Sentinel Portable Purification System

Similar documents
GreenMAX. Heavy-Duty, High-Capacity, Fuel Filter/Water Separator With Options for All-Weather Operations

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS Series - Models 185, 600, 1200, 1800 and 2700

GreenMAX. Heavy-Duty, High-Capacity, Fuel Filter/Water Separator With Options for All-Weather Operations

DHA & DBA Series. Heat Reactivated Desiccant Dryers

Airtek TW Series. Heatless Desiccant Air Dryers

Drinking Water Filtration for Parker Facilities

Medical Grade Breathing and Surgical Air

Coreless Spin-On Filters. 12AS/50AS Series

Vacuum Dehydration Oil Purification System (VDOPS)

Medical Air Systems: Scroll

SMR Series Submicronic Removal Fluid Purifi cation Systems

Air Eliminators and Combination Air Eliminators Strainers

Kompressoren. Adsorption Dryer AD

HYDROSTATIC TEST PUMPS

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

CSD WATER REMOVAL FILTERS FOR DIESEL

15/40/80CN Series Coreless Medium Pressure Filters

Model 1210C Battery Powered Pump Shown. Description

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Your oil can be saved!! Even when water is mixed

DIESEL FUEL CONDITIONING

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

MOLECULAR DRAG PUMPS MDP SERIES

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

6 Crankcase Ventilation

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Adsorption air dryers ADS 1 215

Filters for the Natural Gas Industry. Bulletin NG/USA Rev A

High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS)

Diesel Fuel Filtration

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

300 Series PA Pump and Cooler Assemblies

ThermoSorb Desiccant Dryers

Compressed Air Filters

Waste Oil Handling, Spill Containment & Lighting

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Conlift1, Conlift2, Conlift2 ph+

CONTINUOUS FLOW BREATHING AIR PURIFIERS

AIR OPERATED OIL PUMPS AND KITS

Parker FARR Filtration Introduction

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Rotary screw compressors kw 5,5 7, , bar MODULO

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

Desiccant Air Dryers Heatless, Heated and Heated Blower

Technical Specification. Generating Set with Waukesha engine burning natural gas

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Automatic Back-Flushing Filter AutoFilt RF9.

FEATURES PRODUCT SERIES IP5000/IP5100 HIGH PERFORMANCE POSITIONER COMPACT AND LIGHTWEIGHT RESISTANT TO HOSTILE ENVIRONMENTS DESIGNED TO IP55, NEMA 4

TRANSLATION OF THE ORIGINAL MANUAL

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

400B SERIES DIAPHRAGM PUMP

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Atlas Copco Quality Air Solutions. Compressed Air Filters

C18 ACERT Fire Pump Tier bkw/ rpm

PUMP AND MOTOR DIVISION

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

KNC Model 3666 Automatic Pressure Calibration System

Keeping contamination under control.

15/40/80CN Series Medium Pressure Filters

SanStar Series SSi and SSO Mixers SANITARY MIXERS

LT Series Lubricant Management System (LT-LMS)

Flex separation systems, S-separators

Refrigeration Compressed Air Dryer Buran Ultrapulse

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Centro-Matic Automatic Lubrication Systems System Controls

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Pro Dry Heatless dessiccant compressed air dryers

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Clinic Washer-Disinfectors. Washer-Disinfector Line

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ThermoStar Refrigeration Air Dryers

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Ultra-Filter. Compressed Air Filter. DF Series

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

LINEAR MOTION CONTROL

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

Power consumption (kw)

LEISTRITZ PUMPEN GMBH. Leistritz Screw Pumps & Systems. Cargo and Liquid Handling

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Series TMM Axial Piston Motor. Technical Information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

Sentinel Portable Purification System

Smaller foot print Greater value Improved efficiency New circuitry Patent pending 2

Sentinel Delivering big results in a compact, lightweight package, the Sentinel is the latest in fluid purification technology from Parker. The system guards over mission critical hydraulic and lubrication systems to effectively attack water, solids and gases while improving equipment health, productivity and reliability. The smallest in Parker s family of oil purifiers, the Sentinel s unattended automatic operation minimizes energy consumption while extending the usable life of fluids. Equipped with Parker s IQAN MD3 platform control system, the Sentinel provides user confidence in system monitoring while delivering maximum performance on demand. The Sentinel removes both free and dissolved water contamination from hydraulic fluids. Automotive Plastic Injection Molding Lubrication Systems Petrochemical Lubrication Systems Process Controls Power Generation Electrohydraulic Control Systems Aerospace Ground Support Equipment Test Stands Marine Propulsion, Steering Systems Thrusters Mining Lubrication Systems 3

Features and Benefits Compact Size Will fit through small doorways Makes marine applications possible Automatic Operation Unattended use Reduces labor costs Increases operation time Desiccant Breather Provides dry, clean air intake More efficient operation 316 Stainless Steel Used for primary wetted surfaces No corrosion Product reliability Reverse Phase Switch Enables easy change of motor rotation if out of phase Ease of maintenance Prevents incorrect rotation The Sentinel is designed for applications when space is at a premium. Ecoglass Particulate Element Coreless, non-metallic construction Environmentally friendly, easy disposal Diffusion Head/ Manifold Flexibility with various fluid viscosities Excellent moisture removal efficiency Forklift Guides/ Lifting Eyes Safe and secure method of lifting Employee safety 4

Principles of Operation Vacuum Gauge Coalescing Filter Contaminated fluid is drawn through the Sentinel circuit by vacuum. The fluid is subjected to optimum vacuum, temperature and surface area to reduce the boiling point of water and convert water to water vapor. Optimum temperature is achieved with a low watt density heater. Maximum surface area is accomplished by passing the fluid through a unique diffusing column. Desiccant Air Breather High Level Switch Low Level Switch Flow Direction Low Watt Density Heater Vacuum Chamber Overflow Tank Inlet Flow High Level Overflow Reservoir The fluid is protected from excessive heat by circulation for a fixed time period. When the pre-set time period is realized, the fluid discharges through high efficiency filtration to the main system reservoir. Water vapor that has been extracted from the system is exposed to a series of coalescers to eliminate any carryover oil vapor in the exhaust stream. Oil Discharge Pump Model 40CN-2 Absolute Filter Dry Sealed Vacuum Pump Oil Lubricator High Level Condensate Condensate Tank Vacuum Outlet Condensate Drain The process repeats until the desired steady state condition is achieved. Water is one of the most common contaminants in a fluid system and one of the most damaging. 5

The operator can customize set points for various applications within their facility. IQAN System One of the highlights of the new Sentinel unit is the addition of Parker s IQAN system. The IQAN is an electronic PLC interface that controls many of the operating functions on the Sentinel. With IQAN, the operator can customize set points for various applications within their facility. Some of the user defined set points are: sample rate moisture high limit moisture set point (low limit) temperature vacuum purge cycle auto condensate drain energy conserving features Sentinel mode will maintain constant dedicated vigilance to control water saturation in fluid while providing energy and labor savings. Three modes of operation 1Standard Conventional purifiers require that the reservoir fluid be at 150 F before efficient water removal occurs. This could take hours if the ambient temperatures are low and the reservoir volumes are large. Standard mode allows for less power consumption by drawing the fluid through the unit in a unique cyclic method. The fluid is drawn into the unit and held while heat and vacuum act on it to remove water. Every two minutes the fluid is discharged and the process repeats, conserving power that otherwise would be necessary to bring the entire main system reservoir to the required 150 F. 2Sentinel Sentinel mode acts the same as standard mode other than it samples by drawing in fluid from the reservoir and testing the water saturation point. If the level is less than the desired set point, the system will hibernate until the next sampling point. The minimum time between sampling is 20 minutes and the maximum is 12 hours. 3 Sample Once started, three batches of hydraulic fluid will be drawn into the system where overall moisture level and temperature are averaged and displayed on the IQAN screen. 6

Specifications Flow Rate 5 gpm (18.9 lpm) Dimensions 45" H x 19.5 W x 24 L (1143mm x 495mm x 686mm) Weight 440 lbs. (200 kg) Seal material Fluorocarbon Condensate tank.5 gal (1.9 ltrs) Dispersal elements 1 Minimum operating capacity 5 gal (18.9 ltrs) Vacuum (max) 24 In/Hg Viscosity (max) 500 SUS (108 cst)-disposable 2150 SUS (460 cst)-packed Tower Outlet pressure (max) 60 psi (4.1 bar) Ports 3/4" JIC (male) inlet 3/4 JIC (male) outlet FLA (full load amps) 16 amps @ 480VAC Shipping Weight 640 lbs. (290 kg) maximum Shipping Dimensions 56 H x 37 W x 37 L (1422mm x 940mm x 940mm) Electrical Requirements: 230VAC, 3P, 50Hz 380VAC, 3P, 50Hz 415VAC, 3P, 50Hz 460VAC, 3P, 60Hz Electrical Connection Port: NEMA L16-30P Flanged Inlet Hydraulic Connections: Inlet: JIC 12 Outlet: JIC 12 Max Flow: 5 GPM Water Drain: JIC 8 Vacuum Exhaust Port: JIC 8 Max Pressure: 60 psi (gauge) Vibration: Band 1: 900 hz.5 g*g/hz Storage: Max Temp 180 F, 100% rh Main Power IQAN Control Phase Reversal 24.4 (619 mm) 19.5 (495 mm) Hydraulic Outlet 4 Point Tie Down Rings 45.2 (1148 mm) Vacuum Exhaust Hydraulic Inlet Electrical Connection Port Water Drain 1/2 NPT Cabinet Drain Fork Truck Support Pocket Note: Dimensions and weights are approximate and are for reference only. 7

Performance Potential Contaminant Solid particulate Water Air/Gases Sentinel Performance ISO Cleanliness Code 14/13/10 Attainable Removes 100% of free water, 90% of dissolved water Removes 100% of free air and gases, 90% of dissolved air and gases Typical Performance Tank Size 55 gallon test drum Run Time 16 hours Fluid Type Hydraulic Start: 7,000+ ppm (1%) Water Content Saturation pt: 5,000 ppm Stop: 200 ppm (0.005%) 40 Water Removal Time 5000 ppm (.5%) to 150 ppm (.015%) 35 30 Total Hours 25 20 15 10 5 0 0 100 200 300 400 500 600 700 800 900 1000 Reservoir Size (Gallons) Time vs. Reservoir Moisture 600 500 Reservoir Moisture (ppm) 400 300 200 100 0 20 40 60 80 100 120 140 Time (min) 8

Ordering Part Number Description Standard Unit 943116* 380VAC, 3P, 50Hz 943118* 230VAC, 3P, 50Hz 943213* 460VAC, 3P, 60Hz 943401* 415VAC, 3P, 50Hz Optional Accessories 943236 Mounting Bracket Kit 943238 Cordset (pigtail end) * Standard unit includes Dry sealed vacuum pump Coalescing filter 5 micron Ecoglass III element 6KW 3 phase low watt density heater 3 diameter rubber-wheel casters Consult factory for other options Service Parts 936711Q 943237 Hydraulic Particulate Element Service Kit (includes TriCeptor air breather, hydraulic particulate element, coalescing element, vacuum pump oil and vacuum pump filter element) 20072409 IQAN MD3 B-10235-0-460 B-10235-0-380 B-10235-0-230 CEM3546T 06F20C2218A1FPH80 Heater 460VAC Heater 380VAC Heater 230VAC Hydraulic Pump Motor Condensate Drain Valve 00424 Float Switch MPS-V33N-PGAT Vacuum Sensor 2820008 Pressure Sensor 40CN205QEVE2GS164 MS1504 Filter Moisture Sensor 3349116565 Gear Pump 9

Total System Health Management Diagnostic Therapeutic Preventive When an issue is diagnosed, which goes beyond your standard preventive measures, the Sentinel can be just the therapy your system needs. Sentinel 10

Sentinel Specification Worksheet Customer Name & Address: Market & Application (i.e. Power Gen/Turbine Lube) Fluid Type: Brand: Grade: Viscosity: Min: SUS/cSt @ F Max: SUS/cSt @ F Normal: SUS/cSt @ F Critical Hydraulic Component Types: (Check all that apply) Servo Valves Proportional Valves Vane and piston pumps/motors Gear pumps/motors Directional & pressure control valves Flow control valves Water concentration: Current % of water Desired % of water Sentinel/PVS location related to reservoir (reservoir above or below ground level & distance) 0-5 meters 5-10 meters 10 meters System fluid operating temperature: F/ C Voltage options: 230 VAC, 3P 60Hz 380 VAC, 3P 50Hz 460 VAC, 3P 60Hz 415 VAC, 3P 50Hz System Volume: 0-1000 gal - Sentinel or PVS185 1000-3000 gal - PVS600 3000-7000 gal 7000-9000 gal >9000 gal Any previous filtration problems with the application? Gelling High contamination levels High ambient environment PVS model selected: Parker Hannifin Corporation Hydraulic Filter Division 16810 Fulton County Road #2 Metamora, OH 43540 phone 419 644 4311 www.parker.com/hydraulicfilter 11

Worldwide Filtration Manufacturing Locations North America Compressed Air Treatment Filtration & Separation/Balston Haverhill, MA 978 858 0505 www.parker.com/balston Finite Airtek Filtration Airtek/domnick hunter/zander Lancaster, NY 716 686 6400 www.parker.com/faf Finite Airtek Filtration/Finite Oxford, MI 248 628 6400 www.parker.com/finitefilter Engine Filtration & Water Purification Racor Modesto, CA 209 521 7860 www.parker.com/racor Holly Springs, MS 662 252 2656 www.parker.com/racor Beaufort, SC 843 846 3200 www.parker.com/racor Racor Village Marine Tec. Gardena, CA 310 516 9911 desalination.parker.com Parker Sea Recovery Carson, CA 310 637 3400 www.searecovery.com Hydraulic Filtration Hydraulic Filter Metamora, OH 419 644 4311 www.parker.com/hydraulicfilter Laval, QC Canada 450 629 9594 www.parkerfarr.com Process Filtration domnick hunter Process Filtration Oxnard, CA 805 604 3400 www.parker.com/processfiltration Madison, WI 608 824 0500 www.scilog.com Phoenixville, PA 610 933 1600 www.parker.com/processfiltration Aerospace Filtration Velcon Filtration Colorado Springs, CO 719 531 5855 www.velcon.com Europe Compressed Air Treatment domnick hunter Filtration & Separation Gateshead, England +44 (0) 191 402 9000 www.parker.com/dhfns Parker Gas Separations Etten-Leur, Netherlands +31 76 508 5300 www.parker.com/dhfns Hiross Zander Padova Business Unit Padova, Italy +39 049 9712 111 www.parker.com/hzd Hiross Zander Essen Business Unit Essen, Germany +49 2054 9340 www.parker.com/hzd Engine Filtration & Water Purification Racor Dewsbury, England +44 (0) 1924 487 000 www.parker.com/rfde Racor Research & Development Stuttgart, Germany +49 (0)711 7071 290-10 www.parker.com/rfde Hydraulic Filtration Hydraulic Filter Arnhem, Holland +31 26 3760376 www.parker.com/hfde Urjala Operation Urjala, Finland +358 20 753 2500 www.parker.com/hfde Condition Monitoring Centre Norfolk, England +44 (0) 1842 763 299 www.parker.com/hfde Parker Kittiwake West Sussex, England +44 (0) 1903 731 470 www.kittiwake.com Parker Procal Peterborough, England +44 (0) 1733 232 495 www.kittiwake.com Process Filtration domnick hunter Process Filtration Birtley, England +44 (0) 191 410 5121 www.parker.com/processfiltration Parker Twin Filter BV Zaandam, Netherlands +31(0)75 655 50 00 www.twinfilter.com Asia Pacific Australia Castle Hill, Australia +61 2 9634 7777 www.parker.com/australia China Shanghai, China +86 21 5031 2525 www.parker.com/china India Navi Mumbai, India +91 22 651 370 8185 www.parker.com/india Parker Fowler Bangalore, India +91 80 2783 6794 www.johnfowlerindia.com Japan Tokyo, Japan +81 45 870 1522 www.parker.com/japan Parker Techno Osaka, Japan +81 66 340 1600 www.techno.taiyo-ltd.co.jp Korea Hwaseon-City +82 31 359 0852 www.parker.com/korea Singapore Jurong Town, Singapore +65 6887 6300 www.parker.com/singapore Thailand Bangkok, Thailand +66 2186 7000 www.parker.com/thailand Latin America Parker Comercio Ltda. Filtration Division Sao Paulo, Brazil +55 12 4009 3500 www.parker.com/br Pan American Division Miami, FL 305 470 8800 www.parker.com/panam Africa Aeroport Kempton Park, South Africa +27 11 9610700 www.parker.com/africa 2013 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies. Catalog 2300-850 USA Parker Hannifin Corporation Filtration Group Global Headquarters 6035 Parkland Boulevard Cleveland, OH 44124-4141 phone 216 896 3000 www.parker.com