VALIANT COMMUNICATIONS



Similar documents
ORION TELECOM NETWORKS INC. T1

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

VALIANT COMMUNICATIONS LIMITED

VALIANT COMMUNICATIONS LIMITED

ORION TELECOM NETWORKS INC.

E1-GSM RION ORION TELECOM NETWORKS INC. E1 Channel Bank with 30 X GSM Wireless Interface(s) TELECOM NETWORKS

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Rack mounted telephone- and leased line modem for industrial applications

Chassis, Power Supply, and Element Management

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

3500/22M Transient Data Interface

TrueAlarm Fire Alarm Systems

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Uninterruptible Power Supply

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Loop-IP6700 TDMoEthernet

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Waveguide Access Point WGA631. Product Guide

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

TDMoEthernet. Description

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Foxboro Evo Process Automation System

DCS Data and communication server

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-IP6510 Multiple WAN Router/Bridge

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Gigabit Switching Ethernet Media Converters - Product User Guide

Indoor / Outdoor Antenna

VALIANT COMMUNICATIONS LIMITED

Loop-IP6702 TDMoEthernet

8-Port PoE Network Switch

Communicate and view data from meters with one simple device

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Cisco 7816-I5 Media Convergence Server

UPS Network Interface. Quick InstallationGuide

Infinity C DC to DC Power System

G-TAP A Series // Data Sheet

High Power Programmable DC Power Supplies PVS Series

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

BridgeWay Fixed Base Radio Telecom VoIP Gateway

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Loop-IP6700 TDMoEthernet

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

Telephone- and leased line modem for industrial applications TD-36

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BRIDGEWAY MOBILE VOIP RADIO-INTERCOM GATEWAY

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Temperature & Humidity SMS Alert Controller

T200, PTP/IEEE 1588 Grandmaster Clock and

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

HWg-STE HWg-STE PoE MANUAL

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

HDO700 P FIBRE OPTIC TRANSMITTER

Product Specifications

User Manual. EtherUSB

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Long Range Ethernet Extender

Job Aid Pre-Installation Information S8500 Media Server

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Network Management Card. User Manual

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

ProCurve Switch 2500 Series

Gigabit Desktop. manual Models & Model shown: INT / UM

Fax Server. Blue Line IP ISDN ISDN PRI

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Digital input modules

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web Management. User s Manual For SNMP Web Card/Box

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

TC3848. Applications. A JumboSwitch Technology

ProCurve Switch 1700 Series

1701/22 FieldMonitor Management Interface Module

Smart-UPS On-Line 230 V

3500/25 Enhanced Keyphasor*Module

How To Run An Nport I5000A Device Server

DVT913 TV CHANNEL CONVERTER

Cisco Redundant Power System 2300

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Current Monitoring Kit

MDI/MDIX) FEP-32008T-3

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Industrial Ethernet Switches

ProCurve Switch 8000m (J4110A) and Switch 8000m

SFP Copper Transceiver 10/100/1000Base-T

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Transcription:

VALIANT COMMUNICATIONS VCL-XC 64 Port Electronic Intelligent Patch Panel E1 to E1 Patch Panel Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN, United Kingdom Valcomm Technologies Inc. 4000 Ponce de Leon, Suite 470 Coral Gables, FL 33146 INDIA Valiant Communications Limited 71/1, Shivaji Marg, New Delhi - 110015, India

Product Description The VCL-XC, 64 E1 Electronic Patch Panel allows the user to cross-connect any E1 port to any E1 port, electronically through user executable software commands, without having to use any patch-cords or loosely hanging inter-connect cables. VCL-XC, 64 E1 Electronic Patch Panel also provides the user with the capability to unidirectionally broadcast a E1 input to multiple E1 destinations. The patch-panel may be accessed remotely over a TCP/IP link using Telnet. This allows the user to create / patch new circuits remotely and make new E1 cross-connections on the fly. SNMP V2 Traps are also generated over a UDP link, which allows the user to monitor the patch-panel and all E1 circuits remotely for any alarms. An MIB file is provided with the patch-panel to allow easy integration with customer's network management systems (NMS), or for easy integration with standard SNMP browsers. Where it should be used, who should use it and in which applications: VCL-XC, 64 E1 Electronic Patch Panel is designed to be used in Central Offices, Data Centers, Command and Control Centers, Remote Cell Sites, Utilities and Dealing Rooms seeking to eliminate the jungle of external patch-cords and loosely hanging wires which usually exists in locations where E1 patch-panels are installed. Why it should be used: VCL-XC, 64 E1 Electronic Patch Panel eliminates the use of patch cords and the maze of loosely hanging inter-connect wires. Easier Management - VCL-XC, 64 E1 Electronic Patch Panel allows easier management of the E1 crossconnects since all cross-connects can be made and managed from a central location over TCP/IP or UDP Network using either CLI (text) commands, or a GUI. Efficient Management - VCL-XC, 64 E1 Electronic Patch Panel allows a more efficient management since a log / database of all circuit patches / cross-connects can be saved and archived as a MS (Microsoft) Access database file and retrieved and re-loaded whenever required. VCL-XC, 64 E1 Electronic Patch Panel eliminates the need for labeling the patch-cords and inter-connected wires since all inter-connection records are automatically retained in the system's non-volatile memory. Additionally, the same can also be saved and archived as a MS (Microsoft) Access database file from the system's GUI. VCL-XC, 64 E1 Electronic Patch Panel can easily be integrated into any standard existing customer's NMS. An MIB file is provided with the equipment for easy integration. 2

An Intelligent Patch Panel: VCL-XC, 64 Port E1 Electronic Patch Panel keeps the user informed of potential problems by generating SNMP V2 alarms. VCL-XC, 64 Port E1 Electronic Patch Panel generates SNMP V2 alarms and is supplied with an MIB file which allows the user to easily integrate the VCL-XC, 64 Port E1 Electronic Patch Panel into their NMS (Network Management Software) for faster trouble-shooting and fault rectification. This results in more efficient network control and fault management. VCL-XC, 64 Port E1 Electronic Patch Panel also maintains a log of the 200 most recent time-stamped events, as they occur in real-time, by storing them in the system memory. These events may be viewed at any time by a user. The system event log is maintained in addition to SNMP V2 traps, which the equipment sends out to a centralized NMS, when such events or alarms occur. User friendly the equipment may be assessed remotely using Telnet, GUI (Graphical User Interface) or SNMP over an Ethernet link through the system's 10/100BaseT Ethernet Port. The equipment may be also accessed locally through either an RS232 (DB9) serial or a USB COM Port. Highlights: 64 circuit, E1 to E1 electronic, remotely manageable patch panel Allows the user to cross-connect between any E1 port to any E1 port, or any E1 port to Multiple E1 Ports (in a broadcast mode only), electronically Eliminates the use of the messy, loose, hanging inter-connect wires Host of alarms for trouble shooting and maintenance SNMP - V2 Traps / Alarms Telnet and GUI based remote management features Dual power inputs (1+1) to connect the equipment to two separate - 48V DC power sources for power source redundancy Compact. Available in 19-inch, 2U shelf (DB37 connector) version, and a 19-inch, 3U shelf (RJ45 connector) version. Indications and Alarm Monitoring Loss of incoming signal at any E1 Port Configuration error alarm 64 LED indicators to indicate the status of each E1 link System's internal 3 Volts power supply present External -48V DC input present System Self Test Error. Programmable Features Enabling or disabling E1 channels (masking alarms) of the E1 channels that are un-connected and not in use Creating a cross connect between E1s using the Windows based, easy to use GUI Telnet interface for remote programming by using text commands 3

Status Monitoring: Status of alarms Enabled / Disabled status of E1 ports Monitoring of the VCL-XC, 64 Port E1 Electronic Patch Panel status and configuration SNMP - V2 Traps / Alarms. Dual Power Inputs: The system provides dual -48V DC power inputs for connecting the equipment to two separate -48V DC power sources for added security and power backup. Rear View Option 1 - with 3U high, rack-mountable RJ-45 (F) 19-inch shelf #22 #21#20 #19 #18 #17#16 #15 #14 #13#12 #11 #10 #9 #8 #7 #6 #5 #4 #3 #2 #1 P22 P21 P20 P19 P18 P17 P16 P15 P14 P13 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 #44 #43 #42 #41 #40 #39 #38 #37 #36 #35#34 #33 #32 #31 #30 #29 #28 #27 #26 #25 #24 #23 EO2 P70 P44 P43 P42 P41 P40 P39 P38 P37 P36 P35 P34 P33 P32 P31 P30 P29 P28 P27 P26 P25 P24 P23 EC2 #64 #63 #62 #61 #60 #59 #58 #57 #56 #55 #54 #53 #52 #51 #50 #49 #48 #47 #46 #45 EO1 P69 EC1 P64 P63 P62 P61 P60 P59 P58 P57 P56 P55 P54 P53 P52 P51 P50 P49 P48 P47 P46 P45 P66 EARTH R1 ALARM NO COM NC P65 Option 2 - Rear View - with 2U high, rack-mountable DB-37 (F) 19-inch shelf 57-64 P8 49-56 P7 41-48 P6 33-40 P5 EO2 EC2 P14 EO1 EC1 P13 25-32 P4 17-24 P3 9-16 P2 1-8 P1 P12 EARTH NO COM NC P11 ALARM 4

Technical Specifications E1 Interface Maximum Number of Interfaces 64 E1 Interfaces Conformity (Electrical) ITU-T G.703 Framing Transparent (PCM30 and PCM31) Bit Rate 2048 Kbps ± 50 ppm Line Code HDB3 Nominal Impedance 120 Ohms balanced Peak Voltage of a mark 3.0 V ± 0.3 V For 120 Balanced interface Peak Voltage of a space 0 V ± 0.3 V For 120 Balanced interface Nominal Pulse Width 244 ns Pulse Mask As per ITU (CCITT) Rec. G.703 Output Jitter <0.05 UI (in the frequency range of 20Hz to 100 Khz) Permissible Attenuation 6 db at 1 Mhz Return Loss at: 51.2 KHz to 102.4 KHz > 12dB 102.4 KHz to 2048 KHz > 18dB 2048 KHz to 3072 KHz > 14dB Jitter Tolerance As per ITU (CCITT) G.823 Connectors 64 x RJ-45 (F) connectors - 19 Inch 3U shelf version Connectors 64 Port, 8 x DB37 (F) connectors - 19 Inch 2U shelf version System Management and Access Windows XP and Windows 7 compatible Graphical User Interface (GUI) Telnet - CLI (Command Line Interface) SNMP V2 (MIB File provided with the equipment). Management and Control Port Serial Management Port (RS232) - COM Port USB Serial Port 10/100BaseT for remote management over a LAN / TCP/IP network. Command Language Command Line Interface (english text commands) 5

Management Network interface Compatibility Protocols supported LEDs Management EMI Compliance RJ-45 Ethernet 10BaseT or 100BaseTx (auto sensing),mdi-x. Ethernet Version 2.0 IEEE802.3 ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP 10Base-T and 100Base-TX Activity, Full/half duplex. SNMP, Serial login, Telnet login Radiated and conducted emissions complies with Class B limits of EN55022:1998 Direct and Indirect ESD complies with EN55024:1998 RF Electromagnetic Field Immunity complies with EN55024:1998 Electrical Fast Transient/Burst Immunity complies with EN55024:1998 Power Frequency Magnetic Field Immunity complies with EN55024:1998 RF Common Mode Conducted Susceptibility complies with EN55024:1998 Power Supply Specifications Input DC Voltage -48V DC (nominal) Range of Input Voltage -18V DC to -72V DC Input Voltage Reversal Protection Protected Over Current Protection 3 Amperes Short Circuit Protection Current limit up to 3 Amperes recovers on removal of short circuit Efficiency at Full Load >93% Ripple at Full Load <5mVrms Spike at Full Load <50mV Power Supply Power supply Power supply Power consumption -48V DC (-18V DC to -72V DC) Redundant (1+1 Protected) Inputs 14 watts (maximum) Environmental Temperature and Humidity Altitude 0 C to + 50 C, 90% R.H. (Non-condensing) Upto 9,000 feet Compliance FCC Part 68, Class B CE Chassis Option 1-3U high, rack-mountable RJ-45 (F) 19-inch shelf Option 2-2U high, rack-mountable DB-37 (F) 19-inch shelf 6

Dimensions Particulars 3U high, rack-mountable 2U high, rack-mountable RJ-45 (F) 19-inch shelf DB-37 (F) 19-inch shelf Depth 292 mm 260 mm Width 485 mm 485 mm Height 3U (133.33 mm) 2U (90 mm) Ordering Information S.No. Part No. Product Description 1. VCL-XC-1466_1467- ELE-E1-120-RJ45F-64 2. VCL-XC-1466_1468- ELE-E1-120-DB37F-64 3. VCL-1514_1513-CON- 120-DB37F-75-BNCF-16 VCL-XC 64 E1 Electronic Patch Panel VCL-XC, 64 Port [64xRJ45F] Electronic Intelligent Patch Panel (E1 to E1) 19" Shelf 3U High Rack Mount Version Supports : - 64 x E1 interface [120 Ohms, 64 x RJ45 (F) Connectors] - 2 x -48V DC Power Supply Input - 1 x System Core Cables, Installation Accessories, Documentation, System User Manual / Disk etc - OAM : [SNMP, Telnet (RJ45 Port) and Serial Port (USB and DB-9 COM port) VCL-XC 64 E1 Electronic Patch Panel VCL-XC, 64 Port [08xDB37F] Electronic Intelligent Patch Panel (E1 to E1) 19" Shelf 2U High Rack Mount Version Supports : - 64 x E1 interface [120 Ohms, 8 x DB37 (F) Connectors] - 2 x -48V DC Input Power Supply - 1 x System Core Cables, Installation Accessories, Documentation, System User Manual / Disk etc - OAM : [SNMP, Telnet (RJ45 Port) and Serial Port (USB and DB-9 COM port) 16 x E1, 120? [2xDB37F] to 75? [32xBNCF] Converter Panel 19" Metal case 1U High Rack Mount Version [Includes : DB37M-DB37M Cables] [BNC cables not included] Technical specification s are subject to change s without notice. Revision 12 - March 10, 2015. U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN, United Kingdom Valcomm Technologies Inc. 4000 Ponce de Leon, Suite 470 Coral Gables, FL 33146 INDIA Valiant Communications Limited 71/1, Shivaji Marg, New Delhi - 110015, India 7