Emergency Lighting Practices in the UAE. Richard Caple MSc MSLL Lighting Applications Manager SLL Vice President



Similar documents
A Guide To BS5266. The design, installation and wiring of emergency lighting systems

EMERGENCY LIGHTING DESIGN GUIDE

EMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE

Emergency Lighting Guide

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

How To Write A Fire Risk Assessment

Robust and waterproof

ELECTRICIAN S GUIDE TO EMERGENCY LIGHTING. Fully updated to BS :2011. electrician s guide

Guidance for Electrical Contractors on Emergency Lighting Legislation

BS5839 Part 1:2002 Overview

SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

LG9: Lighting Guide 9 Lighting for Communal Residential Buildings

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Emergency Voice Communication Systems

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

GENERAL FIRE SAFETY TERMS & DEFINITIONS

FIRE SAFETY RECORD OF TESTS LOGBOOK

UPP Residential Services Fire Risk Assessment

The Impact of the new Directive 2014/33/EU and Standard EN81-20 on New Lifts

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK

I.S :2013 Fire Detection & Alarm Systems

FIRE SAFETY PRECAUTIONS

Fire. The Fire Installers Mate. A guide to fire alarm systems design

EMERGENCY LIGHTING AND CONTROL

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

I.S :2013 Fire Detection & Alarm Systems

Fire Log Book. Provided by Norfolk Fire & Rescue Service. Name and address of premises:...

Fire Risk Assessment for

ACCESS AUDIT OF WESTPORT HOUSE

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard for Emergency Power Systems.

FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book:

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Appraisal of Passive and Active Fire Protection Systems in Student s Accommodation

Fire Safety Log Book

RESIDENTS FIRE SAFETY INFORMATION PACK

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

Lighting Requirements

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Additional Guidance. for application to. HM Government Guide to Fire Safety Risk Assessment Residential Care Premises

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

Standard the the Raising

Fire Safety Risk Assessment

Guidance Document on Fire Safety Signs and Notices FIA Guidance for the Fire Protection Industry

FIRE RISK ASSESSMENT

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

Fire Risk Assessment Safety Checklist

Panic & emergency exit devices

- 5 - Table1. Maximum Compartment Volumes

Fire Safety In High Rise Building

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Marquee Building Consents & Fire Safety Guidelines

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

Fire Safety logbook

Workplace Safety Inspections Adopt a systematic approach by inspecting 8 areas of safety:

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Safety Systems Review Facilities Management Guidance and specification Version

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

SBR FIRE RISK ASSESSMENT

DOSSIER EN m CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012

Guide to Fire Alarm Systems

Fire Alarm system Installation Guide

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

FIRE RISK ASSESSMENT

NY Fire Safety Institute

Linear. Emergency Operation for Linear Fluorescent Lamp Fixtures The Philips Bodine Linear Fluorescent Emergency Ballasts

Greater Manchester Fire and Rescue Service

NEW Practical Courses for the Electrical Industry

EVACUATION OF DISABLED PEOPLE (Document under constant review)

Fire precautions in dwellings. Private sector housing Providing homes building communities

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

2007 ICC FINAL ACTION AGENDA

Fire safety advice for landlords

Fire Risk Assessment. John Revington

Guidance on Provision of Fire Wardens

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

ACCESSIBILITY STANDARD

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

9452/9453 Installation and User Guide

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Current as of 11/10/08 1 of 1

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

D200+ Auto-Dialler Installation/Operators Manual

Emergency Evacuation Plan: 232 King St.

INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES

FIRE ESCAPE SIGNS Guidance on compliance

PLAN REVIEW GUIDE FOR FIRE ALARM

Transcription:

Emergency Lighting Practices in the UAE Richard Caple MSc MSLL Lighting Applications Manager SLL Vice President

Agenda UAE emergency lighting requirements Emergency systems and luminaires Emergency lighting design Approved products

Emergency Lighting Requirements UAE Fire & Life Safety Code of Practice Chapter 6 - Emergency and Exit lighting requirements Mixture of British, European and American standards Emergency lighting products require Civil Defence approval

Emergency Lighting Requirements Technically known as Escape Lighting To facilitate safe exit from the building when the normal lighting fails To allow potentially dangerous equipment to be made safe before evacuation To enable Fire Wardens & Fire and Rescue Service to search the building & locate missing people

Emergency Lighting Requirements Emergency lighting must:- Indicate clearly and unambiguously the escape routes Provide illumination along such routes to allow safe movement towards and through the exits provided Ensure that fire alarm call points and fire fighting equipment provided along the escape routes can be readily located Permit operations concerned with safety measures Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements Emergency Lighting Escape Lighting Standby Lighting

Emergency Lighting Requirements Standby Lighting Providing full output if mains fails

Emergency Lighting Requirements Emergency Lighting Escape Lighting Standby Lighting Escape Route Open Area High Risk Area

Emergency Lighting Requirements Escape Route Lighting Applies to corridors, lobbies and staircases Illumination level: 10.8 lux average, 1.1 lux minimum Uniformity (max:min)= 40:1 Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements Open Area Lighting >60m2 or as determined by Risk Assessment Illumination Level: 10.8 lux average, 1.1 lux minimum Uniformity (max:min) = 40:1 Exclude 0.5m border around perimeter of area Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements High Risk Lighting Safe termination of hazardous activity Safe passage / rescue access Illumination level: 10.8 lux minimum Applies to all areas where high risks have been identified within a risk assessment, these may include:- Kitchens Plant rooms Areas of refuge First aid rooms Fire control equipment rooms etc Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements Points of Emphasis Stairs so that each flight receives direct light Changes in level Changes of escape route direction Corridor intersections First aid posts Fire alarm call points or pieces of fire fighting equipment External areas in the immediate vicinity of final exits Moving stairways and walkways Motor generator, control and plant rooms Lift cars Covered car parks Areas of refuge Toilet facilities exceeding 8m² or any multiple closet facility without borrowed light All other areas as deemed by the Risk Assessment Source: UAE Fire & Life Safety Code of Practice/BSEN5266

Emergency Lighting Requirements 3 hrs Emergency lighting must be provided for 3 hours

Emergency Lighting Requirements 1.5 hrs Emergency lighting levels should not fall below 60% of the target level (6.5 lux ave / 0.65 lux min) after 1.5 hrs of operation.

Emergency Lighting Requirements Hotel rooms or suites need to be covered

Emergency Lighting Requirements Buildings where many people maybe in attendance

Emergency Lighting Requirements Emergency luminaires should be feed from the local lighting circuit Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements Testing of Emergency Luminaires Emergency luminaires shall be automatically monitored and tested through a dedicated control system. The control system shall be interfaced with the BMS and fire alarm control Source: UAE Fire & Life Safety Code of Practice

Emergency Lighting Requirements Exit Signage

Emergency Lighting Requirements Exit Signage Required to ensure ESCAPE ROUTES are apparent from any location Should be conspicuous Consider smoke accumulation

Emergency Lighting Requirements Exit Signage Externally Lit Viewing Distance = 100 x Sign Height = 15m (150mm tall sign) Internally Lit Viewing Distance = 200 x Sign Height = 30m (150mm tall sign) Source: BS5266-7/EN1838

Emergency Lighting Requirements Clear and unambiguous instructions! Which way?

Agenda UAE emergency lighting requirements Emergency systems and luminaires Emergency lighting design Approved products

Emergency Systems and Luminaires Stand Alone system Central Battery system Easier to install Higher illumination values Greater flexibility Maintenance costs are spread over time Longer battery life (Maintenance required) Luminaires do not need conversion Can be difficult to achieve higher emergency light levels Increased wiring complexity/cost Needs daily inspection Fixed capacity Higher battery replacement costs

Emergency Lighting Requirements Stand alone systems shall:- Provide 3 hour duration Be connected an automatic monitoring and testing system The control system shall monitor the luminaires for:- Low battery Faults Status Source: BS5266-7/EN1838

Emergency Lighting Requirements Central battery systems shall:- Provide 3 hour duration Be connected to an automatic monitoring and testing system Provide a cross zoning arrangement where at least two circuits shall cover each area in a overlapping of light units Source: BS5266-7/EN1838

Emergency Systems and Luminaires Non-maintained Normal mode off Switches ON when mains fails Maintained Normal mode permanently on or switched Switches to battery when mains fails Sustained Normal lamp is switched Emergency lamp switches ON when mains fails

Emergency Systems and Luminaires Product suitability Aesthetics of stand alone emergency products often undesirable

Emergency Systems and Luminaires Product suitability LED technology has allowed emergency lighting to become more discrete Enhanced performance over traditional light sources Longer life/less maintenance

Emergency Systems and Luminaires Product suitability Lens technology to optimise light distribution Efficiency - 3W LED @ 1000mA = 280 lumen output Long Life - typically >50,000 hours Small form factor - just 50mm Ø

Emergency Systems and Luminaires

Emergency Systems and Luminaires Exit signage 50,000 hr 4w LED strip vs. 4,000 hr T5 8w fluorescent

Emergency Systems and Luminaires Inspection & testing Daily Central battery cabinets only Visual inspection to ensure the system is in a ready condition Monthly Short duration test To ensure that all emergency luminaires illuminate correctly (lamps and batteries are working) Annually Full duration test To ensure that all emergency luminaires illuminate correctly and fully achieve duration required (3 hours)

Emergency Systems and Luminaires Inspection & testing Automatic testing systems

Agenda UAE emergency lighting requirements Emergency systems and luminaires Emergency lighting design Approved products

Emergency Lighting Design Design process Identify the type of building Identify exits, final exits and safe areas Identify escape routes Identify open plan areas >60m² Identify hazardous areas Identify points of emphasis Select emergency lighting products Position luminaires at points of emphasis and add extra fitting is until lighting levels are reached Check glare and uniformity Other design considerations Height & position of calculation plane Reflectance s of room Maintenance factors

Emergency Lighting Design Luminaire spacing tables Lighting software can provide spacing table information

Emergency Lighting Design Avoiding glare BSEN 1838

Emergency Lighting Design Avoiding glare EXIT EXIT

Emergency Lighting Design Minimum 2 luminaires per compartment BSEN 50172

Agenda UAE emergency lighting requirements Emergency systems and luminaires Emergency lighting design Approved products

Approved Products All life safety, fire safety and emergency services shall be listed, approved and registered by the Civil Defence Ministry

Approved Products Requirements from the UK perspective Civil Defence approval certificate

Approved Products

Approved Products Certificate of Compliance Kitemark certification

Approved Products Civil Defence Approved Products DCD Dubai Approved QCD Qatar Approved ADCD Abu Dhabi Approved