 4 Rockwell Automation Publication -1609-TD001A-EN-P

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 1609-TD001A-EN-P - August 2014 Copyright 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.