Technical Information RIA14



Similar documents
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Software and Display instruments

TEIP11 I/P signal converter for standard signals. Measurement made easy

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

3DLevelScanner II TECHNICAL DATA SHEET

Technical Data. Dimensions

Technical Data. Dimensions

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Inductive sensor NI10-M18-Y1X-H1141

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Liquid Level Limit Switch liquiphant T FTL 20

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

IFC 070 Technical Datasheet

Plug and Socket Devices CES 63 A Series 8579

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data Sheet. 3DLevelScanner

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Preset Counter signo 721

Redundancy Module QUINT-DIODE/40

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Cross-beam scanning system to detect slim objects. 100 mm in

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Digital inductive conductivity transmitter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Flow switches Series AD/VH

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Analog signal converters CC-E I/I Current / current isolators

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Solenoid Valve Island Type 3965

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Differential Pressure Transmitter Model DPT-10

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electronic Pressure Switch EDS 3000

Scraper Passage Indicator. Electrical Indicator. Features

Type testing

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Plastic tube flowmeters Series PT/PS

Rosemount 751 Field Signal Indicator

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

SITRANS F flowmeters SITRANS F M

STB Series Enclosures

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

A good connection. International approvals.

How To Use A Flowmeter

Electronic Pressure Switch EDS 300

SEISMIC VELOCITY TRANSDUCER T1-40

Linear Luminaire with LED Series EXLUX 6402/2

S-series Mass Connection Solutions

Electronic Pressure Switches

Digital display DA 48

How To Use A Ds340 (Dsp)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Floodlight Range Installation Guide

Inductive slot sensor

How To Power A Schen

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Duct Humidity Transmitter

Terminal Boxes Series 8146

Pressure transmitter For general industrial applications Model A-10

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Centro-Matic Automatic Lubrication Systems System Controls

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Three-phase monitoring relay CM-PFE

Transcription:

TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical industry System and apparatus engineering Outdoor applications Laboratory facilities Process data acquisition and monitoring Optional: stainless steel housing Your benefits Loop-powered indicator in single compartment housing 5-digit LC display, character height 20.5 mm (0.8") Illuminated display, rotatable in 90 steps Trend bargraph in increments of 10% Measuring range display from -19999 to 99999 Digital limit switch Freely programmable units 3-key operation Approvals: ATEX, IECEx, FM, CSA, TIIS, UL listed, GL marine certificate 3 cable entries Configuration with FieldCare PC software Configuration without power supply using setup box

Function and system design Measuring principle Example of an application of the field indicator a0011145-en The indicator records an analog measuring signal and shows this on the display. The LC display shows the current measured value digitally and as a bargraph with limit value violation signalling. The indicator is looped into the 4 to 20 ma circuit and obtains the required energy from there. Measuring system Microcontroller controlled indicator in single chamber field housing with illuminated LC display. The measuring range, decimal point and offset of the indicator can be configured comfortably by means of three keys in the device with the housing open or by means of a PC with the FieldCare PC software. Input Measured variable Measuring range Current 4 to 20 ma (reverse polarity protection) Output Output signal Signal on alarm Transmission behavior Digital limit switch Passive, open collector: I max = 200 ma U max = 35 V U low/max = < 2 V at 200 ma Max. reaction time to limit value = 250 ms Temperature range: -20 to +80 C (-4 to +176 F) No measured value visible on the LC display, no background illumination. Open Collector inactive. The indicator allows the HART transmission protocol to pass unimpeded. 2 Endress+Hauser

Power supply Terminal assignment Terminal assignment of the field indicator a0010946-en Terminal Terminal assignment Input and output + Measuring signal (+) 4 to 20 ma Signal input - Measuring signal (-) 4 to 20 ma Signal input 1 Terminal for further instrumentation Support terminal 2 Digital limit switch (collector) Switch output 3 Digital limit switch (emitter) Switch output Supply voltage Voltage drop Terminals Cable entry Supply by means of the 4 to 20 ma current loop. Line voltage drop < 3.6 V at 3-22 ma Max. line voltage drop < 6 V at max. short-circuit current 200 ma Cables / wires up to max. 2.5 mm 2 (14 AWG) plus ferrule The following cable entries are available: Thread NPT1/2 Thread M20 Thread G1/2 2x gland NPT1/2 + 1x blind plug 2x gland M20 + 1x blind plug Endress+Hauser 3

Performance characteristics Reference operating conditions Maximum measured error Influence of ambient temperature T= 25 C (77 F) < 0.1% of scaled display range Effect on the accuracy when ambient temperature changes by 1 K (1.8 F): 0.01% Installation Mounting location Orientation Wall or pipe mounting (see 'Accessories') No restrictions, the orientation is determined by the readability of the display. Environment Ambient temperature range -40 to +80 C (-40 to +176 F) -20 to +80 C (-4 to +176 F) when the Open Collector output is used The display can react slowly for temperatures < -20 C (< -4 F). Readability of the display cannot be guaranteed at temperatures < -30 C (-22 F). Storage temperature -40 to +80 C (-40 to +176 F) Electrical safety As per IEC 61010-1, UL61010-1, CSA C22.2 No. 1010.1-92 Climate class Degree of protection Shock and vibration resistance Condensation As per IEC 60 654-1, Class C IP 67, NEMA 4X (not evaluated by UL) 3g / 2 to 150 Hz as per IEC 60 068-2-6 Permitted Installation category 1 to IEC 61010 Pollution degree 2 to IEC 61010 Electromagnetic compatibility (EMC) EN 61326 (IEC 61326): Electromagnetic compatibility (EMC requirements) NAMUR (NE21): Association for Standards for Control and Regulation in the Chemical Industry 4 Endress+Hauser

Mechanical construction Design, dimensions Die cast aluminum housing for general purpose or as option stainless steel housing Data in mm (data in inches in brackets) a0011152 Electronics compartment and connection compartment together in the single chamber housing Display can be rotated in 90 -stages Weight Approx. 1.6 kg (3.53 lb) (aluminium housing) Approx. 4.2 kg (9.26 lb) (stainless steel housing) Material Housing Die-cast aluminum AlSi10Mg with powder coating on polyester basis Nameplate Aluminum AlMgl, anodized in black Stainless steel 1.4435 (AISI 316L), as an option 1.4401 (AISI 316) Endress+Hauser 5

Operability Local operation LC display of the field indicator (illuminated, pluggable in 90 stages) Item 1: bargraph display in increments of 10% with indicators for measuring range undershoot (item 1a)/overshoot (item 1b) Item 2: measured value display, character height 20.5 mm (0.8") Item 3: 14-segment display for units and information messages Item 4: symbol "programming disabled" Item 5: unit "%" Item 6: warning symbol "failure" a0011157 Display range -19999 to +99999 Offset -19999 to +99999 Signalling Measuring range overshoot/undershoot Limit value violation Lower/upper limit value exceeded Operating elements 3-key operation (-/+/E) integrated in device, access with housing open Remote operation Configuration The device is configured with the FieldCare PC operating software. FieldCare Device Setup forms part of the scope of supply of Commubox FXA291 or TXU10-AC (see Accessories ) or can be downloaded free of charge from the Internet at www.endress.com. Interface Configuration interface at device; connection to PC via configuration cable (see "Accessories"). Configurable device parameters (selection) Measuring dimension, measuring ranges (linear/square), setup block using user code, failsafe mode, digital filter (damping), offset, limit value (min/max/alarm), alarm limit values freely adjustable. 6 Endress+Hauser

Configuration with PC operating software. a0011146-en Certificates and approvals CE mark Ex approvals Marine approval Other standards and guidelines The device complies with the legal requirements of the EC directives. Endress+Hauser confirms that the device has been successfully tested by affixing to it the CE mark. Information about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your E+H Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. Germanischer Lloyd marine certificate IEC 60529: Degree of protection by housing (IP-Code) IEC 61010-1: Safety requirements for electrical measurement, control and laboratory instrumentation. IEC 61326-series: Electrical equipment for measurement, control and laboratory use - EMC requirements. NAMUR: User association of automation technology in process industries (www.namur.de) NEMA: Standardization association for the electrical industry in North America. UL Recognized component to UL 3111-1 CSA GP CSA General Purpose Endress+Hauser 7

Ordering information Detailed ordering information is available from the following sources: In the Product Configurator on the Endress+Hauser website: www.endress.com É Select country É Instruments É Select device É Product page function: Configure this product From your Endress+Hauser Sales Center: www.endress.com/worldwide Product Configurator - the tool for individual product configuration Up-to-the-minute configuration data Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language Automatic verification of exclusion criteria Automatic creation of the order code and its breakdown in PDF or Excel output format Ability to order directly in the Endress+Hauser Online Shop 8 Endress+Hauser

Accessories Accessories Order No. FXA291 TXU10-AC Name Commubox FXA291 incl. FieldCare Device Setup and DTM library Commubox TXU10 incl. FieldCare Device Setup and DTM library Documentation Overview brochure: System components: FA00016K/09 Operating Instructions for 'RIA14 field indicator': BA00278R/09 Supplementary Ex documentation: ATEX II2(1)G EX ib[ia] IIC T6/T5/T4: XA090R/09/a3 ATEX II2G Ex d IIC T6/T5/T4: XA091R/09/a3 ATEX 2D Ex td A21 IP67 T110 C: XA092R/09/a3 Endress+Hauser 9

www.addresses.endress.com