CYMAQ Marking System AS200 + DS7050 N-14



Similar documents
BW-500 BED WEIGHER USER MANUAL

Hand-held marking system FlyMarker mini

HP ProDisplay P19A LED Backlit Monitor. User Guide

Hand-held thermometer Model CTH7000

MagIC Installation Manual. Point of Sales Terminals TD06014B

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Configuring the Siemens TC35 modems for use with the MI2292

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

HP Compaq LA1905wl, LA1905wg, LA2205wg, LA2205wl, LA22f, LA2405wg, and LA2405x LCD Monitors. User Guide

Operating instructions for Electrode sharpening machine WIG 4

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Espresso coffee grinder

Installation and Operation Back-UPS 1250, 1300, 1500

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

HP EliteDisplay LED Backlit Monitors. User Guide

Spetec Laminar Flow Systems. Operating Instructions

3500/93 System Display

Economy Combo Heat Press Manual Model No.: ECH-800

Pavilion IPS LED Backlit Monitors. User Guide

T Substation Maintenance and Commissioning Test Equipment

HP ProDisplay P17A LED Backlit Monitor. User Guide

ELECTRIC BICYCLE USER MANUAL

HP Compaq LE1902x, LE2002x, LE2002xm, and LE2202x LED Backlit LCD Monitors. User Guide

S.E.F.A Z.I PASTABRAC - B.P ESPERAZA FRANCE Tel :33 (0) Fax :33.(0) E Mail : contact@sefa.fr

WARNING CANADIAN D.O.C. WARNING

Back-UPS Pro 1300/1500 Installation and Operation

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

FORMULA Industrial Monitors

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

4.3-inch Back-Up Camera

FLEXIT S4 R S6 R S7 R

804 Ti Stand. Manual EN

Repeaters and Mimics Data Sheet

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

Operating Manual Electronic Wheelchair Scale with cable display M50610

Simple. Intelligent. The SIMATIC VS 100 Series. simatic MACHINE VISION.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Model: LCDM LCD Rear Vision Mirror Monitor Installation Manual Features

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

HP Z24i, Z27i, and Z30i IPS Displays. User Guide

Integra Padgett. Dermatomes. Limit uncertainty with quality and power from the brand you trust

Replacing the Gateway M675 Keyboard

Electro-pneumatic control valves

Ingenico. User Guide 5100M. Secure transaction and payment solutions

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

User Guide. ec7 e7p62 e7p122

Desktop Thermal Printer User s Manual

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

HP Compaq LA1956x, LA2006x, LA2206x, and LA2306x LED Backlit LCD Monitors. User Guide

TIG INVERTER INSTRUCTION MANUAL

T Zone Weekly Timer

Electronically Controlled Air Suspension (ECAS) for Trucks

Model UT713 OPERATING MANUAL

Model 349KLX Remote Display Digital Scale User Instructions

OPL BASIC. Dosing System for Professional Laundry machines. Contents

DAB+ / FM Tuner Model: TU-201

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

RM7000 TC with Internal Pulser

TX OPEN RS232/485 module

Drayton Digistat +2RF/+3RF

CONSOLE REMOTE I /O AC 9V

LCD Drawer User Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

DC Electronic Loads 8500 series

Periodic Verification System Model 775PVS

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

BM-Dustdetector. Operation Manual

CMP30. User Manual.

Senses SV series industrial monitor user manual

MANUAL PC1000R

Nintendo 3DS XL Quick-Start Guide

PS 155 WIRELESS INTERCOM USER MANUAL

MADRIX NEO Quick Start Guide & User Manual

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

3. Standards: Comply with ISO, BS, ASTM, JIS standard and so on.

MultiDim MKII V.2 ORDERCODE 50386

MICRO WELDER INSTRUCTION MANUAL

LEEB HARDNESS TESTER TH130/132/134

Portable Hardness Tester

Operating Manual Please Read Before Operating Unit

V94 BULK TAPE DEGAUSSER

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

PS/2 KVM Console Extender User Manual (GCE250)

Transcription:

CYMAQ Marking System AS200 + DS7050 N-14 Serial Number: 13716 CYMAQ www.cymaq.com

INDEX 1. PRESENTATION AND GENERAL POINTS 1.1. General Points 1.2. Identification plate 2. MACHINE CHARACTERISTICS 2.1. Main elements 3. INSTALLING THE MACHINE 3.1. Unpacking the machine 3.2. Installation 3.3. Air Filter (for pneumatic marking head) 4. MARKING EXAMPLE 5. TROUBLESHOOTING 6. ELECTRICAL DIAGRAMM 7. TECHNICAL DATA

1. PRESENTATION AND GENERAL POINTS 1.1 General Points CYMAQ marking machine has been designed taking current EEC safety regulations into account. Although the installation of the machine is straightforward, we recommend that you should not try to install, adjust, or operate it without first reading this manual. Follow the steps below to ensure the machine functions correctly and optimally: Observe and follow the procedures indicated on the machine. Always use original CYMAQ recommended spare parts. Any use other than that stated in his manual will automatically result in the customer waiving all their rights to compensation from CYMAQ, and will not be considered under the terms and conditions of the warranty. Furthermore, the incorrect use of the machine may endanger the operator and other people. CYMAQ marking machine conforms to European community norms: Machines Directive, Low voltage, Electromagnetic compatibility. CYMAQ marking machine is an electrically or pneumatically driven dot peen marking machine which marks microdots at an adjustable impact force. Characters and logos can be marked with different sizes and depth. Marking can be done on all sorts of materials (metal, plastic, etc.) and flat or curved pieces. A CYMAQ marking machine has following units: 1) Marking head: this is the mechanic part. The stylus can be activated electrically or pneumatically and the movement is done by two belt-driven axes. 2) Control Unit: the electronic control box to edit and mark the data. 3) START/STOP pushbutton: to start, pause or end the marking process.

1.2 Identification plate CYMAQ marking machine has the following identification plate, which specifies the serial number, name of the manufacturer, EC mark, marking head and electronic control unit model and the year of manufacture. Identification Plate for the Marking Head Year MADE IN SPAIN Marking Head Serial Number Identification Plate for the Electronic Control Unit 04 MADE IN SPAIN Year Control Unit Serial Number

2. MACHINE CHARACTERISTICS 2.1 Main elements Front side AS200 CONTROL UNIT 2 1 3 4 1. Membrane Keyboard 2. Graphic display 3. Fields / Values keys 4. Position and displacement keys Rear side: 5 6 5. On/Off switch and Power Supply 6. Power Supply tag information 7. AUTOMAT connector 8. MAN connector 9. Fuse F1: T6,3A (Solenoid) 7 8 9 10 11 12 13 10. Fuse F2: T4A (Motor) 11. MARK connector 12. Keyboard connector 13. RS232 connector 14. Display contrast dial 14

DS7050 MARKING HEAD 2 3 4 5 1 6 1. Punch head 2. Micrometer 3. MARK cable 4. Air input (6 Bar) (ø6) 5. MARK cable 6. Marking area: 70 x 50 mm.

3. INSTALLING THE MACHINE 3.1 Unpacking the machine The machine is packed inside a box. Dimensions and weight of the machine plus packaging depends on the type of marking machine. When unpacking the machine, inspect it carefully for any damage caused during transit. If you find damage, notify the carrier immediately and do not touch the machine until the carrier s agent has carried out the corresponding inspection. When unpacking the box make sure the following accessories are inside along with the machine (Marking head + Control unit): 1. Power supply cable + ferrite 2. Set of fuses 3. Start/Stop pushbutton 4. CD Manual 5. CE community norms conformity s sheet 6. Air filter/regulator + Lubricator (Only for pneumatic marking head) 3.2 Installation The machine is assembled, calibrated and checked in the factory of PYFE S.A. To ensure the machine operates correctly position the marking machine on a flat, stable surface able to resist the weight of the machine. Make sure there is enough space around the machine for the operator to work in comfortably. Before switching the machine on for the first time you have to do following checks: Connect the cable of the marking head to the MARK connector on the unit control box. Connect the START/STOP buttons to the MAN connector on the unit control box. Connect the machine to the main supply by a plug with an earth wire and a differential switch. The supply voltage has to be according to the data on the identification plate on the rear side of the control unit. It is essential that the electrical system at the premises is connected to earth and is also fitted with a differential safety device. Make sure the machine is connected to earth. Switch the machine on with the switch on the rear side of the controller. After switching the machine on an internal test is conducted to check the marking head. A few seconds later control unit displays the main menu. Adjust the screen contrast by turning the CTR dial at the rear side of the control unit. Marking: the stylus does not represent any direct risk to hands or arms. However, the marking area should always be cleared before pressing the mark button.

3.3 Air filter/regulator + Lubricator (for pneumatic marking head) The filter/regulator unit controls air pressure to the marking head. Recommended oil viscosity: Oil clase1 (ISO VG32) Oil Quantity: minimum 1 cm 3

4. MARKING EXAMPLE This is an example to run a marking test by editing and marking a file. AS200 1. Swicht machine on 2. Display shows main menu 3. Use the direction keys (up, down, left, right) to go to Edit menu. 4. Press Enter and a window will appear to enter a file name. 5. After enter a file name press Enter key. Edit menu will be show and you can now introduce some text to be marked. I.e., 1234. 6. Press START button to mark a piece. 7. The file can be saved into memory and can be marked from MARK menu (see AS200 s Instructions manual)

5. TROUBLESHOOTING The machine does not switch on: Check that the machine is connected to the main power supply and that the fuses are ok (T2A fuses). After power the machine message Failure in motors X or Y or Connect START/STOP button appears: Turn off power, check all connections on rear of the controller. The machine switches on but the head does not move: Check that the fuses are ok. Display screen is dark: Adjust display at rear of controller The external keyboard does not work or the button functions have changed: Check that the keyboard is properly connected at the rear of the machine. The marking is misaligned or deformed: Check the belts and tighten them if necessary.

6. ELECTRICAL DIAGRAMM AUTOMAT-MAN connector MARK connector KEYBOARD connector RS232 connector

7. Technical data Main supply Battery: Stylus: Head: Marking speed: Marking force: Movements: 220 V / 110 V / 100 V 50 60 Hz Lithium battery 3V CR2032 (AS200) Tungsten carbide Electronic or pneumatic drive Variable speed depending on the marking head Variable force in electronic head and variable piston timings in pneumatic head Two belt-driven axes Maximum marking area: Differential marking head: 70mm x 50mm Display: Keyboard: Memory: Dimensions: Control Unit AS200: LCD de 56mm x 38mm Standard Up to 126 text files of 20 lines with 20 characters Up to 96 logos via RS232 Length (mm) Height (mm) Width (mm) AS200 345 145 260 DS7050 150 112 135 Weight: Connectors: AS200 DS7050 Description Marking Head START / STOP button Keyboard Serial Port RS 232C 7,2 Kg 2,9 Kg Connector MARK 25 pins Sub-D female MAN 9 pins Sub-D male Mini-DIN RS232 9 pins Sub-D female