Terms and Definitions In Canada



Similar documents
Tremco Fire Protection Systems Group Technical Bulletin

Excerpts from the Canadian National Building Code (NBC)

How To Build A Two Hour Firewall In Calgary

FIRESTOPPING & SMOKE SEALS

Firestopping & Fireblocking:

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

FIRE-RESISTANCE-RATED CONSTRUCTION

FIRE-RESISTANCE-RATED CONSTRUCTION

Complete Firestop Systems Guide

Gypsum Board Systems Manual

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FIRE AND SMOKE PROTECTION FEATURES

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Pyroguard Wired Glass

Fire Barriers & Fire Stopping

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

eading Performance Solutions

- 5 - Table1. Maximum Compartment Volumes

4 Installation Requirements

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Steel Door Institute. Fire Rated Doors and Frames

Flamesafe Firestopping Products. Firestopping Products.

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fiberglas, Exterior Wall Thermal Insulation

FIRESTOPPING. Cable. Firestopping is the technology used to

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fire-Rated Glass and Glazing START

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

How To Test For Premer Retardant

English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

Executive Summary Inclusion of Current Firewall Requirements in NBCC

Overview of Hotel Fire Safety Requirements

Fire and Concrete Structures

Fire Testing of Recycled Materials for Building Applications

Safe Operating Procedure

Basic Fire Door Requirements

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Services Enclosures and Protected Shafts - Maintaining Compartmentation

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Introduction to cable fire stopping

GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Australian/New Zealand Standard

EcoTouch Insulation with PureFiber Technology

WHITE PAPER Fire & safety performance standards

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

Fire Stopping and Penetration Seals for the Construction Industry SECOND EDITION

NFPA 101 SAF-FIR PUBLIC COMMENTS

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

IMO Resolution A.754(18) Fire Resistance Tests Fire Safety Onboard Ships BY

Fire Resistance of Brick Masonry

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Fire Performance Standard

2014 British Columbia Building Code Changes

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Electrical Code (NEC) Snake Tray Cable Management Solutions

Product Information Sheet

Fire safety in timber buildings

FIRE AND SMOKE PROTECTION FEATURES

REFERENCE STANDARD RS 13 MECHANICAL VENTILATION, AIR CONDITIONING, AND REFRIGERATION SYSTEMS * LIST OF REFERENCED NATIONAL STANDARDS

A Code Review for Emergency Generators and Indoor Use of Portable Generators

The Source of Firestop Expertise SM

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Errata NFPA 70. Proposed 2014 Edition

CHAPTER 6 DUCT SYSTEMS

Wood use in Type I and II (noncombustible) construction

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

Mechanical insulation to increase building efficiency. Saving money, energy and the planet.

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Fire Barrier Duct Wrap 15A

State of Connecticut Department of Public Health RADON PROGRAM

Fire rated and smoke outlet ductwork

How to Prevent Liquid Damage Property Losses

Decree of the Ministry of the Environment on fire safety of ventilation systems

Safety & Performance in the Wire and Cable Industry

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Wood-frame Construction, Fire Resistance and Sound Transmission

Rules for Classification and Construction Additional Rules and Guidelines

Catalog Number Pillow Type Pillow Size

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

800 Communications Circuits

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Building Code Clarifications - 7. Fire Resistance

HOT WORK PERMIT PROCEDURES

PYROSWISS VETROFLAM CONTRAFLAM

Product Guide Specification

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Transcription:

Terms and Definitions In Canada Most of the following terms and definitions are taken directly from the National Building Code and referenced Test Methods. Learning these terms will provide an important knowledge base to understanding the requirements for Firestopping. Fire Compartment Fire Separation Firewall Fire Resistance Rating Combustible Construction Noncombustible Construction Firestop System Firestop Systems Report Listed System Designs Service Penetration Firestop Material Single Component Firestop System Multiple Component Firestop System Tightly Fitted Third Party Testing Agency Authority Having Jurisdiction References And Acceptable Standards Canada CAN/ULC S101 (Test Specimen) CAN/ULC S115-95 Fire Test Sample CAN/ULC S115-95 "F" Rating Fire CAN/ULC S115-95 "FT" Rating Fire & Temperature CAN/ULC S115-95 "FH" Rating Fire & Hose CAN/ULC S115-95 "FTH" Rating Fire Temperature & Hose CAN/ULC S115-95 "L" Rating (Optional) Leakage Rate CAN/ULC S115 Test Reporting Fire Compartment Fire Compartment; means an enclosed space in a building that is separated from all other parts of the building by enclosing construction providing a Fire Separation having a required fire-resistance rating. (ref: NBC Part 1 Section 1.1.3.2). Fire Compartments are also referred to as Fire Zones. Fire Separation Fire Separation; means a construction assembly that acts as a barrier against the spread of fire. A fire separation may or may not have a fire-resistance rating. (ref: NBC Part 1 Section 1.1.3.2 & Appendix A)

Firewall Firewall; means a type of fire separation of noncombustible construction which subdivides a building or separates adjoining buildings to resist the spread of fire and which has a fire-resistance rating as prescribed in the NBC and has structural ability to remain intact under fire conditions for the required fire-rated time. (ref: NBC Part 1 Section 1.1.3.2). Fire Resistance Rating Fire Resistance Rating; means the time in hours or fraction thereof that a material or assembly of materials will withstand the passage of flame and the transmission of heat when exposed to fire under specified conditions of test and performance criteria, or as determined by extension of interpretation derived therefrom as prescribed in the National Building Code. (ref: NBC Part 1 Section 1.1.3.2). Combustible Construction Combustible Construction; means that type of construction that does not meet the requirement for noncombustible construction. Combustible means that a material fails to meet the acceptance criteria of CAN/ULC S114, (Standard Method of test for determination of non-combustibility in Building Materials) (ref: NBC Part 1 Section 1.1.3.2). Noncombustible Construction Noncombustible Construction; means that type of construction in which a degree of fire safety is attained by the use of noncombustible materials for structural members and other building assemblies. Noncombustible means that a material meets the acceptance criteria of CAN/ULC S114, (Standard Method of test for determination of non-combustibility in Building Materials) (ref: NBC Part 1.1.3.2). Firestop System Firestop System; means a specific construction consisting of any device intended to close off an opening or penetration during a fire and/or materials that fill an opening in a wall or floor assembly where penetration is by cables, cable trays, conduits, ducts, pipes and any poke through termination device, such as electrical outlet boxes along with their means of support through the wall or the floor opening. (ref: CAN/ULC S115 Section 1.7). Firestop System Test Report Firestop System Test Report; means results reported in accordance with the performance in the tests prescribed in the CAN/ULC S115 methods. (ref: CAN/ULC S115 Section 9.1). Listed Systems Designs The Accredited Testing Agency s informational listing developed from the Firestop System Test Report. This report depicts the correct use and installation procedures for firestop materials to create a Firestop System. These published listings include: The assembly materials, the penetrating items and the firestop components, identified and described.

Drawings depicting geometry, exact size (length, width, thickness) and location of firestop systems within the test assembly. Service Penetration Service Penetration; piping, tubing, ducts, chimneys, electrical wires and cables, totally enclosed noncombustible raceways, electrical outlet boxes and other similar building services that penetrate a membrane forming part of an assembly required to have a fire-resistance rating or a fire separation. (ref. NBC Part 3.1.9.1.(1)). Firestop Material Firestop Material; Firestop Material; means any device intended to close off an opening or penetration during a fire or materials that fill an opening in a wall or floor assembly where penetration is by cables, cable trays, conduits, ducts and pipes and any poke-through termination devices, such as electrical outlet boxes along with their means of support through the wall or floor opening. (CAN/ULC-S115 Section 1.7). Single Component Firestop System Single Component Firestop System; means a Firestop Material that has a Listed Systems Design and is used individually without the use of high temperature insulation or other materials to create a firestop system. Multiple Component Firestop System Multiple Component Firestop System; means the exact group of Firestop Materials that are identified within a Listed Systems Design to create a on site Firestop System. Tightly Fitted Tightly Fitted; (ref: NBC Part 3.1.9.1.1 & 9.10.9.6.1) means penetrating items that are cast in place in buildings of Noncombustible Construction or have "0" annular space in buildings of Combustible Construction. The words "tightly fitted" should ensure that the integrity of the fire separation is such that it prevents the passage of smoke and hot gases to the unexposed side of the fire separation. (ref. NRC National Research Council, letter dated July 94). Third Party Testing Agency Third Party Testing Agency; means any accredited Standards Council of Canada notified testing agency approved to perform Fire Endurance Testing as outlined in this section of Work which includes any of the following agencies; (ref: NBC Appendix A.2) Underwriters Laboratories (Canada). CUL mark. Underwriters Laboratories (United States), CUL mark. Only tests performed to the CAN/ULC S115 Standard after the SCC Canadian accreditation date of October 14 1994 will be accepted. Extrapolations from United States of America ASTM E-814 tests are NOT ACCEPTABLE. ASTM E-814 test methods do not required a hose stream on assemblies up to 1 hour, the hose stream test is a mandatory requirement of the CAN/ULC S115 test method.

Intertek Testing Services. (formerly Warnock Hersey), WH mark. Authority Having Jurisdiction Authority Having Jurisdiction (AHJ); means the governmental body responsible for the enforcement of any part of the NBC or the official or agency designated by that body to exercise such a function and/or the Architect. (ref: NBC Part 1.1.3.2). REFERENCES AND ACCEPTABLE STANDARDS CANADA Can/ULC S101 Standard Method of Fire Endurance Tests of Building Construction Materials Can/ULC S115 Standard Method of Fire Tests of Firestop Systems Can/ULC S102 Standard Method of Testing for Surface Burning Characteristics of Building Materials and Assemblies. CAN/ULC S101 Article 2 Test Specimen 2.1 The test specimen shall be truly representative of the construction for which classification or rating is desired, as to materials, workmanship, and details such as dimension of parts, and shall be built under conditions representative of those obtaining as practically applied in building construction and operation. The physical properties of the materials and ingredients used in the test specimen shall be determined and recorded. 2.3 The size and dimension of the test specimen specified herein are intended to apply for rating constructions of dimensions within the usual general range employed in buildings. If the condition of use limit the construction to smaller dimensions a proportionate reduction may be made in the dimensions of the specimens for a test qualifying them for such restricted use. CAN/ULC S115-95 Fire Test Sample 4.1.1. Construction: The construction of the test firestop systems shall include conduits, pipes, cables (jacket types, sizes, conductor type, per cent fills), required supports, poke through devices or other through-penetrating items so as to produce a truly representative firestop system for which evaluation is desired. Firestop systems shall be installed and tested in each construction type for which ratings are desired. 4.1.2 Through-penetrating items are to be installed such that they extend 300mm beyond the firestop system on the exposed side and 900mm on the unexposed side. The extended portion of the through penetrating item on the unexposed side shall be supported in the same manner as methods employed in field installation. 4.1.3. The exposed individual ends of pipes or conduits or both shall be covered and sealed by suitable means to prevent excessive transfer of gases through the items between the furnace and the laboratory environment. The individual ends of pipes or conduits or both which are located on the unexposed side of the assembly shall not be covered or sealed.

CAN/ULC S115-95 "F" Rating Fire 8.2.1 Firestop systems shall be considered as meeting the requirements for an F rating if it remains in the opening during the fire test for the rating period without permitting passage of flame through openings, or the occurrence of flaming on any element of the unexposed side of the firestop system. CAN/ULC S115-95 "FT" Rating Fire & Temperature 8.3.1 Firestop systems shall be considered as meeting the requirements for an FT rating if it remains in the opening during the fire test within the limitations as described in Clause 7.2.1 and 7.3.2. 8.3.2 The transmission of heat through the firestop system during the rating period shall not have been such as to raise the temperature of any thermo-couple on the unexposed surface of the firestop system more than 181 C (358 F) above its initial temperature. CAN/ULC S115-95 "FH" Rating Fire & Hose 8.4.1 A firestop systems shall be considered as meeting the requirements for the "FH" rating if it remains in the opening and does not permit the passage of flame during the fire test and remains in the opening during the hose stream test within the limitations as described in Clauses 8.2.1 and 8.4.2 8.4.2 During the hose stream test, the firestop system shall not develop any opening that would permit a projection of water from the stream beyond the unexposed side. CAN/ULC S115-95 "FTH" Rating Fire Temperature & Hose 8.5.1 A firestop systems shall be considered as meeting the requirements for the "FTH" rating if it remains in the opening and does not permit the passage of flame or increase in temperature during the fire test and remains in the opening during the hose stream test within the limitations as described in Clauses 8.2.1, 8.3.2 and 8.4.2. CAN/ULC S115-95 "L" Rating (optional)leakage Rate 8.6.1 The "L" rating shall be reported as the largest test sample leakage rate, Q, determined from the air leakage test. Separate ratings may be identified for each individual air pressure and temperature exposure, or both. CAN/ULC S115 Test Reporting 9.1 Results shall be reported in accordance with the performance in the tests prescribed in these methods. Reports shall include the following: The assembly, the materials and penetrating items of the test firestop systems shall be identified and described. Drawings depicting geometry, exact size (length-width-thickness) and location of firestop systems within the test assembly shall be recorded; The moisture content of the test assembly and firestop material, if applicable, shall be reported.