This Tech Note describes modem connections using DAServers and provides some guidelines on how to make the modem connection work.



Similar documents
Communication to End Device Going In and Out of Slow Poll Mode

This tech note will explain how to use the following parameters in Configurator General Parameters.

Tech Note 743 Configuring Reporting Services 2008 Configuration for a New Host Name in Windows 2008 R2

Introduction. Application Versions. Installing Virtual SMTP Server. Tech Note 692 Using Virtual SMTP Server for SCADAlarm Notifications

Tech Note 1010 SQL Server Authentication and ArchestrA Network Account Restrictions When Installing Wonderware Historian

Tech Note 338 How to Change the ActiveFactory Reporting Website Default Install Location

Introduction. Application Versions. Compatibility and System Requirements. Firewall and DCOM Settings

Tech Note 847 Installing Wonderware Information Server (WIS) on the Windows Server Window 7 64 and 32-bit Operating System

Introduction. Notes. Important Considerations. Application Versions. Assumptions. 8/22/13 Setting Up Historian Servers for Tier-2 Summary Replication

1. Under Application Objects, open the $Tank object and then open the $TankDisplay as shown in Figure 1 (below).

Tech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products

8/23/13 Configuring SIDirect DAServer to Communicate with S7 PLC Over TCP Connection

Introduction. Configuration: Entity and OCO Modeling. Application Version: OCO General Configuration

Tech Note 868 Troubleshooting Wonderware Software Resource Issues with Performance Monitor

Introduction. Symbol Script Timeout Setting. Sample MES Custom Code in Symbol Script. Application Versions. Sample Code

Tech Note 400 Configuring Remote Connections for Windows 2000/2003/XP

Tech Note 751 Installing InBatch Report Contents for Wonderware Information Server (WIS)

Tech Note 912 Using Alternate TCP Port Numbers with Modbus Ethernet DAServer

Tech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products

Introduction. Tech Note 884 Setting Up Historian Servers for Tier-2 Summary Replication

All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.

Tech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler

Tech Note 663 HMI Reports: Creating Alarm Database (WWALMDB) Reports

Tech Note 920 Resolving Disabled ActiveFactory Reporting Website for Wonderware System Platform R2

Introduction. Issues. Symptoms. Application Versions. Case 1: Deploy an ArchestrA Object - UDO4DevUsers_001_001 - Has Error Messages

8/22/13 Configuring Windows SharePoint Services for PEM v1.0 to Work with SuiteVoyager v2.6

Tech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler

Industrial Application Server Redundancy: Troubleshooting Guidelines

All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.

Part I: Setting up Bristol Babcock's OPC Server

Instead, use the following steps to update system metadata that is stored in sys.servers and reported by the system function

This Tech Note provides step-by-step procedures to install Microsoft SQL Server 2012 on a 32- or 64-bit Operating System.

All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.

Enabling Cross-Machine Distributed Transactions (via MSDTC)

Using Network Application Development (NAD) with InTouch

How To Write A Summary On A Historyorian Server

Introduction. Application Versions. Assumptions. Delete $$ExportTempFolders. Tech Note 930 Wonderware System Platform Clean-up Guide

8/22/13 Configuring the SST5136SD PCI Card Using the New SSTDHP IO Server V8.1 or the DASDHPlus Server

All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.

Note: Not all messages in the log are indicative of a problem. Contact Technical Support if questions arise.

Migrating QI 8.0 Admin and Process Databases from Microsoft Access to Microsoft SQL Server

Tech Note 957 Creating Custom Password Entry on Intermec-Supported Handhelds

Note: This Tech Note was formerly titled Installing Microsoft SQL Server 2008 for Wonderware Historian v10.0.

Tech Note 813 Troubleshooting Wonderware Information Server (WIS) Part Four: Client License Release

Introduction. Back Up the Runtime Database. Application Versions

Security Settings for Wonderware Products

How To Migrate Qi Analyst To A New Database On A Microsoft Access (Windows) From A New Version Of Qi.Io To A Newer Version Of A New Qi 8.0 (Windows 7.3

Tech Note 612 Upgrading DLL Version Mismatches Between CBM Solution and System Platform

Tech Note 905 Troubleshooting Wonderware Information Server (WIS) Part Six: ArchestrA Graphics No Live-Data

This Tech Note describes working with Microsoft Reporting Services in order to publish InBatch Reports to Wonderware Information Server.

Tech Note 1035 Moving the Historian Runtime Database to Another Machine Using SQL Server 2012

Tech Note 551 Configuring SQLMail or Database Mail for the Historian Event

8/23/13 Configuring the Wonderware SECS-II/GEM Host Creator (SERIAL-RS232)

Wonderware Finland solutions for alarm management in power industry

Tech Note 1042 Solving Historian Memory Issue with SQL Server MemToLeave Configuration

To allow SQL Server Agent to trigger when a report is executed, we need to provide a set of report group types.

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents

This Tech Note provides detailed guidelines and options for defragmenting and maintaining your production databases.

Tech Note 652 Changing an ArchestrA Symbol's Custom Property Expression or Reference in Runtime

Tech Note 53 Configuring the Siemens SINEC H1 CP1413 for Windows NT

8/23/13 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Component 4: Introduction to Information and Computer Science

Network Management System (NMS) FAQ

CCT vs. CCENT Skill Set Comparison

White Paper. Next Generation Historians. Improve historical data access and analysis while reducing costs. What s Inside:

Installing the TCP/IP Network Protocol

Remote PC Guide for Standalone PC Implementation

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

TELUS Business Connect Customer Onboarding Guide. How to successfully set up your service

Multi-Homing Dual WAN Firewall Router

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Chapter 15: Advanced Networks

8/23/13 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet)

Computer Networking. Definitions. Introduction

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

Andover Continuum Remote Communication Configuration Guide

Network Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS

Wonderware Historian Client Installation Guide. Invensys Systems, Inc.

Chapter 1 Connecting the Router to the Internet

801.11n Wireless Broadband Router

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

Configuring Check Point VPN-1/FireWall-1 and SecuRemote Client with Avaya IP Softphone via NAT - Issue 1.0

9 Simple steps to secure your Wi-Fi Network.

7TMITETH. IGSS Mitsubishi FX/Q TCP/IP Interface Driver User Manual. Schneider Electric Denmark A/S

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

802.11n Wireless Broadband Router WNRT-625

11.1. Performance Monitoring

Digi Cellular Application Guide Using Digi Surelink

4G Business Continuity Solution. 4G WiFi M2M Router NTC-140W

Users Manual. Super Silent Client. Super Silent Client Users Manual Piravi Software Solutions. Document Revision 1.

ProCurve Networking. Troubleshooting WLAN Connectivity. Technical White paper

Network Installation Guide. WorkForce 610 Series Artisan 710 Series

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Self Help Guide IMPORTANT! F5D Setting Up An Ad Hoc Connection. Please read the following carefully;

The Benefits of Component Object- Based SCADA and Supervisory System Application Development

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Transcription:

Tech Note 949 Managing Wonderware DAServers and Modem Connections All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#: 002769 Created: March 2014 Introduction More and more customers are introducing various modems (data, radio, wire or wireless modems) in to their SCADA networks in the recent years due to the availability of new technology and the need to expand their control network coverage farther, to even more remote areas and to greater distances. This Tech Note describes modem connections using DAServers and provides some guidelines on how to make the modem connection work. IMPORTANT: This Tech Note should be used as a guideline and at your own risk. Modem connections using Wondeware DAServers are not supported. Wonderware DAServers (DASABCIP, DASABTCP, DASMBTCP, DASGESRTP, DASS7, DASSiDirect) have not been tested to support modem communication. However, DAServer-to-modem communications can work in most cases. Because most DAServers are not tested, Wonderware Support might not have sufficient information to determine the cause of a problem in this context. However, most of the time the DAServers will work perfectly with a wide range of modems. Application Versions N/A Details For the details on how to configure any hardware modem, please refer to the manufacturer's recommendations. As seen in Figure 1 (below), there are no modem objects available in Wonderware DAServers' Configuration Editor.

FiGurE 1: No MoDEm OBJECtS AVaiLaBLE for OtHEr DASErVErS Recommendations for DAServer Modem Connections For DAServers (most commonly the TCP type of DAServers), the secret of success is making sure that the modem connection is "transparent" to the DAServer. In general, the modem device is connected to the field/end devices. The configuration is done independently of the DAServer configuration using the modem manufacturer's recommended procedures. Once the configuration is done, the modem becomes the "proxy" for the field device that the DAServer will be communicating with.

FiGurE 2: LoGiCaL ArCHitECturE for MoDEm CommuniCation So in most cases, good communication between the DAServer and the field device depends on successful modem device configuration. Monitoring the Communication Wonderware DAServers usually use the $sys$status tag as communication monitors. This is a built-in communication monitoring system tag that exists in all DAServers. Some customers monitor the modem connection by setting up a heartbeat signal in the PLC, such as a toggle bit or a running clock register of some kind. Then you can use a graphic diaplay, or write a simple logic in the client application (InTouch or IAS) to read and display the heartbeat signal. If that value does not change in a preset time range (10, 15, 30 seconds) you can trigger the communication failure alarm. Common Remote Modem Connection Issues Physical Distance Most commonly, the modem connection covers great distances. The communication speeds in this setup are subject to the network conditions, load, interference, quality and availability of an intermediate station (such as a sattelite or booster) and the field device(s).

In Wonderware's experience, in order to secure the quality of the communication, the update interval setting in the DASerer configuration needs to be longer than the direct connection type configuration. The longest update interval that we have seen can go beyond minutes, where the wireless connection is made to field devices in rotations. Network and Traffic Physical network connections are very important to remote connection quality. When using modem connections, the more robust the network connection (cables, connectors, etc), the better communication quality you will receive. Wonderware highly recommends that you separate the corporate network from the Control network by using separate NIC interface cards with different IP address segments. This will avoid heavy traffic from data flows in the control network. Troubleshooting Tips Ping Pinging is a most common troubeshoot tool when you are not getting data updates from the modem and end devices. In the TCP network, you should ping both the modem and the end device successfully. TCP Port Depending on which DASever and which protocol is in the subject of discussion, the TCP port number must be open to communicate in both directions (read and write). Some intelligent modem devices come with a hardware or software firewall (switches and routers). You need to make sure the proper TCP port number(s) are opened in both directions. The following list of port numbers are used by our major DAServers: DASABCIP: 44818 DASABTCP: 2222 DASMBTCP: 502 DASGESRTP: 18245 DASSiDirect: 102 Send and Receive Flags In many cases, by turning on the DAServer log viewer flags DASsend, DASreceive, and DASverbose, you can catch logviewer protocol communication information. You can then use the data for troubleshooting purposes. In certain cases, Wonderware Technical support may ask for the send/receive information for analysis. The log flags are found in the SMC/Logviewer/Action/Log Flags (Figure 4 below).

FiGurE 3: LoG FLaGS 1. From the left panel, select the DAServer of interest. 2. In the upper-right panel, find the DASSend, DASReceive, and DASVerbose flags and check them. 3. On the main menu click File/Apply to activate the flags. 4. Make sure you turn these flags off after few minutes, so the log viewer is not cluttered with excessive entries. FiGurE 4: FLaG LoG ItEmS A. Chaque Tech Notes are published occasionally by Wonderware Technical Support. Publisher: Invensys Systems, Inc., 26561 Rancho Parkway South, Lake Forest, CA 92630. There is also technical information on our software products at Wonderware Technical Support. Back to top 2014 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or utilized in any form or by any means, electronic or

mechanical, including photocopying, recording, broadcasting, or by anyinformation storage and retrieval system, without permission in writing from Invensys Systems, Inc. Terms of Use.