RF 1. Contents: Connecting diagram. Detailed information:



Similar documents
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

HERZ-Thermal Actuators

Wireless Thermostats 230v and Battery Operated Instruction Manual

EK908FHL - Thermostat for floor heating

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

evohome Wireless Radiator Zoning Kit Installation & User Guide

HCE80/HCC80/HCE80R/HCC80R

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

ELECTRIC CENTRAL HEATING FLOW BOILER

T5000 T000 LCD Digital Fan Coil Thermostat

Adjustable room thermostat for heating only or cooling only systems

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

B/S/H/ Error codes and service programmes PH

Wireless 7 Day Programmable Room Thermostat

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Centro-Matic Automatic Lubrication Systems System Controls

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

MAGICAR M871A. Car alarm with two-way remote User s guide

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Installation Guide. DEVIreg 530. Electronic Thermostat.

Thermostat with display

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Mode Switch. Fan Switch Menu button Program button

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Thermostats. comfort at your command

Inwall Room Temperature Unit

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

G-100/200 Operation & Installation

Overview - Danfoss Link and living software versions

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Please read the operating instructions carefully to familiarize yourself with the features and modes of operation before using the instrument.

1 General information

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

OZW30. Central Unit SYNERGYR

Drayton Digistat +2RF

Stove Guard Kit User Manual

4.3-inch Back-Up Camera

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

40.3. Control Relays and Timers

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Quick start: Energy Switch EU

FPV MONITOR. User Manual

Duct Humidity Transmitter

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

GB/DAS User Instruction

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Heating Controller. Building Technologies HVAC Products

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

USER MANUAL MODEL

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Brochure EX

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

ABB i-bus KNX Fan Coil Controller FC/S 1.1

PD 100A. Printing data system

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Air conditioning, electrical testing

User Manual THR840DUK Digital Thermostat

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

EBDSPIR-PRM, EBDSPIR-PRM-IP

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Please refer to the chapters below for detailed information about all aspects of the products usage.

Mini Timer Owner's Manual. Model MT13A

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Electronic Control Devices The European Product Catalogue 2007

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Controls for fan coil units and cassettes

GSM HOME SECURITY SYSTEM

REMOTE CONTROL MANUAL

INSTALLER S & OWNER S MANUAL

Operation Guide 3M-22

Transcription:

Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD) o Joining of a digital thermostat with UFH-ZONE-R or UFH-EXTRAZONE -R Connection of an electrothermal motor UFH-ACT230NC2, UFH-ACT230NC4 or UFH- ACT24NC4 Connecting diagram Detailed information: o o o o UFH-THERM -R thermostat Technical characteristics LED indication Adjustment range limitation Calibration of the thermostat Digital thermostat (UFH-THERM -RD) Technical characteristics Connection of a floor sensor LCD display Installer s menu Description of the distinctive modes Timer/receiver: Characteristics LCD display Distinctive modes Setting-up of a user programme Installation menu Electrothermal motors UFH-ACT230NC2 UFH-ACT230NC4 UFH-ACT24NC2

UFH-ZONE-R This control unit enables you to receive signals from 6 radio-controlled room thermostats, by which all areas may be controlled. Besides, this module can also serve as timer for more (max. 10) non-programmable room thermostats. The programming of the timer and communication setting-up between sender and receiver proceeds in a very simple way. Control unit Timer and receiver Antenna As soon as 1 room thermostat detects a heat request, a built-in relay activates the pump and boiler. Extension possibility for 4 extra room thermostats, by using the optional extension module UFH- EXTRAZONE-R

Picture: UFH-ZONE-R Boiler and pump contact Supply voltage 230VAC or 24VAC Zone 1, 2, 3, 4, 5 and 6 Supply voltage 230VAC or 24VAC The unit has to be connected to the mains voltage (being 230VAC or 24VAC 50-60Hz). Because of electrocution danger, it is recommended not to do this until all thermostats and electrothermal motors have been connected. If you choose for a mains voltage of 24VAC, you can only connect electrothermal motors of the UFH- ACT24NC2 type to it. If you choose for a mains voltage of 230VAC, both types UFH-ACT230NC2 and UFH-ACT230NC4 can be connected. Zone 1, 2, 3, 4, 5 and 6: Each zone is provided with 2 pairs of terminals for the connection of electrothermal motors. Attention: only 2 motors maximally may be connected per pair (so: 4 motors per room thermostat). Boiler and pump contact: 2 pairs of dead terminals to control the boiler and pump. Attention: both contacts open and close at the same moment. Extension for extra zones: The control unit can be extended with an optional module UFH-EXTRAZONE-R. This module enables you to install 4 extra room thermostats and their accompanying electrothermal motors. The UFH-EXTRAZONE-R doesn t have to be separately provided with supply voltage. The supply voltage for the UFH-EXTRAZONE-R is provided by the UFH-ZONE-R.

Picture: UFH-EXTRAZONE-R: Connection between UFH-ZONE -R and UFH-EXTRAZONE -R: The black surfaces on the UFH-zone-R have to be linked with the forked terminals of the UFH- EXTRAZONE-R. This can be done by pushing the terminals through the white housing over the printed-circuit board. Because of electrocution danger, it is recommended to do this before connecting the UFH-ZONE-R to the mains supply. Attention: the UFH-EXTRAZONE -R has to be installed between the control unit and the timer/receiver. See picture below. Picture: UFH-ZONE -R and UFH-EXTRAZONE -R UFH-EXTRAZONE -R UFH-ZONE-R

Connection of a radio-controlled room thermostat (UFH-THERM -R): RF 1 1. Put the thermostatic switch in the centre position. 2. Put the timer - by using the < and > keys - in the comfort mode ( ) 3. Push the OK button then; keep pushing the OK while pushing the < at the same time. (You have reached the installer s menu now) 4. Push on - once now; you have reached the RF initialisation menu now. The utmost left LED is blinking. 5. By using the + and - keys, you can select and deselect respectively a zone. If you select a zone with the + key, the LED of the concerned zone keeps lighting up and the LED of the next zone starts blinking. If you deselect a zone with the - key, the LED of the concerned zone turns out and the LED of the next zone starts blinking. (You can select several zones for 1 room thermostat) 6. If you have selected the zones you want to connect with the room thermostat, put the thermostat switch in the comfort mode position. At this moment, a radio link is created between the thermostat and the receiver. On the LCD display of the timer, a double bar appears below and the LEDs of the selected zones turn out. 7. Repeat the above mentioned steps until you have connected all room thermostats with the desired zones. 8. Push on the OK key of the timer during 5 seconds now in order to leave the installer s menu. 9. Put the timer in the AUTO mode in order to activate the programmes.

How to connect a room thermostat: Open the thermostat: 1. Remove the temperature scale 2. Loosen the screw 3. Remove the front plate Place the thermostat in a suitable room: Place the thermostat at a height of 1.5 m Avoid direct sunlight Don t fix the thermostat on an external wall Closing of the thermostat 1. Place the front plate 2. Fasten the front plate with the screw 3. Replace the temperature scale as before

Connection of a radio-controlled digital room thermostat (UFH-THERM -D): o Put the timer in the comfort mode ( ) by using the < and > keys. o o Push the OK button then, keep pushing the OK while pushing the < at the same time. (You have reached the installer s menu now) Push - once now; you have reached the RF initialisation menu now. The utmost left LED blinks. o o o o By using the + and - keys you can select and deselect respectively a zone. If you select a zone with the + key, the LED of the concerned zone keeps lighting up and the LED of the next zone starts blinking. If you deselect a zone with the - key, the LED of the concerned zone turns out and the LED of the next zone starts blinking. (You can select several zones for 1 room thermostat). If you have selected the zones you want to connect with the room thermostat, push the OK key of the digital thermostat during 5 seconds. The UFH-THERM-RD is now sending radio signals to the timer. If a double bar appears at the bottom of the timer display, push again shortly on the OK key of the thermostat. The LEDs of the selected zones turn out now. Repeat the above mentioned steps until all room thermostats are connected with the desired zones. Push the OK key of the timer now during 5 seconds in order to leave the installer s menu. Put the timer in the AUTO mode in order to activate the programmes.

Open a thermostat: 1. Remove the white protecting cap 2. Loosen the screw 3. Remove the front plate Place the thermostat in a suitable room: Place the thermostat at a height of 1.5 m Avoid direct sunlight Don t fix the thermostat on an external wall Close the thermostat 1 Place the front plate 2 Fasten the front plate with the screw 3 Replace the white protecting cap as before

Connection of an electrothermal motor UFH-ACT230NC2, UFH-ACT230NC4 or UFH-ACT24NC2 Each zone is provided with 2 pairs of terminals for the connection of an electrothermal motor. Only 1 motor maximally may be connected per pair of terminals. So: 2 electrothermal motors per zone (or per room thermostat). In case of an electrothermal motor with auxiliary contact (UFH-230NC4), you only have to connect the blue and brown wire onto the terminals. Terminals for electrothermal motor

Connecting diagram: RF 1

Detailed information: UFH-THERM -R room thermostat This radio-controlled room thermostat has been especially created for floor heating systems. Each room thermostat has a personal digital code that excludes jamming from room thermostats in the neighbourhood. There is a switch at the side of the room thermostat by means of which the thermostat can be put into 3 modes, namely: - comfort - night reduction - OFF The thermostat has an LED indication, showing the heating-up phase and radio transmission. The temperature adjustment can be limited or blocked. Technical characteristics: Accuracy of the measured temperature: Adjustment range: Regulation: Autonomous feeding: Frequency: Protection class: Dimensions: 0.1 C + 5 C to 30 C Proportional link of 2 C for a cycle of 15 min. 2 batteries of 3V, type CR2430, life span 2 years 433.92MHz, <10mW IP30 80 x 80 x 31 mm LED indication: Green blinking: Red: Red blinking: Radio transmission Heating-up phase based on the environmental temperature The battery has to be replaced

Adjustment range limitation: Calibration of the thermostat:

UFH-THERM -RD Digital wireless room thermostat This radio-controlled room thermostat with LCD display has been especially created for floor heating systems. Each room thermostat has a personal digital code that excludes jamming from room thermostats in the neighbourhood. By pressing a key, the room thermostat can be easily put into 3 modes, namely: - comfort - night reduction - OFF Display of the desired temperature and room temperature. Can be equipped with an optional floor sensor (UFH-SENSOR) to limit the temperature of the floor. This room thermostat has also an extended installers menu. Following parameters can be adjusted: - Display of C or F - Selection between heating and cooling system - Adjustment of the time cycle (proportional regulation) - Regulation of the amplitude in C or F (proportional regulation) - Possibility to put the pump into operation once a day. - Option between environmental and floor temperature - Setting-up of the temperature limits of the floor sensor Technical characteristics: Accuracy of the measured temperature: Adjustment range: Autonomous feeding: Frequency: Protection class: Dimensions: 0.1 C + 5 C to 37 C, in steps of 0.5 C 2 batteries of 3V, type CR2430, life span 2 years 433.92MHz, <10mW IP30 80 x 80 x 31 mm Adjustment of the optional floor sensor: In order to prevent floor heating from being switched off by the thermostat when sunlight is coming in, or to prevent floor temperature from rising too much so that the comfortable feeling disappears, the room thermostats can be equipped with this optional floor sensor. Terminals for floor sensor Connect the sensor with the terminals provided for that purpose; the parameters of the floor sensor can be adjusted in the installer s menu (see installer s menu below).

LCD display: 1 : Function mode 2 : Burner into operation display 3 : Cooling system into operation display 4 : Replace the batteries (only for the RF model) 5 : When lighted up, 6 shows the environmental temperature 6 : Measured temperature or adjusted temperature 7 : Parameter installation: description Installer s menu: Push the OK button during 5 seconds, use the and keys then in order to select the parameter installation to be adapted. Push the OK button to walk through the parameters or to adapt the value. If the value blinks, you can modify it with and. Press the and key at the same time to return to the works settings. Push OK to confirm. N of the parameter Description of the parameter Rf Radio signal is sent out, press OK shortly to stop and leave the menu JO C/ F display J1 Cooling installation Cy Proportional integral regulation value time cycle in minutes (standard: 15 minutes) bp Proportional integral regulation value amplitude in degrees C/ F (standard: 2 C/3.6 F) J5 Select PMP to let operate the pump once a day (if the pump hasn t functioned one day) J6 Air: air temperature adjustment J7 reg (proportional integral) or HYs (0.3 K Hysteresis) to choose the regulation type Cp C/ F Display (standard: 2.0 C/3.6 F) Ao Adaptation environmental sensor display measured environmental value Fo Adaptation floor sensor display measured floor value FL Limitation of the floor temperature lower limit (standard 5 C/41 F); works only if the floor sensor has been connected. FH Limitation of the floor temperature upper limit (standard 28 C/82 F); works only if the floor sensor has been connected. Clr Push OK during 5 sec. in order to choose works settings for all parameters.

Description of distinctive modes: RF 1 Mode COMFORT Use this function to set your installation into comfort mode Use the and keys to adjust the comfort temperature The comfort temperature of the thermostat is unlimitedly maintained Afterwards, the environmental temperature is displayed again Mode REDUCED TEMPERATURE Use this function to put your installation into reduced temperature mode Use the and keys to adjust the reduced temperature The reduced temperature of the thermostat is unlimitedly maintained Afterwards, the environmental temperature is displayed again Mode OFF Use this function to switch off your heating installation. The display is empty now. (Attention: Your installation may freeze now). The parameters are kept. Timer Characteristics: Guarantees wireless communication, equipped with an active antenna. Average receiving range in residential environments: 50 m. 7 days, to be programmed separately per zone Provided with 9 works programmes and 12 user programmes (to be programmed yourself) Graphic programme rendition Temperature display in each zone Comfort mode / reduced temperature / frost protection Mode holidays Programming is maintained during long current interruptions The clock continues to operate during 3 hours of current interruption

Distinctive installation parameters LCD-display Holiday mode Temperature has been adapted manually Heat request Temperature use + / - to adapt temperature Environmental temperature MENU use to change mode Day of the week Time Graphic programme rendition Mode COMFORT: If selected, each zone follows the temperature which is adjusted on the local thermostat. If you push the OK button, you can read the temperature in the selected zone. Mode AUTOMATIC: If selected, the timer follows the programme which you programmed/selected for each zone. Sun = Room thermostat adjusted temperature. Moon = Room thermostat adjusted temperature - 4 C. REDUCED TEMPERATURE mode: If selected, the temperature is reduced in each zone. Room thermostat adjusted temperature - 4 C. FROST PROTECTION mode: If selected, the installation is frost-protected. With the +/- keys, you can adjust the anti-freeze temperature. In each zone, the temperature will be at least equal to the anti-freeze temperature.

Mode OFF: Select this mode if you want to turn off the heating installation. The timer will first of all turn off the installation and then itself. The clock continues to work another 3 hours; the programmes are kept in memory. The timer can be activated by pressing any random button. Attention: If you choose this mode, your installation may freeze. Mode CLOCK : Select this menu to adjust the time. use +/ - to set minutes, push on OK then use +/ - to set hours, push on OK then use +/ - to set the actual day (1 = Monday), push on OK then Mode PROGRAMMING: By pushing the +/- keys, the zone number starts blinking. (***) use +/ - to select a zone or a user programme with < and > you can look at the other days of the programme Programme number Shows the daily programme If you select a zone (1 to 12) and push on OK then, you can select a weekly programme that has to be followed by this zone. When the programme number is blinking: With < and > another day of the weekly programme is shown Use +/- to select a programme Shows the daily programme When you select a works programme (P1 to P9 (included)) or a user programme (U1 to U10 (included)) and then you push on OK, this programme will follow the AUTO mode.

Works programmes: P1: Morning, evening and in the weekend P2: Morning, noon, evening and in the weekend P3: Day and weekend P4: Evening and in the weekend P5: Morning, evening P6: Morning, afternoon and in the weekend P7: 7h-19h (office) P8: 8h-19h and Saturday (shop) P9: Weekend (weekend house) User programme setting-up: If you choose for a user menu (U1-U12) in (***), you can, after having pressed OK, program a whole week. Day Hour on cursor position With the + key, you select the comfort mode With the key, you select the reduced mode With the < and > you are walking through the programming bar; if a complete day is programmed, push the OK to go to the following day. If you push the OK button on the seventh day, this will bring you to the main menu. In phase (***), you can link your programme to the desired zone now. Installer s menu: Go with the < > keys to the comfort mode. Keep pushing on OK and press < at the same time. You have reached the installer s menu now. With +/- you can select the desired parameter; push OK to adapt the parameter. Parameters: F.0 PROG/EASY Select PROG for an extended menu Select EASY for a limited menu, only: - comfort - reduced temperature - frost protection - holiday mode F.1 BUZZ/no If you choose for BUZZ, a sound signal is generated when contact with a room thermostat is lost. F.2 NC/NO actuator Select NC if you use normally closed actuators

Select NO if you use normally open actuators RF 1 F.3 ACtU/no Actuator exercise Choose ACtU if you want to open the actuators during 5 minutes daily, if there is no heat request during 24 h. J.0 C/ F temperature display J.1 12h/24h time display J.2 --:15/--:8 time cycle in minutes Choose --:8 if you have an installation that thermally reacts slowly. J.3 2.0 K/1.2 K proportional link Choose 1.2 K only if you have an installation that thermally reacts quickly. J.5 PUMP/no pump test Choose PUMP in order to activate the pump during 2 minutes a day (at 12h), if there is no heat request during 24 h. J.6 ItCS/no Intelligent Temperature Control System Choose ItSC if you want to use intelligent software, taking into account the distinctive parameters, which are influencing the heating-up and cooling-down time of each zone. Consequently, each zone will be warmed up optimally with a minimum of energy costs. UFH-ACT230NC2 Electrothermal motor 230V, normally closed (NC) Attachment M30 x 1.5 Description: This electrothermal ON/OFF motor is used for automation of manifolds of type V-06 and VH-06. The motor is addressed by a room thermostat or regulation unit. Operation: The operation is based on a thermostatic wax element, which is activated by an electrical signal (230V) originating from a room thermostat or regulation unit. The wax element is warmed up by this electrical signal, which results in expansion. This expansion activates opening and closing of a zone. The motor is provided with a transparent zone which visualizes the status. (RED = valve closed, BLACK = valve opened) Technical characteristics: Supply voltage: 230V alternating voltage Frequency: 60Hertz Consumption: 2.5Watt Starter current: 0.25A x 0.5sec Initial opening and closing time: 90s Final opening and closing time: 3min. Protection class: IP44 Operating temperature: 0 to 50 C Storage temperature: -25 to 60 C Maximal liquid temperature: 110 C Nominal clamping force: 140N

UFH-ACT230NC4 Electrothermal motor 230V, normally closed (NC), with auxiliary contact. Attachment M30 x 1.5 Description: This electrothermal ON/OFF motor is used for automation of manifolds of type V-06 and VH-06. The motor is addressed by a room thermostat or regulation unit. The pump is addressed by an auxiliary contact. Operation: The operation is based on a thermostatic wax element, which is activated by an electrical signal (230V) originating from a room thermostat or regulation unit. The wax element is warmed up by this electrical signal, which results in expansion. This expansion activates opening and closing of a zone. The motor is provided with a transparent zone which visualizes the status. (RED = valve closed, BLACK = valve opened) Technical characteristics: Supply voltage: 230V alternating voltage Frequency: 60Hertz Consumption: 2.5Watt Starter current: 0.25A x 0.5sec Initial opening and closing time: 90s Final opening and closing time: 3min. Protection class: IP44 Operating temperature: 0 to 50 C Storage temperature: -25 to 60 C Maximal liquid temperature: 110 C Nominal clamping force: 140N Maximal switching current of the auxiliary contact: 700mA at 250 (AC) UFH-ACT24NC2 Electrothermal motor 24V, normally closed (NC) Attachment M30 x 1.5 Description: This electrothermal ON/OFF motor is used for automation of manifolds of type V-06 and VH-06. The motor is addressed by a room thermostat or regulation unit. Operation: The operation is based on a thermostatic wax element, which is activated by an electrical signal (24V) originating from a room thermostat or regulation unit. The wax element is warmed up by this electrical signal, which results in expansion. This expansion activates opening and closing of a zone. The motor is provided with a transparent zone which visualizes the status. (RED = valve closed, BLACK = valve opened) Technical characteristics: Supply voltage: 24V alternating voltage Frequency: 60Hertz Consumption: 2.5Watt Starter current: 0.25A x 0.5sec Initial opening and closing time: 90s Final opening and closing time: 3min. Protection class: IP44 Operating temperature: 0 to 50 C Storage temperature: -25 to 60 C Maximal liquid temperature: 110 C Nominal clamping force: 140N