DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS



Similar documents
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

How To Test For Contamination In Large Volume Water

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Overview. Purpose. Methods. Results

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

Innovative vs Traditional

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Electrospray Ion Trap Mass Spectrometry. Introduction

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

CORESTA RECOMMENDED METHOD N 72

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

ApplicationNOTE Introduction

AMD Analysis & Technology AG

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Oasis HLB Cartridges and 96-Well Plates

Appendix 5 Overview of requirements in English

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

How To Use An Acquity Qda Detector

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS

Dionex IonPac AS19-4µm

Ádám Tölgyesi Joerg Stroka. Report EUR EN

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

HPLC Basics, Equipment, and Troubleshooting

Protein Separation Technology

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Purification of reaction mixtures using flash chromatography.

Pesticide Analysis by Mass Spectrometry

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

DETERMINATION OF PERFLUOROCHEMICALS IN RIVER WATER AND OTHER MATRICES BY AN AUTOMATED ON-LINE SPE UHPLC-MS/MS METHOD

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Vitamin C quantification using reversed-phase ion-pairing HPLC

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

Chemical analysis service, Turner s Green Technology Group

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

S olid Ph ase Extraction (SP E) Method:

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Introduction. Methods. Sample Processing

Waters Core Chromatography Training (2 Days)

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Supplementary Materials and Methods (Metabolomics analysis)

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Gas Chromatography Liner Selection Guide

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Transcription:

DEVELOPMENT O PCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1, Takeshi Nakano 2 1 Nihon Waters K.K,.1-3-12 Kitashinagawa, Shinagawa-ku Tokyo-to 140-0001 Japan. E-mail: tatsuya_ezaki@waters.com 2 Hyogo Prefectural Institute of Environmental Sciences, 3-1-27, Yukihira-cho, Suma-ku, Kobe-city Hyogo-ken, 654-0037 Japan. Abstract Liquid chromatography/tandem MS/MS system is used to analyze Per fluorinated compounds (PCs) without derivatization, quantifying trace levels of PCs in samples unambiguously is challenging because of the widespread back ground PCs contamination. Since PCs are present in many conpornents of lab instruments, trace levels of PCs can leach out. In addition, PCs are also detected in common HPLC solvents and in lab water. Because background PCs contamination is pervasive, quantifying trace levels of PCs requires special care. With online removal of PCs in mobile phase by solid phase extract ion (SPE) cartridge or technique applied retention gap, the contaminated PCs can been reduced or shifted off. Introduction Per fluorinated compounds (PCs) such as Perfluorooctanoic acid (POA) and Perfluorooctane sulfonate (POS) have been used for over 50 years in various applications that include surfactants, element in materials of chrome plating, fire fighting foam, photoresist on semiconductor manufacture and polymerization aid in synthesis polytetrafluoroethlene (PTE), and fluorpolymers 1. PCs are extremely stable and not prone to environmental degradation. Long-chain PCs such as POA and POS bioaccumulate in animals causing tumors and disturbing reproductive development 2. Trace levels of OH O PCs have been measured in groundwater, wastewater treatment plants, lake water, m O n O S OH the marine environment and even in the Arctic. In recent reports studies, POA, POS and other PCs have been detected at parts per billion levels in wildlife tissues and human serum. igure 1. Chemical structures of PCs : m=2, PBA; m=3, PPeA; m=4, PHxA; m=5,phpa; m=6, POA; m=7, PNA; m=8, PDA; m=9, PUdA; m=10, PDoA; m=11, PTrA; n=3, PBS; n=5, PHxS; n=7, POS; n=9, PDS. Vol. 71, 2009 / Organohalogen Compounds page 002660

Literature reports on the potential impact of PCs on human health and the environment indicate that this is a global concern. Consequently, there is an increased demand for rapid, sensitive and accurate analytical methods for the analysis of PCs in environmental and biological matrics. Materials and Methods SPE: OASIS HLB and SepPak AC2 used as SPE cartridges for on-line cleanup were obtained from Waters. The packing particle of OASIS HLB is reverse phase based hydrophilic-lipophilic balanced co-polymer structure and traps PCs of long chain length. SepPak AC2 is packed the particle of activated carbon and irreversibly traps PCs of short chain length. PCs Standard Solution: PC-MXA mixed Perfluorocarboxylic acid (PCAs), PS-MXA mixed Perfluoroalkyl sulfonate (PASs) and MPAC-MXA mixed surrogate ( 13 C labeled) of PCAs were all obtained from Wellington Laboratory Inc and were used as standard solution. All standard solutions were diluted with Methanol that was HPLC grade (Kanto Chemical Co.,Inc.).. Ammonium acetate and Acetonitrile (HPLC grade) were purchased from Kanto Chemical Co.,Inc. and used as mobile phase. LC MS/MS analysis: The LC apparatus was an Acquity Ultra Performance LC(Waters). All analytes were separated using a Waters Acquity UPLC BEH C18 column (50mm 2.1mm, 1.7um particle size) and Acquity UPLC BEH Shield RP18 column (100mm 2.1mm, 1.7um particle size). On the case of on-line cleanup of PCs in mobile phase and method applied retention gap technique, analytical condition of UPLC/MS/MS is shown in Table 1. Mass spectrometry was performed using a Waters TQ detector operated with an ESI interface in negative ionization mode. The capillary voltage was set at 0.5-2.0 kv. The flow rates of desolvation gas and cone gas were set to 1000 and 20-50 L/h, respectively. The source temperature and desolvation gas temperature were held at 120 and 400 C, respectively. Quantitative analysis was performed in multiselected reaction monitoring (MRM), and the one or two most abundant MRM transitions were listed in Table 2. Results and Discussion Method with on-line cleanup Three SPE cartridges (reverse-phase, activated carbon and reverse-phase) were installed on the line of Mobile Phase A (ig.2). PBA, PPeA and PHxA in mobile phase A were irreversibly trapped on these cartridges and baseline can been shown low and stable noise level, additionally, the peaks of PCs contaminated from LC system and mobile phase A can been disappeared (ig 3). When SPE cartridge columns capacity were overloaded with contaminated PCs, their peaks were appeared (ig.4). Vol. 71, 2009 / Organohalogen Compounds page 002661

Table 1 Analytical conditions of UPLC/MS/MS Table 1-1. UPLC/MS/MS method with on-line cleanup UPLC Conditions Column: UPLC BEH Shield RP18 2.1mmx100mm 1.7um Mobile Phase A: water containing 2mM Ammonium Acetate Mobile Phase B: Acetonitrile/ water in 2mM Ammonium Acetate (95/5) Gradient table and low Rate low rate (ml/min) (min) Conc. of A ( ) Conc. of B ( ) Gradient curve 0.4 Initail 60.0 40.0 6 0.4 4.0 5.0 95.0 6 0.4 5.0 60.0 40.0 11 Table 1-2. UPLC/MS/MS method with retention gap UPLC Conditions Column: ACQUITY UPLC BEH C18 2.1mmx50mm 1.7um Retention gap: ACQUITY UPLC BEH C18 2.1mmx100mm 1.7um Mobile Phase A: water containing 10mM Ammonium Acetate Mobile Phase B: Acetonitrile Gradient table and low Rate low rate (ml/min) (min) Conc. of A ( ) Conc. of B ( ) Gradient curve 0.3 Initail 99.0 1.0 6 0.3 8.0 5.0 95.0 6 0.3 9.0 99.0 1.0 11 Mobile Phase A Reverse Phase: OASIS HLB Trap of long chain length PCs Activated Carbon: SepPak AC2 Trap of short chain length PCs Reverse Phase: OASIS HLB ilter for activate carbon UPLC Pump / mixer Injector / Analytical column ig.2 : Three SPE cartridges were installed on the line of Mobile Phase A Vol. 71, 2009 / Organohalogen Compounds page 002662

Table 2 Multi-selected reaction monitoring (MRM) transitions of PCs Table 2-1. MRM transitions of PCAs Table 2-2. MRM transitions of PASs PC MRM CV (V) CE PC MRM CV (V) CE PBA 213.00 > 168.90 20 10 MPBA 217.00 > 171.90 20 10 PPeA 263.00 > 219.00 20 10 PBS 299.00 > 79.80 45 30 299.00 > 98.80 45 35 PHxS 399.00 > 79.80 50 40 PHxA MPHxA PHpA POA MPOA PNA MPNA PDA MPDA PUdA MPUdA PDoA MPDoA PTrDA PTeDA 313.00 > 118.90 20 15 313.00 > 268.70 20 10 315.00 > 118.90 20 15 315.00 > 269.70 20 10 363.00 > 168.70 20 20 363.00 > 318.70 20 10 413.00 > 168.70 20 20 413.00 > 368.70 20 15 417.00 > 168.90 20 20 417.00 > 371.70 20 15 463.00 > 218.90 20 15 463.00 > 418.70 20 10 468.00 > 218.90 20 15 468.00 > 422.70 20 10 513.00 > 218.90 20 20 513.00 > 468.70 20 10 515.00 > 218.90 20 20 515.00 > 469.70 20 10 563.00 > 268.90 25 20 563.00 > 518.70 25 15 565.00 > 268.90 25 20 565.00 > 519.70 25 15 613.00 > 268.90 20 25 613.00 > 568.90 20 10 615.00 > 269.00 20 25 615.00 > 569.90 20 10 663.00 > 318.90 25 25 663.00 > 619.10 25 10 713.00 > 318.90 25 20 713.00 > 669.10 25 10 399.00 > 98.80 50 45 MPHxS 403.00 > 83.80 50 40 POS 499.00 > 79.80 55 40 499.00 > 98.80 55 45 MPOS 503.00 > 79.80 55 40 503.00 > 98.80 55 45 PDS 599.00 > 79.80 65 55 599.00 > 98.80 65 60 Vol. 71, 2009 / Organohalogen Compounds page 002663

ig.5 : Method applied retention gap technique PCs contaminated in mobile phase A are trapped with retention gap column installed before injector. Each contaminated PCs elute on delay time for PCs in sample Vol. 71, 2009 / Organohalogen Compounds page 002664

20070824_05 1: MRM of 6 Channels ES- 0.23 313 > 268.9 0.01 0.27 0.62 0.70 117 0.10 0.47 0.30 0.94 0.77 0.88 1.09 1.20 1.28 20070824_01 1: MRM of 6 Channels ES- 0.99 313 > 268.9 273 0.13 0.19 0.59 0.31 0.42 0.710.76 0.83 1.00 1.12 1.17 1.28 21 20070824_05 1: MRM of 6 Channels ES- 1.02 263 > 218.9 0.10 1.10 122 0.51 0.65 0.71 0.92 0.16 0.81 1.19 0.29 0.36 0.58 1.28 20 20070824_05 1: MRM of 6 Channels ES- 0.52 213 > 168.9 444 7 20070824_01 1: MRM of 6 Channels ES- 0.83 263 > 218.9 1.12e3 0.02 0.17 0.23 0.42 0.58 0.76 0.89 1.09 1.17 2 20070824_01 1: MRM of 6 Channels ES- 0.72 213 > 168.9 2.42e3 0.01 0.18 0.32 0.44 0.54 0.60 0.83 0.99 1.06 1.22 1.26 0.13 0.38 0.22 0.44 0.49 0.69 0.82 1.06 1.17 1.28 8 4 ig.3: MRM chromatograms when Methanol were injected with SPE cartridges on the line of mobile phase A ig.4: MRM chromatograms when SPE overloaded with contaminated PCs Method applied retention gap technique PCs contaminated in mobile phase A are trapped with retention gap column installed before injector. At the same time of sample injection, gradient program is started. Accuracy on quantitative analysis of PCs can be improved with the time difference occurred between retention time of PCs in sample Test034 1: MRM of 6 Channels ES- 3.34 100 213 > 168.9 (PBA01) 2.81 8.03e3 3.67 3.76 0 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 ig. 6 MRM chromatograms of PBA with method applied retention gap technique and contaminated PCs because contaminated PCs are trapped on retention gap column (ig.5). ig. 6 shows MRM chromatograms of PBA and PBA in injected sample is detected as the peak that retention time is 2.81 minutes and the broad peak from 3.24 minutes is PBA contaminated from mobile phase A. Conclusion UPLC/MS/MS method with higher sensitivity and separation efficiency was established for analyzing 11 PCAs and 4 PASs and was higher accuracy on quantitative analysis because PCs in samples can be separated PCs contaminated from mobile phase with retention gap column. The method applied retention gap technique has issue that the pressure is higher on LC pump because retention gap and analytical column are installed, but has the stability on continuous injection and higher reliability when compare with the method of on-line clean up mobile phase. References 1. J W Washington, et al., J. Chromatogr. A, 1154, 111-120, 2007. 2. J M laherty, et al., J. Chromatogr. B, 819, 329-338, 2005. Vol. 71, 2009 / Organohalogen Compounds page 002665