INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX



Similar documents
Installation Instructions

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Installer s Guide 18-AH39D1-13

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Installation Instructions

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

INSTALLATION INSTRUCTIONS

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

COMPRESSOR REPLACEMENT PROCEDURE

Your safety and the safety of others are very important.

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

How To Install An Evaporator Coil

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

DESIGN STANDARDS SECTION

Evaporator Coil. Installation Instructions GENERAL

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

CARING FOR YOUR WATER HEATER

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

INSTALLATION INSTRUCTIONS

Ductless Split Air Conditioner

COMPRESSOR REPLACEMENT PROCEDURE

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Refrigeration System Installation & Operation Manual

IMPORTANT SAFETY NOTICE

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.


SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Packaged Terminal Air Conditioner Wall Sleeve Installation

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Cooling system components, removing and installing

SSB*H4. Service Literature. SSB*H4 Commercial Air Conditioner

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4AC16LT SERIES. Split System Air Conditioner. Save these instructions for future reference WARNING

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

4AC13/14 SPLIT SYSTEM AIR CONDITIONER INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

15GAL STEEL OIL DRAIN WITH 110V PUMP

Elements Elements describe the essential outcomes.

Portable Air Conditioner

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Air Conditioning System

Refrigeration Installation 101

INSTALLATION INSTRUCTIONS

AIR CONDITIONER INSTALLATION MANUAL

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Central Air Conditioner

INSTALLATION INSTRUCTION

Evaporator Coil Installation Instructions

2. AIRCONDITIONING AND REFRIGERATION

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

4AC13/14 SPLIT SYSTEM AIR CONDITIONER INSTALLATION / STARTUP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

REMOVAL AND INSTALLATION

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Installation Instructions

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Evaluate, Clean, and Tune Guidance

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

REPAIR PARTS. Room Air Conditioner Heat and Heat Pump Units

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

Oil and Coolant Circulating Heating System. Model - OCSM

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Test Code: 8297 / Version 1

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

SYSTEM Inverter Air Conditioners

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

PORTABLE AIR CONDITIONER

Cased/Uncased Coils For Gas And Oil Furnaces

CEILING CASSETTE FAN COIL UNIT

Installation Instructions

Why and How we Use Capacity Control

Transcription:

Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into fan coils (see Figure 1) The kit is designed to allow easy replacement of existing slope or A coils. A 3/4 to 5/8 inch reducing bushing is included in the coil kit for use on the field vapor connection tube, when necessary. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety alert symbol! When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than one disconnect switch. Lock out and tag switch with a suitable warning label.! CAUTION PROPERTY DAMAGE HAZARD Failure to follow this caution may result in property damage R 410A systems operate at higher pressures than R 22 systems. When working with R 410A systems, use only service equipment and replacement components specifically rated or approved for R 410A service.! WARNING ELECTRICAL SHOCK HAZARD Failure to turn off electric power could result in personal injury or death. Before installing or servicing system, turn off main power to the system. There may be more than one disconnect switch, including accessory heater(s). 484 01 5100 00 March 2009

DESCRIPTION AND USAGE Figure 1 Typical Fan Coil The replacement coil kit is designed for use when replacement of an existing slope of A coil is required. NOTE: Replacement of an indoor slope or A coil must include recovery and recycling of refrigerant currently in the system. Provided the refrigerant has not been contaminated with moisture, acid, solid particulate, or non condensibles, it may be recovered by following the procedures listed below. However, if the refrigerant is contaminated, recycling or reclaiming methods are required. If leaks are present in the system, meaning the refrigerant may be contaminated, recycling or reclaiming methods MUST be used. Installation of new filter drier(s) is required. The filter drier type will depend up on the contaminants in the system. See Split System Residential Air Conditioners and Heat Pumps Service manuals for further information.! CAUTION PROPERTY DAMAGE HAZARD Failure to follow this caution may result in personal injury or property damage Relieve pressure and recover all refrigerant before system repair or final unit disposal to avoid personal injury. Use all service ports and open all flow control devices including the solenoid valves. INSTALLATION If it is determined that the system does not have leaks, and the refrigerant is not contaminated, proceed as follows: 1. Recover system refrigerant a. Attach gage/manifold set to service valves. b. Start unit in cooling mode. c. Front seat (close) liquid line service valve. d. Operate unit until vapor pressure reaches 5 psig (35kPa), or until suction line LPS opens. e. Turn off electrical supply to outdoor unit. f. Front seat (close) vapor service valve. g. Recover any remaining refrigerant. NOTE: All condenser coils hold only a factory supplied amount of refrigerant. Excess refrigerant, such as in long line applications, may cause compressor internal pressure relief valve to open (indicated by sudden rise in vapor pressure) before refrigerant is recovered. If this occurs, turn off electrical supply to outdoor unit immediately, front seat (close) vapor service valve, and recover any remaining refrigerant. 2. Turn off electrical supply to indoor unit. 3. Disconnect condensate drain line.! WARNING FIRE HAZARD Failure to follow this warning could result in personal injury or death. Use of torch may cause oil to catch fire. To remove use tubing cutter only. 4. Disconnect liquid and vapor lines from indoor coil. Use a tubing cutter to cut the lines. 5. Remove coil access panel. 6. Remove clip securing fitting panel to condensate drain pan and remove fitting panel. 7. Remove all shipping clips (if present), including horizontal pan clip. Slide coil and condensate pan assembly out of unit. 8. Remove horizontal condensate drain pan from coil (if present) and condensate pan assembly. (See Fig. 2.) 9. Remove 4 coil brackets if present. (See Fig. 2.) 10. Remove screws at delta plates and remove coil from vertical condensate drain pan. (See Fig. 2.) 2 484 01 5100 00

11. Thermostatic Expansion Valve (TXV) units only To use original TXV with new coil, remove TXV from original coil and install onto new coil as follows: a. If TXV has a sweat joint on the valve outlet, unbraze sweat joint as shown in Fig. 3. tube from new coil, and remove piston from piston body. Use tubing cutters to cut off elbow. (See Fig. 4.) (3.) Braze remaining tube and nut onto TXV outlet. (See Fig. 5.) (4.) Install resulting TXV/nut assembly onto new coil in same location as on old coil. (5.) Install equalizer tube onto new coil by scoring tube to extension tube. (See Fig. 6.) (6.) Install thermal bulb into suction header of new coil in b. If valve has a mechanical joint at valve outlet, use wrenches to separate valve outlet from old coil. tube from new coil using wrenches. Remove piston. Install valve onto new coil using wrenches. If TXV outlet is flare type, use adapter tube provided. (3.) Install equalizer tube onto new coil by scoring tube to extension tube. (4.) Install thermal bulb into suction header of new coil in c. If replacement coil has a mechanical connection with no piston body, install TXV to flare nut or new coil. off tube at old suction header, or braze. Remove bulb from old coil. (2.) Install TXV onto new coil. Install valve onto new coil onto coil using wrenches. (3.) Install equalizer tube onto new coil by scoring and breaking extension tube near brazed tip of tube. Slide equalizer tube into extension tube and braze connection. (4.) Install thermal bulb onto suction header of new coil in 12. Horizontal Applications Only Remove coil top seal (attached with 4 screws) and J shaped tube from original coil, and install them in same position on new coil. (See Fig. 2.) 13. Place coil assembly in plastic condensate pan and secure with 4 screws through delta plate. (See Fig. 2.) 14. Horizontal and Upflow Applications Only Attach 4 coil brackets to coil and pan assembly. (See Fig. 2.) 15. Horizontal Applications Only Place horizontal condensate pan into position on coil and pan assembly. NOTE: Installation of horizontal condensate pan is not necessary for upflow or downflow applications. 16. Slide completed assembly into unit. 17. Reinstall fitting panel and reconnect clip securing fitting panel to condensate drain pan. 18. Horizontal Applications Only Reinstall horizontal pan clip and secure with 1 screw. (See Fig. 2.) 19. Reinstall coil access panel. 20. Reconnect liquid and vapor refrigerant lines and condensate drain line. Install new filter drier(s). NOTE: If a torch is used to unbraze the line set, protect the fitting panel with a wet cloth or braze shield as necessary. 21. Evacuate line set and indoor coil to 500 microns, back seat (open) liquid and vapor service valves. 22. Turn on electrical supplies to indoor and outdoor units. 23. Check system refrigerant charge and operation. See Split System Residential Air Conditioners and Heat Pump Service Manuals for further information.! CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage When securing braces or supports to unit, select a location where drill and fasteners will not contact refrigeration components. 484 01 5100 00 3

Figure 2 HORIZONTAL CONDENSTATE PAN HORIZONTAL PAN CLIP A Coil Component Location EXPANSION DEVICE (TXV SHOWN) COIL TOP SEAL DELTA PLATE Figure 4 Modification required for sweat outlet TXV LIQUID LINE FITTING TUBE BRAZE REMAINING TUBE INTO OUTLET OF TXV CUT LINE FOR USE WITH SWEAT OUTLET TXV S COIL BRACKET (4 PER UNIT) SCREWS DELTA PLATE TO PAN (4 PER UNIT) VERTICAL CONDENSATE PAN A90268 ELBOW A93562 Figure 3 Removal of Internal TXV with sweat outlet joint Figure 5 Installation of Original sweat outlet TXV onto Replacement Coil BREAK BRAZE JOINT BRAZE JOINT REMAINING TUBE A90277 4 484 01 5100 00 A93563

INSTALLATION SLOPE COIL UNITS ONLY 1. Recover system refrigerant. a. Attach gage/manifold set to service valves. b. Start unit in cooling mode. c. Front seat (close) liquid line service valve. d. Operate unit until vapor pressure reaches 5 psig (35kPa), or until suction line LPS opens. e. Turn off electrical supply to outdoor unit. f. Front seat (close) vapor service valve. g. Recover any remaining refrigerant. NOTE: All condenser coils hold only a factory supplied amount of refrigerant. Excess refrigerant, such as in long line applications, may cause compressor internal pressure relief valve to open (indicated by sudden rise in vapor pressure) before refrigerant is recovered. If this occurs, turn off electrical supply to outdoor unit immediately, front seat (close) vapor service valve, and recover any remaining refrigerant. 2. Turn off electrical supply to indoor unit. 3. Disconnect condensate drain line. 4. Disconnect liquid and vapor lines from indoor coil. Use a tubing cutter to cut the lines. 5. Remove coil access and fitting panels. 6. Remove 1 screw securing coil to unit casing. 7. Remove coil/pan assembly from unit. 8. Place assembly on a flat surface. On units manufactured prior to 1996, remove 2 screws securing coil support columns to pan. (See Fig. 7.) 9. Rotate columns 90, pull away from coil, and remove columns from assembly. 10. Remove 2 screws securing coil to condensate pan. (See Fig. 7 and 8.) 11. Remove coil from condensate pan. 12. Thermostatic Expansion Valve (TXV) units only To use original TXV with new coil, remove TXV from original coil and install onto new coil, as follows: a. If TXV has a sweat joint on the valve outlet, unbraze sweat joint as shown in Fig. 3. tube from new coil, and remove piston from piston body. Use tubing cutters, cut off elbow. (See Fig. 4.) (3.) Braze remaining tube and nut onto TXV outlet. (See Fig. 5.) (4.) Install resulting TXV/nut assembly onto new coil in same location as on old coil. (5.) Install equalizer tube onto new coil by scoring tube to extension tube. (See Fig. 6.) (6.) Install thermal bulb into suction header of new coil in b. If valve has a mechanical joint at valve outlet, use wrenches to separate valve outlet from old coil. tube from new coil using wrenches. Remove piston. Install valve onto new coil using wrenches. If TXV outlet is flare type, use adapter tube provided. (3.) Install equalizer tube onto new coil by scoring tube to extension tube. (4.) Install thermal bulb into suction header of new coil in c. If replacement coil has a mechanical connection with no piston body, install TXV to flare nut on new coil. off tube at old suction header, or unbraze. Remove bulb from old coil. (2.) Install TXV onto new coil. Install valve onto new coil onto coil using wrenches. (3.) Install equalizer tube onto new coil by scoring and breaking extension tube near brazed tip of tube. Slide equalizer tube into extension tube and braze connection. (4.) Install thermal bulb onto suction header of new coil in 13. Install new coil into condensate pan using two original screws and two support columns. 14. Install new coil pan assembly into unit and secure with one screw previously removed from unit casing. (See Fig.7.) 15. Reinstall coil access panel. 16. Reconnect liquid and vapor refrigerant lines and condensate drain line. Install new filter drier(s). NOTE: If a torch is used to unbraze the line set, protect the fitting panel with a wet cloth or braze shield as necessary. 17. Evacuate line set and indoor coil to 500 microns, back seat (open) liquid and vapor service valves. 18. Turn on electrical supplies to indoor and outdoor units. 19. Check system refrigerant charge and operation. See Split System Residential Air Conditioners and Heat Pump Service Manuals for further information. 484 01 5100 00 5

Figure 6 Replacement A Coil Figure 7 Slope Coil Component Location DISTRIBUTOR COIL SUPPORT COLUMN COIL TOP SEAL (PARTIALLY HIDDEN) COIL TO CASING SCREW DISTRIBUTOR TUBE COLUMN SCREW CONDENSATE PAN LIQUID TUBE FIELD CONNECTION FLARE NUT TUBE CLAMP EXTENSION TUBE A98008 A90276 Figure 8 Slope Coil Component Location COIL MOUNTING SCREW BLOWER ASSEMBLY RAIL SLOPE COIL SKI DRAINPAN REFRIGERANT CONNECTIONS COIL TO PAN SCREW (BOTH SIDES) A98007 6 484 01 5100 00

R 410A QUICK REFERENCE GUIDE R 410A refrigerant operates at 50% 70% higher pressures than R 22. Be sure that servicing equipment and replacement components are designed to operate with R 410A. R 410A refrigerant cylinders are rose colored. Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400. R 410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose. Manifold sets should be 750 psig high side and 200 psig low side with 520 psig low side retard. Use hoses with 750 psig service pressure rating. Leak detectors should be designed to detect HFC refrigerant. R 410A, as with other HFC refrigerants, is only compatible with POE oils. POE oils absorb moisture rapidly. Do not expose oil to atmosphere. POE oils may cause damage to certain plastics and roofing materials. Vacuum pumps will not remove moisture from oil. A liquid line filter drier is required on every unit. Do not use liquid line filter driers with rated working pressures less than 600 psig. Do not install a suction line filter drier in liquid line. Wrap all filter driers and service valves with wet cloth when brazing. Do not use with an R 22 TXV. If indoor unit is equipped with an R 22 TXV, it must be changed to an R 410A TXV. Do not use capillary tube indoor coils. Never open system to atmosphere while it is under a vacuum. When system must be opened for service, break vacuum with dry nitrogen and replace all filter driers. Do not vent R 410A into the atmosphere. Observe all WARNINGS, CAUTIONS, NOTES, and bold text. International Comfort Products, LLC Lewisburg, TN 37091 U.S.A. 484 01 5100 00 7