PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470 8855 Email support@spheresystems.com.au Internet www.spheresystems.com.au
2 Oct 14 Table of Contents PRICE LIST... 1 Facility DDC Access WebXL DDC... 1 Facility DDC... 3 Facility DDC Software...3 Field Control Solutions...4 Power Supplies...5 Expansion Modules...5 Network Controllers & Devices...6 Field Devices...7 Field Devices cont....8 Facility Interfaces...8 Facility Access... 9 Facility Access Software...9 Field Control Solutions...9 Facility Access...10 Power Supplies & Battery Backup...10 Network Controllers & Devices...10 Door-Com & Lift-Com Expansion Modules...11 WebXL DDC... 12 WebXL Field Control Solutions...12 WebXL Add On Applications...12 Web Alarm... 12 Web Server Alarm System...12 Sphere Systems Pty Ltd (03) 9470 8844 www.spheresystems.com.au 2
3 Facility DDC Facility DDC Software Facility DDC v3.1 With Power32, Plant Drawings and Wiring Plans Total Control Server Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Facility DDC v3.1 Lite With Plant Drawings and Wiring Plans Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Maximum 200 points Facility DDC Client License Run Facility DDC on a separate computer Allows Full Control of DDC Requires a Facility DDC Server Installation Compatible with Windows 7 and 8 Facility DDC v3.1 Software Upgrade Upgrade Facility DDC to the latest version Upgrade only Requires a previous version of Facility DDC Compatible with Windows 7and 8 Online Viewer Use Internet Explorer to view Facility DDC Drawings View Current Alarms Requires a Facility DDC Installation Compatible with Windows 7and 8 001040 001045 001041 001046 001039 3
4 Facility DDC Field Control Solutions MC311 Minicom 8 universal (analogue or digital) inputs. 4 digital outputs and 4 universal outputs. Inputs & Outputs expandable up to 40 points. Stand-Alone or Network controlled. Digicom Consists of Digital Points Only 8 digital inputs & 8 digital outputs Expandable to 48 Dig Inputs & 48 Dig Outputs Stand-Alone or Network controlled. Powercom Operate within your Maximum Demand. Reduce your energy costs with Load Shedding. Built for kw, kva, kvar and Power Factor Stand-Alone or Network controlled. Metercom Logging for multiple meters and sub-metering. Data logging and energy reports Accepts meter pulses for kw, kvar and sync Stand-Alone or Network controlled. 001001 001004 001002 001003 4
5 Facility DDC Power Supplies Expansion Modules Power Supply Module Power pack to suit MC311 boards 16 Volt AC Input +/- 15 Volt DC Output 2 Amp Battery Charging Module 7.2 AHr battery charging suit MC311 boards 16 Volt AC Input +/- 15 Volt DC Output 2 Amp Relay Expansion Card Relay adapter board to suit MC311 Provides 8 volt-free relays Over-ride ride jumpers Max switching current is 10 Amp DC or 5 Amp AC. Analogue Input Card 8 Analogue Inputs 12 bit resolution Input must be 0-10 Volt DC or 5-20mA Analogue Output Card 8 Analogue Outputs 12 bit resolution Output must be 0-10 Volt DC or 5-20mA Digital Input Card 8 Digital Inputs Volt-Free Contact Closure Inputs Open-circuit voltage of 8 to 12 Volts DC Led input detection Digital Output Card 8 Digital Outputs Volt-free relays with a normally closed contact Max switching current is 24 Volt AC or 5 Amp DC Led output indicator 001005 001055 001006 001009 001010 001011 001012 5
6 Facility DDC Network Controllers & Devices DP44 DP44 Network processor with Ethernet Controls RS485 network of field processors Connects to PC via Ethernet connection Uses UDP Protocol Repeater RS485 based network repeater Extend the length of a RS485 line Use to create a 'star' network configuration A 4 wire (2 pair) RS485 cable is required 001056 001017 6
7 Facility DDC Field Devices Active Room Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Pipe Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Duct Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Current Loop Room Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Current Loop Duct Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Current Loop Pipe Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Active Pipe Sensor -50 to + 50 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Pipe Sensor -25 to + 75 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Duct Sensor -25 to + 75 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire 003001 003002 003003 003010 003012 003013 003015 003016 003017 7
8 Facility DDC Field Devices cont. SZ MicroZone Wall mount LCD Single Zone LCD Displays Actual Temperature Set point change and On/Off Switching SZT MicroZone Wall mount LCD Single Zone LCD with Temperature Sensor Displays Actual Temperature Set point change and On/Off Switching MZ MicroZone Wall mount LCD Multi Zone LCD Displays Actual Temperature Set point change and On/Off Switching Connect up to 8 MZ or SZ on one network MF MicroZone Wall mount LCD Multi-Function LCD Temperature, Humidity and set point display On/Off f switching, Fan Speed control Supports Heating & Cooling Modes 003030 003031 003032 003033 Facility Interfaces Modbus - Facility Interface Interface any Modbus Device to Facility DDC Map Modbus registers to Facility DDC Points Supports Modbus RTU Interfaces points and alarms G50 Facility Interface Interface Facility and Mitsubishi G50A Controller Provides full control and feedback Map G50A points on Facility via XML 001069 001066 8
9 Facility Access Facility Access Software Door-Trol Software Complete Door, Lift control with Alarms Total Control Server Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Door-Trol Client License Run Facility Door-Trol on a separate computer Allows Full Control of system Requires a Facility Door-Trol Server Installation Compatible with Windows 7 and 8 Door-Trol Software Upgrade Upgrade Facility Door-Trol to the latest version Upgrade only Requires a previous version of Facility Door-Trol Compatible with Windows 7 and 8 002040 002041 002042 Field Control Solutions Doorcom DC390B I/O expandable door controller Supports Proximity, i-button and Weigand readers Contains up to 1500 Users 32 Timeclock functions 002001 Liftcom LC390B I/O Expandable Lift Controller Reports back access and destinations Contains up to 1500 Users Memory module required after 16 floors 002002 9
10 Facility Access Power Supplies & Battery Backup Plug Pack 16V AC 240 Volt AC Input 16 Volt AC Output Doorcom Battery Box 002016 Complete DoorCom housing 300 x 250 mm 7.2 Amp Hour battery and power supply DoorCom not Included 002017 Network Controllers & Devices DP44 Network processor DP44 Network processor with Ethernet Controls RS485 network of field processors Connects to PC via Ethernet connection Uses UDP Protocol Repeater module RS485 based network repeater Extend the length of a RS485 line Use to create a 'star' network configuration A 4 wire (2 pair) RS485 cable is required 001056 001017 10
Door-Com & Lift-Com Expansion Modules Digital Input Card 8 Digital Inputs Volt-Free Contact Closure Inputs Open-circuit voltage of 8 to 12 Volts DC Led input detection Analogue Input Card 8 Analogue Inputs 12 bit resolution Input must be 0-10 Volt DC or 5-20mA Digital Output Card 11 8 Digital Outputs Volt-free relays with a normally closed contact Max switching current is 24 Volt AC or 5 Amp DC LED output indicator Memory expansion module Battery backed memory expansion Used with Doorcom and Liftcom Allows over 1500 Users per door Facility Access 001011 001009 001012 002009 11
12 WebXL DDC WebXL Field Control Solutions WebXL 2 Controller Complete HVAC system Up to 128 Points per controller No software registration Uses Internet Explorer 001060 WebXL IO Module 8 Analogue and 8 Digital Inputs 8 Analogue and 8 Digital Outputs Variety of all points Can Support 4 I/O per Controller 001061 WebXL Binary IO Module 16 Digital Inputs 16 Digital Outputs Completely Digital Card Can Support 2 Binary I/O per Controller 001064 WebXL Dual I/O Module 2 Analogue and 2 Digital Inputs 2 Analogue and 2 Digital Outputs Low Cost I/O Can Support 16 Dual I/O per Controller 001065 WebXL G50 Interface Interface WebXL and Mitsubishi G50A Controller Provides full control and feedback Map G50A points on WebXL via XML WebXL Add On Applications Online Room Booking System Book Rooms up to 6 months in advance Use with WebXL to control only occupied rooms Totally Web Based Requires a PC with network connectivity LogXL Log any WebXL point Graph, view or download data Totally Web Based Requires a PC with network connectivity 001073 PowerXL 001067 001072 Log Electricity, Gas and Water meters Graph, view or download logged data Calculate KVA and Power Factor Requires a PC with network connectivity 001074 12
13 Web Alarm Web Alarm Solutions Web Alarm 16 Complete Web Based alarm Panel Up to 16 binary Points No software registration Uses browser to configure 006016 Web Alarm 88 Complete Web Based alarm Panel Up to 8 binary Points and 8 Analogue Points 0-10V No software registration Uses browser to configure 006088 13
14 Sphere Systems Pty Ltd (03) 9470 8844 www.spheresystems.com.au 14