IT Cooling Solutions. Wall-Air Series Displacement Evolution. Telecom-Line



Similar documents
STULZ the natural choice. Tel-Air-2 Series. Telecom Line

IT Cooling Solutions. STULZ AirModulator, AirBooster and AirBooster Pro. Air Flow Management for Data Centres

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

Data Centre Cooling: Don't Waste Money on the Wrong Solution

Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology

Monitoring. STULZ The natural choice. Around the clock Around the world

IT Cooling Solutions. CyberAir 2 Precision Cooling Solutions. Making more efficient use of your resources

STULZ View On DataCenter Cooling

IT Cooling Solutions. Precision Cooling Solutions. Maximum efficiency in data centre air conditioning

Free Cooling for Data Centers

Hiwall Hiross for Telecom. High Performance Air Conditioning

Elements of Energy Efficiency in Data Centre Cooling Architecture

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CRAC Precision climate control units for data centres

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

State of the Art Energy Efficient Data Centre Air Conditioning

Zertico Rack Monitoring Unit

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

ECOCIAT. Domestic hot water heat recovery unit

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

EHDC. Cooling system for Data Center and server cabinets.

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

IntesisBox KNX LG Air Conditioning

Chilled Water Precision Air Conditioner For Critical Application

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

JAWAHARLAL NEHRU UNIVERSITY

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Energy Efficiency and Intelligent Store Solutions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Legacy Data Centres Upgrading the cooling capabilities What are the options?

BUSINESS UNIT ELECTRONICS Electronic Locking, Control and Monitoring

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Unico Inverter. Unique and efficient.

Master & Amplifier For ModuSat Communal Heating

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

york air-conditioning products Residential & VRF News 2015

PORTABLE AIR CONDITIONER

How To Make A Fronius Cl Power Inverter

MPR-Systems. Mini Power Racks 1200 W W

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

saving energy in comfort Factsheet Recair Enthalpy

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Phase Modular Finally the benefits of Modular ups are for all

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

Natural gas heating versus split system heating and the current and future viability of the Natural gas network

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Direct Fresh Air Free Cooling of Data Centres

CompTrol INDEX 50 Edition 5.97 AIRCONDITIONING MICROPROCESSOR TECHNICAL MANUAL

Split units TH with hermetic compressors

Single Zone LCD Thermostat Operating Instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

News in Data Center Cooling

flexotron 800: Electronic ventilation, air-conditioning and heating controller

Freezers - Ultrafreezers. Platilab & Irilab Series

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

Dräger X-dock Release Notes Software-Update and Manager Software 1.7.0

Incubator with mechanical convection

Electronic Control Devices The European Product Catalogue 2007

For every mission, there is a Vector. VECTOR

SMM. Installation Operation Maintenance

Technical Specifications for West Campus Data Center HVAC System

Daikin Altherma hybrid heat pump. The natural combination

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Air conditioners Heating & Cooling

Temperature & Humidity SMS Alert Controller

Technical data. Danfoss DHP-A

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Powerline 1200 User Manual

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Product overview Air conditioning service units

Transcription:

IT Cooling Solutions Wall-Air Series Displacement Evolution Telecom-Line

STULZ precision air conditioners for outdoor installation the Wall-Air Advanced WDE series With its Telecom Line, STULZ offers a range of professional air-conditioning solutions for the telecommunications infrastructure and for switch cabinets. All units are designed for 24/7 operation, 365 days a year, and offer maximum reliability and availability. In the unlikely event that a problem does arise, STULZ's network of competent partners and branches guarantees fast, trouble-free service. Annual energy consumption (kwh) Up to 93 % energy savings with mixed mode 1,000 800 600 400 100% 200-12 0 14 32 Outside temperature ( C) 7% Energy consumption with the use of free cooling and mixed mode Energy consumption without free cooling, using the example of a WLD 60, based on the temperature profile of the city of Hamburg 2

In telecommunications containers, space is at a premium. Wall-Air Advanced WDE units are installed outside the container, therefore enabling the space inside the container to be used to the full. The basic unit comes with cooling and microprocessor control. The performance spectrum of the series can be considerably extended by various optional extras, providing solutions for individual requirements. Technical features of the Wall-Air Advanced WDE series Energy-saving operation thanks to proportional free cooling facility Condenser with Microchannel technology C2020 microprocessor control Automatic restart after power failure Speed-controlled condenser and evaporator fan 48V DC backup operation Contacts for various alarm signals for connection to a monitoring system Refrigerant R407C Mixed mode for energy-saving operation Wall-Air Displacement Advanced WDE Displacement principle Displacement units blow out the cold air close to the ground at low speed (< 1 m/s). Due to the low speed at which the air is flowing, a "pool" of cold air forms on the floor. This cold air is drawn in by fans integrated in the server rack as a function of the heat load, and the heated air is then expelled upwards. Because this method prevents hot and cold air from mixing, the displacement unit can draw in the air at 30 C, instead of at 25 C as was previously the case. The enlarged temperature spread enables the displacement units to work more quietly and efficiently. Free cooling At low outside temperatures, cooling is direct with outside air. The outside air is conveyed into the container when the air flap is open. Therefore, when outside temperatures are low, energy-intensive compressor cooling is not necessary. Mixed mode Once the outside temperature exceeds a given threshold, free cooling alone is no longer sufficient. Then, in mixed mode, the runtimes of the compressor are kept to a minimum by the simultaneous use of free cooling and compressor cooling. In this way, depending on the local temperature profile, the annual energy costs can be cut by a further 10 %. The partial load mode of the air conditioner produces further potential savings. 3

The low-noise solution: Wall-Air Displacement Advanced WDE Technical features Options Displacement principle for quiet running Outside air conditions -20/+50 C winter/summer G4 zigzag filter Night mode Sequencing operation High temperature operation up to 55 C with R134a Compressor soft start Electric heating Aluminium housing Serial interface RS485 for connection to BMS systems Electrical cables ready to plug in Winter kit up to -40 C External operator terminal for C2020 Humidity sensor Installation example Free cooling Compressor operation Mixed mode Wall-Air Displacement Model WDE40 WDE60 WDE80 WDEA0 WDEA2 WDEA4 WDEA6 Total cooling capacity kw 4.3 6.1 8.0 10.0 12.0 13.9 15.7 External sound pressure level 3) db(a) 50 51 52 53 54 58 60 Weight kg 170 200 200 240 240 250 250 Height (including condenser fan) mm 2,085 2,085 2,085 2,226 2,226 2,226 2,226 Width mm 879 879 879 992 992 992 992 Depht mm 565 565 565 730 730 730 730 Air flow in cooling mode m³/h 1,100 1,700 2,700 2,400 2,800 3,600 3,600 Air flow in free cooling mode m³/h 900 1,300 1,800 2,500 2,500 3,000 3,000 1) Outside temperature 35 C/Inside temperature 30 C/rel. humidity 30 % 2) 400V/3Ph/N/50Hz (Plus) 48V DC 3) Measured at 2m distance, free field 4

STULZ Cooling Solutions for Telecommunications 5

The C2020 control system The C2020 consists of an IO controller inside the unit and an optional operator terminal. The IO controller controls all the functions, the operator terminal (keypad) displays the most important operating states and alarms. The keypad, which also features an LCD, is able to configure and monitor up to 5 units. Sequencing Using the C2020, any desired number of standby units can be configured in an air-conditioning system. A system has a maximum number of 5 units. If an individual unit drops out or the heat load rises, inactive standby units are switched in for additional support. The operating times of all connected air conditioners are compared to ensure that each one is used to an equal extent. Controlling the various operating modes Compressor operation Free cooling function dependent on temperature and enthalpy Mixed mode management Backup ventilation upon failure of the main power supply Heating Humidification and dehumidification (humidification requires an external humidifier) Step-by-step operator guidance via keypad Operator Service (password-protected) Manufacturer (password-protected) Multilingual display The keypad can offer a choice of seven languages for the display of general menus, alarms and setpoints. Individual forwarding of alarms Via bus system/bms systems (optional) Via voltage free contacts (standard) 9 off-load contacts are available. Alarms can be assigned a high or low priority. High-pressure alarm management In order to avoid making unnecessary service calls, highpressure alarms are initially reset three times automatically. Then, after the fourth error message, the alarm must be deleted manually after 4 hours. Night mode Condenser and evaporator fan speed is limited in a timecontrolled manner, to ensure quiet operation e.g. at night or the weekend. Energy-saving mode The fan speed is automatically reduced (adjustable) at times when neither heating nor cooling is required. Integration in existing air-conditioning systems The comfort air conditioners commonly installed in base stations can be activated by the C2020 control. Air conditioning becomes more reliable and considerably more efficient. Flash EPROM for simple configuration and software updates Central configuration of units via laptop Hardware key for uploading and downloading software without a laptop and for copying the configuration to other units 6

Network solutions for communication without limits Compatible with all common BMS systems Communication using SNMP and HTTP IP protocols STULZ TeleCompTrol monitoring system as a bus and modem version C2020 C2020 C2020 C1002 C5000 C6000 C7000 ALARM Gateways for STULZ controller systems SMS/ E-mail Alarm/ voltage free contact Display/ visualisation Operation Remote monitoring and control Data protocol Modbus 1) Saia bus 1) P90 SNP Network bus SDC Ni bus LonTalk SNMP HTTP N2 bus 1) 4) Unigyr bus 1) 4) Sinec L2 bus GSM CompTrol 1) 3) SMS 1) Serial RS485 interface card required 2) Compatible gateways available as an option 3) Via voltage free contact 4) third-party supplier HTTP/ SNMP Remote maintenance Customer 7

STULZ Company Headquarters D STULZ GmbH Holsteiner Chaussee 283. 22457 Hamburg Tel.: +49 (40) 55 85-0. Fax: +49 (40) 55 85 352. products@stulz.de STULZ Subsidiaries AUS AT CN E STULZ AUSTRALIA PTY. LTD. 34 Bearing Road. Seven Hills NSW 21 47 Tel.: +61 (2) 96 74 47 00. Fax: +61 (2) 96 74 67 22. sales@stulz.com.au STULZ AUSTRIA GmbH Lamezanstraße 9. 1230 Wien Tel.: +43 (1) 615 99 81-0. Fax: +43 (1) 616 02 30. info@stulz.at STULZ AIR TECHNOLOGY AND SERVICES SHANGHAI CO., LTD. Room 5505, 1486 West Nanjing Road, JingAn. Shanghai 200040. P.R. China Tel.: +86 (21) 3360 7133. Fax: +86 (21) 3360 7138. info@stulz.cn STULZ ESPAÑA S.A. Avenida de los Castillos 1034. 28918 Leganés (Madrid) Tel.: +34 (91) 517 83 20. Fax: +34 (91) 517 83 21. info@stulz.es F STULZ FRANCE S. A. R. L. 107, Chemin de Ronde. 78290 Croissy-sur-Seine Tel.: +33 (1) 34 80 47 70. Fax: +33 (1) 34 80 47 79. info@stulz.fr GB I IN STULZ U. K. LTD. First Quarter. Blenheim Rd.. Epsom. Surrey KT 19 9 QN Tel.: +44 (1372) 74 96 66. Fax: +44 (1372) 73 94 44. sales@stulz.co.uk STULZ S.P.A. Via Torricelli, 3. 37067 Valeggio sul Mincio (VR) Tel.: +39 (045) 633 16 00. Fax: +39 (045) 633 16 35. info@stulz.it STULZ-CHSPL (INDIA) PVT. LTD. 006, Jagruti Industrial Estate. Mogul Lane, Mahim. Mumbai - 400 016 Tel.: +91 (22) 56 66 94 46. Fax: +91 (22) 56 66 94 48. info@stulz.in NL STULZ GROEP B. V. Postbus 75. 1180 AB Amstelveen Tel.: +31 (20) 54 51 111. Fax: +31 (20) 64 58 764. stulz@stulz.nl NZ PL SG USA ZA STULZ NEW ZEALAND LTD. Office 71, 300 Richmond Rd.. Grey Lynn. Auckland Tel.: +64 (9) 360 32 32. Fax: +64 (9) 360 21 80. sales@stulz.co.nz STULZ POLSKA SP. Z O.O. Budynek Mistral. Al. Jerozolimskie 162. 02 342 Warszawa Tel.: +48 (22) 883 30 80. Fax: +48 (22) 824 26 78. info@stulz.pl STULZ SINGAPORE PTE LTD. 33 Ubi Ave 3 #03-38 Vertex. Singapore 408868 Tel.: +65 6749 2738. Fax: +65 6749 2750. andrew.peh@stulz.sg STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive. Frederick, MD 21704 Tel.: +1 (301) 620 20 33. Fax: +1 (301) 662 54 87. info@stulz-ats.com STULZ SOUTH AFRICA PTY. LTD. Unit 18, Jan Smuts Business Park. Jet Park. Boksburg. Gauteng, South Africa Tel.: +27 (0) 11 397 2363. Fax: +27 (0) 11 397 3945. aftersales@stulz.co.za Technical data subject to changes without notice. 1000022 07-12 en. STULZ GmbH, Hamburg IT Cooling Solutions Close to you all over the world.... With specialist, competent partners in our subsidiaries and exclusive sales and service partners around the world. Our five production sites are in Europe, North America and Asia. www.stulz.com