System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611



Similar documents
Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Drayton Digistat +2RF/+3RF

RF 1. Contents: Connecting diagram. Detailed information:

4-Channel Thermometer / Datalogger

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

GSM ATT Modules Simply effective remote control

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Heating Controller. Building Technologies HVAC Products

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Fused Spur Time Switch

Modular I/O System Analog and Digital Interface Modules

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Voltage Regulator SPAU 341 C. Product Guide

instabus KNX / EIB System System E F G H

MAGICAR M871A. Car alarm with two-way remote User s guide

EK908FHL - Thermostat for floor heating

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Operating instructions TSE Wireless Software Business +

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

DVB-T2 DIGITAL TV BOX

Programming made easy. talento plus

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DVB-T 730. User s Manual

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Point of view HDMI Smart TV dongle Mini RF Keyboard

VIPER 400 ENGLISH ENGLISH

1 Technical Description Lokal-200PC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

H203D 中文 GB Version 1

Quick Connect. quick - simple - efficient.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Product Information Sheet UH36 Hi Pot Tester

Safety technique. Emergency stop module BO 5988 safemaster

Application Unit, MDRC AB/S 1.1, GH Q R0111

Current Monitoring Kit

Wahl C50 Calibrator FEATURES

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Operating instructions TSE Wireless Software Home

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

12 Series - Time switches 16 A. Features

TR7322U-OR RDS / MP3-USB TUNER (24 Volt)

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

DALI RC BASIC SO. Control unit Operating instructions

SD Memory Card Recorder Instructions. ver

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

PR-2500 Portable Receiver. Owner s Manual

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Combi B Alarm box. Mounting instructions

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DAB DIGITAL RADIO MODEL: CANVAS USER MANUAL

B/S/H/ Error codes and service programmes PH

SKR - industry relay

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Disturbance Recoder SPCR 8C27. Product Guide

E-STOP relays, safety gate monitors

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

User Manual. Humidity-Temperature Chart Recorder. Model RH520

HyperAccess Access Control System

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Air-conditioning controller. User's Manual NRT 107 F031, F R R2 Sauter Components

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

TS510 & TS500. Installation & User Guide. Compatible Equipment

NX Series Inverters. HVAC Pocket Programming Guide

is then retained absolutely without interruption.

Electrical Safety Tester

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Manual. PC-Software Save`n carry PP 50 pro

EBDSPIR-PRM, EBDSPIR-PRM-IP

Temperature & Humidity SMS Alert Controller

Tebis application software

OZW30. Central Unit SYNERGYR

NC-12 Modbus Application

Centro-Matic Automatic Lubrication Systems System Controls

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

Wireless Thermostats 230v and Battery Operated Instruction Manual

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

How To Program An Autodialer

Receiver and Remote Controls

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

FIREDEX Conventional Fire Panels

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

PS42309C INSTRUCTION MANUAL

Drayton Digistat +2RF

Plena Weekly Timer. Installation and User Instructions PLN-6TMW

Transcription:

DT1-IK 2CSM204275R0611 DT1-IK/24V 2CSM204285R0611 DT1-IK/DCF 2CSM204295R0611 DT2-IK 2CSM204325R0611 System pro M GB -1- WEEKLY DIGITAL TIME SWITCH + PROGRAMMING KEY I -11- INTERRUTTORE ORARIO DIGITALE SETTIMANALE + CHIAVE DI PROGRAMMAZIONE F -21- INTERRUPTEUR HORAIRE ÉLECTRONIQUE + CLÉ DE PROGRAMMATION D -31- ELEKTRONISCHE WOCHENSCHALTUHR + PROGRAMMIERSCHLÜSSEL E -42- INTERRUPTOR HORARIO ELECTRÓNICO + LLAVE DE PROGRAMACIÓN P -52- INTERRUPTOR HORÁRIO ELECTRÓNICO + CHAVE DE PROGRAMAÇÃO RU -62- Электронный таймер недельный + ключ программирования

GB Technical specifications Product delivered with current time and date set. Automatic change of winter/summer time. Programming key - for permanent waivers, - or program copy or save. Programming for day or group of days. 56 program steps On/Off or impulses (1sec to 30 mn). Permanent overrides On or Off ( permanent light on). Temporary overrides On or Off ( flashing). Holiday mode : overrides On or Off between two dates. Display bar graph of daily profile. Simulation of presence. Keyboard locking possible. Programmable with power off (réf. DT1-IK, DT1-IK/24V et DT2-IK). Back lit display (réf. DT1-IK and DT2-IK) Remotely temporary waivers (réf. DT1-IK only). Electrical characteristics Supply voltage: DT1-IK, DT1-IK/DCF, DT2-IK 230 V AC ± 15% DT1-IK/24V 12 V AC/DC+20% -10% 24 V AC/DC+10% -15% Frequency: 50/60 Hz Power consumption: DT1-IK/24V: max. 0,8 VA to 50 Hz DT1-IK/DCF: max. 5 VA to 50 Hz DT1-IK, DT2-IK: max. 6 VA to 50 Hz Output DT1-IK, DT1-IK/24V, DT1-IK/DCF: 1 changeover volt free contact. Output DT2-IK: 2 changeover volt free contacts. Maximum load: AC1 (DT1-IK, DT1-IK/DCF, DT2-IK) µ16a 250 V~ DC1 (DT1-IK/24V) µ4a 12 V Cos φ = 0,6 µ10a 250 V~ Minimum current: AC1 (DT1-IK, DT1-IK/DCF, DT2-IK) 100 ma 250 V~ DC1 (DT1-IK/24V) 100 ma 12 V Galvanic insulation between power supply and output: < 4 kv 1

Functional characteristics Programming capacity: 56 steps Minimum time between 2 steps: 1 minute Running accuracy: ± 1,5 Sec / 24 h Operating reserve: lithium battery provides 5 years of backup. The product is set in standby mode (display is off) if power goes off. It is set back in auto mode when power is back on. With power off, the screen display is turned on when striking any key. After one minute, it is turned off. Protection degree: IP 20 Operating temperature: -5 C to +55 C Storage temperature: -20 C to +70 C Lighting loads 230 V 2300 W 2300 W 500 W compensated // (max. 45 µf) 400 W non compensated, compensated in series 1000 W Cable connection 1 > 6 mm 2 1,5 > 10 mm 2 2

Connection diagram DT1-IK L / + N / - L N DT1-IK/DCF DT-DCF (DT1-IK) 5 6 7 8 5 6 7 8 1 2 3 4 1 2 3 4 DT2-IK L N 5 6 7 8 C2 C1 1 2 3 4 Program reset: the program may be completely cleared by simultaneously pressing the 3 following keys: menu, enter,. The time and the date will be kept. Total reset: pressing simultaneously the -, +, enter, menu, keys lets you clear the entire contents of the product. Following a total reset it is necessary to reset the time and day of the device. 3

DT1-IK/DCF DT1-IK, DT1-IK/24V DT2-IK You may return into auto mode at any moment using menu. If no action is taken for 1 min., the switch returns into auto mode. + C1 + C2 enter menu enter menu 2 4 3 1 DT-VK Keys: ➀ menu : selection of operating mode. auto : mode of running according to the program selected. prog : new for programming mode. prog : modif to modify an existing program. : checking of the program. : modification of time, date and selection of the winter/summer timechange mode : holidays. ➁ + and - : navigation or setting of values. - (DT1-IK, DT1-IK/24V, DT1-IK/DCF) or C1 and C2 (DT2-IK): in auto mode, sélection of overrides, waivers or random operation.. ➂ enter : to validate flashing information on display. ➃ : to return to the previous step. 4

Programming: prog new Programming may be done for each day or for a group of days. In this case instructions are common to several days. Days: 1 = Monday, 2 = Tuesday, 3 = Wednesday... 7 = Sunday. On 0 prog 6 12 new ok 18 24 1. Select the prog mode using menu, then enter. 1a DT2-IK: Select the channel (C1 or C2) using + or -, then enter. The number of remaining program steps appears for a short time. 2. Select the day(s) using + or -. Validate with enter. 3. ok flashes. Use enter to validate the group. - or makes it possible to reset the group of days if necessary. 4. Using + or -, select the state of the instruction: On, Off or. Validate with enter 5. Enter the time of switch-on using + or -. Validate with enter 6. Enter minutes with + or -. Validate with enter. 7. For one, set the duration (seconds, then minutes) in the same way as for the switch-on schedule. Program the other instructions of the group of days by repeating operations 3 to 7. The day or the group of days may be modified at the during step 3 by pressing +, - or. At the end of programming return to auto mode using the menu button. DT2-IK: To set the program of the other channel, return to prog new mode and proceed according to steps 1a. to 7. In this mode it is also possible to add an instruction to the program set up. Proceed as described above. 5

Display: To check the daily profile set up without the risk of modification or deletion: Select the mode using menu and enter. DT2-IK: Select the channel (C1 or C2) using + or - and enter. The first step of Monday is displayed as well as the daily profile. Two options available for display: 1. Pressing repeatedly + or -: lets you shift days. In this case only the first daily step is displayed as well as the daily profile. 2. Pressing enter: all steps of each day appear one after the other. Modification or clearing of a program step: prog modif Select the prog mode with menu and press enter. DT2-IK: Select the channel (C1 or C2) using + or - and press enter. Select the modif mode with + or -. Validate with enter. The number of remaining program steps appears for a short time. The first step of the first day or group of days appears. Repeatedly pressing the enter key displays all programmed steps one at a time. Any flashing field (state, hour, minutes) may be modified using + or -, then validated with enter. When the cursor is positioned on ok located behind the group of days, you may display successively the days or the groups of days and switch directly to the one that has to be modified using + or -. To remove a program step: select the state of the channel (On, Off or ), press simultaneously + and -. Clear.appears on the screen. Validate with enter. Key (only ref. DT1-K and DT2-K) As soon as the key appears on the switch Two types of operation: appear on the screen. 6

A. Permanent override: Insert the key into the switch. After 10 seconds the program contained in the key will be executed without clearing the program contained in the time switch. As soon as the key is removed the program of the time switch is again valid. B. Copy (load) / Save (save): The key makes it possible to save a program contained in the time switch. It is also possible to copy the contents of the key into the clock. 1. Insert the key and wait for 2 sec. 2. Using menu, select the mode: save : to save a program contained in the time switch, load : to load the program of the key into the time switch, : to check the program contained in the key. 3. Validate the selection with enter. 4. For save and load reconfirm with enter. The following error messages may appear on the screen: no prog : the key is empty, it does not contain any program. Error : DT1-IK, DT1-IK/24V, DT1-IK/DCF: the key is that of a two-channels switch. DT2-IK: the key is that of a one-channel switch. In these two cases: Only the save mode is possible. The error message remains on display as long as the key is present, but in this case the program of the time switch is executed. Setting time and day Winter/summer time change DT1-IK/DCF: Automating setting of time/date and winter/summer time change using ref. DT-DCF antenna. Hourly messages are sent from DCF77 transmitter to the antenna out of Frankfurt (Germany). Upon anenna's connection, the symbol flashes on screen. A soon as time has become synchronous flashing stops. In case of transmission failure or bad reception, switch relies on its own internal time base. 7

Time is set manually. DT1-IK, DT1-IK/24V, DT1-IK/DCF DT2-IK: Select the mode with menu then enter. Modify the day, month, year, the hour and the minutes using + or - and enter. The time switch next suggests the winter / summer time changes. Select the type of change desired using + or -. Validate with enter. The type of change depends on the geographical zone. Types available: (* = type according defect) Type Start of time Start of time Zone of change Summer change Winter application Euro Last Sunday Last Sunday European * of March of October Union USER Date freely Date freely programmed programmed No No No change change The change always takes place between 2:00 and 3:00 a.m. Note: For United Kingdom, use the geographical area EURO. For USA, use the type USER and enter following dates: Beginning of the summer-time 2nd Sunday of Mars, beginning of winter-time the 1st Sunday of November. Example: for an installation in 2007 enter 11.03 and 04.11 by following the instructions below. When the USER type is selected: 1. Enter the day then the month of the date of change of the summer time (+ 1hour) with + or - and enter. 2. Enter the day then the month of the date of change of the winter time (- 1hour) with + or - and enter. The time switch will check which days of which weeks correspond to these dates and will apply changes to the same periods for the following years independently of the date. 8

Holidays Allows you to override the output, On or Off for a given period. Once done, this override will be removed and will not be carried over to the following year. Select the mode using menu then enter. DT2-IK : Select the channel (C1 or C2) using + or - and enter. With + or -, select the state of override: On or Off, enter to validate. Enter the day then the month of the starting period (date 1) using + or - then enter. Enter in the same way the day and the month of the ending period (date 2). In auto mode, flashes to indicate that a period of holidays was programmed. becomes permanent during the period. The override will be effective at 0:00 of the 1st date until 23:59 from the 2nd date. If date 1 is set before the day of programming, the period of holidays is valid for the following year. To clear a period of holidays return to the mode, press simultaneously the + and - keys. Clear appears. Confirm with enter. Override - waivers - Random operation DT1-IK, DT1-IK/24V, DT1-IK/DCF: Pressing repeatedly on -. DT2-IK: Pressing repeatedly on C1 or C2. If the state of the output is On: 1 st pressure: temporary waiver. Off and flash. The next program step will let you return to the automatic mode. 2 nd pressure: permanent override. On and are permanent. This override must be cancelled manually. 3 rd pressure: permanent override. Off and are permanent. This override must be cancelled manually. 4 th pressure: random operation. Simulation of presence:, as well as the state of the output are displayed. Must be cancelled manually. In this case the steps of the program are shifted randomly within a range of ± 59 min. 5 th pressure: return to the automatic mode. 9

Entry of override (DT1-IK only) Makes it possible to remotely set temporary waivers. When a 230V voltage is applied using a non lighted push-button on connector 8, the state of the time switch is reversed until the next program step. Locking To prevent all undesirable actions, the keyboard of the time switch may be locked using a key DT-LK or pressing the enter and keys for 7 seconds. Unlocking is done in the same way. Full product reset remains feasible when the keyboard is locked. Dimensions 43,8 60 35,8 5 6 7 8 45 85 1 2 3 4 52 10

ABB SACE S.p.a P.O. Box 622 V.le dell Industria, 18 20010 Vittuone (Mi) ITALY