Class I surge protection with sparkover gaps



Similar documents
DEHNshield Application-optimised multipole combined lightning current and surge arrester

SURGE PROTECTIVE DEVICES

CATALOGUE SURGE PROTECTION LOW VOLTAGE

wietap wietap Overvoltage Protection Tensions running high

Surge protection for emergency alarm systems

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

R.C.C.B. s two-pole LEXIC

5SV Residual Current Protective Devices

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Relés e Contatores de Estado Sólido SIRIUS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PHOENIX CONTACT - 01/2007

Surge Protection and Power Supply Units 2013 / 2014

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Safety technique. Emergency stop module BO 5988 safemaster

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Safety Relays ESM/ESM-F

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

TX OPEN RS232/485 module

Intersection Preassembled 19-inch Rack

How To Make A Power Meter Safe

Contact expander modules

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PHOENIX CONTACT Features

*.ppt 11/2/ :48 PM 1

Series 8146/5-V37 and Series 8150/5-V37

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Emergency lighting units EM powerled

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

Power Supplies 3. SDN-P DIN Rail Series

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RM4TG20 three-phase network control relay RM4-T - range V

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

E-STOP relays, safety gate monitors

instabus KNX / EIB System System E F G H

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

ADM1TE 5/30A DIN rail single phase two wire energy meter

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic overload relay EF19 and EF45

Contact expansion modules

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Redundancy Module QUINT-DIODE/40

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Thermistor motor protection

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Three-phase monitoring relay CM-PFE

Product and functional description

ACS-30-EU-EMDR-10-MOD

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PCS0100en Persy Control Services B.V. Netherlands

49 Series - Relay interface modules A. Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

E-STOP relays, safety gate monitors

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

80 Series - Modular timers 16 A. Features

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

E-STOP relays, safety gate monitors

38 Series - Relay interface modules A

Insulation resistance

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Operating Manual UWAPS-TINY Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MOTOR PROTECTIVE DEVICES

Feed-through terminal block - SSK 110 KER-EX

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

E-STOP relays, safety gate monitors

MINI MCR-SL-R-UI(-SP)

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Preset Counter signo 721

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

E-STOP relays, safety gate monitors

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Digital input modules

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Electronic overload relay EF65, EF96 and EF146

Instructions for Safe Use

Transcription:

for low-voltage supplies surge protection with sparkover gaps Lightning conductors with sparkover gap for lightning protection or equipotential bonding providing class I According to the requirements of class B (DIN VDE 0675 part 6, draft: Nov. 1989/A1: Mar 1996) and class I to IEC 61643-1 (Jan 2002), the lightning conductor at the transfer from interface 0 to 1 (to IEC 1312-1) is used as the lightning protection providing equipotential bonding. In combination with several lightning protectors, the surge protection is used in the mains forms TN, TT and IT. When lightning strikes, the triggered air gap protector provides the necessary equipotential bonding between the building lightning protection and the earthing system of the power supply. The use of a sparkover gap satisfies the inspection requirements for class B surge protection systems according to the VDEW (Association of German Power Stations) directive (1st ed., 1998). N-PE sparkover gap. The lines for this should be kept as short as possible. The triggered and blowout PU 1 TSG+ devices can be clipped to TS 35 rails in electrical cabinets or distribution boards. Owing to the emissions given off when the sparkover gap is tripped, a safety clearance of min. 100 must be maintained between this and any current-conducting components. Coordination The maximum permissible operating voltage Uc is 330 or 440 V AC. Decoupling from downstream class II (C) arresters is unnecessary because triggered sparkover gaps with a low sparkover voltage are used. Important: for Uc 330 V, PU II is used with 280 V and for Uc 440 V, the PU II with 470 V. Please follow the installation instructions. Checking operation, maintenance and approvals Electrical connection for building installation The PU 1 TSG 35 ka class I lightning arrester is connected between the phase conductors (L1, L2, L3) and N/PE. A Weidmüller PU 1 TS G is used to provide the N-PE sparkover gap. The lines for this should be kept as short as possible. The triggered and non-blowout PU 1 TSG devices can be clipped to TS 35 rails in electrical cabinets or distribution boards. The maximum permissible operating voltage Uc is 260 V AC. Decoupling from downstream class II (C) arresters is unnecessary because triggered sparkover gaps with a low sparkover voltage are used. Please follow the installation instructions. A visual check is necessary to ensure that PU 1 TSG and PU 1 TSG+ surge protection components are operating correctly. Besides signalling a mains power failure, the LED illuminates above 120 V AC to indicate the failure of the firing electronics. It is advisable to check frequently during stormy weather. The use of triggered sparkover gaps achieves a very low protection level of < 1.5 kv with high discharge currents. Depending on the cross-section of the line, the PU 1 TSG must be protected with a fuse of max. 125 A gl, the PU 1 TSG+ max. 250 A gl. The connection is designed for the following cross-sections: solid wire: 10... 35 2 stranded wire: 10... 25 2 The operating temperature range is 40 C... +85 C. The PU 1 TSG lightning arresters have UL and KEMA approval and are hence suitable for use worldwide. Electrical connection for industrial installations The PU 1 TSG+ /330 V or 440 V class I lightning arrester is connected between the phase conductors (L1, L2, L3) and N/PE. A Weidmüller PU 1 TSG is used to provide the PU 1 TSG+ Overall width 36 PU 1 TSG+ Overall width 18 Clearwater.10 Tech - Phone: 800.894.0412 - ax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com

for low-voltage supplies Protection in the TN-S-system Protection in the TT-system Protection acc. to IEC 1024-1, IEC 1312-1 Protection acc. to IEC 364-4-443 Protection acc. to IEC 1024-1, IEC 1312-1 Protection acc. to IEC 364-4-443 Lightning conductor class I eliminator II Equipment protection class III Lightning conductor class I eliminator II Equipment protection class III In contrast to conventional sparkover gaps, the Weidmüller PU 1 TSG+ and PU 1 TSG sparkover gaps operate with electronic triggering. This fires the sparkover gap at such an early point that the downstream class II (PU II series) arresters are relieved. Decoupling from downstream class II (C) arresters is unnecessary because triggered sparkover gaps with a low sparkover voltage are used. The PU 1 TSG+ and PU 1 TSG differ in terms of the follow current extinction. The PU 1 TSG+ distributes the arc drop voltage over several chambers. As soon as the total arc drop voltage exceeds the mains voltage flowing, the follow current is extinguished. In the PU 1 TSG the follow current extinction takes place at the next current zero of the mains voltage. Choke or conductor Integrated electronic trigger component U IND U ZÜND U VAR U ZÜND U VAR Lightning conductor class I eliminator class II Lightning conductor class I eliminator class II for PU BC / BCR N-PE Arrestor Cross-connection for 3 units PU BC Cross-connection for 4 units PU BC Cross-connection for 3 units PU BCR Cross-connection for 4 units PU BCR Cross-connection for 3 units PU BC+PU1TSG Cross-connection for 3 units PU BCR+PU1TSG Cross-connection for 1 unit PU BC/R+PU1TSG PU1TSG 1 8561230000 QB 36-3 1 8816090000 QB 36-4 1 8816100000 QB 54-3 1 8821720000 QB 54-4 1 8821710000 QB 36-3+1 1 8858360000 QB 54-3+1 1 8858340000 QB 36-1+1 1 8858350000.11

for low-voltage supplies with triggered sparkover gap encapsulated version no decoupling necessary thanks to trigger electronics suitable for networks with high short-circuit currents PU 1 TSG+ / 0.9 kv-330 V for use in industrial systems PU 1 TSG+ / 1.5 kv-440 V for use in industrial systems suitable for lightning protection classes I, II, III, IV 330 V voltage (AC) 440 V voltage (AC) max. continuous current, Uc (AC) 330 V continuous current, Uc (AC) 440 V continuous current, Uc (AC) Requirements class to IEC 61643-1 Lightning test voltage I imp (10/350 µs) with 25 As charge imp (10/350 µs) with 25 As charge imp (10/350 µs) 625 kj/m nergy, per path 625 kj/m nergy, per path Short-circuit current extinction without back-up fuse / 50 Hz current extinction without back-up fuse / 50 Hz current extinction without back-up fuse 150 ns e 150 ns e 250 A gl. 250 A gl. 900 V tion level Up (typical) 1500 V ion level Up (typical) Optical function indicator green LED nction indicator green LED nction indicator Colour black black Operating temperature, min./max. Storage temperature, min./max. Approvals e E198315;KEMA Clamping range (rating- / min. / max.) 2 Length x width x height 150 x 35 x 80 150 x 35 x 80 Version without teleco. contact PU1 TSG Plus 330 VAC 0,9kV 1 8561220000 PU1 TSG Plus 440 VAC 1,5kV 1 8561250000

for low-voltage supplies with triggered sparkover gap encapsulated version no decoupling necessary thanks to trigger electronics suitable for lightning protection classes I, II, III, IV PU 1 TSG 35 ka / 0.9 kv-260 V for use in building systems (L-N/PE) PU 1 TSG / 1.5 kv-260 V for use in building systems (N-PE) 230 V voltage (AC) 230 V voltage (AC) max. continuous current, Uc (AC) 260 V continuous current, Uc (AC) 260 V continuous current, Uc (AC) Requirements class to IEC 61643-1 Lightning test voltage I imp (10/350 µs) 35 ka with 17.5As charge imp (10/350 µs) with 25 As charge imp (10/350 µs) 305 kj/ω energy, per path 625 kj/ω energy, per path Short-circuit current extinction without back-up fuse 3 ka / 50 Hz current extinction without back-up fuse 500 A / 50 Hz current extinction without back-up fuse 1 µs ime 1 µs ime 125 A gl. 125 A gl. 900 V tion level Up (typical) 1500 V ion level Up (typical) Optical function indicator green LED nction indicator no ical function indicator Colour grey r grey r Operating temperature, min./max. Storage temperature, min./max. Approvals e E198315;KEMA Clamping range (rating- / min. / max.) 2 Length x width x height 91 x 18 x 63 91 x 18 x 63 Version without teleco. contact PU 1 TSG 35kA / 0,9kV 1 8561260000 PU 1 TSG 50kA / 1,5kV 1 8561230000

for low-voltage supplies with triggered sparkover gap encapsulated version no decoupling necessary thanks to trigger electronics suitable as N-PE arrester suitable for lightning protection classes I, II, III, IV PU 1 TSG+ 100 ka / 1.5 kv-260 V for use as N-PE arrester max. continuous current, Uc (AC) Requirements class to IEC 61643-1 Lightning test voltage I imp (10/350 µs) Short-circuit current extinction without back-up fuse Optical function indicator Colour Operating temperature, min./max. Storage temperature, min./max. Approvals e E198315;KEMA 230 V voltage (AC) 260 V continuous current, Uc (AC) 100 ka with 50 As charge imp (10/350 µs) 2500 kj/ω energy, per path 100 A 260 V/50 Hz ent extinction without back-up fuse 1 µs ime 100 A gl. 1500 V ion level Up (typical) no ical function indicator grey r Clamping range (rating- / min. / max.) 2 Length x width x height 50 / 6 / 50 90 x 36 x 63 Version without teleco. contact PU 1 TSG 100kA/ 1 8762020000

PU 1 TSG+ Innovations 2010/2011 B n This space-saving, encapsulated lightning arrester can switch mains follow currents and discharge currents of max. (10/350 μs). It enables installations in protective classes I and II. High degree of protection against short circuits, with max. back-up fuse of. This ensures safe installations anywhere around the globe. The pluggable arrester always guarantees proper readability. It also ensures that the shortest path is taken to the system's earth potential. The arrester's status display enables defective modules to be quickly located and replaced. The status can also be forwarded on to the control room by means of the remote alarm signals. The low protection level (1.5 kv) increases the dielectric strength in the main distributor; as a result, the connected devices are not damaged. PU I 3+1 TSG+ 11 14 12 L1 L2 L3 PE OK CHANGE OK CHANGE OK CHANGE T T T T PU I 3 TSG+ 11 14 12 L1 L2 L3 OK CHANGE OK CHANGE T T T OK CHANGE N PEN Control side Max. continuous voltage, UC (AC) Temporary surge - UTOV Requirement category acc. to IEC 61643-1 Rated discharge current I imp (10/350 µs) [L-PE] Rated discharge current I imp (10/350 µs) [N-PE] PE current IPE at UC Optical function indicator: Signalling contact Connection torque range Design Ambient temperature (operational) Storage temperature Standards 240 V 100 ka 160 kj/ohm 315A gl 240 V / 160 kj / Ohm 315 A gl Clamping range (rating- / min. / max.) 2 Length x Width x Height 97 x 144 x 72.5 97 x 108 x 72.5 PU I 3+1 TSG+ 350V 1.5kV 1 8960510000 PU I 3 TSG+ 350V 1.5kV 1 8960490000 Plug-in spare arrester: PU I 0 N/PE TSG+ 350V 1066040000

PU 1 TSG+ This space-saving, encapsulated lightning arrester can switch mains follow currents and discharge currents of max. (10/350 μs). It enables installations in protective classes I and II. High degree of protection against short circuits, with max. back-up fuse of. This ensures safe installations anywhere around the globe. The pluggable arrester always guarantees proper readability. It also ensures that the shortest path is taken to the system's earth potential. The arrester's status display enables defective modules to be quickly located and replaced. The status can also be forwarded on to the control room by means of the remote alarm signals. The low protection level (1.5 kv) increases the dielectric strength in the main distributor; as a result, the connected devices are not damaged. PU I 1+1 TSG+ 11 14 12 L1 PE OK CHANGE T T PU I 1 TSG+ 11 14 12 L1 T OK CHANGE Innovations 2010/2011 B n N PEN Control side Max. continuous voltage, UC (AC) Temporary surge - UTOV Requirement category acc. to IEC 61643-1 Rated discharge current I imp (10/350 µs) [L-PE] Rated discharge current I imp (10/350 µs) [N-PE] PE current IPE at UC Optical function indicator: Signalling contact Connection torque range Design Ambient temperature (operational) Storage temperature Standards 240 V / 100 ka 160 kj/ohm 315 A gl 240 V 160 kj / Ohm 315 A gl Clamping range (rating- / min. / max.) 2 Length x Width x Height 97 x 72 x 72.5 97 x 36 x 72.5 PU I 1+1 TSG+ 350V 1.5kV 1 8960500000 PU I 1 TSG+ 350V 1.5kV 1 8960480000 Plug-in spare arrester: PU I 0 N/PE TSG+ 350V 1066040000