FA 2510. Digital Display. Manual. for parallel signal sources



Similar documents
MOTORI ELETTRICI TRIFASE SERIE MS MOTORI ELETTRICI MONOFASE SERIE MY

1.- L a m e j o r o p c ió n e s c l o na r e l d i s co ( s e e x p li c a r á d es p u é s ).

ASCENT TM Integrated Shipment Management

SM Interface modules

LED BUILT-IN MODULES. LUGA Shop 2013 LED Modules COB for Retail Environments. LUGA SHOP 2013 HiCRI lm TO 5000 lm. LUGA SHOP 2013 HiCRI

Polish public opinion on the Eu ro pe an Union and the Con sti tu tio nal Tre a ty

Put the human back in Human Resources.

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

JCUT-3030/6090/1212/1218/1325/1530

Warsaw School of Economics (SGH)

Compact POS System. User Manual

H ig h L e v e l O v e r v iew. S te p h a n M a rt in. S e n io r S y s te m A rc h i te ct

ES Series 150 W DC POWER SUP PLIES

Edi son Lamp hol ders Made of Ther mo plas tics and Por ce lain

THE CULTURAL ACTIVITIES CLUSTER IN PORTUGAL Trends and perspectives

SM Series 3300 W DC POWER SUP PLIES

Campus Sustainability Assessment and Related Literature


Nikon Capture 4 CMS The Color Management Tab (Windows) Change Display Profi le Advanced Add

Cooperation Agreement 2006

He Will Hold Me Fast (When I Fear My Faith Will Fail)

SM Se ries 800 W DC POWER SUP PLY

TECHNICAL DATA. NOTES: For use with Trim Chart on page 27 b. (open fold-out)

CYBERSPACE RECON. Explo ring the virtual jungle

SM Series 1500 Watts DC POWER SUP PLIES

With Rejoicing Hearts/ Con Amor Jovial. A Fm7 B sus 4 B Cm Cm7/B

Institutional development in three regional blocs

M1000 Process Alarm Monitor

Short information Parameters are programmed via front-side membrane keypad

Digital Pressure Measuring Instrument MDR480

Come stà. Domenico Maria Ferrabosco (Bologna ) Cantus. - ta, _e vo - lon - tie - ri M'al -le-gro _e can -to _en. Io mi son gio vi.

Preset Counter signo 721

Modular I/O System Analog and Digital Interface Modules


Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

INSTALLATION INSTRUCTION

Auto mo tive Cor po ra tion TC 237 TRANSFER CASE PARTS MAN UAL

TX OPEN RS232/485 module

A 03 T IE POMPE A INGRANAGGI SERIE APL GEAR PUMPS APL SERIES

SCO TT G LEA SO N D EM O Z G EB R E-

TROU BLE SHOOTING VIKING ALARM VALVES

GAE953 Electrical Alarm Unit 19" with Indicator

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Digital input modules

Drug policy in Poland time for a change

Multifunction devices

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2


I n la n d N a v ig a t io n a co n t r ib u t io n t o eco n o m y su st a i n a b i l i t y


RS - SPM. Serial parallel translator module

Control Devices Catalogue. Control Devices. Preferred and Standard Products

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

THE PASCHAL PROCLAMATION. Longer form of the Paschal Proclamation

i n g S e c u r it y 3 1B# ; u r w e b a p p li c a tio n s f r o m ha c ke r s w ith t his å ] í d : L : g u id e Scanned by CamScanner

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)


Sænk kun dit hoved du blomst Senke dein Köpfchen, du Blume, Lay down, sweet flower, your head.

LSNJ...justice for all

1. Oblast rozvoj spolků a SU UK 1.1. Zvyšování kvalifikace Školení Zapojení do projektů Poradenství 1.2. Financování

R e t r o f i t o f t C i r u n i s g e C o n t r o l



DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Lens Equation Purpose

ni - do_in che la mia fe - ni - ce

Redundancy Module QUINT-DIODE/40

G- 100-R 12/24. NOTIFIER ITALIA a Pitt way Company. Gas detection Control Panel. Installation and operating manual. Do cu men t: M- 030.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Stand Alone En ergy Re cov ery Ven ti la tors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL


Online Department Stores. What are we searching for?

GAP ANALYSIS & SUB-CERTIFICATION. Internal Controls Overview

AIS750 Series Alarm Annunciator

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

w ith In fla m m a to r y B o w e l D ise a se. G a s tro in te s tin a l C lin ic, , K a s h iw a z a, A g e o C ity, S a ita m a

Excel Invoice Format. SupplierWebsite - Excel Invoice Upload. Data Element Definition UCLA Supplier website (Rev. July 9, 2013)


Như ng kiê n thư c câ n biê t vê giâ y phe p cư tru điê n tư (eat)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

PCS0100en Persy Control Services B.V. Netherlands

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Bewährte Six Sigma Tools in der Praxis

Duct Humidity Transmitter

THE EF FECT OF L-CAR NI TI NE ON DI GE STI BI LI TY AND CAR NI TI NE ME TA BO LISM IN PI GE ONS (CO LUM BA LI VIA DO MES TI CA) FED CORN OR PEAS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

PT-100. Use and pro gram ming man ual. Soft ware Ver d IST-PT Rev. -

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Transcription:

FA 2510 Digital Display for parallel signal sources Manual

War ran ty For de li ver ed pro ducts our "All ge mei ne Lie fe rungs- und Zah lungs be din gun gen" are ef fec ti ve. In no event we or our supp liers shall be li ab le for any ot her da ma ges what soe ver (in clu ding, wit hout li mi ta tion, da ma - ges for loss of bu si ness pro fits, bu si ness in ter rup ti on or ot her pe cu nia ry loss) ari sing out of or ina bi li ty to use this pro duct. All our pro ducts are war ran ted against de fec ti ve ma te ri al and work mans hip for a pe ri od of two (2) ye ars from date of de li very. If it is ne ces sa ry to re turn the pro duct, the sen der is re spon si ble for ship ping char ges, freight, in su ran ce and pro per pa cka ging to prevent brea ka ge in tran sit. The war ran ty does not ap ply to de - fects re sul ting from ac ti on of the buy er, such as mis hand ling, im pro per in ter fa cing, ope ra ti on out si de of de - Tra de marks All tra de marks that are na med or por tray ed in the text are re gis te red tra de marks of its owner.

INHALTSVERZEICHNIS 1. Des crip ti on........................... 4 2. Sa fe ty in struc tions....................... 5 2.1. Sym bols in this ma nu al.................. 5 3. Mounting............................ 6 3.1. Pla ce of ope ra ti on..................... 6 3.2. Moun ting the dis play.................... 6 3.2.1. Hou sing for switch bo ard................ 6 3.2.2. Hou sing for mo saic sys tems.............. 7 4. Elec tri cal con nec tions..................... 8 4.1. Ge ne ral In struc tions.................... 8 4.2. Hints against noi sy en vi ro ments.............. 8 4.3. Con nec tions and pin as sig ne ment............ 9 4.4. Con nec tions of the po wer supp ly............. 10 4.5. Con nec tions of the in puts................. 10 5. Startup procedure....................... 10 6. Programming.......................... 11 6.1. Avai la ble pro gram ming le vels............... 12 6.2. Pro gram ming le vel P-00.................. 13 7. Functions............................ 14 7.1. Ex ter nal de ci mal point con trol............... 14 7.2. Stro be in put........................ 15 7.3. Dis play over flow...................... 15 7.4. Dis play test........................ 15 8. Tech ni cal Data......................... 16 8.1. Electrical Data....................... 16 8.2. Me cha ni cal Data...................... 16 8.3. En vi ron ment........................ 16 9. Or der in for ma ti on........................ 17 10. No tes.............................. 18 ERMA-Electronic GmbH 3

1. Description 1. Description The FA 2510 is a di gi tal dis play for par al lel sig nal sour ces. It can be used e.g. to get - her with PLCs or ab so lut en co ders to dis play an gles or dis tan ces. Programmable functions par al lel in put, 16 bit max. (or 15 bit + sign) BCD-, BI NARY- or Gray- Code pro grammable ska ling fac tor 0.0001... 9.9999 pro grammable off set -9999... 99999 ex ter nal/in ternal de ci mal point con trolex ter ner Stro be e in gang wähl bar Input for dis play test Date : 05.10.2005 FA2510 Tech ni cal Sub jects to change 4 ERMA-Electronic GmbH

2. Safety instructions 2. Safety instructions This in stru ment is pro du ced in ac cor dan ce with Class II of IEC 348 and VDE 0411. When de li ver ed the in stru ment has been tes ted to meet all functions des cri bed. Be fo - re in stal ling the in stru ment plea se read the moun ting and ser vi cing in struc tions. We have no lia bi li ty or re spon si bi li ty to cus to mer or any ot her per son or en ti ty with re - spect to any lia bi li ty, loss or da ma ge cau sed or al le ged to be cau sed di rect ly or in di rect ly by equip ment or soft wa re sold or fur nis hed by us. Read the in stal la ti on in - struc ti on ca re ful ly. No lia bi li ty will be as su med for any da ma ge cau sed by im pro per in stal la ti on. In spect the in stru ment mo du le car ton for ob vi ous da ma ge. Be shu re the re are no ship ping and han ding da ma ges on the mo du le be fo re pro ces sing. Do not ap ply po - wer to the in stru ment if it has been da ma ged. ERMA s war ran ty does not ap ply to de fects re sul ting from ac ti on of the buy er, such as mis hand ling, im pro per in ter fa cing, ope ra ti on out si de of de sign li mits, im pro per re pair or un aut ho ri zed mo di fi ca tions. 2.1. Symbols in this manual Caution Attention Instruction Hint Caution: Will be used at dan ge rous for life and he alth! At ten ti on: Will cau se da ma ge. Instruction: If not no ti ced, trouble may oc cur. Hint: Use ful hints for bet ter ope ra ti on. ERMA-Electronic GmbH 5

3. Mounting 3. Mounting 3.1. Place of operation At ten ti on must be paid to the pro tec ti on against hu mi di ty, dust and high tem pe ra tu res at the pla ce of ope ra ti on. 3.2. Mounting the display 3.2.1. Housing for switchboard For moun ting in switch bo ards, in sert the case into the pa nel cu tout (ac cor ding to DIN 43700: 45,0 +0,6 x 22,0 +0,3 mm) from the front, using a fresh gas ket for sea ling as re qui red. Click into and pla ce at each side the two fas te ning clips (M2,5 x 50 mm). Tighten the screws al ter na te ly, using enough pres su re to get good re ten ti on and sea ling at the pa nel. 22,2 24,0 +0,3 48,0 panel cutout DIN 43700 21,0 42,0 45,0 +0,6 11,0 57,2 5 6 ERMA-Electronic GmbH

3. Mounting 3.2.2. Housing for mosaic systems In sert the case into one of the fol lo wing mo saic-sys tems: a) Mo saic sys tem 8RU (M50x25) from Sie mens b) Mo saic sys tem from Sub klev 24,0 21,0 48,0 mosaic-system: Siemens 8RU (M50x25) Subklev 42,0 11,0 57,2 5 ERMA-Electronic GmbH 7

4. Electrical connections 4. Electrical connections 4.1. General Instructions It is for bid den to plug or un plug con nec tors with vol ta ge ap plied At tach in put and out put wi res to the con nec tors only wit hout vol ta ges ap plied Cords must be pro vi ded with slee ves At ten ti on must be paid that the po wer supp ly vol ta ge ap plied will agree with vol ta ge no ti ced at the name pla te. The in stru ment has no po wer-on switch, so it will be in ope ra ti on as soon as the po wer is con nec ted. 4.2. Hints against noisy enviroments All in puts and out puts are pro tec ted against noi sy en vi ron ment and high vol ta ge spi - kes. Ne ver the less the lo ca ti on should be se lec ted to en su re that no ca pa ci ti ve or in - duc ti ve in ter fer en ce can have an ef fect on the in stru ment or the con nec ti on li nes. It is ad vi sa ble: To use shiel ded ca bles. The wi ring of shields and ground (0V) should be star-sha ped. The dis tan ce to in ter fer en ce sour ces should be as long as pos si ble. If ne ces sa ry, pro tec ti ve screen or me tal en clo su res must be pro vi ded. Coils of re lays must be supp lied with fil ters. Par al lel wi ring of in put sig nals and AC po wer li nes should be avoi - ded. 8 ERMA-Electronic GmbH

4. Electrical connections 4.3. Connections and pin assignement All in puts and out puts are con nec tors, de sig ned as plug-in screw ter mi nals. 2 1 26 25 Anschlußbelegung Pin Signal Pin Signal BCD BINÄR GRAY 5 1 2 0 =1 E1 1 Strobe 7 2 2 1 =2 E2 2 decimal point 2 0 + button* 9 4 2 2 =4 E3 3 decimal point 2 1 - button* 11 8 2 3 =8 E4 4 display test P - button* 13 10 2 4 =16 E5 15 20 2 5 =32 E6 21/22 Signal ground 17 40 2 6 =64 E7 19 80 2 7 =128 E8 6 100 2 8 =256 E9 23/24 Power supply (-) 8 200 2 9 =512 E10 25/26 Power supply (+) 10 400 2 10 =1024 E11 12 800 2 11 =2048 E12 14 1000 2 12 =4096 E13 16 2000 2 13 =8192 E14 18 4000 2 14 =16384 E15 20 8000 2 15 =32768 E16 or sign (-) or sign (-) or sign (-) * de tails to the +, - and P but tons see page 19 Sig nal ground (Pin 21/22) and the mi nus con nec ti on of the po wer supp ly (Pin 23/24) are not con nec ted in ter nal. ERMA-Electronic GmbH 9

5. Startup procedure 4.4. Connections of the power supply 2 1 24 26 23 25 - + 23/24: GND 25/26: 18..36 V DC 4.5. Connections of the inputs + Ub 0V Un con nec ted sig nal in puts are de tec ted as low sig nal. 5. Startup procedure At ten ti on must be paid to thecorrect po wer supp ly vol ta ge. The used po wer supp ly have to agree with the vol ta ge no ti ced at the type pla te. Ap ply the cor rect vol ta ge to pin 23/24 (-) und pin 25/26 (+) Switch the po wer supp ly on. When de li ver ed, the in stru ment is pro - gram med to the de fault con fi gu ra ti on. Plea se check the pro gram ming sec ti on of this ma nu al for furt her de tails. At ten ti on: The con fi gu ra ti on of the de vi ce has to be com pa ti ble to the sour roun ding it is con nec ted. Ot her wi se mal functions or da ma ges may oc cu re. 10 ERMA-Electronic GmbH

6. Programming 6. Programming The pro gram ming of the dis play is made via the pins 2, 3 and 4. The se pins are ac ti - vat ed by a high le vel (5V, 12V or 24V). The ea siest way to do this is to at tach 3 push-but tons to pin2, 3 and 4. The se but tons are na med with "+", "-" and "P". Ins te ad of push-but tons the pins can also be ac ti vat ed by any ot her di gi tal sig nal sour ce, e.g. by a PLC. The push-but tons are not part of the de vi ce! High level-signal to Pin 4 P - button Pin 2 + - button Pin 3 - - button Function Selecting - Programming levels - Parameters Incrementing the - Programming level - Parameter number - Parameter value Decrementing the - Programming level - Parameter number - Parameter value En ter into the pro gram ming mode push P"-but ton plus +"-but ton the dis play shows P-00" Finish the Programming mode push +"-button or -"-button as long un til the dis play shows PEnd push P"-button re turn to the nor mal dis play mode Selecting the next pro gram ming le ve l se lect with the +"-button or the -"-but ton the wis hed pro gram ming level con firm the se lec ted pro gram ming le vel with the P"-button ERMA-Electronic GmbH 11

the pa ra me ter num bers of the se lec ted pro gram ming le vel are dis play ed e.g.: 0-00" => Pa ra me ter 0 of pro gram ming level 0 Re turn from the pro gram ming le vels push +"-button or -"-but ton as long un til the dis play shows xend e.g.: 0End =>Re turn from pro gram ming le vel 0 con firm with the P"-button the dis play shows the next hig her pro gram ming le vel e.g. P-00" => for pro gram ming le vel 0 Se lec ting the Pa ra me ters 6. Programming push the +"-but ton or the -"-button to se lect the wis hed Pa ra me ter con firm the pa ra me ter with the P"-but ton the dis play shows the last pro gram med va lue of the se lec ted pa ra me ter Chan ge and con firm chan ges of the se lec ted pa ra me ter chan ge the pa ra me ter va lue with the +"-button or -"-but ton con firm the para me ter va lue with the P"-button the dis play shows the pro gram ming le vel and the pa ra me ter num ber e.g.: 0-05" => para me ter 5 of pro gram ming level 0 6.1. Available programming levels The FA 2510 has one pro gram ming le vel. P-00: Programming level for device configuration This pro gram ming le vel can be used to ad just the de vi ce to the cus to mers ap pli ca - tions. 12 ERMA-Electronic GmbH

6. Programming 6.2. Programming level P-00 Param. Fuction Range Default 0-00 0-01 0-02 Input configuration 0 -> BCD-Code 1 -> Binary-Code 2 -> Gray-Code Display configuration 0 -> Display = 5-digits 1 -> Display = 4-digits + sign Activating the offset value 0 -> Offset value deactivatet 1 -> Offset value activated 0.. 2 0 0.. 1 0 0.. 1 0 0-03 Offset value -9999.. 99999 0 0-04 0-05 0-06 Selecting the decimal point control 0 -> External decimal point control 1 -> Internal decimal point control Internal decimal point control 0 -> XXXXX 1 -> XXXX.X 2 -> XXX.XX 3 -> XX.XXX 4 -> X.XXXX Display brightness 0 -> Display brightness 50% 1 -> Display brightness 100% 0.. 1 0 0.. 4 0 0.. 1 1 0-07 Scaling factor 0.0001.. 9.9999 1.0000 0-08 Configuration of the strobe input 0 -> externa strobe activated 1 -> externer Strobe deactivated 0-09 Reserve:no function 0End Leaving programming level P-00 0.. 1 1 ERMA-Electronic GmbH 13

7. Functions 7. Functions The par al lel sig nal data are read via an I/O chip from the mi cro pro ces sor of the de vi - ce. Af ter pro ces sing the data the result is dis play ed. The par al lel data can be pro ces - sed BCD, bi na ry or GRAY coded. Parallel inputs Dri ven by 24 V, 12 V or 5 V sig nal level, high active Inputs BCD-, Binary- or GRAY-coded 7.1. External decimal point control The pins 2 and 3 can be used for the ex ter nal de ci mal point con trol. To use this functi - on par a me ter P 0-04 has to be set to 0. Pin 3 (2 1 ) Pin 2 (2 0 ) Anzeige low low XXXXX low high XXXX.X high low XXX.XX high high XX.XXX External decimal point control Set para me ter 0-04 to 0 in puts are high side swit ched, high ac ti ve and bi na ry coded. If the functi on 'ex ter nal stro be sig nal' (P 0-08 set to 1) is ac ti vat ed the ex ter nal de ci mal point sig nals are pro ce sed with the ri sing edge of the stro be sig nal. The first de ci mal point from the left ( X.XXXX) can only be ac ti vat ed by the in ter nal de ci mal point control. 14 ERMA-Electronic GmbH

7. Functions 7.2. Strobe input The data on the in puts are dis play ed with the ri sing edge of the stro be sig nal (pin 1). The dis play will be re fres hed with every new stro be sig nal. Strobe input Set para me ter 0-08 to 0 the stro be in put is high side swit ched; take-over with the ri sing edge of the sig nal. 7.3. Display overflow If the in put va lue plus the off set va lue (pa ra me ter 0-03) is grea ter than "99999" you will get an over flow. In this case the dis play shows "nnnnn". 7.4. Display test With the dis play test (set pin 4 to high le vel) you can check the com ple te dis play. The dis play shows 8.8.8.8.8. Ac ti va ting the dis play test high side swit ched, high ac tive (set pin 4 to high le vel) if the ex ter nal stro be is ac ti vat ed (pa ra me ter 0-08 is set to 0) the dis play test will be ac ti vat ed with the ri sing edge of the stro be sig nal. ERMA-Electronic GmbH 15

8. Technical Data 8. Technical Data 8.1. Electrical Data Digital input :max. 16 bit, parallel Logic :PNP, high-active Signal level :5 V, 12 V or 24 V Refresh time :ca. 300 ms Strobe signal duration :> 100 s Input code :BCD-, BINAR- or GRAY-Code programmable Power supply DC :18.. 36 V DC Current :max. 25 ma (red display) :max. 35 ma (green display) optional :12 V DC, ± 10 % :5 V DC, ± 10 % Isolation :500 V / 1 min 8.2. Mechanical Data Display :5-digit, 8 mm, red :Vornullenunterdrückung optional :green Display Housing :switchboard DIN 43 700 Dimensions (W x H x D) :48 x 24 x 107 mm Mounting depth :ca. 120 mm w/o plug Weight : ca. 200 g Connections : Flat cable-connector DIN 41 651 : 26-pin 8.3. Environment Temperature : 0.. 50 C Storage temperature : -20.. 70 C Relative humidity : < 80 %, not condensing Schutzart : Frontside IP 40 : Connector IP 20 CE : EG-Rules 89/336/EWG 16 ERMA-Electronic GmbH

9. Order information 9. Order information FA 2510- Input level 0 5 V 1 12 V 2 24 V Housing 0 Switchboard 1 Panel-Clip Front frame color 0 black 1 mouse grey RAL 7037 2 pebble grey RAL 7032 3 light grey RAL 7035 Front foil design 0 without front foil 1 Frontfoil ALU elox 2 Front foil RAL 7032 3 Front foil RAL 7035 Display color 0 red 1 green Power supply 0 5 V DC, ± 10 %, isolated 1 12 V DC, ± 10 %, isolated 2 18 bis 36 V DC, isolated Di men sions prin ting on the front: (e.g. mm², cm, cm³) Plea se spe ci fy with your order ERMA-Electronic GmbH 17

10. Notes 10. Notes 18 ERMA-Electronic GmbH

ERMA - Elec tro nic GmbH Max-Eyth-Str. 8 D-78194 Im men din gen Te le fon +49 (0)7462 2000 0 Fax +49 (0)7462 2000 29 email info@erma-elec tro nic.com Web www.erma-elec tro nic.com