www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

Similar documents
SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Arc Fault Circuit Interrupters Frequently Asked Questions

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Mini Power-Zone Unit Substation

For Models #6-5001, #6-7501, # & #10-12K1

Top Commercial / Residential Electrical Requirements *

65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH

8146/5 Series Breaker Panelboards

Siemens STEP 2000 Course Basics of Electrical Products

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

The Ultimate Load Center Features INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

Applications. Remote Display Mounting Kits

Protect your home and family with Advanced Technology from Cutler-Hammer

GENERAL ELECTRICAL REQUIREMENTS

Electrical Grounding. Appendix C

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Continuous Power... Continuous Protection

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Equipment. Metering. Metering Equipment 1. Contents

Electrical Code Regulation

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

ASCO SERIES 185 Power Transfer Switches

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Introduction. Upon completion of Basics of Electrical Products, you should be able to:

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

INSTALLATION & SERVICE MANUAL. Display Panel

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Electrical Wiring Guide

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

INSTALLATION INSTRUCTIONS

AFCIs Come of Age. by Douglas Hansen

Fundamentals of Power

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

MCC Ratings. Voltage Rating

Secondary Unit Substations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Distribution Dry Type Transformers

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Ontario Electrical Safety Code 25 th Edition/ 2012

CITY OF LOS ANGELES CALIFORNIA

City of Riverside Building & Safety Division Residential Electric Vehicle (EV) Charger Guidelines

Utility Distribution Systems

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

INSPECTION GUDELINES

GENERAL WIRING RULES FOR HOUSES

October Safety Subject

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Grounding & Bonding Why it is done And How to Install Properly

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Installation and Operation Guide for PD4000 Series Power Control Center

Temporary Power Outlet Panels. Selection and Application Guide.

Section B: Electricity

Help protect your home, possessions and family.

Miniature Circuit Breakers and Supplementary Protectors

Evaluating Water-Damaged Electrical Equipment

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Reverse-feed applications for circuit breakers

TSn SERIES Surge Protective Device

Construction Electrical Terminology. Electricians

Evaluating Water-Damaged Electrical Equipment

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

Circuit Breakers. NRC Series. NRC Series

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Evaluating Water-Damaged Electrical Equipment

RAY-MAX Integrated Solar Power Strip

City of Riverside Building & Safety Division Phone: (951)

A guide to understanding and maintaining your home s electrical system. A publication presented by the Electrical Safety Foundation International

Building Permit Application

SENTRON Switching and Protection Devices Air Circuit Breakers

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Circuit Breaker. Description

Element D Services Electrical

NEC 2014 Code Changes

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Transcription:

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology to provide maximum available protection against the effects of arcing faults. Overview of the product: J United States Fire Administration (USFA) reported: - Annually, an estimated 28,300 residential electrical fires cause 360 deaths, 1,000 injuries, and $995 million in direct loss. - 15% of residential electrical fires start in bedrooms. - 47% of residential electrical fires are caused by the wiring. J Combination Type AFCI s are required by the 2005, 2008 and 2011 National Electric Code Product rating: UL listed General features and benefits: J 1 and 2 pole Combination Type AFCIs J Exclusive LED trip indicators indicate cause of last trip (ie. Arcing fault, arcing fault to ground, or overcurrent condition.) 1

Identifying applications: Used in Siemens and Murray load centers 1-Pole Combination Type AFCI LED indicator Last known trip condition Yellow 1 Yellow 2 OFF OFF Overcurrent ON OFF Arc fault ON ON Arc fault to ground Accessories J Siemens also offers a diagnostic tool called an Intelli-Arc that saves the electrician time and money in trouble shooting AFCI circuits: IDT5000 J Padlocking device: ECPLD1 Arc Fault Breaker Catalog Numbering System Q 1 20 AFC P Brand name No. of Poles Amperes Special Applications Packaging Q = Siemens MP = Murray 1 = 1 2 = 2 15 = 15A 20 = 20A (blank) = Standard breaker AFC = Combination Type Arc Fault Circuit Interrupter AF = Branch Feeder Arc Fault Circuit Interrupter (blank) = cardboard packaging P = Clamshell packaging for retail 2

Ground Fault Circuit Interrupters (GFCI) www.usa.siemens.com/gfci Definition of product: Ground fault circuit interrupter (GFCI) is designed to protect against severe electrical shock or electrocution from ground faults. Ground faults occur when the electrical current in an appliance strays outside its normal path, and the human body becomes part of the path through which the electrical current may flow. Overview of the product: J GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water. J 47% of residential electrical fires are caused by the wiring. J Current imbalances of 4-6 milliamps or more between load conductors will cause the ground fault sensor to trip the circuit breaker. Product rating: UL listed, CSA Certified 3

Identifying applications: Used in Siemens and Murray load centers General features and benefits: J Available in 1-pole (15-30A) and 2-pole (15-60A) J Common uses: spas, hot tubs, kitchens, bathrooms, garages, etc. J Resists false tripping (shielded to prevent RF interference) J Standard 1 inch per pole format with plug-in design J Provides Class A GFCI protection Ground Fault Breaker Catalog Numbering System Q F 1 20 P Brand name Ground Fault Indication No. of Poles Amperes Packaging Q = Siemens MP = Murray F = Ground Fault; 5mA personnel protection E = Ground fault; 30mA equipment protection 1 = 1 2 = 2 15 = 15A 20 = 20A 30 = 30A 40 = 40A 50 = 50A 60 = 60A (blank) = cardboard packaging P = Clamshell packaging for retail 4

Load centers PL and ES Series www.usa.siemens.com/loadcenters Definition of product: A load center is the point where all of the electricity enters and is distributed throughout the house. Overview of the product: J Copper Bus and Aluminum Bus variations J 100-225A, 1 and 3-phase, NEMA 1 and 3R J Main Lug and Main Breaker options Product rating: UL listed General features and benefits: PL Series J Copper Bus J Convertible from Main Lug to Main Breaker J 12-70 circuits/spaces J 2 Ground Bars factory installed J INSTA-WIRE neutrals and grounds 5

Identifying applications: Residential and multi-family electrical distribution General features and benefits: ES Series J Aluminum Bus J 12-70 circuits/spaces J Ground Bars field installed J INSTA-WIRE neutrals and grounds J Value Pack offering with 3 Q120 and 1 Q230 included 6

Load centers PL and ES Series www.usa.siemens.com/loadcenters Catalog Numbering System Type Enclosure or Component P = PL Series Indoor Type 1 12-70 circuits S = ES Series Indoor Type 1 12-70 circuits PW = PL Series Outdoor Type 3R 12-70 circuits SW = ES Series Outdoor Type 3R 12-70 circuits Spaces Maximum number of 1" breakers Circuits Maximum number of circuits Type of Main ML or L = Main Lug MB or B = Main Breaker System 1 = 1-Phase, 3-Wire 3 = 3-Phase, 3-Wire or 3-Phase, 4-Wire Main Ampere Rating Ex:100 = 100 Amps Trim/Others Blank = Combination S = Surface F = Flush T = Feed-Thru Lugs G or GB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper P = Aluminum Bus, Value Pack 7

Identifying applications: Residential and multi-family electrical distribution P 12 24 B 1 100 S CU 8

Load centers PL and ES Series www.usa.siemens.com/loadcenters Siemens load centers meet or exceed the following standards. J UL50 Electric Cabinets and Boxes J UL67 Electric Panelboards J UL486 Wire Connectors J UL489 Molded-Case Circuit Breakers J UL869 Service Equipment J UL943 Ground Fault interrupters (Class A Personnel Protection) J Federal Specification W-P-115b Panel Power Distribution J Federal Specification W-C-375B Circuit Breakers J NEC J NEMA 250 Underwriters Laboratories, Inc. reference file numbers: J Series Connected Circuit Breaker Information is recognized by UL under file #E10848(N) J Load Centers Listed by UL under file #E10703 J Load Centers UL recognized components found under file #E10703, Volume 6 and 7. (Also referenced under the recognized components directory section QEUY2) J EQ Circuit Breakers are Listed by UL under file #E82615 9

Identifying applications: Residential and multi-family electrical distribution Load center Accessories: Ground Bars: 2 included in all PL Series load center. Sold separately for ES Series. EC2GB15, EC3GB27 Filler Plates: Covers twist outs from a deadfront without a breaker to fill the space. ECQF3P Hubs: For use on outdoor load centers for water tight connection to conduit fittings. ECHS000, ECHS075, ECHS100, ECHS125, ECHS150, ECHS200 10

QN and MPD Breaker www.usa.siemens.com/residential Definition of product: The QN is used as both a branch breaker and a main breaker in applications which require a two pole, 120/240V AC breaker. Overview of the product: J 150, 175, and 200 A J 10k, 22K, 65K AIC Product rating: UL listed General features and benefits: J Available with a reverse handle mechanism Accessories J Padlocking device ECQLN3 11

Identifying applications: Used as a main breaker in small circuit load centers, circuit breaker enclosures, meter mains and meter combos. Used as a branch breaker to be a main disconnect for main lug only load centers. QN Breaker Catalog Numbering System QN 2 150 R H Interrupting Rating Brand name No. of Poles Amperes Handle operation Interrupting Rating (blank) = 10kAIC H = 65kAIC QN = Siemens MPD = Murray 2 = 2 150 = 150A 175 = 175A 200 = 200A (blank) = vertical applications R = horizontal applications (blank) = 10kAIC H = 22kAIC 12

MBK Breaker www.usa.siemens.com/residential Definition of product: Main breaker used in various Siemens load centers Overview of the product: J 2 Pole J 100, 125, 150, 200, 225 A J 22K AIC Product rating: UL listed General features and benefits: J 100 and 125A breakers have a smaller footprint than the 150A+ MBKs so they cannot be installed in 150A+ load centers for increased installation safety Accessories J Padlocking device ECQLN3 13

Identifying applications: Used in Ultimate load centers, 1 phase PL and ES load centers, riser panel load centers, and generator ready load centers Catalog numbers Siemens: MBK100A, MBK125A, MBK150A, MBK200A, MBK225A Murray: MBK100M, MBK125M, MBK150M, MBK200M, MBK225M 14

QP Breakers www.usa.siemens.com/residential Definition of product: 1 pole center branch breaker Overview of the product: J 1, 2, and 3 Poles (common trip) J Available as 120V, 120/240V, 240V AC J 10-125A J 10K, 22K, 65K AIC Product rating: UL listed General features and benefits: J Time saving INSTA-WIRE feature Accessories J Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECPLD3, ECPLD3R, ECQLD3, ECQLD4, ECQTH4 J Handle tie: ECQTH3 J Mechanical interlock: ECQML12 J Handle blocking device: ECQL1 15

Identifying applications: Used as a 1 pole center branch breaker for applications that require plug-in (QP) or bolt-on (BL) connections Standard Breaker Catalog Numbering System Q 1 20 H Brand name No. of Poles Amperes Interrupting Rating Q = Siemens plug-in MP = Murray plug-in 1 = 1 2 = 2 3 = 3 10 = 10A 15 = 15A 20 = 20A 25 = 25A 30 = 30A 35 = 35A 40 = 40A 45 = 45A 50 = 50A 60 = 60A 70 = 70A 80 = 80A 90 = 90A 100 = 100A 110 = 110A 125 = 125A (blank) = 10kAIC H = 22kAIC HH = 65kAIC 16

QT Breakers www.usa.siemens.com/residential Definition of product: 1/2 pole centers branch breakers offered as a duplex, triplex, and quadplex. Overview of the product: J 120/240V AC J Available as 120V, 120/240V, 240V AC J 10K AIC J 15-50A Product rating: UL listed General features and benefits: J Space saving design allows two poles to fit in a 1 panel space J Available without a rejection tab so it can be used with an unnotched stab (for panels built before the 1970s) Accessories J Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECQLD4 J Handle tie: ECQTH2 J Handle blocking device: ECBX23IM 17

Identifying applications: Used as branch breakers in Siemens load centers QT Breaker Catalog Numbering System Q 15 15 NC Brand name No. of Poles Amperes Amperes Special Application Q = Siemens MP = Murray (blank) = Duplex 2 = Triplex or Quadplex 15 = 15A 20 = 20A 30 = 30A 15 = 15A 20 = 20A 25 = 25A 30 = 30A 35 = 35A 40 = 40A 45 = 45A 50 = 50A (blank) = standard NC = Non-CTL for replacement use only in panels manufactured before 1968. CT = Triplex CT2 = Quadplex 18

One Pole Applications www.usa.siemens.com/residential Appliance Watts Voltage Amps Breaker Dishwasher 1200 120 20 Q120 Lighting Fixture 1200 120 15 Q115 Refrigerator/ Freezer 300/350 120 20 Q120 TV/DVD 300 120 20 Q120 Washing Machine 1200 120 20 Q120 Waste Disposal 300 120 20 Q120 *These are typical installations. Check with local codes, existing wire size installed, and ratings of the appliances before proceeding. 19

Two Pole Applications www.usa.siemens.com/residential Appliance Watts Voltage Amps Breaker Built-in Oven 4500 120/240 30 Q230 Central Air 6000 120/240 50 Q250 Clothes Dryer 5000 120/240 30 Q230 Range 12000 120/240 50 Q250 Range Top 6000 3300 120/240 30 20 Q230 Q220 Water Heater 4000 120/240 30 Q230 20

Surge Protection Device www.usa.siemens.com/surge Definition of product: 2 Wide plug-on containing two one pole circuit breakers and a surge arrester Overview of the product: J Utilizes Siemens-built 150V AC, 40mm, metal oxide varistor with maximum impulse rating of 40 ka J Rated 120/240V AC Product rating: UL listed General features and benefits: J Easy to install and perfect for retrofit J LEDs provide protection status J $20,000 warranty for the residential electrical system (Load center, internal wiring, receptacles, dimmers, hard wired appliances) J Surge protection at no loss of load center spaces 21

Identifying applications: Provides surge protection for all branch circuits in the load center of the residence at no loss of load center spaces Surge Protection Breaker Catalog Numbering System QSA 20 20 SPD Brand name Amperes Amperes Special Application QSA = Siemens MSA = Murray 15 = 15A 20 = 20A 15 = 15A 20 = 20A SPD = Surge Protection Device 22

Breaker Accessories www.usa.siemens.com/residential Padlocking Device: For locking breaker in "OFF" position. Note ON position does not affect breaker functionality. ECPLD1, ECPLD2, ECPLD2R, ECPLD3, ECPLD3R, ECQLD3, ECQLD4, ECQLN3, ECQTH4 Available for: QP, BL, QT, QN, QNR, 150A+ MBK Handle Tie: Provides simultaneous switching of 2 adjacent handles ECQTH2, ECQTH3 Available for: 2 Pole QP and QTs 23

Breaker Accessories www.usa.siemens.com/residential Mechanical Interlock: Mechanically interlocks two breakers so it is impossible for both to close at the same time ECQML12 Available for: QP and BL Handle Blocking Device: For holding device in ON and OFF position. Not a lockout/tagout device ECQL1, ECBX231M Available for: QP, BL, QT 24

Sustainable solutions from Siemens. Ready today for the home of tomorrow. Microinverter Systems DC AC inverters for solar PV J Increased energy production J Can be used in shaded areas and non-ideal rooflines J No DC wiring Improved safety Simple installation J Includes lifetime monitoring with Envoy purchase J 120/240 V and 120/208 V systems available www.usa.siemens.com / VersiCharge 25

Sustainable solutions from Siemens. Ready today for the home of tomorrow. VersiCharge Electric vehicle charging stations for home and fleet J Choice of four wiring methods to suit every install J Simple, intuitive user controls J Adjustable amperage output J 30 A and 70 A models to suit present and future vehicles J Unmatched feature set at competitive price point J VersiCharge SG is Smart Grid ready Wireless communications User and utility programmable Optional revenue grade metering Available in multiple colors to match decor www.usa.siemens.com / VersiCharge 26

The information provided in this pocket guide contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com All rights reserved Subject to change without prior notice RPPG-REFGD-0812 Printed in USA 2012 Siemens Industry, Inc. www.usa.siemens.com