DOCUMENTATION PD16 CP3-SVE-M75DC-24



Similar documents
I STAR COMPUTER CO., LTD

APD / Outputs 19" DC/DC Converter, 50 Watt

Power Supplies 3. SDN-P DIN Rail Series

Operating Manual UWAPS-TINY Series

Chassis, Power Supply, and Element Management

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

User manual Rev. 1.2 (17/04/2015)

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Application Note TMA Series

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ST Series POWER SUPPLIES USER INSTRUCTIONS

650W Single Output Power Supply

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Thyristor-controlled power supplies and battery chargers

Quick Connect. quick - simple - efficient.

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

UMEC International Corporation

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

IMR 6000/10../20../30

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Redundancy Module QUINT-DIODE/40

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

MCR1900 Media Converter 19-Slot Chassis

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MINI MCR-SL-R-UI(-SP)

TEP 200WIR Series, Watt

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

GAE953 Electrical Alarm Unit 19" with Indicator

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

VS-0202 VS User Manual

Product and functional description

Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture

LwLVision-USB 2.0. Installation Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

DCS Series 1 kw, 1.2 kw, & 3 kw

EGSTON Standard E2xFxWx 12W

Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

R-78xx-0.5 INNOLINE. Features. 0.5 AMP SIP3 Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

Maximum Input Current Vin=18V, 100% Load A

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Pressure transmitter For general industrial applications Model A-10

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Analog signal converters CC-E I/I Current / current isolators

BITMAIN. APW PSU Series User Guide

Safety technique. Emergency stop module BO 5988 safemaster

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

R&S ZVA Vector Network Analyzer Specifications

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

Type: DILM32 10(24V50HZ) Article No.:

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Provides one channel for Ethernet over existing

E-STOP relays, safety gate monitors

3500/62 Process Variable Monitor

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

Magnet field- and Radiation Tolerant New Power Supply System PL500F8-12 MARATON

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes The Cool-Central Architecture

picopsu-90-xlp 12V, 90Watt ATX Power Supply Quick Installation Guide Version 1.0a P/N picopsu-90-xlp

Modular I/O System Analog and Digital Interface Modules

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Type: DILM9 10(24VDC) Article No.:

Provides one channel for Ethernet over existing

STLQ ma, ultra low quiescent current linear voltage regulator. Description. Features. Application

Watts SHP Series

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Installation and User Guide

Transcription:

» User Guide «CPCI Power Supply Manual PRODUCT DOCUMENTATION PD16 CP3-SVE-M75DC-24 Reference ID: 24139 PD16, Rev. 01 February 28, 2011 If it s embedded, it s Kontron.

PD16: CP3-SVE-M75DC-24 CPCI Power Supply Revision History Manual / Product Title: Reference ID: CPCI Power Supply Manual: Product Documentation: CP3-SVE-M75DC-24 24139 PD16 Rev. Brief Description of Changes Date of Issue 01 Initial issue Feb. 28, 2011 Imprint Kontron Modular Computers GmbH may be contacted via the following: MAILING ADDRESS TELEPHONE AND E-MAIL Kontron Modular Computers GmbH +49 (0) 800-SALESKONTRON Sudetenstraße 7 sales@kontron.com D - 87600 Kaufbeuren Germany For information about other Kontron products, please visit our Internet web site: www.kontron.com Disclaimer Copyright 2011 Kontron AG. All rights reserved. All data is for information purposes only and not guaranteed for legal purposes. Information has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respective owners and are recognized. Specifications are subject to change without notice. Page 2

CPCI Power Supply PD16: CP3-SVE-M75DC-24 1. Introduction The specific product description provided with this product documentation is part of the PEP s CPCI Power Supply manual. For further information, in particular regarding general details as well as safety and warranty statements, refer to the CPCI Power Supply Manual, ID 24139. This power supply is designed for use with the CP-Pocket or custormer specific applications only. 2. 75W M-Type Power Supply Unit The main features of the 3U M-type, lower-range input, 75 W output DC/DC power supply unit CP3-SVE-M75DC-24 are described in the following table: Table 1: Distinctive Features of Power Supply Unit CP3-SVE-M75DC-24 FEATURE SPECIFICATION Form Factor Front Panel Size Height of Power Supply Unit Width of Power Supply Unit Depth of Power Supply Unit Mechanics Plug-In Compatibility Power Supply Connector Input Voltage Output Voltages / Currents Output Power Total Minimum Output Load Cooling 3U 40.64 mm x 133.35 mm 3 U (128 mm) 8 HP (40 mm) 171.9 mm (without connector and handle) 19 rack Yes DIN M24/8 rear connector 18 V DC 36 V DC V 1 = + 5.1 V at 7.5 A symetrical, max. 15 A V 2 = + 3.3 V at 7.5 A symetrical, max. 15 A V 3 = V FAN = + 12 V at 0.16 A 75 W 0 W (for 3.3V and 5.0V) Forced air cooling, 1 m/s recommended minimum Redundant Supply Capability Status Indication Separate LEDs for V 1 and V 2 Special Feature(s) Input power either via DIN M24/8 rear connector or Phoenix 3-contact D-Sub front connector (depends of variant ordered) Page 3

PD16: CP3-SVE-M75DC-24 CPCI Power Supply 2.1 Mechanical Specifications Figure 1: View of Power Supply Unit CP3-SVE-M75DC-24 Page 4

CPCI Power Supply PD16: CP3-SVE-M75DC-24 2.2 Power Supply Connectors 2.2.1 DIN M24/8 Power Supply Connector Figure 2: Orientation of the DIN M24/8 Power Supply Connector Depending on the power supply version, DC power input may either be via the M24/8 connector or the front panel connector. The V1... V3 output voltages from the power supply unit to the backplane are connected via a 32-pole DIN 24/8 male power supply connector. For the pinouts of the DIN M24/8 power supply connector please refer to the following table. Table 2: DIN M24/8 Connector Pinouts PIN FUNCTION PIN FUNCTION 2 +Vin or NC (depends on version) B.17 +3.3VL 5 -Vin or NC (depends on version) B.18 +3.3VL 11 PE B.19 +12VL A.13 NC B.20 NC A.14 NC C.13 NC A.15 NC C.14 NC A.16 NC C.15 NC A.17 NC C.16 +3.3VL A.18 +3.3VL C.17 +3.3VL A.19 +12VL C.18 +3.3VL A.20 NC C.19 +12VL B.13 +3.3VL C.20 NC B.14 +3.3VL 22 +5VL B.15 +3.3VL 25 OVL B.16 +3.3VL Page 5

PD16: CP3-SVE-M75DC-24 CPCI Power Supply 2.2.2 Front Panel DC Input Power Connector This connector is available for applications requiring input power from the front of the chassis. If required, this connector must be specified when ordering. This is a Phoenix, 3-contact, D-Sub receptacle type connector (VS-PSC-1.5/3-M). The following figure and table provide pinout information. Figure 3: Front Panel DC Input Power Connector Table 4-3: Pinout of CONn PIN SIGNAL 3 2 1 1 +Vin 2 PE 3 -Vin 2.2.3 Line Input Connector This connector is the complementary connector for the application side for connecting to this power supply. If the front panel DC input power connector is specified, this connector is delivered with the power supply. This is a Phoenix, 3-contact, D-Sub plug type connector (PSC1,5/3-F). The following figure and table provide pinout information. Figure 4: Front Panel DC Input Power Connector Table 4-4: Pinout of CONn PIN SIGNAL 3 2 1 1 +Vin 2 PE 3 -Vin Page 6

CPCI Power Supply PD16: CP3-SVE-M75DC-24 2.3 Installation Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy installation, by which the power supply unit s male DIN M24/8 power connector is inserted into the backplane s mating female connector without the need of any intermediate adaptation. Note... The minimum input voltage for turn-on is 18 V. Use DC input power cable with a minimum cross-section of 0.75 mm². 2.4 Electrical Specifications Input Input voltage ranges 18V... 36 V DC Efficiency Typ. 83 % Input fuse F1 (may not be replaced by the customer) Output 6.3 AT, type Wickmann, no. 374/TR5 Output power V 1 (5.1 V), V 2 (3.3 V) Output power V 3 (12 V) Output fuse F2 (V 3 ) (may not be replaced by the customer) Total output loads 0 A typical 7.5 A max. 15 A min. 0.05 A - max. 0.16 A (15-17 V without load) 0.16 AT, type Wickmann, no. 374/TR5 min. 0 W max. 75 W Status indication Green LED s for V 1, V 2 Ripple V 1, V 2 < 100 mv pp, V 3 < 200 mv pp Noise voltage Typ. 75 mv @ 7.5 A Temperature regulation coefficient 0.03 % / K for V 1, V 2, and V 3 Switch on / switch off performance Rise-delay time Start-up time No overshooting of V out (soft-start) < 0.5 s 5 ms Page 7

PD16: CP3-SVE-M75DC-24 CPCI Power Supply Regulation Line regulation < 0.2 % for V 1, V 2 at a load of 7.5 A each Load regulation < 0.5 % for V 1, V 2 Protection and Control Overvoltage protection ( trip range % V 0 nom ) Output current limitation 115-140% 100% - 140% nominal output Environment Effective for all outputs, outputs short-circuit proof, hiccup-mode is used. Resettable fuse on V 1 and V 2 Non-resettable fuse on V 3 Overtemperature protection Switches off when inside temperature becomes too high, switches on again with hysteresis. Switch off at typ. 100 C base plate. Output short circuit duration: continuous Operating ambient temperature 0-50 C Derating temperature Humidity < 50 C / 0 % power derating 93 % RH at 40 C, non-condensing (according to IEC60068-2-78) EMC Interference suppression/immunity EN 61000-6-2 EN 55024 Interference emission EN 61000-6-4 EN 55022 Safety CB Schema EN 60950-1 Warning! Adequate thermal cooling of the power supply must be ensured. Therefore do not obstruct or hinder cooling air circulation or heat conduction within the power supply or surrounding equipment. Failure to comply with this warning may result in damage to your equipment. Page 8