Similar documents
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.


TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table


Fan, Cypress / GreenField Installation Instructions (sku )

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Thermo Top - Troubleshooting Tree

Manual for Fire Suppression & Methane Detection System

PUSH BUTTON START INSTALLATION MANUAL

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

REMOTE CONTROL MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS.

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Install Guide 3M-50. Caution. Caution

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

A/C-HEATER SYSTEM - AUTOMATIC

Cambridge Electric Infared Fireplace User Manual

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Porcia, 20 novembre 2012

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

K9 Heat Alarm Owners Manual HA-1520

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Digi-Motor Installation Guide

Install Guide CT101. Caution. Caution

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

TIPS ON ENERGY SAVING

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Troubleshooting Guide for Dispenser Model #900172

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Touch Tone Controller. Model TR16A. Owner s Manual

Gas Oven Repair Guide

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Appliance Diagnostic Modes Microwave. GE Consumer & Industrial Technical Training

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Installation Instructions. Thermo Call TC3

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Overheating limit control

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

INSTALLATION & SERVICE MANUAL. Display Panel

How do I monitor the ink levels on my EPSON Stylus printer using Windows 2000 or XP?

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

BODY ELECTRICAL MAZDA

Baxi Combi 80e & 105e

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Contact Details. Please note that some of the contact details on this PDF document may not be current.

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Home Theater PC Chassis

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Technical Information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

REAR-VIEW CAMERA INTEGRATION FOR SELECT CHEVROLET, CADILLAC & GMC VEHICLES 2013-UP

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

Fossil fuel heating equipment

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Pro Logic Version Diagnostics Manual

Instruction manual for Firstline FCS12000CH

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)


IH E Sigma Island 90

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

VR Pellet Control Board Compatibility valon ewport PS and ewport Bay PI (vanti PS & PI) valon storia PS and storia Bay PI Lopi Pioneer PS and Pioneer Bay PI (eritage PS & PI) Lopi Yankee PS and Yankee Bay PI Packing List Control Board (VR Design) Molex Jumper Overview he new VR control board is the next generation control board that is compatible with all pellet stoves and inserts, large and small manufactured from 1997 to today. Circuitry on the board allows it to be programmed for either the large or small pellet heaters (these heaters use different voltage settings). See Configuring the Control Board for details. It also includes a diagnostic feature that allows a service person to diagnose a fault without having to inspect the wiring or components. he indicator lights on the control board will display a fault code after a fault has been detected. his allows the service person to determine which component caused the fault. See Diagnostic Codes for details. O: the new wiring harness (250-00017) is required to utilize this feature. Configuring the Control Board Configuring for Large or Small eaters he control board is initially configured for the large heaters (storia and Yankee models). o change the configuration the control board must be in the off position plugged into a cold stove, (no lights or running components) with the jumper molex removed (see the illustration below). In this condition press and hold the manual auger button down and press both fan up and fan down arrow keys at the same time. ll heat output lights will flash. One flash denotes the large pellet heater configuration. wo flashes denote the small pellet heater configuration (ewport and Pioneer models). Repeat pressing the keys until the correct configuration is obtained. 250-00012 sing this Control Board with Older Wiring arnesses When the control board is installed on an older wire harness the 4 pin molex jumper plug on the back of the control board next to the stock wire harness must be installed. his jumper replaces the diagnostic wires (see Wiring Diagram ) that are present on the new wiring harness. he control board will work normally, but the diagnostic capabilities will not function. Page 1 of 2 Printed 1/24/06

echnical otes for Operation VR Pellet Control Board he new pellet control board is essentially the same as our old board. he biggest difference between them is that buttons were used in place of knobs on the heat and fan controls. Make sure to give the home owner the Pellet eater Operating Instructions if you are replacing an older board (the final 4 pages of this instruction sheet). It contains the new operating instructions for this control board. few changes were made to accommodate the new control board. he start up cycle indicator on the old board illuminates all heat output indicator lights to show the unit is in a start-up cycle and adjusting the heat setting knob would not change them. On the new board to enable adjusting the run settings during start-up we made the start-up indicator the blinking #1 heat output light. If the #1 heat output light is blinking the board is in a start-up mode and the blower and auger outputs can not be adjusted. he run settings the unit will go to after start-up are displayed on the heat output indictor. hese settings can be adjusted any time during start up by pushing the up or down heat buttons on the panel. When the fan setting is adjusted up or down the heat output indicators will turn off and the fan setting will display. nother feature we added to the control board is a manual auger feed. his button can be used to prime and empty the auger or speed the initial delivery of pellets to the burn pot. ll start-up timing remains the same and the stove will still self prime the auger tube this option allows the operator an additional option. It is not needed for normal operation. ll voltage outputs and feed rates remain the same as the old board. here is a difference in respect to the auger on/off times. he auger timing was changed to shorten the interval between pellet drops to the burn pot. or example, on low the auger used to turn for 3 seconds and remain off for 13 seconds, for this same condition this control board turns the auger for 2.5 seconds and remains off for 10.7 seconds. his produces the same amount of time the auger is turning and not turning but gives a steadier flame height and less incidental outages on low. Page 2 of 10 Printed 1/23/06

VR Pellet Control Board Diagnostic Codes (Qualified Service Personnel Only) ault and #2 (LOW) Light lash = low Switch ault ault and # 4 (MD) Light lash = System Snap Disk ault (pellets run out & stove goes cold) ault and # 6 (IG) Light lash = Safety or opper Snap Disk ault DISCOC POWR BOR SRVIC # 6 Light O P IG MD LOW RMO O GR L # 4 Light # 2 Light low Switch ault ault light and #2 heat indicator blinking. his fault code indicates pressure/flow switch opened or broke its electrical connection during operation. Likely causes: Pinched, cracked or broken pressure tubing. Plugged tubing nipple on blower housing. eavy ash build up in the exhaust fan housing, aulty wiring, bad or broken connection of flow switch gray wires. Weak or bad combustion blower aulty pressure switch. Page 3 of 10 Printed 1/23/06

VR Pellet Control Board Diagnostic Codes (Qualified Service Personnel Only) - Continued System Snap Disk ault ault light and #4 heat indicator blinking. his fault code is caused by a heat sensitive switch that tells the control board if the appliance is hot or cold. During operation if the unit runs out of pellets or looses its fire this switch will communicate to the control board that the stove is getting cold. he control board will shut off the auger functions and initiate a twenty minute combustion fan safety cool down. nother condition that will trigger this fault code is a failed start. When the appliance is started the control board initiates a 30 minute timer, if the appliance is cold at the end of this 30 minute start up timer the control board will indicate a #4 fault and initiate a 20 minute combustion fan cool down. Likely causes: nit ran out of pellets. ire went out during operation. nit was cold at the end of a start cycle (fire did not light). aulty snap disk. Safety or opper Snap Disk ault ault light and #6 heat indicator blinking. his fault code is caused by the safety or hopper snap disk registering an over-heated appliance during operation. he control board then shuts down the auger and the convection and combustion blower will run at maximum output for a 40 minute safety cool down cycle. he only way to stop this cool down is to unplug the appliance to reset the control board. Likely causes: aulty snap disk Corroded, loose or broken Snap Disk wiring. ailed, plugged or blocked convection blower. uced air flow into the motor compartment such as blocked air vents on panels or doors. Missing refractory. Improper fuel type. nauthorized parts used in the pellet feed system. Page 4 of 10 Printed 1/23/06

VR Pellet Control Board Wiring Diagram (new, 2005 version 250-00017) Pellet Wiring Diagram (wiring harness 250-00017) xhaust Blower low Switch Key to Quick Connects Male emale uger Motor Igniter opper Snap Disk Large Pellet Stoves Only Safety Snap Disk Orange Gray Gray Power Cord Common ot (fuse) Ground Convection Blower Orange Green 1 3 5 7 2 4 6 8 Screwed to Baseplate 3 7 5 1 6 4 2 8 1 3 Orange Gray System Snap Disk O: some models use quick-connects. Orange Gray 2 4 Page 5 of 10 Printed 1/23/06

VR Pellet Control Board Wiring Diagram (older version 100-00393B) O: Wire coloring may not be identical to this diagram. Pellet Wiring Diagram (wiring harness 100-00393B) xhaust Blower Key to Quick Connects Male emale uger Motor opper Snap Disk Purple Igniter Large Pellet Stoves Only Safety Snap Disk low Switch Blue Power Cord Common ot (fuse) Ground Convection Blower Green Screwed to Baseplate 1 3 5 7 2 4 6 8 3 7 5 1 6 4 2 8 System Snap Disk O: some models use quick-connects. O: Make sure the jumper plug is installed when using the VR control board with this wiring harness. Page 6 of 10 Printed 1/23/06

he wo Modes of Operation: Pellet eater Operating Instructions sing the VR Control Board Manual Manual mode requires the user to turn the heater on and off manually. uto (requires a thermostat) uto mode allows you to use a thermostat to control room temperature. he stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected. Switching Modes While in Operation Whenever the stove is switched from one mode to another while in operation, the stove will enter the "start-up" sequence for a minimum of 20 minutes. O P DISCOC POWR BOR SRVIC IG MD LOW RMO O GR L O M SR GR RVIS IDSRIS OS O IR O: if using a modulating remote, this light will come on to indicate the remote is controlling the heater. hese indicator lights are used to determine which mode you are in. se the mode switch to determine the mode. Page 7 of 10 Printed 1/23/06

Pellet eater Operating Instructions sing the VR Control Board Manual Mode Manual mode requires the user to turn the heater on and off manually. o Start O Press the "Manual Start" button. hat's it. he stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period the lowest O light will flash. If the stove does not start in 30 minutes, the stove turns off. SR GR Once up to temperature, the stove will then run at the heat output setting selected on the control panel (see o djust the eat below). M RVIS IDSRIS OS O IR o Shut Down Move the mode switch to "". he exhaust blower will still run until the heater cools down. O SR GR M RVIS IDSRIS OS O IR DISCOC POWR BOR SRVIC o djust the eat Press the "eat buttons to adjust the heat output. O: During start-up you may adjust the heat setting. his heat setting will take affect once the start-up sequence is complete. O P RMO IG O MD LOW GR L O SR GR hese lights indicate the heat output setting. O: the lights may be difficult to see from an angle. Press the up or down button to adjust the heat output. M RVIS IDSRIS OS O IR Page 8 of 10 Printed 1/23/06

Pellet eater Operating Instructions sing the VR Control Board uto Mode uto mode allows you to use a thermostat to control room temperature. he stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected. o djust Room emperature (or Start the Stove) Move the thermostat to the heat setting desired. If the room is cooler than the setting, the stove will go through the start-up sequence for approximately 10 minutes. During this period the lowest O light will flash. Once up to temperature, the stove will then run at the heat output setting selected on the control panel. If the room is too hot, move the thermostat to a lesser setting. o djust the eat Press the "eat buttons to adjust the heat output. I: If you find that the stove turns on and off repeatedly, you may wish to turn the heat output to a lesser setting. he lower setting will provide a more consistent heat output over time, eliminating the need for the thermostat to repeatedly turn the stove off. O: If the thermostat calls for heat while the stove is still cooling down, the stove will go through the start-up sequence (for a minimum of 20 minutes). O P DISCOC POWR BOR SRVIC RMO IG O MD LOW GR L O SR M GR RVIS IDSRIS OS O IR hese lights indicate the heat output setting. O: the lights may be difficult to see from an angle. Press the up or down button to adjust the heat output. o Shut Down Move the mode switch to "". he exhaust blower will still run until the heater cools down. O SR GR M RVIS IDSRIS OS O IR Page 9 of 10 Printed 1/23/06

djusting the an Speed Pellet eater Operating Instructions sing the VR Control Board O SR M GR RVIS IDSRIS OS O IR Press the up or down button to adjust the fan speed. O: When you press the an speed buttons the eat Output lights will indicate fan speed (not eat Output ). fter a few seconds the eat Output lights will go back to displaying the heat output setting. "L" Light his light comes on when an error occurs: DISCOC POWR BOR SRVIC # 6 Light he stove runs out of pellets During initial start-up (for a split second) or for improper electrical frequency start-up sequence that does not result in the heater coming up to temperature o reset the fault light, turn the mode switch to off and re-start the stove. O P IG MD LOW RMO O GR L # 4 Light # 2 Light ault Codes (for qualified service personnel only) ault and #2 (LOW) Light lash = low Switch ault ault and # 4 (MD) Light lash = System Snap Disk ault (pellets run out & stove goes cold) ault and # 6 (IG) Light lash = Safety or opper Snap Disk ault Page 10 of 10 Printed 1/23/06