Kvernhuset Lower Secondary School



Similar documents
Green House, Hungary

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Klosterenga, Oslo, Norway, page - 1

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Norwegian Tax Authority - Oslo Norway

Sino-Italian Environment & Energy Building S I E E B

The first apartment house renovation with Passive House components in Norway

Energy Efficiency in Buildings

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

The Reunion experience

Integrated Solar Radiant Systems

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Siemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

ResearcH JournaL 2009 / VOL

Rainwater Harvesting

Data Collection Summary Report

Federation of European Heating, Ventilation and Air-conditioning Associations

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Adaptive strategies for office spaces in the UK climate

Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand

Case study on residential building renovation and its impact on the energy use and thermal comfort

Green and Sustainable Buildings

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Challenging the possibilities

Energy Efficient HVAC-system and Building Design

Mechanical and Natural Ventilation

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Green BIM/ Early BIM/

Each icon on this map represents the physical location of a station.

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Sustainable Features. High-performance HVAC. High-performance Envelope Green Roof Day-Lighting Bicycle Infrastructure

High Performance School Buildings Resource and Strategy Guide

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Energy Efficiency HOSPITALITY.

Directorate for the Built Environment Building Standards Division

SECTION MORTUARY REFRIGERATORS

Buildings Construction Procurement Strategy

Sea Water Heat Pump Project

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008

OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY

energy in education promoting energy efficiency in schools

SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight

The Integrated Design Process

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Case Studies: Infrared Heating in Industrial Applications

Systems Selection Enclosure Systems Material Selection Assessment and Mitigation

EarthCents (DSM) Program Summary

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

2009 Seattle Energy Code Impacts: See below for a recap of Changes in Envelope performance from 2006 to 2009

Energy efficient home design

Key energy-efficient features of your new home

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

Glass partitions SFB 3074

Energy-Plus Primary School, Hohen Neuendorf, Germany

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

ASTACEA4 Inspect complex/central air conditioning systems

3-D Modeller Rendered Visualisations

2014 British Columbia Building Code Changes

HVAC Systems: Overview

Passive house rehabilitation of post war residential building in Zug, Switzerland

Green Affordable Housing Development Case Eco-Viikki, Finland

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

School in Schwanenstadt, Austria

Passive House Projects in Norway an Overview

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

Archant London Environmental Awards

Mistrale. Fusion Terminal

Sustainability: Geothermal Energy for Sherman Hospital

Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf

Urban Environment: constraints and opportunities towards a sustainable quality

Every Student I Every Day I Every Possibility

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Direct Fresh Air Free Cooling of Data Centres

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5

Efficient use of energy simulation in the early design phase

Transcription:

Kvernhuset Lower Secondary School Name of building: Kvernhuset Lower Secondary School Location: Fredrikstad, Norway (59.12 N, 10.56 E) Owner: Fredrikstad Municipality Start of operation: January 2003 Figure 1. Computer model of the school building. PIR II Architects. Climate Fredrikstad is located at the east coast of Norway and has a costal climate with 3885 heating degree days (base 17 C). The monthly average temperatures and solar radiation is shown in Figure 2. Annual mean wind speed is 1.8 m/s. 20,0 250 15,0 200 temperature, C 10,0 5,0 0,0-5,0 jan feb mar apr may i jun jul aug sep oct nov des 150 100 50 0 Insolation, W/m² Temperature C Insolation W/m² Figure 2. Monthly average dry bulb temperatures and total horizontal solar radiation (24 hour average) for Halden (59.7 N, 11.17 E) which is the closest meteorological station to Fredrikstad. Context The school is situated in the suburbs of the city. Pine trees cover the site. There is a 3-5 m height drop in the terrain on the north part of the site, made by a long, steep, naked rock. The buildings are moderately shielded from wind. Illustration: Pir II Architects

Description of the building Gross floor area: 6865 m 2 Net conditioned area: 5700 m 2 Number of floors: 2 Number of pupils: 450-500 Operation time: The school is operated 5 days a week (06-22) all year around, except for 7 weeks during summer for the teaching space (2 nd floor), and 4 weeks for the office space. The main design idea of the school building was based on the active use of the site qualities: the rock, the forest and the light filtered by the trees. Wood and stones from the site were used as building materials. The first floor of the building cuts the rock. The burst rock mass is used as cladding on the facades of the ground floor. On top of the rock there are three rectangular, long and narrow wings that almost float over the ground. The wings façades testify to the design inspiration of the surrounding trees, and each wing has a slight strain of one of the colours: yellow, green or blue. The three wings have a light architectural expression that makes a strong contrast to the ground floor. The home bases (classrooms) for the pupils are situated in the wings. The materials have been chosen based on a range of criteria; recycling, embodied energy, maintenance, quality, cost and availability. Several surfaces have been constructed without any finish, or the finish consists of semiprocessed materials (e.g. particle boards are used as suspended ceiling elements). The main load bearing walls are made from prefabricated reinforced concrete. The ground floor façade is faced with gabions of unprocessed local granite encased in stainless steel mesh cages. The mass of concrete and stone increases the building s thermal inertia. The building s «spine» has been constructed from reused brick. Photos: Terje Heen, Fredrikstad Municipality and Inger Andresen, SINTEF. The facades of the pupils wings are faced with untreated pine wood taken from the trees which had to be cut on site in order to clear sufficient place for the building. Large areas of façade glazing and a number of skylights provide ample natural lighting.

The green roof system (sedum) requires only a shallow substrate. The plant species need minimum of maintenance and provide a green carpet with a changing of the season aspect. The classroom wings at the second floor have a relatively large window area (40% of the floor area). In the pre-design phase, double low-e windows with wood frame and a total U-value of 1.3 W/(m 2 K) was recommended (Andresen and Dokka 2001). However, the final window choice was double glazing with LE-coating and argon gas and aluminum frames, U = 1.5 W/(m 2 K). The translucent wall elements inserted in the fully glazed facades are made from recycled polyethylene (ISOFLEX) inserted between two layers of glass. In the schematic design phase, these elements were specified with a total U-value of 0.5 W/(m 2 K). The opaque walls have a U-value of 0.22 W/(m 2 K) and the roofs and floor have a U-value of 0.15 W/(m 2 K). Heating and cooling system: A 360 kw ground source heat pump has been installed for tap water heating, space heating and heating and cooling of the ventilation air. The heat is collected from 28 wells (depth: 175m). The annual COP of the heat pump was assumed to be 3.0. Ventilation system: Level 2 (classrooms) have a hybrid ventilation system, as shown in figure 3. The ventilation air is taken in via underground concrete culverts and supplied to the teaching space via brick interior walls and through valves near the ceiling. The air is exhausted through lamellas in the vertical parts of the skylights. The airflow rates are controlled according to outdoor temperature, see table 1. Figure 3. Section through pupils base area, level 2. Ventilation air is led from the culvert via shafts to a distribution chamber over the secondary rooms ( spine ). The exhaust air is evacuated via the skylights. Illustration: Pir II Architects. Figure 4. The air intake is through the glazed entrance of the building (left), down to the underground culvert (right). Photos: Inger Andresen, SINTEF.

Table 1. Design ventilation air flow rate as a function of ambient temperature. Ambient temperature, Air flow rate, m 3 /h C -20 13 200-15 19 800-10 21 120-5 22 440 0 25 080 5 26 400 10 33 000 15 52 800 20 66 000 Level 1 (administration) has a conventional mechanical ventilation system with heat recovery. Lighting system: Daylight is used to reduce the electric energy for artificial lighting and, at the same time, enhance indoor qualities and architectural values. The classrooms have both occupancy sensors and daylight sensors. Parametric studies were carried out to find the minimum glazing area allowing to achieve satisfactory daylighting requirements, including the best form and location of the additional window openings. The daylight simulations were made using the LesoDial computer program. The analyses showed that the simplest and the most effective alternative for the base area was a combination of large windows and skylights situated over the rear part of the class area. Large windows facing north and skylights allow achieving high daylight levels. North to the left Figure 4. Vertical cross section of pupils base area. Drawing from the architect s competition design (base case) to the left (Illustration: Barbara Matusiak, NTNU). As built, with additional skylights, to the right (Illustration Pir II Architects). Figure 5. Skylights used for lighting and for air exhaust. Photos: Inger Andresen, SINTEF.

Efficiency of space: Space efficiency and building flexibility were major concerns in the project. These issues were regarded as a major contribution to reducing the consumption of resources in a life cycle perspective. When designing base areas, one objective was to create flexible buildings adaptable to different functions. The school should have the possibility to experiment with different pedagogical settings. Rooms and furniture should be adaptable to various working methods. The wings with the pupil s base areas consist of three zones: area for classes, spine and common area. The basis for the class area is an unbroken area which can be divided into conventional classrooms, double classrooms, school landscapes or pupils offices. It is also possible to combine these alternatives. The design challenge was to create an infrastructure that favors flexibility. The wardrobes and the corridors with fixed installations were placed in the spine which also serve as a separating element between class areas and common areas. The common area contains a zone along the facade equipped with workbenches, washing troughs, aquarium and window gardens. The common area is meant to be a rough supplement to the class area. Walls can be placed in the construction axes and elsewhere the room can be connected to valves for inlet and outlet ventilation air. This means that a separated room has to be placed next to the spine to get inlet air, and at the same time has access to the dampers for outlet air in the base of the skylights. Large rooms may be divided into zones by means of light walls, book shelves, screens, plant cases, aquarium and trees. Changes may easily be accomplished and the pupils and teachers themselves can arrange and rearrange the lay-out of their area. The building as a teaching means One important objective of the project was to manifest measures that contribute to sustainability such that the measures have a demonstration and teaching effect. With demonstration in mind, or thinking of the school building and yard as teaching tools, three levels were defined: The first level was to demonstrate solutions chosen for the whole building complex. Special emphasis was given to: Utilization of daylight Utilization of natural driving forces for ventilation Utilization of geothermal heat (heat pump) Natural cleaning of waste water, both grey and black water The concepts and technical installation were made accessible for the pupils by various means; some ventilation ducts and water pipes were transparent, the equipment had peep-hatches so the pupils could check their insides, and the constructional elements were to a large degree stripped of finishings and claddings. The second level deals with measures that were too expensive or, for some other reason, were not suitable as a solution for the whole building complex. The pupils base areas were divided into three sections which each will have different installations for demonstration: Section YELLOW with focus on solar energy. Active and passive use of solar energy. Solar collectors and solar cells. Monitoring of energy use.

Section GREEN with focus on growth and recycling of materials. Vegetables and plants inside and outside. Ecological cycles. Section BLUE with focus on water. Collecting water from the roof. Water saving armatures in toilets and wash basins. The third level deals with devices which facilities for ecology studies (terrarium, aquarium, apparatus), and art decorations to highlight ecological aspects. Performance Describe real versus predicted performance and the reasons behind any discrepancies, with respect to: Computer simulations of the expected energy use were performed during the schematic design phase, using the computer Program SCIAQ Pro (Andresen and Dokka 2001). The simulations estimated the purchased energy use to 120 kwh/m 2 /year heated floor area, of which 100 kwh/m 2 /year was electricity and the rest was based on oil. This is well below experience from other similar buildings, which have an average energy use of 200 kwh/m 2 /year. The benchmark for energy efficient schools in this climate is 116 kwh/m 2 /year. Table 1. Estimated yearly net energy use in kwh/m 2 heated floor area, based on the schematic design (Andresen and Dokka 2001). Teaching wings Level 2 (3480 m 2 ) Administration Level 1 (2200 m 2 ) Total (5680 m 2 ) Space heating 73 41 60 Heating of ventilation air 86 52 72 Tap water heating 10 11 10 Fans and pumps 5* 35* 17 Lighting 9 20 13 Equipment 12 30 19 Space cooling 0 0 0 Cooling of ventilation air 2 6 4 Sum 196 195 196 *Energy use for pumps makes up 3 kwh/m 2 of this Table 2. Estimated yearly gross energy use (purchased) in kwh/m 2 heated floor area based on the schematic design (Andresen and Dokka 2001). Teaching wings Administration Level 2 (3480 m 2 ) Level 1 (2200 m 2 ) Total (5680 m 2 ) Elektricity 74 122 93 Oil 35 14 27 Sum 108 136 120 The measured energy use has not been obtained. However, there are some indications that the real energy use will be somewhat higher than estimated during early design phase: The realised building has a large window area with higher U-values than was recommended by the energy experts. The heat pump has been out of operation for some period dui to leakage of cooling fluid from compressor The exhaust air lamellas in the skylights cause cold draft due to non-optimal operation (too few wind sensors on the roof).

The exhaust air lamellas represent major thermal bridges. Other problems reported are: Acoustic rubber panels had to be installed in the underground culverts to reduce the noise from the fans. These panels caused some smell problems in the beginning. The central control system had a long start-up period, and had not been commissioned on year after construction. In general, the users of the building seem to be quite satisfied (Andresen, 2004). The interior spaces appear light, clean and attractive, and the air feels fresh. The users were particularly satisfied with the flexibility of the space the freedom to use the space in different ways (Andresen 2004). The project achieved large media attention and several architectural prices. It was also awarded the Eco-building of the year. Also, the school is very popular among pupils and teachers, and attracts applicants from teachers and pupils from all over the municipality. The investment costs were 201 mill NOK, including land and infrastructure and a sports hall. This was around 15% higher than the budget. However, the cost is similar to the cost of other new schools in the area. Design and construction processes The design and construction processes differed from a standard process in the following respects: A high degree of user involvement. The teachers, and to some degree the pupils, were involved from early design through construction. They contributed with a lot of ideas, especially with regards to using the building as a teaching means. A high degree of commitment towards the environmental issues by the client, the users (teachers, pupils, parents), the architects, the consultants, and the contractor. The design process was accompanied by an R&D project which involved architectural analyses, daylight analyses, energy analyses and environmental analyses. The project was organized as a general contract, see figure 6.

Client Fredrikstad R&D Project SINTEF, NTNU Design leader Pir II Architects Construction leader Architect Pir II Structural Reinertsen AS HVAC D.H. Jørgensen Electrical Bolkesjø AS Main contractor Subcontractors Subcontractor Subcontractor Figure 6. Organization of the project. There was no main responsible for the energy concept. The HVAC consultant had the responsibility for the HVAC systems, and the architect had the responsibility for the building shell and space layout. Additional expertise from the R&D project and from the local utility company was used in the early design phase, but these were not involved in the final design and choice of systems and constructions. The planning of the building started in 1995, with the appointment of a planning committee consisting of two politicians and user representatives. This committee was soon supplemented by public planners and NGOs. The planning committee arranged excursion to other schools with innovative environmental solutions, and they arranged working groups and a workshop together with the architects association. A functional program was prepared that asked for natural hybrid ventilation, utilization of daylight, renewable energy and water based heating, area efficiency, and environmental materials. Then, 4 architect s offices were selected for a competition. The competition was won by PIR II architects from Trondheim in co-operation with Duncan Lewis and Associates from the US. The concept of hybrid ventilation and the integration of a range of environmental issues were relatively new to the design and construction group. They had no formalized way of dealing with these issues. Name and affiliation of person filling out the template: Inger Andresen SINTEF Technology and Society Architecture and Building Technology N-7465 Trondheim Date: 05/09/2005 References Andresen, I. (2001), Miljøvurdering av Kvernhuset Ungdomsskole, SINTEF Rapport STF22 A01502, 12.01.01, Trondheim.

Andresen, I. og T.H. Dokka (2001), Energianalyse av Kvernhuset Ungdomsskole, SINTEF Rapport STF22 A01504, 26.02.01, Trondheim. Andresen, I. (2004), Evaluering av Kvernhuset ungdomsskole energi og miljø, SINTEF Report STF22 A04509, Trondheim, Norway. Buvik, K, I. Andresen, and B. Matusiak (2002), LA 21 Applied to Kvernhuset Secondary School in Fredrikstad, Norway, Paper at the International Conference Sustainable Building 2002, 22-25 September, 2002, Oslo, Norway. Matusiak, B. (2000), Daylighting in the Kvernhuset Lower Secondary School, Fredrikstad, Norway, Paper at the 17 th International Conference on Passive and Low Energy Architecture, July 3-5 2000, Cambridge, UK.