Ultrasound Phantoms: B-Mode, Doppler and Others. Heather M. Pierce, B.S. Norfolk, VA

Similar documents
TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Routine Ultrasound Equipment Tests for Quality Assurance. Contents

Diagnostic Ultrasound Performance Testing & Accreditation

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

Ultrasound Fantomen.

Quantitative Imaging In Clinical Trials Using PET/CT: Update

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Physics testing of image detectors

Quality Control and Maintenance Programs

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI

Scanning Acoustic Microscopy Training

Accreditation Is Coming

APPLICATION OF ULTRASONIC IMAGING TECHNIQUE AS STRUCTURAL HEALTH MONITORING TOOL FOR ASSESSMENT OF DEFECTS IN GLASS FIBER COMPOSITE STRUCTURES

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

\ srl High Technology Gear Reducers and Cardan Shafts CERTIFIED QUALITY SYSTEM: UNI ISO EN 9001:2008 ICIM 2779/2; IQNET N. IT UNIVERSAL SHAFT

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Quality Assurance Concepts. Outline

INTRODUCTION. A. Purpose

Concepts for High-Resolution Low-Dose CT of the Breast

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

Quality Control of Full Field Digital Mammography Units

A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)

Injection moulding and modelling on a micro scale

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

Adaptation of General Purpose CFD Code for Fusion MHD Applications*

Saturation Biopsy vs. 3D Spatial Biopsy vs. Free Hand Ultrasound biopsy for Targeted Prostate Cancer Therapies

Mechanical Characterization of the Damage Process in a Structural Adhesive Joint by Acoustic Emission

Battery Thermal Management System Design Modeling

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

Ultrasonic Technique and Device for Residual Stress Measurement

Company profile. Quote from the analyst of. Company Milestone. Feel the Difference. Tel: Fax:

Cutting Edge Digital Radiography Technology in Daily NDT Use

Phased Array Ultrasonic Inspection Of 25%Cr Super Duplex Stainless Steel. On Subsea Manifold Piping Girth Welds In Lieu Of Radiography

MAINTENANCE AND INSPECTION OF BRIDGE STAY CABLE SYSTEMS

The leader in ultrasound training models. Over 150 different ultrasound training models available at

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

BIOMEDICAL ULTRASOUND

Heat Pipe Selection Revision 12/04/2001

Prepublication Requirements

Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Manual for Accreditation of Agencies for Quality Assurance of Diagnostic X-ray Equipment

METHOD OF STATEMENT FOR STATIC LOADING TEST

The promise of ultrasonic phased arrays and the role of modeling in specifying systems

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Ultrasonic Wave Propagation Review

Moving Beyond RECIST

Update on ACR Digital Mammography QC Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

Overview. Creation of 3D printed phantoms for clinical radiation therapy 7/7/2015. Eric Ehler, PhD Assistant Professor University of Minnesota

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

The Captivator II Snares are the first line of stiff and rounded snares available in multiple sizes with both a hot and cold snaring indication.

Acoustical Surfaces, Inc.

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

SAMSUNG ULTRASOUND RS80A

Expect. Endoscopic Ultrasound Aspiration Needles. Your Patient. Your Needle. Your Preference.

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Breast MRI Quality Control

Injection molding equipment

Principles and Working of Automated Reformer Tube Inspection System ARTiS

RICHARD T ELL ASSOCIATES,INC.

Copa Raked Bar Screen

p h a s e d - a r r a y t e c h n o l o g i e s w w w. m 2 m - n d t. c o m M2M today c o n t a c m 2 m - n d t. c o m

Captivator II. Single-Use Snares

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Antonio Rampoldi Struttura Complessa di Radiologia Interventistica Azienda Ospedale Niguarda Ca Granda, Milano. Terminology

PVC PIPE PERFORMANCE FACTORS

CONTENTS 1. INTRODUCTION METHODOLOGY RESULTS & FINDINGS...9 APPENDIX

Reliable Flaw Detection. Fast Inspection Times. High quality non-destructive testing services tailored for all your needs.

Specific volume and absorption properties

Green Thread Product Data

SOIL MECHANICS Assignment #4: Soil Permeability.

Industrial Metrology and Engineering Applications in the Wind Turbine Industry

Comparison to other anterior segment imaging devices

Additive manufacturing (aka 3D printing) of metallic materials Industrial applications and efficiency of technology

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

NDT Procedure for Liquid Penetrant Inspection TRINITY NDT. An ISO 9001:2008 Certified Company

Ultrasound Tissue Characterization an innovative method to visualize and monitor Patellar Tendinopathy

Progress in Two Dimensional Arrays for Real Time Volumetric Imaging

Simulation Study of Real Time 3-D Synthetic Aperture Sequential Beamforming for Ultrasound Imaging

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

NDT Procedure for Liquid Penetrant Inspection

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

July 23, Dear Mr. Kim:

Transcription:

Ultrasound Phantoms: B-Mode, Doppler and Others Heather M. Pierce, B.S. Norfolk, VA

Overview Design of ultrasound phantoms Types of phantoms available Use of phantoms in a QA/QC program Advantages and limitations of phantoms

What is an Ultrasound Phantom? A test object containing Tissue Mimicking Material (TMM) that simulates certain acoustic and physical properties of tissue May also contain various types of embedded objects Used to assess diagnostic ultrasound system performance over time

Agar Zerdine Urethane TPE Other Epoxies Liquids Natural materials Common TMM

Simulated Properties of TMM Speed of Sound Attenuation Coefficient Backscatter Coefficient or Relative Contrast Elasticity Thermal Properties Mechanical Properties

Important Properties for QA Speed of Sound Attenuation Coefficient Backscatter Coefficient 1540 m/s

Distance Measurements Volume Measurements Focusing Parameters Speed of Sound 120 mm

Important Properties for QA Speed of Sound Attenuation Coefficient 1540 m/s 0.5 db/cm-mhz 0.7 db/cm-mhz Backscatter Coefficient

Attenuation Coefficient Depth of Penetration Resolution Parameters 16 cm

Important Properties for QA Speed of Sound Attenuation Coefficient Backscatter Coefficient 1540 m/s 0.5 db/cm-mhz 0.7 db/cm-mhz 3 X 10-4 db/cm-sr

Backscatter Coefficient Depth of Penetration Resolution Parameters Lesion Detectability

Types of QC Phantom Targets Wires Properties 0.1mm - 0.3mm diameter nylon monfilament stainless steel Cylindrical & Spherical Anthropomorphic Objects Properties >1mm diameter varying contrast relative to background varying stiffness relative to background material Channels Properties >3mm diameter Walled or wall-less Can be attached to various pumping systems

Phantom Quality Target Position Verification CMM Machining Ultrasonic Techniques Acoustic Property Verification Testing on samples from individual batches or completed phantoms Visual Inspections

Types of Phantoms General Purpose QA Phantoms Typically used for general B-Mode imaging System Specific QA Phantoms Prostate Brachytherapy Breast Ultrasound 3D Systems Radiotherapy Systems Doppler Systems Elasticity Systems Training & Demonstration Phantoms Developing eye-hand coordination Learning general scan techniques System Demonstrations Task Trainers

Use of phantoms in Ultrasound QC/QA Equipment Selection Acceptance Testing/Commissioning Consistency Checks Is my system performing the same today as it did yesterday? Accreditation Programs ACR AIUM ICAVL

Phantom QA/QC Measurements B-Mode Parameters Image Uniformity Depth of Penetration Axial, Lateral and Elevational Resolution Near Field/Dead Zone Lesion Detectability high contrast (anechoic objects) low contrast (gray scale objects) 3-D Parameters Volume Reconstruction Accuracy Doppler Parameters Flow Rate System Sensitivity Directional Discrimination Location of Flow Maximum Penetration

Advantages of Ultrasound Phantoms Known characteristics Acoustic properties Size of embedded targets Location of embedded targets Stability over time Readily available

Limitations of Ultrasound Phantoms Difficult to determine specific mode of failure Qualitative vs Quantitative Stability over time

Ultrasound Phantom Manufacturers ATS Laboratories www.atslabs.com Blue Phantom www.bluephantom.com CIRS www.cirsinc.com Gammex www.gammex.com Kyoto Kagaku www.kyotokagaku.com