IN-BODY RF COMMUNICATIONS AND THE FUTURE OF HEALTHCARE



Similar documents
Selecting Receiving Antennas for Radio Tracking

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Consequence for a dualband application

EH-20 20m antenna. By VE3RGW

RFID Receiver Antenna Project for Mhz Band

Wireless Medical Telemetry Laboratory

Antenna Basic Concepts

Internal GPS Active Patch Antenna Application Note

Antenna Properties and their impact on Wireless System Performance. Dr. Steven R. Best. Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

Application Note AN-00126

Byonics Micro Trak 1000 High Altitude Balloon Tracker

WIRELESS INSTRUMENTATION TECHNOLOGY

Understanding Range for RF Devices

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Design and Certification of ASH Radio Systems for Japan

Just a Dipole. Gary Wescom N0GW July 16, 2007

How To Design An Ism Band Antenna For 915Mhz/2.4Ghz Ism Bands On A Pbbb (Bcm) Board

Human Exposure Limits

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

IN-OUT Thermometer with Cable Free Sensor and Clock

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

1. INTRODUCTION. There are different frequency bans according to the range of frequencies shown: 1.1 Electromagnetic Spectrum

Unidirectional Transmitter/ Receiver Units Introduction

RF Safety Compliance and Duty Cycle for OpenWay CENTRON 4G-LTE Meters December 2015

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

Introduction to Z-Wave. An Introductory Guide to Z-Wave Technology

Application Note AN-00125

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Wireless Medical Devices

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Technician Licensing Class

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

Pillbox Antenna for 5.6 GHz Band Dragoslav Dobričić, YU1AW

Design of an U-slot Folded Shorted Patch Antenna for RF Energy Harvesting

Signal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam

LT-82 Stationary IR Transmitter

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

RF safety at base station sites

ELEMENTS OF CABLE TELEVISION

Antenna Glossary Before we talk about specific antennas, there are a few common terms that must be defined and explained:

Antenna Deployment Technical Brief

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

AN INTRODUCTION TO TELEMETRY PART 1: TELEMETRY BASICS

Totally Wireless Video Security

75 Ω Transmission System

Omni Antenna vs. Directional Antenna

DAB Digital Radio Broadcasting. Dr. Campanella Michele

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Wireless Power for Remote Monitoring Applications

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Wireless RF Distribution in Buildings using Heating and Ventilation Ducts

Wireless Broadband: Health & Safety Information

Selecting a Transmission Line for Your Broadcast System

2/20/ Transmission Lines and Waveguides.doc 1/3. and Waveguides. Transmission Line A two conductor structure that can support a TEM wave.

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

EMC Standards: Standards of good EMC engineering

FILTERS - IN RADIO COMMUNICATIONS

Application Note Noise Frequently Asked Questions

An octave bandwidth dipole antenna

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Coaxial Cable Feeder Influence on Yagi Antenna Dragoslav Dobričić, YU1AW

Designing Log Periodic Antennas

AM / FM Tuner + RDS. Model: TU

Cellular Wireless Antennas

Application Note TDx510x

Design of a Planar Omnidirectional Antenna for Wireless Applications

LDG RBA-4:1Balun LDG RBA-1:1Balun

V0910 SENNSIS. Making Your Tour. State of the Art. TourGuide 2020-D

DL-QRP-AG Lambda/2 no Counterpoise: Fuchs Antenna matching unit

ZigBee Propagation for Smart Metering Networks

Franz Hirtenfelder and Stephen Murray, CST Computer Simulation Technology and W. L. Gore and Associates (Gore) March 5, 2015

Mobile use, radio signals and health

Turbo X channel UHF true diversity

Understanding SWR by Example

ÇANKAYA ÜNİVERSİTESİ ECE 491 SENIOR PROJECT I ERDİNÇ YILMAZ

Embedded FM/TV Antenna System

RADIATION PATTERNS. The half-power (-3 db) beamwidth is a measure of the directivity of the antenna.

40m-10m DELTA LOOP ANTENNA - GU3WHN

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Capacitor Self-Resonance

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi , China

Design Considerations for RF Energy Harvesting Devices

Water Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System

communication over wireless link handling mobile user who changes point of attachment to network

Mine Communications in the 21 st Century

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

EE302 Lesson 14: Antennas

RECOMMENDATION ITU-R SM Measuring sideband emissions of T-DAB and DVB-T transmitters for monitoring purposes

SmartDiagnostics Application Note Wireless Interference

URINARY INCONTINENCE

How To Understand The Power Of An Freddi Tag (Rfid) System

APPLICATION NOTES POWER DIVIDERS. Things to consider

Transcription:

IN-BODY RF COMMUNICATIONS AND THE FUTURE OF HEALTHCARE Henry Higgins Microelectronics Business Division Zarlink Semiconductor In-body communications have the potential to dramatically change the future of healthcare. Integrated communications from different in-body implants and on-body sensors will allow hearing for the deaf, sight for the blind, and mobility for the disabled. In-body communications will also improve therapy and diagnoses. For example, an implanted pacemaker will regularly transmit performance data and the patient s condition to a clinician s office. If the pacemaker detects a cardiac arrest, the device could signal immediately to a base station to alert an emergency response team. Thanks to its high data rate and low power consumption, advances in Radio Frequency (RF) technology are supporting these healthcare advances. A key element of an RF-linked implant is the inbody antenna, which must meet stringent biocompatible and size-limit requirements. An implanted transceiver also faces numerous RF challenges. Unlike free-air performance, the human body is often an unpredictable and hostile environment for a wireless signal. RF-linked implants are already in use for a wide variety of applications, and there are numerous new devices currently in development aimed at improving quality of life for patients. For some applications, such as Cochlear hearing implants, the communication needs to be constant. Others, such as pacemakers or bladder control devices, require brief, infrequent data transfer. Regardless of the communication requirements, limited power consumption and space are both critical design factors. BODY EFFECTS ON RF TRANSMISSION Before considering any in-body data transmission, the effects of the human body on the RF signal must be understood. Unlike the usual communication through constant air, the various tissues and organs within the body have their own unique conductivity, dielectric constant and characteristic impedance. As a result, signal level and propagation from an implanted device to a remote receiver is unpredictable. Typical values for the electrical properties of muscle and fat are shown in Table 1. Not only will these values vary from person to person, they will also change as a patient moves, changes weight and ages. The high dielectric constant (εr) works to advantageously reduce the physical size of any antenna. Table 1: Human Dielectric Constant (ε r ), Conductivity (σ) and Characteristic Impedance (Zo) vs. Frequency. (Source FCC and Dr. William Scanlon, Queens University of Belfast)

Frequency bands and power levels are regulated by the Medical Implant Communication Service (MICS) band (1). MICS operates in the 402-405 MHz band, with a power level strictly limited to 25µW of effective radiated power (ERP). For an implant, ERP is defined as the signal measured external to the body and not at the implant. This allows the implant itself to operate at a higher power. ERP for an external base station is measured at the transmitting antenna, so the signal at the implant is the sum of a low transmitted power, antenna gain, transmission losses and the high body losses. The base station-tobody path results in the lowest received signal. The losses through the body come from attenuation by the weakly conductive tissue and reflection at each of the boundries of dissimilar tissue. A loss in the order of 20 db is typical, but can be compensated for if the implant is transmitting at a higher power than the external 25 µw limit. On the receive end, the power limit is at the base station transmitter. As the distance between the base station and implant may be three meters, the result is a low signal level at the implant. This puts strain on the link budget. ANTENNA DESIGN The high dielectric constant enables an antenna to be electrically larger than it would be in free space. For example, in free space a half wave dipole operating at 403 MHz would be 372 mm long. However, in muscle with an εr of 47, the size is reduced to 54 mm. A dipole needs to be separate from the implant for best operation, however this is not always an acceptable option. Electrically small antennas have several drawbacks, such as poor efficiency, low radiation resistance, narrow bandwidth and a high Q that makes them more difficult to manufacture. A physically small antenna must be used in an implant application. The shape of the implant will also dictate the type of antenna used. A patch antenna may be suitable for a pacemaker application, while a helix antenna is required for a stent or urinary tract implant. A patch antenna can be incorporated into the shape of the implant and works with a 0V RF backplane. An ideal shape is λ/2, which in free space at 403 MHz translates into an antenna measuring 372 mm. This dimension can be reduced by use of a substrate with a high dielectric constant, such as alumina (εr = 9.6), zirconia (εr =25) or titainia (εr =50 to 85). The conductor needs to be biocompatible, even if the implant is coated in a passive material. For longterm use, this limits the choice of material to platinum or platinum/iridium, both of which have low conductivity compared to copper, gold or silver. Gold can be used for short-term applications. The shape of a patch is defined by the implant case, as it is not acceptable to have sharp overhanging corners that could cause injury. Given the shape of the patch, the substrate material must be low loss but high dielectric constant. This is to maximize the radiation resistance compared with the conductor loss. Radiation resistance can be measured with a patch immersed in a body phantom; a perspex cylinder filled with a liquid that mimics the electrical properties of muscle(3). (Figure 1) The feed point can be altered to change the input impedance but the patch should not be tuned to resonate at the required frequency. Operating at resonance will increase the efficiency, however this frequency will change as the antenna is immersed in the body phantom. The input impedance is measured with a 0.25λ line, as the radiation resistance is so low that network analyzer measurements are unreliable. Once the antenna impedance range is established, a matching network can be designed. Part of this network should include fine-tuning capabilities within the transceiver. Figure 1: A body phantom is used to test in-body antenna performance

Radiation patterns are made with the body phantom using a self-contained transmitter immersed in the liquid. If the antenna were to be attached to a cable then it would contribute to the radiation pattern. This can be minimized, but not eliminated, with the addition of ferrite beads. The patch attached to an implant case within a body does not have an earth (ground) connection, meaning the case will radiate in anti-phase to the patch. This requires that the patch and case be self-powered and measured as a whole. The RF feed for the patch is an important consideration, as the case and feed-through must form an impenetrable seal. Feeding the patch through a hole in the substrate (Figure 2) would require a feedthrough flat with the upper surface of the case. This would be difficult to implement. An alternative is to use a co-axial feed-through to connect to the patch, similar to those used for other applications such as heart stimulation. (Figure 3) Figure 2: An RF feed-through via a hole in the substrate Figure 3: Using a co-axial feed-through to connect to the patch Patch antennas are not always suitable; consider an RF-controlled valve for bladder control. The valve, electronics, battery and antenna must all fit into a tube 4-6 mm in diameter. The valve is fitted, without surgery, into the urethra and needs to be changed approximately every 60 days. Clearly a flat rectangular patch is not an option, however the tube shape of the valve can be used as the basis for a helical antenna. (Figure 4)

Figure 4: A helical antenna used for RF-based bladder control Each application is liable to need a different antenna that should be designed together with the case, and not as an add-on device. IMPLANT TRANSCEIVER If operated continuously, a transceiver will consume significant current and reduce the operating life of the implant. This would require either a method for recharging the battery by an inductive loop approach, or regular replacement of the implant. Both of these have drawbacks, but may be necessary for applications such hearing restoration. In some applications, such as pacemaker monitoring, the transceiver only operates intermittently and for short periods. During the interval between communication sessions, the transceiver can be put into sleep mode where it draws only a very tiny current but will sense a wake-up signal. The wake-up is generated by the external base station, after which data can be transferred. At each wake-up the transceiver should retune the antenna. Following the transfer, the implant transceiver returns to sleep mode. This considerably extends battery life. The transceiver can operate in a wake-up mode, as described above, or can initiate communication by sending a message to a nearby base station. The use of this mode is limited, but could be useful for providing an early warning that battery life is low. Potentially, an implant could also transmit an emergency signal if it detects a health problem, such as cardiac arrest. When designing an implant transceiver that relies on a wake-up signal, each device must have its own unique identifier. This ensures the correct device is being interrogated, or the right patient is being treated, in a busy hospital setting. APPLICATIONS The transceiver can be integrated with a range of implants for a variety of different uses, including heart pacemaker monitoring, bladder control and Functional Electrical Stimulus (FES). These three applications can use the same transceiver with a choice of antennas. The performance of a pacemaker can be improved with remote monitoring and re-programming as required. For example, battery status can be transmitted to a base station to provide an early warning of power loss or increase the time between surgical replacement. This application requires a large data transfer in a relatively short time. The data can be stored for several days or weeks before transmission. Fitting into the urinary tract a radio-controlled valve that is operated on-demand by the patient or a caregiver can restore bladder control. This can greatly improve the quality of life for an otherwise

incontinent patient. This type of link will require a small data transfer at regular, widely spaced, intervals. A unique identifier as part of the data link will activate the correct patient s valve. Using FES to replace lost limb function, for example paralysis as a result of a stroke, requires implant(s) to stimulate muscles or nerves in response to movement detected by sensors elsewhere on the body. (Figure 5) Figure 5: A patient with external sensors transmitting data to a processor pack. Information is then relayed to an implant to activate a muscle. The patient wears a strap-on motion sensor that transmits data to a processor pack, which is worn by the patient and is similar to a mobile phone. The sensor transmits over a short distance (less than two meters), without the problems or limitations of in-body transmission. Since the device is not an implant, a frequency with a higher power level can be used, such as the Industrial Scientific Medical (ISM) bands. Operating in real-time, the processor receives signals from the sensors, processes the data and transmits it to the implants to stimulate a muscle or nerve. The processor may have inputs from several sensors and transmit signals to several stimulus implants. The link to the in-body implant will use the MICS frequency, with the implant using an antenna mounted on its case as described above. The on-body sensor battery is charged overnight or replaced when necessary. The processor will have a battery capacity to operate throughout the day and can be recharged overnight. Because the implant transceiver will be used for long periods the battery needs to be capable of overnight charging through an inductive loop. A patient using FES may have several RF-linked implants. To ensure the base station is communicating with the correct device, each implant transceiver must have a unique identifier to prevent false wake-up or interrogation. CONCLUSIONS RF-linked implants can be used for diagnosis, therapy or to restore lost function. Each application will need to be tailored to the position and frequency of use. A key component of an in-body communications system is the antenna. The antenna must be designed as part of the implant, and not as an add-on or after-thought as this will lead to performance issues.

The use of RF technology in medical applications promises many benefits for patients, including better diagnoses and tailored therapy, fewer hospital visits, and peace of mind that implant performance is being monitoring. For healthcare providers, improved implant monitoring potentially lowers medical costs by extending the time between hospital visits and surgical procedures. We are only just beginning to realize the potential for RF communications in healthcare. Henry Higgins is with Zarlink s Microelectronics division, and is involved in the design and development of RF links for medical applications that included synthesizer, modulator, amplifier blocks and antennas. Henry holds a Master of Science degree from the University of Bath, and is a corporate member of the IEE. ACKNOWLEDGMENT Part of the work described here is funded by the EU Framework 6 Healthy Aims programme. REFERENCES 1. MICS Band. Australian Communications Agency paper SP 6/03, October 2003 2. ISM Band. Federal Communications Com mission, Title 47 Volume 1, Telecommunications Section, Part 18, Industrial Scientific and Medical Equipment, Sub Part C, Section 18.305. 3. Wojclk J et. al.; Tissue Recipe Calibration Requirements, SSI/DRB-TP-D01-003. Spectrum Sciences Institute RF Dosemetry Research Board, 51 Spectrum Way, Nepean, Ontario, K2R 1E6 Canada.