PRODUCT LIST Facility DDC Access WebXL DDC



Similar documents
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Temperature & Humidity SMS Alert Controller

Data Loggers for Real Time Temperature Monitoring - WiFi

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EDI Distributor Control Interface Wiring and Setup Instructions

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.


ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Metering for today s systems

EQUIPMENT SPECIFICATIONS

SCADA and Monitoring for Solar Energy Plant

SMS GSM Alarm Messenger

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

USB-500 Series Stand-Alone, Low-Cost Data Loggers

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

HyperAccess Access Control System

A project to optimise quality and energy efficiency must include metering

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

ACCESS CONTROL SYSTEM

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

WiFi Edition

HERZ-Thermal Actuators

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Technical Overview CM-2 Climate Monitor. Get yours direct at:

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

OZW30. Central Unit SYNERGYR

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Functional Specification Document

T7560A,B,C Digital Wall Module

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

A C C E S S C O N T R O L S Y S T E M

Computer Cabinet Environment Monitor

Digital and Analog I/O

Uninterruptible Power Supply

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Integrated Building Management and Security System. Building Automation & Security.

FIREDEX Conventional Fire Panels

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Electronic Control Devices The European Product Catalogue 2007

Programming Logic controllers

minova technology electronics

NC-12 Modbus Application

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Using installed Fieldbus Wiring to carry Ethernet Communications

Doc 10. UTM Standards: Card Access Security System

1 Application Description Objective Goals... 3

HWg-STE HWg-STE PoE MANUAL

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Power Proportional Distribution (PPD)

Inwall Room Temperature Unit

Temperature Alert. LAN-based Temperature and Humidity Data Logger

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Zertico Rack Monitoring Unit

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

IntesisBox Modbus Server - Mitsubishi Electric G50

FX07 Field Controller

PROBA 4. In control of banana ripening. World leaders in process control.

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Remote Monitoring and REC 501 Control Unit Product Guide

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Building Automation System BAS-2000 Series

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n

M2M/IoT Solutions.

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Section TELEPHONE AUTOMATIC DIALER SYSTEM

PCS0100en Persy Control Services B.V. Netherlands

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product overview mm. 100 mm

TAC I/NETTM. Process Control Unit

Workshop 7 PC Software - Tracker

Electronic Control Devices The European Product Catalogue 2007

Model: DC-A2IO Advanced HVAC Controller

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

scalable data centre energy management solution

NETWORK ENABLED EQUIPMENT MONITOR

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Duct Humidity Transmitter

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

Model #: SMART2200CRMXL

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Transcription:

PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470 8855 Email support@spheresystems.com.au Internet www.spheresystems.com.au

2 Oct 14 Table of Contents PRICE LIST... 1 Facility DDC Access WebXL DDC... 1 Facility DDC... 3 Facility DDC Software...3 Field Control Solutions...4 Power Supplies...5 Expansion Modules...5 Network Controllers & Devices...6 Field Devices...7 Field Devices cont....8 Facility Interfaces...8 Facility Access... 9 Facility Access Software...9 Field Control Solutions...9 Facility Access...10 Power Supplies & Battery Backup...10 Network Controllers & Devices...10 Door-Com & Lift-Com Expansion Modules...11 WebXL DDC... 12 WebXL Field Control Solutions...12 WebXL Add On Applications...12 Web Alarm... 12 Web Server Alarm System...12 Sphere Systems Pty Ltd (03) 9470 8844 www.spheresystems.com.au 2

3 Facility DDC Facility DDC Software Facility DDC v3.1 With Power32, Plant Drawings and Wiring Plans Total Control Server Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Facility DDC v3.1 Lite With Plant Drawings and Wiring Plans Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Maximum 200 points Facility DDC Client License Run Facility DDC on a separate computer Allows Full Control of DDC Requires a Facility DDC Server Installation Compatible with Windows 7 and 8 Facility DDC v3.1 Software Upgrade Upgrade Facility DDC to the latest version Upgrade only Requires a previous version of Facility DDC Compatible with Windows 7and 8 Online Viewer Use Internet Explorer to view Facility DDC Drawings View Current Alarms Requires a Facility DDC Installation Compatible with Windows 7and 8 001040 001045 001041 001046 001039 3

4 Facility DDC Field Control Solutions MC311 Minicom 8 universal (analogue or digital) inputs. 4 digital outputs and 4 universal outputs. Inputs & Outputs expandable up to 40 points. Stand-Alone or Network controlled. Digicom Consists of Digital Points Only 8 digital inputs & 8 digital outputs Expandable to 48 Dig Inputs & 48 Dig Outputs Stand-Alone or Network controlled. Powercom Operate within your Maximum Demand. Reduce your energy costs with Load Shedding. Built for kw, kva, kvar and Power Factor Stand-Alone or Network controlled. Metercom Logging for multiple meters and sub-metering. Data logging and energy reports Accepts meter pulses for kw, kvar and sync Stand-Alone or Network controlled. 001001 001004 001002 001003 4

5 Facility DDC Power Supplies Expansion Modules Power Supply Module Power pack to suit MC311 boards 16 Volt AC Input +/- 15 Volt DC Output 2 Amp Battery Charging Module 7.2 AHr battery charging suit MC311 boards 16 Volt AC Input +/- 15 Volt DC Output 2 Amp Relay Expansion Card Relay adapter board to suit MC311 Provides 8 volt-free relays Over-ride ride jumpers Max switching current is 10 Amp DC or 5 Amp AC. Analogue Input Card 8 Analogue Inputs 12 bit resolution Input must be 0-10 Volt DC or 5-20mA Analogue Output Card 8 Analogue Outputs 12 bit resolution Output must be 0-10 Volt DC or 5-20mA Digital Input Card 8 Digital Inputs Volt-Free Contact Closure Inputs Open-circuit voltage of 8 to 12 Volts DC Led input detection Digital Output Card 8 Digital Outputs Volt-free relays with a normally closed contact Max switching current is 24 Volt AC or 5 Amp DC Led output indicator 001005 001055 001006 001009 001010 001011 001012 5

6 Facility DDC Network Controllers & Devices DP44 DP44 Network processor with Ethernet Controls RS485 network of field processors Connects to PC via Ethernet connection Uses UDP Protocol Repeater RS485 based network repeater Extend the length of a RS485 line Use to create a 'star' network configuration A 4 wire (2 pair) RS485 cable is required 001056 001017 6

7 Facility DDC Field Devices Active Room Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Pipe Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Duct Sensor 0-100 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Current Loop Room Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Current Loop Duct Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Current Loop Pipe Sensor 0-100 deg C or 0-50 deg C 15 Volt DC Input Linear current temperature output. 2 wire Active Pipe Sensor -50 to + 50 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Pipe Sensor -25 to + 75 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire Active Duct Sensor -25 to + 75 deg C 24 Volt DC Input 0 10 Volt DC Output 3 wire 003001 003002 003003 003010 003012 003013 003015 003016 003017 7

8 Facility DDC Field Devices cont. SZ MicroZone Wall mount LCD Single Zone LCD Displays Actual Temperature Set point change and On/Off Switching SZT MicroZone Wall mount LCD Single Zone LCD with Temperature Sensor Displays Actual Temperature Set point change and On/Off Switching MZ MicroZone Wall mount LCD Multi Zone LCD Displays Actual Temperature Set point change and On/Off Switching Connect up to 8 MZ or SZ on one network MF MicroZone Wall mount LCD Multi-Function LCD Temperature, Humidity and set point display On/Off f switching, Fan Speed control Supports Heating & Cooling Modes 003030 003031 003032 003033 Facility Interfaces Modbus - Facility Interface Interface any Modbus Device to Facility DDC Map Modbus registers to Facility DDC Points Supports Modbus RTU Interfaces points and alarms G50 Facility Interface Interface Facility and Mitsubishi G50A Controller Provides full control and feedback Map G50A points on Facility via XML 001069 001066 8

9 Facility Access Facility Access Software Door-Trol Software Complete Door, Lift control with Alarms Total Control Server Stand-alone alone & RS485 Network compatible Compatible with Windows 7 and 8 Door-Trol Client License Run Facility Door-Trol on a separate computer Allows Full Control of system Requires a Facility Door-Trol Server Installation Compatible with Windows 7 and 8 Door-Trol Software Upgrade Upgrade Facility Door-Trol to the latest version Upgrade only Requires a previous version of Facility Door-Trol Compatible with Windows 7 and 8 002040 002041 002042 Field Control Solutions Doorcom DC390B I/O expandable door controller Supports Proximity, i-button and Weigand readers Contains up to 1500 Users 32 Timeclock functions 002001 Liftcom LC390B I/O Expandable Lift Controller Reports back access and destinations Contains up to 1500 Users Memory module required after 16 floors 002002 9

10 Facility Access Power Supplies & Battery Backup Plug Pack 16V AC 240 Volt AC Input 16 Volt AC Output Doorcom Battery Box 002016 Complete DoorCom housing 300 x 250 mm 7.2 Amp Hour battery and power supply DoorCom not Included 002017 Network Controllers & Devices DP44 Network processor DP44 Network processor with Ethernet Controls RS485 network of field processors Connects to PC via Ethernet connection Uses UDP Protocol Repeater module RS485 based network repeater Extend the length of a RS485 line Use to create a 'star' network configuration A 4 wire (2 pair) RS485 cable is required 001056 001017 10

Door-Com & Lift-Com Expansion Modules Digital Input Card 8 Digital Inputs Volt-Free Contact Closure Inputs Open-circuit voltage of 8 to 12 Volts DC Led input detection Analogue Input Card 8 Analogue Inputs 12 bit resolution Input must be 0-10 Volt DC or 5-20mA Digital Output Card 11 8 Digital Outputs Volt-free relays with a normally closed contact Max switching current is 24 Volt AC or 5 Amp DC LED output indicator Memory expansion module Battery backed memory expansion Used with Doorcom and Liftcom Allows over 1500 Users per door Facility Access 001011 001009 001012 002009 11

12 WebXL DDC WebXL Field Control Solutions WebXL 2 Controller Complete HVAC system Up to 128 Points per controller No software registration Uses Internet Explorer 001060 WebXL IO Module 8 Analogue and 8 Digital Inputs 8 Analogue and 8 Digital Outputs Variety of all points Can Support 4 I/O per Controller 001061 WebXL Binary IO Module 16 Digital Inputs 16 Digital Outputs Completely Digital Card Can Support 2 Binary I/O per Controller 001064 WebXL Dual I/O Module 2 Analogue and 2 Digital Inputs 2 Analogue and 2 Digital Outputs Low Cost I/O Can Support 16 Dual I/O per Controller 001065 WebXL G50 Interface Interface WebXL and Mitsubishi G50A Controller Provides full control and feedback Map G50A points on WebXL via XML WebXL Add On Applications Online Room Booking System Book Rooms up to 6 months in advance Use with WebXL to control only occupied rooms Totally Web Based Requires a PC with network connectivity LogXL Log any WebXL point Graph, view or download data Totally Web Based Requires a PC with network connectivity 001073 PowerXL 001067 001072 Log Electricity, Gas and Water meters Graph, view or download logged data Calculate KVA and Power Factor Requires a PC with network connectivity 001074 12

13 Web Alarm Web Alarm Solutions Web Alarm 16 Complete Web Based alarm Panel Up to 16 binary Points No software registration Uses browser to configure 006016 Web Alarm 88 Complete Web Based alarm Panel Up to 8 binary Points and 8 Analogue Points 0-10V No software registration Uses browser to configure 006088 13

14 Sphere Systems Pty Ltd (03) 9470 8844 www.spheresystems.com.au 14