EUROPEAN TECHNICAL APPROVAL ACCORDING TO ETAG 005 - EXPLANATIONS -



Similar documents
Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

European technical approval

European Organisation for Technical Approvals

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

European technical approval

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L)

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

European Technical Approval ETA 13/0526

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

European Technical Approval ETA-10/0124

Page 1 of European Technical Approval ETA-12/0495

European Technical Approval ETA 13/0384

European technical approval

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

European Technical Assessment ETA-15/0028 of 23/02/2015

Page 1 of European Technical Approval ETA-08/0018

European Technical Assessment ETA-15/0652 of 27/10/2015

This European technical approval

ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F mail@oib.or.at

Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014

Eurooppalainen tekninen hyväksyntä ETA - 13/0613 European Technical Approval

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Safety Storage Cabinets

Fire Stopping and Sealing Product: Penetration Seals

CE mark now! Mandatory CE marking of construction products 1 July 2013

European Technical Approval ETA-12/0500

WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL

Intelligent Roofing Systems Flat roofs Roof details. The specialist for liquid applied waterproofing

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

European Technical Approval ETA-06/0259

Certification of construction products - Fire dampers. Certification Rules 032

Europeiskt Tekniskt Godkännande European Technical Approval

ETAG 011 LIGHT COMPOSITE WOOD-BASED BEAMS AND COLUMNS

Understanding BS EN 771-3: Aggregate concrete masonry units

Europeiskt Tekniskt Godkännande European Technical Approval

Product. Regulations. Agrément Certificate No 06/4388. Designated by Government to issue European Technical Approvals

ETAG 022. GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL of Watertight covering kits for wet room floors and or walls

Elastic, 1-part-polyurethane, liquid waterproofing membrane

DOW CORNING SENEFFE (Belgium) DOW CORNING GmbH WIESBADEN (Germany) This version replaces ETA 03/0003 valid from until

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

European Technical Approval ETA-08/0121

Test Report No. C829QPEN

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

APPENDIX 1 EUROPEAN STANDARDS AND MARKINGS FOR HEAD PROTECTION. ISSUE 8: January 2013

Eurooppalainen tekninen hyväksyntä ETA-12/0045 European Technical Approval

European Technical Approval ETA 13/0282

European Technical Assessment ETA-10/0153 of 10/06/2015

Your essential guide to CE Marking

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

LE MARAIS Series White Body Wall Tiles

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

WATERPROOFING OF WET ROOMS

PYROSWISS VETROFLAM CONTRAFLAM

temperature needed to reach the sintering necessary to make the product frost-proof, non-absorbing and resistant to chemical attacks.

Construction Products Regulation

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

synthetic waterproofing systems

PRODUCT SHEET 1 COLD FUSION BONDED BUILT-UP ROOFING SYSTEMS

European technical approval ETA-10/0460

Chapter 2 Basis of design and materials

CONIROOF : Tailor-made Solutions for your Roof CONIROOF

DECLARATION OF PERFORMANCE

Out - Ecrano / White Charcoal

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Quality Regulations for Profiles

European Technical Approval ETA-10/0200

European Technical Approval ETA-09/0040

European Technical Approval ETA 12/0419

Prefabricated building PVC vertical sliding window

ROOFS, SNOW AND ICE DAMS

Early installation guidelines

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

Transferring Solar Energy

US Safety Data Sheet GEAR OIL SAE 10W/30 GEAR OIL SAE 10W/30

NATIONAL ANNEX TO STANDARD SFS-EN 1990 EUROCODE BASIS OF STRUCTURAL DESIGN

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

FINAL DRAFT pren

PIPES, TANKS and ANCILLARIES not in contact with water intended for human consumption

Emergency safety showers Part 3: Body showers for production and logistic sites

EXPERT OPINION on the applicability of the construction technology "GRÈMOUND non-tectonic system on grounds of the documentation submitted

Fire safety in buildings and implementation of European fire test standards

Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011

Annex of the certificate (Page 1/6) Accreditation Scope

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

[4] SA1.2 The student demonstrates an understanding of the processes of science by observing,

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

Transcription:

EUROPEAN TECHNICAL APPROVAL ACCORDING TO ETAG 005 - EXPLANATIONS -

1. Particular Abbreviation ETZ : Europäische Technische Zulassung ETA : European Technical Approval ETAG : European Technical Approval Guideline/ Leitlinie für Euopäische Technische Zulassung EOTA : European Organisation for Technical Approvals CE : Conformité Européenne/Communauté Europeénne LARWK: Liquid Applied Roof Waterproofing Kit 2. Legal Basis Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products Essential Requirements ER1: Mechanical resistance and stability ER2: Safety in case of fire ER3: Hygiene, health and the environment ER4: Safety in use ER5: Protection against noise ER6: Energy economy and heat retention CE - marking and information The ETA shall indicate the information to accompany the CE-marking, the placement of CE-marking and the accompanying information (eg. on the kit and/or components, an attached label, the packaging or on the accompanying commercial documents). 3. ETAG 005 Each (LARWK) shall be classified according to Part 1 - clause 4.7.2 as follows: 1. external fire performance 2. reaction to fire Each (LARWK) shall be categorised according to Part 1 - clause 4.7.3 as follows: 3. expected working life 4. climatic zone of use 5. user loads 6. roof slopes 7. minimum surface temperatures 8. maximum surface tempratures www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 2/7

Each (LARWK) shall have, according to Part 1 clause 5.3.1 9. a declared value regarding water vapour permeability Each (LARWK) shall have, according to Part 1 clause 5.3.2 10. a declaration regarding presence of dangerous substances Categorisation according to working life Category W1 Category W2 Category W3 Expected working life (years) 5 10 25 The indication given on the working life of assembled system(s) cannot be interpreted as a guarantee by the Applicant (or the Approval Body) but is regarded only as a means of choosing the appropriate products in relation to the expected economically reasonable working life of the works Categorisation according to climatic zone Category M Moderate climate Category S Severe climate Annual radiant exposure < 5 GJ/m2 5 GJ/m2 on horizontal surface Average temperature of the warmest month per year and < 22 C and/or 22 C Note 1: The annual radiant exposure is the total amount of solar energy received by horizontal global surface within a defined geographical region, calculated as a mean measured value over a period of five years. The average temperature of the warmest month is the calculated mean value over a period of five years for the average measured maximum air temperature of that month. Note 2: The "isoline 5" can be used as an indicative dividing line between "moderate" and "severe" climatic zones of use www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 3/7

Categorisation according to user loads Category User load Examples of accessibility P1 Low non-accessible P2 Moderate accessible for maintenance of the roofing only P3 Normal accessible for maintenance of plant and equipment and to pedestrian traffic P4 Special roof gardens, inverted roofs, green roofs Categorisation according to roof slopes Category Slope (%) S1 < 5 S2 5-10 S3 10-30 S4 > 30 Examples of possible related effects - frost (thickness of ice layer) - UV/standing water - effects of standing water - plant roots (roof gardens and green roofs) - frost (thickness of ice layer) - UV - plant roots (green roofs only) - sliding - frost (freezing snow) - UV - plant roots (green roofs only) - sliding - UV www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 4/7

Categorisation according to minimum surface temperature of the assembled system Category Climatic zone Surface protection Minimum surface Temperature ( C) TL1 All climatic zones Inverted roofs and roof gardens (excluding + 5 "green"roofs) TL2 Moderate low temperature - 10 TL3 TL4 Severe low temperature All other protected assembled systems or exposed roofs - 20 Extreme low temperature* - 30 * Note: The particular location(s) for which Category TL4 has to be taken into account may be declared by Member States Categorisation according to maximum surface temperature of the assembled system Category Climatic zone Surface protection Maximum surface Temperature ( C) TH1 TH2 TH3 All climatic zones Moderate high temperature Inverted roofs and roof gardens 30 Exposed, uninsulated roofs or heavily protected 60 roofs Exposed, insulated roofs 80 TH4 Severe high temperature * Exposed, insulated roofs 90 * Note: For southern European regions considered as having "severe" climatic conditions related to high surface temperatures (area south of indicative "isoline 5) www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 5/7

4. METHODS OF VERIFICATION To gain high categories, one has to match higher demands. Following some examples: Resistance to fatigue movement A fully bonded assembled system shall be subjected to fatigue movements at - 10 C. The number of cycles to which the assembled system shall be subjected will be determined by the categorisation of the kit according to the expected working life and is defined in a table. Number of cycles of fatigue movement Categorisation of expected working life Number of cycles W1 250 W2 500 W3 1000 Resistance to heat ageing The effects of heat ageing on the resistance to mechanical damage shall be verified by subjecting an assembled to heat for a period defined by the categorisation according to climatic zone and the categorisation according to expected working life. The relationship between these aspects and the period of exposure is given in a Table. Relationship between climatic zone, working life and period of exposure to heat Climatic zone category Moderate (M) Severe (S) Working life category W1 W2 W3 W1 W2 W3 Exposure period (days) 25 50 100 50 100 200 Resistance to water ageing The effects of water ageing shall be determined by exposing the upper surface of the assembled system to water. The period of exposure will be determined by the categorisation of working life and of the roof slope of the kit. www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 6/7

Relationship between application, working life and exposure period Application Exposure period (days) Kategorie W1 W2 W3 S1 or S2 15 30 60 P4 Not applicable * 90 180 Note: The categorisation according to expected working life of kits for applicaion in roof gardens, inverted roofs and green roofs (P4) shall be at least 10 years (W2) 5. European Technical Approvals KEMPER SYSTEM KEMPEROL V 210 KEMPEROL BR KEMPEROL 1K-PUR KEMPEROL 2K-PUR ETA-03/0025 ETA-03/0026 ETA-03/0043 ETA-03/0044 Classifications and Categories are the same for all LARWK KEMPEROL: 6. Example for CE-Mark 8 E www.kemper-system.com post@kemper-system.com Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001 Page 7/7