1 Clean Fuel & Lubricant Solutions Filters Filter Heads Manifolds Kits Fuel Carts hp Filters and Heads DEF TRAP Accessories Why Filter Fuels & Lubricants? Today s sophisticated equipment, such as diesel engines with increased injection pressures, requires higher cleanliness levels than ever before. Donaldson bulk filtration systems save on costly component replacement, prevent unplanned downtime and prevent a decrease in fuel efficiency due to injector wear. In short, Donaldson reduces your total cost of ownership. Learn more about all things related to diesel fuel at MyCleanDiesel.com.
2 Table of Contents Why Do I Need Clean Fuel? What is Clean Fuel? How Do I Get Clean Fuel? Clean Diesel Kits Clean Diesel Carts Fuel and Lubricants Filters Filter Heads Manifolds Bulk hp Filters and Heads Clean DEF Filter T.R.A.P. Breather Reservoir Air Dryer Accessories System Sizing and Design Filter Flow Rates and Pressure Drops 2 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
3 Why do I Need Clean Fuel? DIESEL IS DIRTY. As diesel travels from refinery to terminal locations to local bulk storage and finally to your bulk tank, it picks up contamination that is deadly to today s engines. DIRT IS BAD. Your local distributor likely delivers diesel that meets or exceeds fuel-industry standards for cleanliness. This is not clean enough for your equipment. REMOVE THE DIRT. ACHIEVE MORE. By filtering dirt, water and other contaminants before your fuel ever touches your equipment, you ll eliminate costly downtime, Keep Running and Achieve More. GET A CLEAN SOLUTION. To ensure that you re pumping clean, dry fuel into your equipment, call or a Donaldson Clean Solutions expert. No matter where you are or the size of your operation, there s a Clean Solution that will help you Achieve More. donaldsonfilters.com Clean Fuel & Lubricant Solutions 3
4 What is Clean Fuel? Achieving the Target Cleanliness of a Fluid ISO 446 contamination codes are a way to express fluid cleanliness. The three numbers correspond to the number of particles 4 microns and larger, 6 microns and larger, and 14 microns and larger present in the fluid. This page illustrates what it means to start with a contamination of ISO 22/21/18 and target a cleanliness of ISO 14/13/11. RECOMMENDED ISO CLEANLINESS RATINGS ISO 14/13/11 Target rating for diesel fuel ISO 446 CONTAMINATION CODES Range of number of particles per 1 milliliters CODE MORE THAN UP TO & INCLUDING 24 8,, 16,, 23 4,, 8,, 22 2,, 4,, 21 1,, 2,, 2 5, 1,, 19 25, 5, 18 13, 25, 17 64, 13, 16 32, 64, 15 16, 32, 14 8, 16, 13 4, 8, 12 2, 4, 11 1, 2, 1 5 1, µm+ 6 µm+ 14 µm+ ISO 22/21/18 Typical cleanliness as fluid goes into your equipment ISO 22 / 21 / 18 ISO 16/14/11 Target rating for hydraulic/ transmission oils 4 µm+ 6 µm+ 14 µm+ ISO 18/16/13 Target rating for heavy gear/engine oils ISO 14 / 13 / 11 4 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
5 What is Clean Fuel? SIZES OF FAMILIAR PARTICLES IN MICRONS 1 µm 8 µm 4 µm 25 µm 1 µm 8 µm 2 µm <.5 µm Grain of Table Salt Human Hair Lower Limit of Visibility White Blood Cell Talcum Powder Red Blood Cell Bacteria Silt Donaldson Delivers Water Protection Are your bulk fluids passing large amounts of free water downstream contaminating vehicles and equipment? Donaldson s water absorbing filter with super absorbent polymer media, DBB248, will stop flow if large amounts of free water are detected in your ethanol-free fluids. Designing systems with water absorbing filters requires careful sizing considerations. A Donaldson specialist will assist in configuring a system that meets your specific needs for flow and pressure drop. Choosing the Ideal Filters for Your System Doesn t Need to be Complicated Select the right filter to achieve targeted ISO cleanliness. Proper design of the system will help avoid unnecessary costs. Determine the working pressure of the system and select the filter line compatible with that pressure. Different types of fluids have different properties. Fluid viscosity plays an important role in restricting the flow through filters. Select a filter that has compatible media-tofluid properties and will maintain adequate flow and avoid excessive pressure drops. See pages 3-31 for filter flow rates and pressure drops. donaldsonfilters.com Clean Fuel & Lubricant Solutions 5
6 How Do I Get Clean Fuel? Donaldson Delivers Superior Bulk Fluid Filtration Lower Total Cost of Ownership Avoid Unplanned Downtime Maximize Fuel Efficiency Low Installation Costs Custom Designs Modular Solutions Compact Installation Low Inventory Costs Easily Shipped Easily Serviced Clean. Protect. Donaldson single-pass filtration on the inlet removes contamination before it can enter your storage tank and contaminate it. Compact and easy to replace, Donaldson filters are an important line of defense in maintaining fluid quality and can be configured for high flow rates while minimizing pressure drop. Water absorbing filters, T.R.A.P. Breathers and Reservoir Air Dryers reduce the risk of moisture and contaminants entering a bulk storage tank so fluids are kept clean and dry. Used together, they ll help guard fluids from free water, airborne contamination and microbial growth for as long as they stay in storage. 6 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
7 How Do I Get Clean Fuel? CLEAN PROTECT Polish. POLISH Unstable fluids and the tank itself can be a source of contamination. Final filtration on the outlet with Donaldson filters ensures that targeted ISO cleanliness levels are achieved before fluids are pumped into your system. Achieve More. donaldsonfilters.com Clean Fuel & Lubricant Solutions 7
8 Clean Diesel Kits Clean Diesel Kits Donaldson Clean Diesel Kits provide simple, effective outlet filtration on fuel dispensers to allow you to pump clean fuel into your vehicles and equipment. These kits are easy to install on any fuel dispenser and come with everything needed to filter out even the finest contaminants before they can enter your equipment s fuel system. With the included easy-to-follow, step-by-step instructions, you ll have effective, efficient filtration in minutes. COMPACT X11745 Parallel Filtration For flow rates up to 32 GPM / 121 LPM The Compact Clean Diesel Kit is designed for use on mobile service trucks, slip tanks, D-tanks, inside fuel dispensers and other tight locations. HIGH-CAPACITY X1145 Parallel Filtration For flow rates up to 125 GPM / 473 LPM The High Capacity Clean Diesel Kit includes a dual head with two identical filters plumbed in parallel to accommodate higher flow rates and usage volumes. STANDARD X11448 Parallel Filtration For flow rates up to 65 GPM / 246 LPM The Standard Clean Diesel Kit is perfect for smaller operations that need clean fuel delivered efficiently in any environment. CLEAN AND DRY X11449 Series Filtration For flow rates up to 5 GPM / 189 LPM The Clean and Dry Diesel Kit removes fuel contamination, stops water and provides extra protection for your fuel in storage with the T.R.A.P. Breather. See page 13 for Parallel and Series Filtration Flow Paths 8 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
9 Clean Diesel Carts Clean Diesel Carts Clean Diesel Carts are the perfect solution for fuel transfer and kidney loop applications. A high efficiency fuel filter and water absorber (included) work together to ensure that your diesel is both clean and dry. The carts are powered by top quality pumps in your choice of AC 12V, DC 12V, or DC 24/12V. Maximum flow rates range from 15 gpm / 56 lpm to 21 gpm / 8 lpm, which makes short work of cleaning small to medium sized tanks. Easy to read, green to red service indicators on the two filters function independently, alerting the operator when one of the filters needs changing. AC Clean Fuel Cart 12-Volt DC Clean Fuel Cart 24-Volt DC Clean Fuel Cart Part Number X1147 X1148 X11431 Replacement Filter Elements Target ISO Cleanliness Fluid Compatibility DBB8666 Fuel Filter & DBB248 Water Absorbing Filter 14/13/11 or better All diesel fuels and up to B2 bio-diesel blends Efficiency 4 Beta 2 Water Absorbing Filter Service Interval Stops all free and emulsified water 25 psi service indicator moves from green to red Pump Model Piusi Panther 56 Piusi Panther DC 12V Piusi Panther DC 24/12V Power Consumption 7 Watts 42 Watts (35 12V) 6 Watts (25 24V) 192 Watts (16 12V) Working Pressure 23 psi / 16 kpa / 1.6 bar 22 psi / 15 kpa / 1.5 bar Relief Internal bypass valve Max. Flow Range 15 gpm / 56 lpm 15 gpm / 56 lpm 18 gpm / 7 24V 9 gpm / 35 Duty Cycle Continuous 3 minutes 3 minutes donaldsonfilters.com Clean Fuel & Lubricant Solutions 9
10 Fuel and Lubricants Filters Fuel and Lubricants Filters Donaldson Clean Solutions filters provide unsurpassed cleanliness in a single pass. They are perfect for inlet and outlet filtration applications. Their spin-on design enables fast and simple filter changes without special tools and provides greater protection from contamination during service than traditional cartridge style filters. These filters incorporate our best technology and construction to handle all fuels and lubricants in all as operating environments. Donaldson Electrostatic Reduction Technology (DERT) prevents filter media damage from electrostatic discharge. Epoxy is used in filter construction for increased fluid compatibility. E-coating provides maximum corrosion resistance and epoxy adhesion. Viton O-rings provide reliable sealing and maximum fluid compatibility. Viton is a registered trademark of E.I. DuPont de Nemours and Company. FEATURES Highly efficient, state-of-the-art filter media and design Unsurpassed filter efficiency Cleans to target ISO cleanliness in a single pass Modular design can be configured for virtually any flow rate or usage level Fast and easy to service APPLICATIONS Single pass filtration for clean fluid transfers High efficiency kidney looping Inlet and outlet filtration at bulk storage tanks Dispenser polishing filtration on fuel pumps and hose reels Mobile and stationary applications D.E.R.T. Donaldson Electrostatic Reduction Technology Filter media damage from Electrostatic Discharge (ESD). Electrostatic discharge can be created when diesel fuel or light oils pass through filter media at high flow rates. The fluid being filtered may have inadequate conductivity to dissipate the charge generated by high flow filtration applications. The electrical charge can build-up in the fluid until it discharges or sparks across the filter, burning holes in the filter media and letting through harmful contaminants. Donaldson s proprietary Electrostatic Reduction Technology neutralizes electrical charge and prevents damage to the filter media. This enables efficient single pass fuel filtration in high flow applications. 1 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
11 Fuel and Lubricants Filters Compact Fuel Filter Compact Winter Fuel Filter Fuel Filter Winter Fuel Filter Light Oil Filter Heavy Oil Filter Water Absorbing Filter Part Number DBB5333 DBB7733 DBB8666 DBB8777 DBB8665 DBB8664 DBB248 Target ISO Cleanliness * 14/13/11 or better 16/14/11 14/13/11 or better 16/14/11 16/14/11 18/16/13 Not Applicable Efficiency 4 Beta 2 7 Beta 2 4 Beta 2 7 Beta 2 25 Beta 2 Not Applicable Fluid Compatibility All diesel fuels Transmission and hydraulic oil Engine and gear oil Ethanol-free fluids Recommended Viscosity Range Working Pressure Element Collapse Pressure Rated Static Burst <1 <5 <6 <15 35 psi / 2413 kpa / 24.1 bar 15 psi / 134 kpa / 1.3 bar 8 psi / 5516 kpa / 55.2 bar Max. Flow Range ** 32 gpm / 121 lpm 65 gpm / 246 lpm D.E.R.T. *** Yes No Nominal Dimensions 5" x 7.5" / 12.7 cm x 19.1 cm 5" x 14.25" / 12.7 cm x 36.2 cm Operating Temperature -4 to 245 F / -4 to 118 C -4 to 19 F / -4 to 88 C -4 to 245 F / -4 to 118 C * Select the proper filter by fluid type and OE recommended ISO code. Do not over-filter fluids. Doing so may result in the stripping of beneficial additive. ** Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading. *** DERT Donaldson Electrostatic Reduction Technology prevents media damage during high flow fuel applications. See pressure drop/flow rate charts on page donaldsonfilters.com Clean Fuel & Lubricant Solutions 11
12 Filter Heads Filter Heads Clean Solutions filter heads feature robust, aluminum construction with steel inserts to minimize metal-to-metal galling between the head and the filter, even when used with diesel fuel. The threaded insert contains an O-ring seal to completely seal the clean side of the filter from the dirty side for maximum protection. Viton seals are compatible with a wide range of fluids and maintain their integrity in cold weather. For maximum cleanliness, use Clean Solutions filter heads with Clean Solutions filters. Viton is a registered trademark of E.I. DuPont de Nemours and Company. FEATURES Steel inserts are safe to use with diesel fuel Threads contain an O-ring to completely seal the clean side from the dirty side of the filter Heads are pre-ported for optional pressure gauges and service indicators APPLICATIONS For use with Clean Solutions filters Compatible with all diesel fuels and lubricants Single Filter Head Single Filter Head 11/4" NPTF Dual Filter Head Part Number P57329 P5733 P Connection SAE-2 O-ring 11/4" NPTF 11/2" SAE 4-Bolt Code 61 Flange Filter Quantity * Max. Flow Range ** Fluid Compatibility Working Pressure Rated Static Burst 65 gpm / 246 lpm All diesel fuels and lubricants 35 psi / 2413 kpa / 24.1 bar 8 psi / 5516 kpa / 55.2 bar 125 gpm / 473 lpm Operating Temperature -4 to 245 F / -4 to 118 C Indicator Port Materials Compatible Filters Use to adapt pressure gauges or samping ports (sold separately) Aluminum head with threaded steel inserts and Viton seals DBB8664, DBB8665, DBB8666, DBB5333, DBB248, DBB8777, DBB7733 * Filters sold separately ** Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading. 12 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
13 Filter Heads 73.2 [2.88] INDICATOR PORT Single Filter Head P57329 P [5.3] 35 [1.38] 47.8 [1.88] 3/8-16 UNC 4-PLACES 4.1 [1.58] DIRECTION OF FLOW 23.9 [.94] 39.1 [1.54] Filter Heads Pressure Drop Single Head Dual Head [.75] SAE-2 O-RING & 1¼ NPTF Dual Filter Head Pressure Drop Dual Filter Head P [5.3] 3.7 [11.84] 23.2 [8.] [2.82] 3/8-16 UNC 4-PLACES [5.7] INDICATOR PORT DIRECTION OF FLOW 57.7 [2.27] [3.6] 1 1/2 SAE 4-BOLT CODE 61 FLANGE 5.8 [2.] Single Filter Head Pressure Drop [.75].8 Single Head Flow Path Dual Head With Parallel Flow Path Single Heads in Series Remove Dirt First, Then Water Flow In Flow Out Flow In Flow Out Flow In Flow Out donaldsonfilters.com Clean Fuel & Lubricant Solutions 13
14 Manifolds Manifolds Clean Solutions Filter Manifolds expand capacity or increase flow rate beyond the capability of a single or dual filter head. Two or more manifolds can be plumbed together to accommodate even larger flow rates. Manifolds split flow evenly between the individual filters. Fluid passes through only one of the filters on its way across the manifold. Dividing the flow between multiple filters plumbed in parallel reduces the pressure drop through each filter. The combination of Clean Solutions manifolds and filters ensure that your equipment receives the cleanest possible fuel and oil. 4 Filter Manifold 8 Filter Manifold 1 Filter Manifold Inline 12 Manifold * Part Number P56188 P P DFF112 Filter Quantity ** Up to 12 Mounting Connection 2" ANSI 15 Flange 4" ANSI 15 Flange Max. Flow Range *** 25 gpm / 946 lpm 5 gpm / 1893 lpm 6 gpm / 2271 lpm 7 gpm / 265 lpm Shipping Weight 14 lbs / 64 kg 31 lbs / 141 kg 39 lbs / 177 kg 128 lbs / 58 kg Pressure Gauges 2 pcs -16 psi / -11 bar gauges included Accessories Sold Separately Sampling Fluid Compatibility Includes up-stream and down-stream mini-mess sampling ports with M16 x 2 thread All diesel fuels and lubricants Working Pressure Construction ANSI B16.5 flange rating 29 psi / 1999 kpa / 2. bar up to 1 F / 38 C Painted carbon steel pipe with aluminum heads 15 psi / 134 kpa / 1.3 bar No external aluminum Compatible Filters DBB8664, DBB8665, DBB8666, DBB8777, DBB248 Operating Temperature -4 to 245 F / -4 to 118 C * Inline 8 Manifolds are available upon request. ** Filters sold separately *** Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading. 14 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
15 Manifolds FEATURES Fast, easy and safe to service Requires no electrical or air hook-ups Large capacity in small footprint Flexible mounting options (horizontal or vertical) Cost effective high capacity system APPLICATIONS Bulk fuel and lubricant filtration and water removal High flow transfer into or out of tanks and dispensing equipment Hard-to-filter high viscosity oils Inline industrial filtration of gear oils and lubricants Kidney loop applications 4 Filter Manifold P [22.42] 2 Manifold Pressure Drop DOWNSTREAM M16 X 2 MINI MESS TEST PORT DIRECTION OF FLOW [17.5] DOWNSTREAM M16 X 2 MINI MESS TEST PORT P56188 P P DFF ANSI 15 FLANGE 2 ANSI 15 FLANGE Filter Manifold P [24.45] 1 Filter Manifold P [22.42] ELECTRIC INDICATOR PORT Inline 12 Manifold DFF X BLEEDER VALVES 2X M16X2 MINI MESS TEST PORT Blanking caps and other accessories see page ANSI 15 FLANGE 4" BORE [3.88] [17.5] DIRECTION OF FLOW UPSTREAM M16 X 2 MINI MESS TEST PORT DOWNSTREAM M16 X 2 MINI MESS TEST PORT UPSTREAM M16 X 2 MINI MESS TEST PORT DIRECTION OF FLOW DOWNSTREAM M16 X 2 MINI MESS TEST PORT 4 ANSI 15 FLANGE 4 ANSI 15 FLANGE 4 ANSI 15 FLANGE 4 ANSI 15 FLANGE donaldsonfilters.com Clean Fuel & Lubricant Solutions 15
16 Bulk hp Filters and Heads Bulk hp Filters and Heads Filtering oil prior to dispensing into equipment is critical to meet the ISO cleanliness specifications demanded by today s OEM s. Donaldson Bulk hp filters provide high efficiency filtration in a single pass. Service shops use high pressure pumps to force oil through long lengths of piping and hose reels prior to dispensing into equipment. Donaldson Bulk hp filters remove contaminants delivered in oil and picked up in storage or delivery lines during final transfer. They ensure the required ISO cleanliness level is met every time. hp Single Head hp Head with Bypass Part Number P56623 P56624 Working Pressure Indicator 1 psi / 6894 kpa / 68.9 bar Yes Bypass Valve Connections No SAE-16 O-ring Yes - 5 psi / 345 kpa / 3.4 bar Bulk hp Filter Bulk hp Filter Bulk hp Filter Part Number P P P Target ISO Cleanliness 14/13/11 16/14/11 18/16/13 Fluid Compatibility Petroleum based oils Max. Flow Range 5 gpm / 189 lpm Efficiency 4 Beta 2 8 Beta 2 14 Beta 2 Working Pressure 1 psi / 6894 kpa / 68.9 bar Element Collapse Pressure 3 psi / 268 kpa / 2.7 bar Application Rated Static Burst Hydraulic, gear, transmission and engine oils 22 psi / 15,168 kpa / bar 16 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
17 Bulk hp Filters and Heads FEATURES Up to 1 psi / 6894 kpa / 68.9 bar working pressure Extended life filters with high dirt holding capacity Easy disposal with recyclable can and incinerable element Compact design requires only 1.5" / 38 mm clearance for servicing APPLICATIONS Lube shops Mobile service trucks Other higher pressure single pass applications Bulk hp Filter Heads P56623 P [4.5] 34.9 [1.38] hp Filter Head Pressure Drop [1.38] M1 X 1.5 X 11 4X 66.5 [2.62] 19. [.75] [4.72] INDICATOR PORT SAE-16 O-RING DIRECTION OF FLOW 35.1 [1.38] 19.5 [4.31] See pressure drop / flow rate curves on page 31. Bulk hp Filters P P P [3.7] 25.8 [9.88] 38.1 [1.5] CLEARANCE FOR FILTER CHANGEOUT THERMAL EXPANSION Donaldson highly advises following the pump manufacturer s relief recommendations. Pump manufacturers offer relief valves to protect against over pressurization. A mere 1 F / 5.5 C increase in oil temp can add 45 psi / 313 kpa / 31 bar to the system while the pump is shut off. donaldsonfilters.com Clean Fuel & Lubricant Solutions 17
18 Clean DEF Filter Clean DEF Filter Today s Selective Catalytic Reduction (SCR) emissions control systems require clean Diesel Exhaust Fluid (DEF) for precise dosing and complete atomization to occur. However, contamination from transfer and storage or corrosion from incompatible materials can prevent your SCR system from getting the clean DEF it needs for proper operation. The Donaldson DEF filter catches contaminants before they reach your vehicle or equipment and the onboard DEF filter. Clean DEF ensures proper function of the SCR and extends the life of the onboard DEF filter. SCR DEF NO x Reduction DEF Dosing Module PM Reduction DEF must be clean for proper dosing to occur and turn NOx from exhaust into harmless nitrogen and water vapor. DPF Pre-Filter DEF Filter FEATURES 1 micron at beta 5 efficency 316 stainless steel housing Precise knife edge internal seal Heavy duty construction Maximum working pressure of 3 psi Leak-free O-ring seal Integrated gauge/sample ports Replacement filters available individually DEF Filter Housing (Choice of Connection) DEF Filter Element DEF Housing O-ring Efficiency Max. Flow Range Working Pressure P " NPT P " BSPT Both models include mounting bracket and filter wrench P57559 sold separately P5756 replacement part 1 Beta 5 (99.98%) 1 gpm / 38 lpm 3 psi / 268 kpa / 2.7 bar Operating Temperature 12 to 122 F / -11 to 5 C APPLICATIONS DEF dispensers up to 1 GPM Housing Construction Filter Material Indicator Port Drain Plug 316 stainless, EPR O-ring Polypropylene, EPDM gaskets 1/4" NPT, upstream and downstream 1/4" NPT 18 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
19 Clean DEF Filter PART NUMBERS P57557 DEF Filter Housing 1" NPT P57558 DEF Filter Housing 1" BSPT P57559 Clean DEF Filter P5756 DEF Housing Replacement O-ring MOUNTING BRACKET DEF Filter Pressure Drop DEF Filter Housing P57575 P /4-2 X 3/8 DEEP 1/4 NPT DRAIN PLUG 87.9 [3.46] 48.3 [1.9] 38.1 [1.5] 87.9 [3.46] 2X 1/4 NPT GAUGE PORT 63.5 [] 18.2 [.72] [13.69] 2.1 [.79] 25.4 [1.] CLEARANCE FOR FILTER CHANGEOUT 2X 1 NPT OR BSP 14.8 [4.13] Stainless steel pressure gauge not included must be sourced seperately. DEF IS HIGHLY CORROSIVE. All pipe fittings must be compatible with DEF. Most plastics as well as stainless steel are acceptable. Carbon steel, zinc, aluminum, brass, copper, etc. are not recommended due to undesirable chemical reactions. If any of these materials are used in your system they should be immediately replaced with a compatible material. donaldsonfilters.com Clean Fuel & Lubricant Solutions 19
20 T.R.A.P. Breather T.R.A.P. Breather The Thermally Reactive Advanced Protection (T.R.A.P.) Breather assembly protects the fluids in your storage tank from airborne pvarticulate moisture contamination and ambient moisture. It combines a high capacity 3 micron air filter with a deliquescent breather that dries itself when air is expelled from the tank. This self-regenerating capability of T.R.A.P. enables extended life and functionality. Keep your fluids clean and dry with a Donaldson T.R.A.P. Breather. Tanks sizes above 1, gal. / 37,854 l. may require multiple units and pressure vaccum relief valves. Contact Donaldson for assistance. T.R.A.P. Breather FUEL LEVEL DECREASES Assembly Part Number Efficiency Max. Flow Range Overflow Check Valve Operating Temperature Fluid Compatibility Indicator Height Construction Connection Replacement filter X926 97% 3 microns Combined inlet and outlet flow up to 4 gpm / 15 lpm maximum Opens at 1 mbar / 4" H 2 O -4 to 2 F / -4 to 93 C Safe for use with all fuels and lubricants Standard mechanical 16" / 41 mm ABS housing, Urethane end caps 11/2" NPT female P92375 spin on 2 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
21 T.R.A.P. Breather FEATURES High efficency air filtration Longer life and lower airflow restriction than typical silica gel breathers Self-regenerating moisture adsorption Easy to service APPLICATIONS For use with all diesel fuels and lubricants Above and below ground tanks Mobile service trucks Indoor or outdoor applications Most tanks up to 1, gal. / 37,854 liters (large tanks may require multiple units) Flow Restriction (in H2O) T.R.A.P. Breather Restriction Flow Restriction (kpa) T.R.A.P. Breather X926 Ø176.5 [6.95] MOIST AIR D R Y A I R DR Y AIR MOIST AIR Bulk Tank Breather & Moisture Prevention T.R.A.P TM Replace per Indicator (Maximum 4 months) Installation date: 363 [14.29] SEPERATES HERE FOR SERVICING Always locate your tank s name plate and cross check against the flow chart above to ensure safety. Use maximum flow INTO tank for validating pressure rating and flow OUT OF tank for vacuum ratings. DO NOT EXCEED TANK PRESSURE OR VACUUM. donaldsonfilters.com 1 1/2 NPT CONNECTION 15 [4.13] Clean Fuel & Lubricant Solutions 21
22 Reservoir Air Dryer Reservoir Air Dryer The Donaldson Reservoir Air Dryer eliminates the need to continually replace conventional desiccant breathers, enhancing reservoir breathing systems by continuously purging and dehydrating reservoir headspace. With no electrical requirements, the Donaldson Reservoir Air Dryer combats ambient ingression of moisture by introducing a steady stream of clean, dry air to the reservoir. This constant airflow helps sustain optimal conditions and prevents the formation of condensation and rust in the reservoir, minimizing the potential for particulate and water ingression through reservoir access points. When combined with a T.R.A.P. Breather, the complete system keeps moisture and contamination out, even if fluid flow rate out of the tank surpasses the Reservoir Air Dryer flow rate into the tank. Reservoir Air Dryer Assembly Part Number Efficiency Outlet Flow psi and dew point suppression Inlet Air 1 psi Pre-Filter Condition Pressure Regulator Coalescer Drain Max Working Pressure Max Operating Temperature Fluid Compatibility Inlet/Outlet Connection Mounting Bracket Weight Replacement P Reduces dew point as much as 15 F (83 C).5 scfm (14.2 slpm) maximum.8 scfm (22.7 slpm) maximum Visual Indicator (Green/Red) Dial Gauge Automatic Float Type 116 psi (8 kpa / 8. bar) 125 F (52 C) Petroleum and Phosphate Ester Fluids, Diesel Fuels * 1/4 NPT 3/8-16 UN Threaded Nut <5 lbs (<3 kgs) Coalescing Pre-Filter * The Reservoir Air Dryer is not recommended for use on gasoline holding tanks or for the head space of any flammable liquid (Flash Point of 1F/38C) 22 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
23 Reservoir Air Dryer FEATURES The clean, dry air sweep dehydrates the reservoir headspace and removes dissolved moisture from exposed oils and fuels * Operates with standard plant air; instrument quality air is not required. Submicron coalescing air filter collects oil and water droplets and fine particles from inlet air Automatic drain purges captured liquid with no intervention required Visual indicator monitors filter condition Membrane air dryer reduces plant air dew point by as much as 15 F (83 C) Pressure regulator depressurizes the air and ensures that the proper flow rate of air is introduced into the reservoir APPLICATIONS Lubricant system reservoirs Diesel storage tanks Oil storage tanks Gear boxes Hydraulic system reservoirs * The Reservoir Air Dryer is not recommended for use on gasoline holding tanks or for the head space of any flammable liquid (Flash Point of 1F/38C) 6. in ( 15.2 cm ) Reservoir Air Vent P in ( 8.9 cm ) AIR OUTLET 1/4" NPT H AIR INLET 1/4" NPT donaldsonfilters.com Clean Fuel & Lubricant Solutions 23
24 Accessories Accessories PARTS Part Number Description Application DFF15 I-12 Blanking Cap Blank off up to 6 orifices on I-12 manifold for flush mounting P Bolt Code 61 Flange to 11/2" NPT Adapter Adapts P Dual Head to 11/2" NPT P Threaded Pipe Nipple 1 1 /4" NPT, for connecting two P5733 single heads in series P1645 Threaded Insert O-rings Replacement O-rings for heads and manfiolds, Viton, not for use on hp P ABS Breather, 3 Micron Small oil tanks under 25 gal. / 1 liters, 1" NPT, splash containment for mobile applications PRESSURE GAUGES AND SERVICE INDICATORS Part Number Description Application P Electrical Service Indicator 5 psi / 345 kpa / 3.45 bar Use with all Clean Solutions heads and manifolds, microprocessor compatible P Visual Service Indicator 5 psi / 345 kpa / 3.45 bar For single heads and hp heads, industrial grade green to red P Visual Service Indicator 25 psi / 172 kpa / 1.72 bar For single heads and hp heads, industrial grade green to red P Upstream Pressure Gauge Adapter For single and dual heads, 1 / 8" NPT P Pressure Gauge, 6 psi / 414 kpa / 4.1 bar For single and dual heads, 1 / 8" NPT, center back mount, 11/2" diameter, use with P adapter P Pressure Gauge, -1 psi / 689 kpa / 6.89 bar For single and dual heads, 1 / 8" NPT, center back mount, 2" diameter, use with P adapter P56389 Direct Gauge Adapter For Clean Solutions manifolds, M16 x 2 to 1 /4" NPT adapter, use to mount pressure gauge to test point P56279 Pressure Gauge, -16 psi / 113 kpa / 11. bar For Clean Solutions manifolds, stem mount, 21/2" diameter, use with P56389 adapter 24 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
25 Accessories SAMPLING TOOLS Part Number Description Application P Upstream Sampling Port Adapter For single, dual heads, and hp heads, SAE-4, use with P for sampling P Upstream Indicator Port Adapter For single, dual heads, and hp heads, SAE-4, use with P for sampling P Test Point Heads and Manifolds For all Clean Solutions manifolds, 1 / 8" NPT to M16 x 2 P Test Point For all Clean Solutions heads and manifolds, SAE-4 to M16 x 2, use with P and P adapters P56325 Test Point Hose Assembly, 12" P Test Point Hose Assembly, 24" 162 series M16 x 2 thread, for use with P and P mini mess test points 162 series M16 x 2 thread, for use with P and P mini mess test points TEST KIT Part Number Description Application X9329 Patch Test Kit Test kit for measuring fluid cleanliness P Micron Membrane Filter Spares for Patch Test Kit, purchase in multiples of 1 P Micron Membrane Filter Spares for Patch Test Kit, purchase in multiples of 1 P Analysis Cards Spares for Patch Test Kit, purchase in multiples of 5 P ml Sample Bottle Spare for Patch Test Kit Accessories vary by geographical region. Consult your local Donaldson representative for more information. donaldsonfilters.com Clean Fuel & Lubricant Solutions 25
26 System and Sizing The Importance of Temperature in Sizing Your Filtration System Fluid viscosity, measured in centistokes () or Saybolt Seconds Universal (SSU or SUS), is the resistance of a fluid to flow (thickness of fluid). Low viscosity fluids pass through filters with less resistance than high viscosity fluids. Higher fluid viscosities have higher pressure drops due to higher resistance passing through the media. The colder the fluid, the higher the viscosity, so the lowest potential temperature of the fluid during filtration is the best measure for sizing a bulk filtration system. Due to the high specific heat capacity of fluids, the lowest ambient temperature may not be an accurate reflection of the actual fluid temperature. Avoid oversizing your system by using the stored fluid temperature and not the lowest ambient temperature, which tends to be lower than the temperature of the fluid in storage or transport. WATER HONEY Temperature greatly impacts fluid viscosity. Consider that ISO 32 oil at 14 F / 4 C has the same viscosity as diesel fuel (similar to water). When temperatures drop to -4 F / -2 C, the viscosity of that ISO 32 oil increases dramatically to over 2, centistokes, which is similar to honey at room temperature. FUEL/OIL KINEMATIC VISCOSITY COMBINED WITH TEMPERATURE IN CENTISTOKES CST SAE Gear Oil 75W 8W 85W 9 14 SAE Engine Oil 5W 1W ISO Grade F C Diesel , ,29 1,98 3, ,19 1,92 3,7 4,87 8, ,2 1,72 2,99 5,6 8,4 13,9 23, ,5 2,77 4,88 8,89 15,7 27,2 47, 85, ,35 4,65 91,2 16,8 32,3 6, 26 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
27 System and Sizing Bulk filtration systems must be designed properly to meet the desired ISO cleanliness code while maintaining the existing flow rates. The filter type and quantity of filters varies based on the desired cleanliness, system pressure and flow rate. Increasing the flow rate will increase the pressure drop across a filter. If the pressure drop is too high, system flow rate can be reduced or damage to the filter can occur. To reduce the pressure drop, increase the number of filters in the system. The chart below demonstrates the pressure drop experienced by a filter with various viscosities and flow rates. The steeper the pressure drop curve, the more filters that must be added to the system. Additional filters plumbed in parallel will decrease the flow rate per filter, lowering the pressure drop and allowing existing flow rates to be maintained. Fuel Filter DBB Heavy Oil Filter More 2.4 Filters Less Filters il Filter donaldsonfilters.com DBB248 - Water Absorbing Filter Clean Fuel & Lubricant Solutions 27
28 System and Sizing Steps to Sizing a Bulk Application 1Define product flow rate, fluid type and pressure drop restriction. New systems should ideally have less than 15 psi / 1 bar pressure drop. Use the table on the page 26 to determine fluid viscosity using the fluid 2type and temperature. INFORMATION GATHERING FLOW RATE: FLUID TYPE: PRESSURE DROP: TEMPERATURE: 28 Clean Fuel & Lubricant Solutions MyCleanDiesel.com
29 System and Sizing 3 4 Select the appropriate filter based on desired ISO cleanliness code and working pressure (see pages 1 and 11). Determine the filter pressure drop using the flow rate and the fluid viscosity according to the appropriate chart on pages Add the manifold pressure drop using the flow rate on page 15 to calculate total pressure drop. You Don t Need To Do It Alone. Let a Donaldson specialist assist you by providing recommendations on sizing, selection and positioning of Donaldson filters. You can help us design your system by providing: Responses to steps 1-4 above. A schematic of your fluid transfer process (hand sketches work great), and/or Divide total pressure drop through one filter by the desired system pressure drop. This number is equal to the amount of filter required to clean the fluid properly at the determined flow rate. If the pressure drop is more than 15 psi / 1 bar, go up one size. CALCULATED PRESSURE DROP DESIRED PRESSURE DROP = Photographs of your site (tanks, inlets and outlets). Just call to get started. donaldsonfilters.com Clean Fuel & Lubricant Solutions 29
30 Flow Rates and Pressure Drops Flow Rates and Pressure Drops1.5 Pressure Pressure Drop Drop (PSI) (PSI) Pressure Pressure Pressure Drop Drop (PSI) Drop (PSI) (PSI) Pressure Pressure Pressure Pressure Drop Drop Drop (PSI) (PSI) (PSI) Drop (PSI) FUEL AND WATER ABSORBING FILTERS DBB5333 DBB Compact Winter Fuel Fuel Filter Filter DBB Winter Fuel Filter FlowRate Rate (LPM) (LPM) (Diesel) (Diesel) DBB Compact Winter Fuel Filter DBB8664 Flow Rate Heavy (LPM) DBB7733 DBB Compact - Light Winter Oil Oil Filter Fuel Filter Filter Flow Flow Rate Rate (LPM) (LPM) (Diesel) (Diesel) (Diesel) 2 (Diesel) Flow Flow Rate Rate (GPM) (GPM) Pressure Pressure Drop Drop (BAR) (BAR) Pressure Pressure Drop Drop (BAR) (BAR) Pressure Drop (BAR) Pressure Drop Drop (BAR) (BAR) Donaldson Donaldson Company, Company, Inc. Inc. Pressure Pressure Drop Drop (PSI) (PSI) Pressure Pressure Drop Drop (PSI) (PSI) Drop (PSI) (Diesel) DBB8664 DBB Heavy Fuel Filter Oil Filter DBB8665 DBB Light - Fuel Oil Filter Filter Flow Flow Rate Rate (LPM) (LPM) Flow Flow Rate Rate (LPM) (LPM) (Diesel) Flow 3 3 Rate (GPM) Flow Flow Rate Rate (GPM) Flow Flow Rate Rate (LPM) (LPM) DBB248 DBB Water Winter Absorbing Fuel Filter Filter (Diesel) (Diesel) 3 (Diesel) Pressure Pressure Drop Drop (BAR) (BAR) Inc (Diesel) Pressure Drop (BAR) Donaldson Company, Inc t Pressure Pressure Drop Drop (PSI) (PSI) 5 Flow 1 Rate (LPM) DBB Winter Fuel Filter DBB248 - Water Absorbing Filter (Diesel) 3 (Diesel) Pressure Drop Drop (BAR) (BAR) Donaldson Donaldson Company, Company, Inc. Inc DBB Compact Winter Fuel Filter DBB Fuel Filter 2 Flow Rate 4 (LPM) (Diesel) (Diesel) (Diesel) DBB7733 DBB Compact - Fuel Winter Filter Fuel Filter 3 Clean Fuel & Lubricant Flow Solutions Rate (LPM) MyCleanDiesel.com 2 Flow Rate 4 (LPM)
31 Flow Rates and Pressure Drops Flow Rates and Pressure Drops LUBRICANT FILTERS Pressure Pressure Drop Drop (PSI) Pressure (PSI) Drop (PSI) DBB5333 DBB Compact - Light Oil Fuel Filter P Micron hp Flow Flow Rate Rate (LPM) Flow Flow Rate Rate 8 (GPM) (GPM) DBB Winter Fuel Filter DBB8665 P Light - 4 Micron Oil Filter hp Flow Flow Rate Rate (LPM) (LPM) (Diesel) Flow Rate 8 (GPM) Flow Flow Rate Rate (GPM) (GPM) DBB Compact Winter Fuel Filter DBB8777 hp Filters - Fuel 32 Filter * P Flow Rate (LPM) Micron hp P P P (Diesel) (Diesel) (Diesel). 4 Flow Rate 8 (GPM) DBB Compact Winter Fuel Filter 2 Micron hp donaldsonfilters.com Pressure Drop Drop (BAR) Pressure Drop Drop (BAR) (BAR) Donaldson Donaldson Company, Company, Inc. Inc. Donaldson Donaldson Company, Company, Inc. Inc. Pressure Drop (BAR) Donaldson Donaldson Company, Company, Inc. Inc. Pressure Pressure Drop Drop (PSI) (PSI) Pressure Pressure Drop Drop (PSI) (PSI) DBB248 DBB Water - Heavy Absorbing Oil Filter Filter P Micron hp (Diesel) Flow Rate (GPM) DBB Fuel Filter DBB248 P Water - 8 Absorbing Micron hp Filter 2 Micron hp Flow Flow Rate Rate (LPM) (LPM) (Diesel) (Diesel) Flow Rate 8 (GPM) P DBB Fuel Micron Filter hp hp 32 * (Diesel) Pressure Pressure Pressure Drop Drop (BAR) Drop (BAR) (BAR) Clean Fuel & Lubricant Solutions 31 P Pressure Pressure Drop Drop (BAR) (BAR) Donaldson Donaldson Company, Company, Inc. Inc. Inc. Donaldson Company, Company, Inc. Inc
32 Global Presence with a Local Touch At Donaldson, we ve built a strong, flexible and responsive distribution network to serve our customers around the world. Localized Manufacturing It starts with 3+ manufacturing locations around the world producing most filters in the regions where they re used. Primary Distribution Centers Filters then move to our regional warehouses and distribution center hubs meaning the filters you need are never far away. Logistics We work with a network of transportation and logistics companies, consolidators and cross-docking facilities to deliver products to distribution partners quickly and efficiently. Distribution Partners We ve built one of the largest, strongest and most responsive distributor networks in the filter industry meaning you can find the filters and support you need, nearly anywhere in the world. Donaldson Company, Inc. Minneapolis, MN USA (USA/Canada) MyCleanDiesel.com donaldsonfilters.com Need a Clean Solution? As a global organization, we have offices throughout the world. Please direct your inquiry to [email protected]. This will enable us to address your inquiry in the shortest possible time. Mexico Latin America Caribbean Brazil Europe & Middle East South Africa South East Asia Greater China Japan Korea Australia India Brochure No. F1115 ENG (1/15) 215 Donaldson Company, Inc. All rights reserved. Donaldson Company, Inc. reserves the right to change or discontinue any model or specification at any time and without notice. Printed in the U.S.A.
Donaldson Delivers Clean Fuel Solutions Clean Diesel Kits. What is dirty diesel costing you? Achieve More.
Donaldson Delivers Clean Fuel Solutions Clean Diesel Kits What is dirty diesel costing you? Achieve More. Dirty Diesel......And the Damage It Can Do Dirty diesel means costly downtime 30,000 PSI! The diesel
NORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
CSD WATER REMOVAL FILTERS FOR DIESEL
CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve
Compressed Air Filters
Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems
185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008
What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008 This is a seemingly simple question with seemingly simple answers. The problem however is because
Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.
APPLICATION RETURN LINE FILTERS Series RF & RFD Pressures to 36 PSI Flows to 3 GPM HYDAC RF and RFD In-Tank Return Line Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
Selective Catalytic Reduction (SCR) and Diesel Exhaust Fluid (DEF) Training Module
Selective Catalytic Reduction (SCR) and Diesel Exhaust Fluid (DEF) Training Module DEF SCR Training Module Welcome to the Cummins Filtration DEF SCR training module. DEF & SCR systems are key to Cummins
ThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
Diesel Exhaust Fluid (DEF) Q & A
Diesel Exhaust Fluid (DEF) Q & A BULLETIN SCR: The Leading Technology to Meet 2010 Emission Regulations Q. What is Selective Catalytic Reduction (SCR)? A. SCR is a technology that uses a urea based diesel
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
AIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Keeping contamination under control.
Keeping contamination under control. TM Des-Case Corporation Pioneers in contamination control. Why do the world s leading companies, distributors, and OEMs look to Des-Case? Because we understand the
Improving Diesel Engine Life:
Improving Diesel Engine Life: Fuel Filtration to Clean Up the Diesel Industry www.filterelement.com ISO 9000 Certified The Problem - Diesel engines have made incredible progress in recent decades. Along
Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
AIR OPERATED OIL PUMPS AND KITS
PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model
Midwest Industrial Tanks
FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers
PVS Series - Models 185, 600, 1200, 1800 and 2700
PVS Series - Models 185, 600, 1200, 1800 and 2700 Reduce the catastrophic results of water contamination Eliminate water from the hydraulic system The PVS Series Portable Purification Systems, available
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide
Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:
E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
Basic Hydraulics and Pneumatics
Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
Dryaire Desiccant System
Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance
15/40/80CN Series Coreless Medium Pressure Filters
//8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot
Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice
Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
DEF Q&A. A. SCR is a technology that uses a urea based diesel exhaust fluid (DEF) and a
Selective Catalytic Reduction (SCR) Q. What is Selective Catalytic Reduction (SCR)? A. SCR is a technology that uses a urea based diesel exhaust fluid (DEF) and a catalytic converter to significantly reduce
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
ThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)
6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012) Fuel contamination on 6.7L diesel engines can damage fuel system components including the High Pressure
Lubricant Transfer, Storage & Dispensing
Lubricant Transfer, Storage & Dispensing WHY USE OIL SAFE TRANSFER CONTAINERS? OIL SAFE - TRANSFER CONTAINERS For more than a decade, OIL SAFE has been the oil transfer manage- The color-coded range of
Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
Atlas Copco Quality Air Solutions. Compressed Air Filters
Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational
Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions
795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
08.08 Vic-Check Valves
The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc
*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
LT Series Lubricant Management System (LT-LMS)
FLUID HNDLING: LT Series Lubricant Management System (LT-LMS) This system combines filtration, storage, and breathers in one simple solution to keep your lubricants clean and dry. The Overview The LT-LMS:
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
SMR Series Submicronic Removal Fluid Purifi cation Systems
SMR Series Submicronic Removal Fluid Purifi cation Systems 193 SMR Series Applications The SMR Series is the smart purification solution for fluid flow in the 2-10 GPM (8-38 LPM) range. The SMR contains
MFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division
Caterpillar Inc. Cat Marine Power Diesel fuel feature story 187-P-2-004-98 Special to Seaway Review HEADLINE: BYLINE: Fuel for Thought David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products
Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal
Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + removal Diesel PreCare: The Clear Link Guaranteed HYDAC quality thanks to HYDAC Quality
Hydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
Pumping Fuel & Fuel Oil
Pumping Fuel & Fuel Oil Fuels & Rotary Pumps Though the handling of fuel oil is not necessarily "challenging," the reliable handling of fuel oils is critical for heating and transportation systems. Rotary
Master Catalogue I August 2011
Master Catalogue I August 2011 Greasing Equipment Drum Pumps Hose Reels Vehicle Hoists Wheel Service Equipment Lubrication Systems 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile
Bulk System Gallery. Bulk Storage Systems. OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget.
Bulk System Gallery OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget. If you don t see a bulk storage solution that meets your lubricant management challenges
Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...
Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments
Cubetainer The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments Providing Bulk Storage Solutions for Motor Oil, Lubricants, Hydraulic Fluids, ATF, Antifreeze & DEF www.snydercubetainer.com
Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors
s Control Analysis Fabrication A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors Eductors Ensure Thorough Mixing to Improve Product Quality and Reduce Maintenance Time Tank mixing eductors
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
How To Make A Fuel Manager Filter/Separator
The Versatile Diesel Fuel Filtration/Water Separator System From America s Foremost Diesel Technology Innovator STANADYNE The Versatile Fuel Filtration System FOR EVERY DIESEL ENGINE, EVERY DIESEL APPLICATION
OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br
OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter
Pipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
Check Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Oil Sight Glass BENEFITS
8 L-4090 Schroeder es provide maintenance and lubrication management professionals a complete and immediate visual oil analysis. Constructed of durable cast acrylic, they withstand most petroleum products
Oil Analysis. It is important that the sampling be done in the following manner: 1.
Oil Analysis Introduction Oil analysis was originally used by the military and the railroad as a preventative maintenance program. It has expanded today to the fi eld of study called Tribology. Oil analysis
TIMER CONTROLLED DRAINS
TIMER CONTROLLED DRAINS FLUIDRAIN EZ-1 TEC-11 TEC-44 QUICK-SET D-LUX HIGH PRESSURE ENVIRONMENT DRAIN FLEXIBILITY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS 190602_Timer_Drains_catalogus_2014.indd
The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700
Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700 www.comoso.com 190 800.696.6165 PVS Series Principles of Operation Contaminated oil is drawn into the Parker Portable Purification System
Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement
Program Summary Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement 2 Table of content Content Fluid & Motion Control 3 Directional Control Valves, solenoid operated 4 Directional
Ultipleat High Flow Filter System
Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.
Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators
Atlas Copco On-site Industrial Gases Nitrogen & Oxygen Generators A secure supply of nitrogen and oxygen Whether your company is specialized in chemical manufacturing, electronics, laser cutting or food
VSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
Used Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT
e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation
Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow
Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where