SIMATIC HMI SIMATIC S7-200. Machine Interface. for internal use only. www.siemens.com/s7-200/ Automation and Drives SIMATIC S7-200



Similar documents
SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Analog Inputs and Outputs

SIMATIC. S7-200 Programmable Controller System Manual A B C D F G. Preface, Contents. Product Overview 1.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

SIMATIC. S7-200 Programmable Controller System Manual A B C D F G. Preface, Contents. Product Overview 1.

Optimize your simple machines... Modicon M218 Selection Guide

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Data sheet SLIO CPU 015 (015-CEFPR00)

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

1 Application Description Objective Goals... 3

Temperature & Humidity SMS Alert Controller

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

S-series SQ Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SIMATIC S7-200 PRICE LIST

CPUs - CPU PN/DP

M2M/IoT Solutions.

SIMATIC S Workshop. Unrestricted / Siemens AG All Rights Reserved.

S7-1500/S7-1500F Technical Data

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

S7-1500/S7-1500F Technical Data

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Z-TWS4. Multifunction Straton / LINUX Controller.

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

SIMATIC S It s the interplay that makes the difference. SIMATIC Controller. Answers for industry.

Disturbance Recoder SPCR 8C27. Product Guide

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

Programmable Controller G Series. New. Models

Easy to connect - Easy to configure Easy to install

Bellplast S.R.L. Informe del Dpto. Técnico

PRODUCT LIST Facility DDC Access WebXL DDC

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Permissible ambient temperature Operation Storage, transport

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SIMATIC S Basic Controller in the TIA Portal

S and STEP 7 Basic V10.5


MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Section TELEPHONE AUTOMATIC DIALER SYSTEM

CP Page 1342 Mar 2008 Siemens ITS

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

The CP provides access to different communication services of the PROFIBUS bus system:

Telephone- and leased line modem for industrial applications TD-36

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

6ES BE01-0AB0 6ES BE01-0AB0

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

40.3. Control Relays and Timers

PCS0100en Persy Control Services B.V. Netherlands

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry.

PROFIBUS AND MODBUS: A COMPARISON

The CP FO provides access to different communication services of the PROFIBUS bus system:

SCADA and Monitoring for Solar Energy Plant

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Smart relays Zelio Logic Step into an intuitive world!

Development of a Gateway to PROFIBUS for Remote Diagnostics

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

M-series Virtual I/O Module 2

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Ponto Series. A new concept for automation

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

MLC TM Maximum Productivity and Versatility for Control without Compromise!

OZW30. Central Unit SYNERGYR

Rack mounted telephone- and leased line modem for industrial applications

SMS GSM Alarm Messenger

Configuring PROFINET

Benefits of a Colter OEM design / Embeded PLC

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Electro Hydraulic System (EHS)

Programmable Logic Controller PLC

The Total Package. Where innovative ideas are born. Free software suite upgrades for life Free technical support Hands-on PLC and OI training

PECS The Control System for Extrusion Blow Molding

Industrial Training Schedule Spring 2012

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOFTLINK 300. CPU Specifications. Reference Manual

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Partner for automation Water technology

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Using installed Fieldbus Wiring to carry Ethernet Communications

GPS NTP Time Server for Intranet Networks DIN RAIL Version

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

PROFIBUS fault finding and health checking

S7-300/S7-300F S7-300F

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Modicon M340 The all-in-one PAC

Automation & Control Planning Guide

CPU PN/DP. Function

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Transcription:

www.siemens.com/s7-200/ A&D AS, 07/2004, Chart 1

within the SIMATIC family Micro Automation Small,compact systems Easiest programming tools with Wizards micro automation sets as solution from one supplier Totally Integrated Automation Shared data management, configuring and communications Highest performance Programming with high-level languages LOGO! S7-200 S7-300 S7-400 A&D AS, 07/2004, Chart 2

S7-200 Second Generation CPU 221 (10 I/O Points) CPU 222 (14 I/O Points) ) CPU 224 (24 I/O Points) CPU 224XP (24 I/O Points) CPU 226 (40 I/O Points) Improved 2004 New 2004 Improved 2004 A&D AS, 07/2004, Chart 3

Features: CPUs (1/2) Features: Integrated Inputs/Outputs Max. Expansion Modules Max. # of Dig. I/O Channels Analogue Points In/Out/Max CPU 221 6DI/4DO - 10 - CPU 222 8DI/6DO 2 78 8/4/10 RETURN Program/Data Memory 4KB/2KB 4KB/2KB Boolean Execution Time 0.37 µs 0.37 µs Bit Relays/Counters/Timers 256/256/256 256/256/256 High Speed Counters Real Time Clock Pulse Outputs Communication Interface 4 x 30 khz optional 2 x 20 khz 1x RS-485 4 x 30 khz optional 2 x 20 khz 1x RS-485 Analogue Potentiometers 1 1 A&D AS, 07/2004, Chart 4

Features: CPUs (2/2) Features: Integrated Inputs/Outputs Integrated Analogue In/Out CPU 224 14 DI/10 DO - CPU 224XP 14 DI/10 DO 2AI/1A0 CPU 226 24 DI/16 DO - RETURN Max. Expansion Modules Max. # of Dig. I/O Channels Analogue Points In/Out/Max Program/ 7 168 28/14/35 8/12 KB 7 168 30/15/38 12/16 KB 7 248 28/14/35 16/24 KB Data Memory 8 KB 10 KB 10 KB Boolean Execution Time Bit Relays/Counters/Timers High Speed Counters Real Time Clock Pulse Outputs 0.22 µs 256/256/256 6 x 30 khz Integrated 2 x 20 khz 0.22 µs 256/256/256 4 x 30 khz 2 x 200 khz Integrated 2 x 100 khz 0.22 µs 256/256/256 6 x 30 khz Integrated 2 x 20 khz Communication Interface 1 x RS-485 2 x RS-485 2 x RS-485 Analogue Potentiometers 2 2 2 New & Improved 2004 A&D AS, 07/2004, Chart 5

S7-200 Standards Standards Compliance: European Underwriters Factory C-Tick Community Laboratory Mutual for Australia & Canada & Approved New Zealand United States Maritime : Lloyds Register of Shipping (LRS) American Bureau of Shipping (ABS) Det Norske Veritas (DNV) German Lloyd (GL) Nippon Kaiji Kyokai (NK) Bureau Veritas (BV) Polski Rejestr Statkow A&D AS, 07/2004, Chart 6

Built-in Features Cartridge Slot CPU Status LEDs I/O Point Status LEDs Internal: - Power Supply - Super Capacitor -Clock (224(XP),226) Communication Port(s) Removable Terminal Blocks (224(XP),226) Snap-On Clip for DIN Rail Mounting 24V Sensor Power Output Mounting Holes for Panel Installation Improved 2004 A&D AS, 07/2004, Chart 7

224XP Built-in Features Removable Analogue Terminals Cartridge Slot CPU Status LEDs I/O Point Status LEDs Internal: - Power Supply - Super Capacitor -Clock (for 224,224XP,226) Mounting Holes for Panel Installation Removable Terminal Blocks (224,226) Communication Ports 24V Sensor Power Output Snap-On Clip for DIN Rail Mounting New 2004 A&D AS, 07/2004, Chart 8

in detail... Flexible Memory Modules Battery module Clock and battery module Real-time clock and calendar (for 221, 222 CPU) Typically 200 days backup. Backup of the internal data (data block) Typically 200 days backup For general program transfer and backup Data Logging Files, Recipes Files, and General File Storage New 2004 A&D AS, 07/2004, Chart 9

Diagnostic LED on on New & Improved CPUs All the new and improved CPUs have a multi purpose Diagnostic LED. The Diagnostic LED is combined with the System Fault LED. The combined LED is either RED or YELLOW depending on the fault. The Diagnostic LED is controlled by both the operating system and the user s program by means of the Diagnostic instruction The Diagnostic LED can be turned on when a value is FORCED or an I/O Error occurs or the USER s program commands it on. Diagnostic LED New Micro/Win Instruction New 2004 A&D AS, 07/2004, Chart 10

Expansion I/O Modules: General Up to 2 Modules (EM) for 222 CPUs.up to 7 EMs for 224/226 CPUs Removable Terminals on digital I/O Modules Module Connection via I/O Expansion Ribbon Cable CPU-Basic Device + Expansion Module Connection slot Connector A&D AS, 07/2004, Chart 11

Expansion I/O Modules many options Digital 8 In DC 8 In AC, 120/230 VAC 16 In DC 4 Out DC 5A 4 Out Relay - 10 A 8 Out DC - 0.75 A 8 Out AC -120/230 VAC, 0.5 A 8 Out Relay - 2 A 4 In / 4 Out DC-DC 4 In / 4 Out DC-Relay 8 In / 8 Out DC-DC 8 In / 8 Out DC-Relay 16 In / 16 Out DC-DC 16 In / 16 Out DC-Relay Analogue 4 In 4 In / 1 Out Temperature Measurements 4 In T/C 2 Out 2 In RTD Position IT Communication Technology Communikation Modem PROFIBUS DP Slave Ethernet AS-i Master A&D AS, 07/2004, Chart 12

module (EM 253) Provides High-Speed control, from 12 to 200,000 PPS. Configurable backlash compensation Continuous operation Supports: Jerk (S curve) or Linear acceleration and deceleration Supports absolute, relative and manual methods of position control Simple programming and commissioning with the Wizard A&D AS, 07/2004, Chart 13

S7-200 Networking possibilities: S7-22x CP 243-2 EM 277 EM 241 CP CP 243-1 243-1 IT + Email + HTML + FTP Ethernet Network Phone Network PROFIBUS Network AS Interface Field Bus PPI/MPI Network ASCII Protocol (FreePort) A&D AS, 07/2004, Chart 14

Modem module (EM 241) Provides: International telephone line interface Modem programmed with STEP7 Micro/WIN Password protection Security callback Plug&Play Supports: The Modbus RTU protocol Numeric and text paging SMS messaging (depending on provider) CPU-to-CPU or CPU-to-Modbus data transfers Simple programming with the Micro/WIN Wizard A&D AS, 07/2004, Chart 15

PROFIBUS DP Slave Module (EM 277) Connects the S7-200 as a slave to a PROFIBUS DP network Provides: 9.6 KBit/s to 12 Mbit/s Transfer Rate (with Auto Detection) PPI-Advanced, MPI und PROFIBUS DP protocol Four LED Status Indicators Station Address Selectable by Rotary Switches (0..99) Supports: Max. 99 Devices on the Bus (Addresses from 0... 99) Up to 1200 m Segment Length (at max. 93.75 KBit/s) A&D AS, 07/2004, Chart 16

AS Interface Master Module (CP 243-2) Provides: 2 Pushbuttons on Module to Toggle Display & Operation Mode LEDs to Display Slave Status, Errors and Bus Status Supports: 62 AS-Interface Slaves can be Connected Cycle Length 5 ms (31 slaves) or 10 ms (62 slaves) Cable Length 100 m Class M1e Master Two Operation Modes: Standard Operation (accessing I/O Data Blocks of the Slaves) Extended Operation (also Write Parameter Data or Poll Diagnostic Data) Simple Programming with the Wizard A&D AS, 07/2004, Chart 17

Ethernet Module (CP 243-1) Simple Connections as an EM Allows processing data Simple Network administration Easy Exchanging of Modules (plug & play) Provides Ethernet access via an RJ45 jack A connection to PC-Access software Remote programming, configuration and diagnostics Simultaneous communication with up to 8 S7 controllers Facilitates a flexible and distributed automation structure Simple Programming with the Wizard A&D AS, 07/2004, Chart 18

Ethernet Networking with CP 243-1 Communication via Industrial Ethernet Uses Standard Read & Write Services Up to 212 bytes of user data per command. Supports up to 8 communication channels Client / Server operating Simple Programming with the Wizard Ethernet Cable A&D AS, 07/2004, Chart 19

IT Communications Module (CP 243-1 IT) Provides: The same network features like the CP 243-1 Send up to 32 E-Mail s Transfers up to 32 files via FTP Integrated Web Server Built-in user diagnostic HTML pages Built-in system diagnostic HTML pages Supports: Visualization with JAVA and HTML Data exchange of files by means of FTP Simple Programming with the Wizard A&D AS, 07/2004, Chart 20

Human- Units MatchedtotheS7-200 Optimal Price / Performance ratio Easy Engineering with TD 200-Wizard, TP Designer and WINCC flexible micro Text Display TD 200 Text Display TD 200C With User- Customized Faceplate Touch Panels: - TP 070 - TP 170micro Text panels Graphics panels PC-based human machine interface A&D AS, 07/2004, Chart 21

STEP7-Micro/WIN 32. Setting THE Standard in Micro PLC Programming Simple Installation and Configuration EASY to Learn, EASY to Use Comprehensive programming tool Find & Correct quickly fixes errors Tools to handle Running PLC Changes Documentation for easy maintenance Wizards simplify programming tasks Software tools for easy commissioning A&D AS, 07/2004, Chart 22

Your Choice of Editors Use the right tool for the job Ladder & FBD editors for graphic languages (IEC 1131-3) STL for text programming Switch between editors as necessary Easy error identification Save project in any case STL FBD LADDER A&D AS, 07/2004, Chart 23

The Wizards: Wizards make the programming easier TD 200 Text Display Internet Module (a) High Speed Counters Ethernet Module (b) NETR/NETW Networking (c) PID Control Instruction (a) Modem Module (b) External Modem Data Log Wizard (a) PTO/PWM (b) Position Module Recipe Wizard (a) Map AS-i Slaves (b) Change AS-I Addresses Position Control Panel PID Auto Tune Control Panel A&D AS, 07/2004, Chart 24

Application examples...over 1,000,000 applications world wide Woodworking Conveyor systems Pump controls Filling plants Vacuum suction systems/elevators A&D AS, 07/2004, Chart 25

Elevators with optimal stopping accuracy Cost savings Easy to adjust to individual customer requests Remote monitoring for costeffective service Quality enhancement Digital monitoring of shaft using incremental encoders (exact position acquisition of the elevator) Saves on magnetic switches A&D AS, 07/2004, Chart 26

for internal use only Suction extraction systems for woodworking Cost savings Reduction in wiring and startup costs using the AS-Interface Connection of shutoff valves in the suction system Efficient service using modem technology Quality enhancement Calculation of the optimal suction power Reduction in power consumption A&D AS, 07/2004, Chart 27

Woodworking machinery Cost savings Flexible solution for easy expansion Easy implementation of customer requirements Quality enhancement Precise positioning for better control A&D AS, 07/2004, Chart 28

Low-cost ball presses Cost savings Simple and fast changeover from relay technology to PLC electronics Low space requirements for smaller control cabinet Quality enhancement Flexible solution for easy expansion Increased operational information using nonvolatile data backup A&D AS, 07/2004, Chart 29

Maintenance and Support Worldwide Support: Global Service and Repair Network Quick Spare Parts Delivery 24/7 Support Hotline Programming Support Product and Application Information Training Seminars Internet Software Support: Extensive Product Information including Manuals Software and Documentation Updates Tips & Tricks Application Examples Demo Software Online Training (Step 2000) A&D AS, 07/2004, Chart 30

SIS Co., Ltd. Đại lý phân phối thiết bị SIEMENS Tự động hóa 53 Lê Thị Hồng Gấm, Quận 1, TP Hồ Chí Minh Tel: 84-8-914 3632 / 914 3633 Fax: 84-8-821 7184 Email: sis-co@hcm.vnn.vn; support@sis-vn.com Website: sis-vn.com A&D AS, 07/2004, Chart 31