PRECAST CONCRETE BOX CULVERTS



Similar documents
PRECAST CONCRETE MANHOLES

DIVISION 4300 STORM DRAINAGE

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Section 2100-Trenching and Tunneling

Wastewater Capital Projects Management Standard Construction Specification

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION 7- STORM SEWER

SECTION NONREINFORCED CONCRETE SEWER PIPE

SECTION 5: SANITARY SEWER SYSTEM DESIGN

City of Shelbyville Site Inspection Checklist

SECTION PRECAST CONCRETE UTILITY STRUCTURES

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

ITD Pipe Materials Selection & Specification Procedures. July 2011

Stormwater/Wetland Pond Construction Inspection Checklist

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

PRE INSTALLATION MANUAL

8-11 Structural Analysis and Fill Height Tables Pipe Cover Shallow Cover Installation Fill Height Tables...

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

Flowtite Jacking Pipe

SECTION STORM DRAIN SYSTEM

C. Section TESTING LABORATORY SERVICE.

STORM DRAINS CHAPTER 7

Section 402. STORM SEWERS

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

CITY UTILITIES DESIGN STANDARDS MANUAL

CULVERT AND STORM SEWER PIPE MATERIAL POLICY ON FEDERALLY FUNDED LOCAL AGENCY PROJECTS UPDATED March 2013

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Construction Site Inspection Checklist for OHC By making use of some simple Best Management Practices (BMPs) a construction site operator can

Installation PowerPoint for Grasscrete Formers

Underground Injection Control Storm Water Information

SECTION STORM DRAINAGE SYSTEM

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Beacon Hill Sewer District Standard Specifications

Safe & Sound Bridge Terminology

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

550 PIPE CULVERTS, SEWERS AND DRAINS

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

Use of Corrugated HDPE Products

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

DMS REINFORCED CONCRETE PIPE AND MACHINE-MADE PRECAST CONCRETE BOX CULVERT FABRICATION AND PLANT QUALIFICATION

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

PROJECT COST ESTIMATE ASSUMPTIONS AND EXCLUSIONS

Retaining Wall Global Stability & AASHTO LRFD Unnecessary, Unreasonable Guideline Changes Result in Huge Wastes of Money at Some Wall Locations

STANDARD SPECIFICATIONS & CONSTRUCTION DETAILS MANUAL SECTION 5 - STORM DRAINAGE Design

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

INDEX. Sec. No. Items Page Nos.

The Most Advanced Name in Drainage Systems. Geotextile Products

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

Chapter 4 ASSET INVENTORY AND CONDITION CHAPTER 4 ASSET INVENTORY AND CONDITION PAGE 33

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 9 Storm Sewers

Bridge Type Selection

Access chambers and maintenance shafts. Issue 1

SECTION 724 PIPE CULVERTS

Basics of Reinforced Concrete Design

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

GUIDE SPECIFICATIONS FOR PRECAST CONCRETE PRODUCTS

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

Guide Specification Precast Concrete Products

GUIDE SPECIFICATION FOR PLANT-PRECAST CONCRETE PRODUCTS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

The Verdura Wall check with your local building department

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Minimum Design Criteria for the permitting of Gravity Sewers

3A General Information A. Concepts... 1 B. Conditions... 1

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SECTION REINFORCED CONCRETE PIPE. A. The following is a list of SPECIFICATIONS, which may be related to this section:

Collection Systems Technology Fact Sheet Sewers, Conventional Gravity

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

Proposed Minimum Subterranean Termite Treatment Standards

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

900 SEWERAGE WORK ITEM PIPE SEWERS COMPLETE IN PLACE

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

SECTION GRAVITY SANITARY SEWERS

SPR PE Steel Reinforced Liner

Design of Bridges. Introduction. 3 rd to 4 th July Lecture for SPIN Training at the University of Dar es Salaam

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Transcription:

PRECAST CONCRETE BOX CULVERTS

OUTLINE Introduction Applications Manufacturing Methods Design Procedures & Joints Installation Quality Summary

INTRODUCTION Four-sided culverts are typically referred to as box culverts.

INTRODUCTION Standard box sizes: 3 x 2 to 12 x 12 in 1 span and rise increments. Typically come in 6 and 8 lengths. Custom box sizes: Nonstandard sizing is permissible and must be designed per project design specification.

INTRODUCTION Three-sided structures are U-shaped structures that may or may not have a crown in the center.

INTRODUCTION Standard three-sided structures range from 8 to 48 span lengths. Custom sizes are available and must be designed per project design specifications.

Box culverts Short-span bridges (over highways, waterways, railways, for golf courses, etc.) Conveyance of stormwater, sewage or industrial wastes (storm drains) Tunnels (to house conveyers, utilities, etc; to provide access, escape routes, etc.) Detention APPLICATIONS Three-sided culverts Short-span bridges (flat and arched)

APPLICATIONS Benefits: Box culverts can be made in large sizes to accommodate increased flow rates and capacities. Boxes can be set with 0 feet to 100 feet of cover.

STORMWATER CONVEYANCE Typical small stream crossing.

TUNNELS Fast and economical method for tunnels under roadways, as in this golf cart tunnel.

TUNNEL & ESCAPE ROUTES Provide for emergency egress, as with this tunnel underneath a warehouse and distribution center.

STORMWATER DETENTION Multicell box culvert installation to economically provide storage of storm water runoff.

CUSTOM BOX SIZES Custom designed and manufactured box culverts are available, as with this monolithic triple cell structure.

BENDS CAN BE DESIGNED

MITERS & SIDE OPENINGS

THREE-SIDED STRUCTURES Placed on strip footing and used for short span bridges. They allow for natural stream beds to remain intact and can meet EPA requirements.

THREE-SIDED STRUCTURES Large 3-sided structure w/precast headwalls and wing walls.

SHORT-SPAN BRIDGES Roadway over roadway applications can be accomplished with long-span 3-sided structures.

MANUFACTURING METHODS Wet-Cast Typically cast on end using an inner and outer form. Blockouts / hole formers can easily be incorporated. Cast with conventional concrete or self-consolidating concrete. Product cured in the form. Wet-cast is commonly used for sanitary applications.

MANUFACTURING METHODS Dry-Cast (Machine Made) Product cast using mechanized equipment. Form vibrators consolidate zero-slump concrete between core and jacket. Hole formers may be incorporated, or coring is done as needed. The product is immediately stripped and the form is reused. Products typically cured in a kiln, or a combination of tarps and moisture curing is used. Surface may appear textured due to manufacturing process.

DESIGN Designs are dependent on project specifications and applications. This includes hydraulic design for fluid conveyance structures.

DESIGN Fluid Conveyance Hydraulic design and sizing are usually performed using Manning's n for open channel flow (typical values for n are 0.012 for wet-cast and 0.015 for dry-cast). This work is usually performed by the owner s engineer, who then supplies the precaster with the size requirements.

DESIGN Structural design is performed based on application After determining the size required, use applicable standards for the box or three-sided structure design. This work is usually performed by the precaster or the precaster s engineer.

DESIGN List of common design standards: ASTM C 1433 Box culverts, for conveyance of stormwater, industrial wastes and sewage. ASTM C 1504 Three-sided structures, for stormwater conveyance and culverts. AASHTO Standard Specification for Highway Bridges for short-span bridges.

DESIGN List of common design standards: ACI 318, for tunnels and special design. ACI 350R, for wastewater applications.

DESIGN NOTES Box culverts are subject to: Lateral earth loads from soil and hydrostatic loads from ground water. Vertical loads from the cover soil and live loads above. Surcharge loads from nearby impact loads. Seismic loads where applicable.

DESIGN EXAMPLE Box culvert design for stormwater conveyance Project data: Flow rate, Q = 1000 ft 3 /sec Length, L = 800 feet Initial slope, S o = 0.5% Allowable Head Water, HW = 15 feet Manning's, n= 0.012

DESIGN EXAMPLE After calculations, it was determined that a 9 x 7 box culvert will handle the required flow. The box will support HS20 loads: Use ASTM C 1433. Box to be set at 8 depth, use table 1.

DESIGN EXAMPLE 9 x 7 x 9 Circumferential Reinforcement Areas, in 2 /ft Depth, ft As 1 As 2 As 3 As 4 As 5 As 6 As 7 As 8 M 0<2 0.25 0.58 0.29 2<3 0.25 0.46 0.32 59 3-5 0.28 0.30 54 10 0.25 0.41 0.43 49 15 0.34 0.56 0.59 44 20 0.42 0.72 0.74 44 25 0.51 0.88 0.90 44

DESIGN EXAMPLE

DESIGN EXAMPLE Less than 2 Cover - 9 x 7 x 9 Circumferential Reinforcement Areas, in 2 /ft Depth, ft As 1 As 2 As 3 As 4 As 5 As 6 As 7 As 8 M 0<2 0.25 0.58 0.29 2<3 0.25 0.46 0.32 59 3-5 0.28 0.30 54 10 0.25 0.41 0.43 49 15 0.34 0.56 0.59 44 20 0.42 0.72 0.74 44 25 0.51 0.88 0.90 44

DESIGN EXAMPLE

JOINTS EXTERNAL WRAP ASTM C 877

JOINTS MASTIC/BUTYL ASTM C 990

JOINTS Closed cellular rubber (vinyl & nitrile elastomers). Physical properties of ASTM D1056 Type 2C-1 & chemical resistance requirements of AASHTO M198. Requires a joint gap. Soil tight only.

JOINTS Female (groove) end Male (tongue) end

JOINTS

INSTALLATION Trench must remain dry during the installation process, dewater if necessary. Bedding must be compacted, set to grade and meet specifications. Place groove end section first. Set subsequent boxes with the tongue end being set into the groove to reduce bedding disruption.

INSTALLATION Backfill shall be placed uniformly on each side of the precast concrete box sections. The backfill material to be placed, the percent of compaction, the depth of layers, etc., shall be as required by the contract specifications.

QUALITY When purchasing and specifying box or three-sided precast concrete structures, you should specify certified plants. NPCA Certification program.