PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems



Similar documents
PVS Series - Models 185, 600, 1200, 1800 and 2700

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700

Vacuum Dehydration Oil Purification System (VDOPS)

SMR Series Submicronic Removal Fluid Purifi cation Systems

DIESEL FUEL CONDITIONING

CSD WATER REMOVAL FILTERS FOR DIESEL

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

ThermoSorb Desiccant Dryers

Your oil can be saved!! Even when water is mixed

The Par-Gel Filter Water Removal Filter Elements

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

15/40/80CN Series Medium Pressure Filters

Kompressoren. Adsorption Dryer AD

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

ECOCIAT. Domestic hot water heat recovery unit

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Medical Air Systems: Scroll

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Adsorption air dryers ADS 1 215

ThermoStar Refrigeration Air Dryers

Sentinel Portable Purification System

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

15/40/80CN Series Coreless Medium Pressure Filters

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Explosion-Proof Electric Unit Heaters

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Model 1210C Battery Powered Pump Shown. Description

Refrigeration Compressed Air Dryer Buran Ultrapulse

HFS and HFD Series. High Flow Single and Duplex Filters Max l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

A New Membrane System for Efficient Removal of Water from Gear Oil Road to Commercialization

Basic Hydraulics and Pneumatics

Article published: May 2004,

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Centro-Matic Automatic Lubrication Systems System Controls

300 Series PA Pump and Cooler Assemblies

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Overheating limit control

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS)

What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008

MEMBRANE VACUUM MINI PUMPS


Standard Hydraulic Piping Flushing Procedure

UNITOR VACUUM cleaners

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Air Eliminators and Combination Air Eliminators Strainers

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Kompressoren. Oil Water Separators OWS

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Pro Dry Heatless dessiccant compressed air dryers

Mechanical shaft seal types and sealing systems

Hydraulic Control Solutions


Technical Specification. Generating Set with Waukesha engine burning natural gas

MANTA Piston Distributor for Oil and Fluid Grease

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

Hydraulic control unit series

PUMP AND MOTOR DIVISION

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Rotary screw compressors kw 5,5 7, , bar MODULO

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Oil and Coolant Circulating Heating System. Model - OCSM

TRANSLATION OF THE ORIGINAL MANUAL

UNITOR ULTRASONIC cleaning

LT Series Lubricant Management System (LT-LMS)

6 Crankcase Ventilation

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Electric Flow Boiler

Hydraulic Trouble Shooting

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Filter Elements E /05.06

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

FRL/AirCare Air Controls & Accessories

Automatic Back-Flushing Filter AutoFilt RF9.

FT-100 Fire Training Fog Machine User Manual English

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Ultra-Filter. Compressed Air Filter. DF Series

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Flushing and Cleaning the A/C System

KNC Model 3666 Automatic Pressure Calibration System

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Unit 24: Applications of Pneumatics and Hydraulics

Diesel Fuel Filtration

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Clean Fuel & Lubricant Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Flex separation systems, S-separators

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

Transcription:

185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology

PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by a vacuum of 846.5 millibars (25 In/Hg). The oil passes through the in-line low watt density heater where the oil is heated to an optimum temperature of 66 C (150 F). The oil then enters the distillation column where it is exposed to the vacuum through the use of special dispersal elements. This increases the exposed surface area of the oil and converts the water to vapour form, which is then drawn through the condenser by the vacuum pump. The water-free oil falls to the bottom of the column and is removed by a heavy duty lube oil pump. This pump forces the dry oil though a final particulate removal filter. Clean oil passes out of the unit, back to the reservoir and into the system. Effects of Water Contamination Water is one of the most common contaminants in a fluid system and one of the most damaging. When water contaminates a system, it can cause serious problems such as: TYPICAL SATURATION POINTS Fluid Type PPM % Hydraulic Fluid 300.03 Lubrication Fluid 400.04 Transformer Fluid 50.005 Free water occurs when oil becomes saturated and cannot hold any more water. This water is usually seen as cloudy oil or puddles of water at the bottom of an oil reservoir. Water which is absorbed into the oil is called dissolved water. At higher temperatures, oil has the ability to hold more water in the dissolved stage due to the expansion of oil molecules. As the oil cools, this ability reverses and free water will appear where not visible before. In addition to temperature, fluid type also determines the saturation point for your system (see chart above). Corrosion by etching metal Fluid breakdown, reduction of lubricating properties, Effect Of Water In Oil On Bearing Life additive precipitation, and oil oxidation 250 Reduced dielectric strength Abrasive wear in hydraulic components % Bearing Life Remaining 200 150 100 50 0.0025% = 25 ppm 0.01% = 100 ppm 0.05% = 500 ppm 0.10% = 1000 ppm 0.15% = 1500 ppm 0.25% = 2500 ppm 0.50% = 5000 ppm 0 0.0025 0.01 0.05 % Water in Oil 0.10 0.15 0.25 0.50 Effect of water in oil on bearing life (based on 100% life at.01% water in oil). Reference: Machine Design July 86, How Dirt And Water Effect Bearing Life by Timken Bearing Co. 162

APPLICATIONS FOR PORTABLE PURIFICATION SYSTEMS Paper Mills Dryer Lubrication Hydraulic Compressor Lubrication Calendars Steel Mills Bearing Lubrication Continuous Casters Press Roll Lubrication Power Generation Turbine Oil Transformer Oil EHC Systems Industrial/Aerospace Test Stands Machine Tools AIR COOLED CONDENSER SELF DIAGNOSING CONTROLS CONDENSATE HOLDING TANK VACUUM PUMP CASTER WHEELS REVERSE POLE SWITCH/PHASE FAIL PROGRAMMABLE THERMOSTAT LOW WATT DENSITY HEATER LIQUID LEVEL SIGHT GLASS FORKLIFT GUIDES Condensate holding tank Features Advantages Benefits Captures removed water/solvents Large enough to provide long service interval Eliminate potential hazard of exhausting to atmosphere Reduced maintenance costs Compact size Forklift guides Programmable thermostat Automatic operation Reverse pole switch/phase fail High temperature safety circuit Circuit breakers utilised in electrical panel Available with EPR seals and Stainless Steel Solid state heater contactor Smallest envelope in the industry Ease of portability Provides safe and secure method to lift unit Maintains oil within 0.5 C (0.9 F) Prevents overheating oil Unattended use Change motor rotation for different power source locations Shuts down heater if primary contactors fail Oil can never exceed 121 C (250 F) No fuses to replace Simple diagnostics Phosphate ester compatible Longer more reliable service life Fits through doorways and down narrow aisles Increased use Employee safety Easily transported Unattended operation Increases oil life Reduced labour costs Increased running time Flexibility, less maintenance Prevents incorrect rotation Prevents system damage Worker safety Fewer spare parts, increased uptime Reduced maintenance costs Specifically designed for application Reduced downtime 163

Potential Contaminant Solid particulate Water Air Gases * When utilising 2Q media Performance ISO Cleanliness Code* 14/13/10 Attainable Removes 100% of free water, 80-90% of dissolved water. Removes 100% of free air, 90% of dissolved air. Removes 100% of free gases, 90% of dissolved gases. (Vacuum Dehydration) Compared to Other Technologies TYPICAL PERFORMANCE Tank Size 227 Litres (60 USG) Run Time 62 Minutes Parker Model 600 Water Content (ppm) Start: 10,000 PPM (1.0%) Stop: 50 PPM (0.005%) Contamination Level Start:ISO 21/18/16 Stop: ISO 16/14/11 Centrifuge units Removes free water only; has difficulty breaking stable emulsions; larger envelope dimensions but lower flows; higher initial and operating costs. Desiccant units Have limited water removal capability due to absorbing material; only removes air ingressed particles; expensive compared to the volume of water removed. Coalescer units Removes free water only; has difficulty breaking stable emulsions; does not work well in viscous fluids (>23cSt); much larger in size compared to. START STOP Total Hours Estimated Water Removal Time 5000 ppm (0.5%) to 150 ppm (0.015%) Reservoir Size (Litres) 0 5000 10000 15000 20000 25000 30000 120 100 80 60 40 20 185 600 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Reservoir Size (Gallons) 1200 35000 1800 2700 164

SPECIFICATION Flow Rate: 19 l/min (5 USGM) Height: 1524mm (60 ) Width: 635mm (25 ) Length: 914mm (36 ) Weight: 227.3 Kg (500 lbs) Seal Material: Fluorocarbon (EPR opt.) Condensate Tank: 15.5 ltrs (4.1 gal) Dispersal Elements: 1 Minimum Operating Capacity: 19 ltrs (5 USG) Vacuum (max): 846 millibar (25 In/Hg) Viscosity (max): 105 cst (500sus) Disposable cst (2150 sus) Packed Tower Outlet Pressure (max): 4.1 bar (60 psi) Ports: 3 /4 JIC (male) inlet 3 /4 JIC (male) outlet FLA (Full Load Amps): 15-30 amps (Depending on voltage used) Portable Purification Systems 185 Replacement Elements PARTICULATE 2Q (2 micron) 932665Q 5Q (5 micron) 932666Q 10Q (10 micron) 932667Q 20Q (20 micron) 929927Q DISPERSAL Disposable 933180 (Coalescing) Packed Tower 933553 (Cleanable) 02QE 05QE 10QE 20QE ECOGLASS III 932665Q 932666Q 932667Q 929927Q Flow Direction High Level Switch Low Oil Flow Switch 185 Flow Diagram Vacuum Gauge Oil Discharge Pump Model 8OCN-2 Absolute Filter Low Watt Density 8.75L (2.3 gal) Tank Condensate Drain Air Cooled Condenser Inlet Flow High Level Condensate T Dry Sealed Vacuum Pump Oil Lubricator 165

600 SPECIFICATION Flow Rate: 37.9 l/min (10 USGM) Height: 1524mm (60 ) Width: 635mm (25 ) Length: 914mm (36 ) Weight: 341 Kg (750 lbs) Seal Material: Fluorocarbon (EPR opt.) Condensate Tank: 15.5 ltrs (4.1 USG) Dispersal Elements: 2 Minimum Operating Capacity: 22.7 ltrs (6 USG) Vacuum (max): 846 millibar (25 In/Hg) Viscosity (max): 108 cst (500sus) Disposable cst (2150 sus) Packed Tower Outlet Pressure (max): 4.1 bar (60 psi) Ports: 1 JIC (male) inlet 1 JIC (male) outlet FLA (Full Load Amps): 24-38 amps (Depending on options & voltages) Replacement Elements PARTICULATE 2Q (2 micron) 932665Q 5Q (5 micron) 932666Q 10Q (10 micron) 932667Q 20Q (20 micron) 929927Q DISPERSAL Disposable 933180 (Coalescing) Packed Tower 933553 (Cleanable) 02QE 05QE 10QE 20QE ECOGLASS III 933734Q 933612Q 933735Q 933736Q Air Breather (Liquid Ring Only) High Level Switch Flow Direction T Low Oil Flow Switch Vacuum Gauge Oil Discharge Pump Low Watt Density Heater (11 WPSI) WPSI Watts p Model 8OCN-2 Absolute Filter 600 Flow Diagram Air Cooled Condenser Option 5.5L (4.1 USG) Tank Condensate Drain High Level Condensate T Inlet Flow Dry Sealed Vacuum Pump Water Cooled Condenser Option Oil Lubricator Cooling Water In (5.7 l/min) (1.5 USGM) Cooling Water Out Seal Water Inlet (5.7 l/min) (1.5 USGM) Liquid Ring Vacuum Pump 166

SPECIFICATION Flow Rate: 75.7 l/min (20 USGM) Height: 1651mm (65 ) Width: 813mm (32 ) Length: 1219mm (48 ) Weight: 636 Kg (1400 lbs) Seal Material: Fluorocarbon (EPR opt.) Condensate Tank: 31.4 ltrs (8.3 USG) Dispersal Elements: 4 Minimum Operating Capacity: 41.6 ltrs (11 USG) Vacuum (max): 846 millibar (25 In/Hg) Viscosity (max): 108 cst (500sus) Disposable cst (2150 sus) Packed Tower Outlet Pressure (max): 4.1 bar (60 psi) Ports: 1 1 /2 NPTF inlet 1 JIC (male) outlet FLA (Full Load Amps): 30-48 amps (Depending on options & voltages) Portable Purification Systems 1200 Replacement Elements PARTICULATE 2Q (2 micron) 932665Q 5Q (5 micron) 932666Q 10Q (10 micron) 932667Q 20Q (20 micron) 929927Q DISPERSAL Disposable 933180 (Coalescing) Packed Tower 933553 (Cleanable) 02QE 05QE 10QE 20QE ECOGLASS III 933734Q 933612Q 933735Q 933736Q Air Breather (Liquid Ring Only) High Level Switch Flow Direction Model IL8-3 Absolute Filter T Low Oil Flow Switch Oil Discharge Pump 1200 Flow Diagram Vacuum Gauge Low Watt Density Heater (11 WPSI) WPSI Watts p Air Cooled Condenser Option 3.4L (8.3 USG) Tank Condensate Drain High Level Condensate T Inlet Flow Dry Sealed Vacuum Pump Water Cooled Condenser Option Oil Lubricator Cooling Water In (5.7 l/min) (1.5 USGM) Cooling Water Out Seal Water Inlet ( 5.7 l/min) ( 1.5 USGM) Liquid Ring Vacuum Pump 167

1800 SPECIFICATION Flow Rate: 113.6 l/min (30 USGM) Height: 1651mm (65 ) Width: 1016mm (40 ) Length: 1829mm (72 ) Weight: 772 Kg (1700 lbs) Seal Material: Fluorocarbon (EPR opt.) Condensate Tank: 31.4 ltrs (8.3 USGM) Dispersal Elements: 8 Minimum Operating Capacity: 68.1 ltrs (18 USG) Vacuum (max): 846 millibar (25 In/Hg) Viscosity (max): 108 cst (500sus) Disposable cst (2150 sus) Packed Outlet Pressure (max): 4.1 bar (60 psi) Ports: 2 NPTF inlet 1 1 /2 JIC outlet FLA (Full Load Amps): 40-65 amps @ V/60hz Replacement Elements PARTICULATE 2Q (2 micron) 932872Q 5Q (5 micron) 932873Q 10Q (10 micron) 932874Q 20Q (20 micron) 929875Q DISPERSAL Disposable 933180 (Coalescing) Packed Tower 933553 (Cleanable) 02QE 05QE 10QE 20QE ECOGLASS III 933734Q 933612Q 933735Q 933736Q 168

SPECIFICATION Flow Rate: 170.3 l/min (45 USG) Height: 1778mm (70 ) Width: 1524mm (60 ) Length: 1829mm (72 ) Weight: 817 Kg (1800 lbs) Seal Material: Fluorocarbon (EPR opt.) Condensate Tank: 31.4 ltrs (8.3 USG) Dispersal Elements: 8 Minimum Operating Capacity: 68.1 ltrs (18 USG) Vacuum (max): 846 millibar (25 In/Hg) Viscosity (max): 108 cst (500sus) Disposable cst (2150 sus) Packed Outlet Pressure (max): 4.1 bar (60 psi) Ports: 3 NPTF inlet 2 NPTF outlet FLA (Full Load Amps): 50-70 amps @ V/60hz Portable Purification Systems 2700 Replacement Elements PARTICULATE 2Q (2 micron) 932665Q 5Q (5 micron) 932666Q 10Q (10 micron) 932667Q 20Q (20 micron) 929927Q DISPERSAL Disposable 933180 (Coalescing) Packed Tower 933553 (Cleanable) 02QE 05QE 10QE 20QE ECOGLASS III 933734Q 933612Q 933735Q 933736Q 169

ORDERING INFORMATION Select the desired symbol (in the correct position) to construct a model code. BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 600 DS D 5Q 12 AC DFL Box 1 Box 2 Box 3 Box 4 Seals Basic Assembly Capacity Power Supply Fluorocarbon EPR None E8 Portable Purification System 18.9 lpm (5 USGM) 37.9 lpm (10 USGM) 75.7 lpm (20 USGM) 113.6 lpm (30 USGM) 170.3 lpm (45 USGM) 185 600 1200 1800 2700 Model 185 600 1200 1800 2700 220VAC, 1P, 60HZ 230VAC, 3P, 60HZ 380VAC, 3P, 50HZ VAC, 3P, 60HZ 575VAC, 3P, 60HZ 230VAC, 3P, 60HZ 380VAC, 3P, 50HZ VAC, 3P, 60HZ 550VAC, 3P, 60HZ 380VAC, 3P, 50HZ VAC, 3P, 60HZ 550VAC, 3P, 60HZ 380VAC, 3P, 50HZ VAC, 3P, 60HZ 550VAC, 3P, 60HZ 380VAC, 3P, 50HZ VAC, 3P, 60HZ 550VAC, 3P, 60HZ 220 230 380 550 230 380 550 380 550 380 550 380 550 Box 5 Box 6 Box 7 Vacuum Pump Dispersal Element Degree of Filtration/Particulate Element Pressure Setting Average filtration ratio ß (ISO 16889) / particle size µm(c) CODE Dry Sealed DS Disposable (Coalescing) D 2 10 75 100 200 1000 Liquid Ring LR Packed Tower (Cleanable for use with viscious or highly contaminated fluids) P N/A N/A N/A N/A N/A 4.5 N/A N/A 4.5 5 6 7 N/A 6 8.5 9 10 12 2Q 5Q 10Q 6 11 17 18 20 22 20Q Box 8 Box 9 Box 10 Box 11 Filter Housing Heater Condenser Options 80CN-2 IL8 (39 ) Ecoglass III Upgrade None E Note: IL8 option is available on 600 models, and is standard on 1200 models and larger Model 185 600 1200 1800 2700 3 KW (1 phase) 10 KW (3 phase) 12 KW 24 KW 24 KW 36 KW 48 KW 3 10 12 24 24 36 48 Air Cooled Liquid Cooled CODE AC LC Pneumatic Wheels Auto Condensate Drain Dirty Filter Light Resetable Hour Meter Sight Flow Indicator Variable Flow Circuit CODE PW ACD DFL RHM SFI VFC Inlet Control Valve ICV CE CE CSA CSA Explosion Proof EXP 170