WEB log. Device connection plans



Similar documents
WEB log. Device connection plans

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

NC-12 Modbus Application

Application/Connection Examples

Technical Information POWER PLANT CONTROLLER

WEATHER STATION FOR SOLAR FARM MONITORING

User Manual Revision English

PCS0100en Persy Control Services B.V. Netherlands

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Table of Contents. Creating a VC1000 Network... 3

Model 201 Wiegand Touchpad Reader Installation Guide

INTMOD485-LH Protocol Converter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Paragon Explorer Lite Communication Software

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Modular I/O System Analog and Digital Interface Modules

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Installation Guide Solar Connect-11

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

User Manual Weather station V 0.2

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Documentation. M-Bus 130-mbx

Power Supply and Cabling Options. SmartTrak 100/101/140

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

RS485 & RS422 Basics

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

SYSTEM 4C. C R H Electronics Design

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Monitoring solar PV output

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

User Manual Revision English

RC2200DK Demonstration Kit User Manual

EDI Distributor Control Interface Wiring and Setup Instructions

R60 USB to CAN interface Manual (1.5 EN)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

1 Serial RS232 to Ethernet Adapter Installation Guide

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

User Manual Revision English

User Manual Revision English

LMU Hardware and Installation Guide

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TX OPEN RS232/485 module

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Quick Connect. quick - simple - efficient.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

EZ-View Network Communications Guide

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

User Manual Revision English

TDAS G5-DB Hardware User s Manual

Communication Setup Application Note

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

System Wiring Design Guide

Digital input modules

UniPi technical documentation REV 1.1

USER MANUAL V5.0 ST100

Color Mark Sensor with Red or Green LED E3S-VS

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Temp. & humidity Transmitter Instructions

User Manual Revision English

RS - SPM. Serial parallel translator module

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Operating instructions Capacitive sensors

USB Rover port USB m Cat 5 Extender. User Guide

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Manual Serial PCI Cards

Advanced Data Capture and Control Systems

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

TMS TANK MANAGEMENT SYSTEM

T0118 T2118 T3118. Instruction Manual

Modbus and ION Technology

BACnet Automation Interface Module (Network Version)

Temperature & Humidity SMS Alert Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Transcription:

WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425*

Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited, duplicated or distributed using electronic systems, without written permission. Compensation shall be payable in the event of any copyright infringements. All brand names mentioned in this manual are the property of their respective manufacturers and are hereby acknowledged. Details regarding the manual The original document is written in German. All other language versions are translations of the original document and are hereby identified as such. All information in this operating manual has been compiled and checked with the greatest care and diligence. Nevertheless, the possibility of errors cannot be entirely excluded. The manufacturer therefore cannot accept any liability for errors or their consequences. Subject to technical alterations. *Current version The latest version of this document "Device connection plans" can be found on the manufacturer's website.

Contents 1. Notes on this operating manual... 2 2. Safety instructions for operation... 2 2.1 Intended use... 2 2.2 Personnel... 2 3. Overview of interfaces... 3 4. Cabling... 4 4.1 RS485 and RS232/422... 4 5. Sensors... 8 5.1 Irradiance sensors... 8 5.2 Pyranometer... 16 5.3 Temperature sensors... 22 5.4 Hygro-thermal sensors... 26 5.5 Wind speed sensors... 28 5.6 Wind direction sensors... 30 5.7 Weather stations... 32 6. Power quality analyzers... 34 6.1 Janitza power quality analyzers... 34 7. Energy meter... 36 7.1 Three-phase energy meter... 36 8. String measuring technology... 40 8.1 meteocontrol string measuring technology... 40 1 48

1. Notes on this operating manual This manual is a key aid when it comes to ensuring proper operation of the device. It contains important information and safety notes to help you use the devices correctly, economically and in the intended manner. The manual helps to avoid dangers, to reduce repair costs and downtimes, and to increase the reliability and operating life of the devices. During installation, all the manuals for system modules and components must be taken into account. 2. Safety instructions for operation 2.1 Intended use Only the permitted signals and signal strengths may be applied to the connections of the data loggers and modules used here. Installation is only permitted indoors. For installation outdoors or in a dusty environment, the device must be installed in a standardized protective enclosure. 2.2 Personnel Installation, commissioning and maintenance of the device may only be performed by a qualified electrician. Given their specialist training, knowledge, experience and familiarity with the relevant standards and regulations, a qualified electrician is in a position not only to carry out work on electrical systems but also to recognize and avoid possible dangers unaided. The qualified electrician must comply with the occupational health and safety laws in force. Please note in particular: all national installation and set-up regulations (e.g. VDE in Germany), all generally accepted codes of practice, information on transport, installation, operation, service, maintenance and disposal given in the documentation for the devices used, specific values, limits and information relating to operating and ambient conditions on type plates and in data sheets. 2 48

3. Overview of interfaces Overview of interfaces (1) Analog inputs (DI1 DI4) (7) Ethernet (2) Reset button (8) RS485 (3) Digital inputs (DI1 DI4) (9) RS232/422 (4) Power supply (10) Digital output (DO1) (110 V 230 V AC) (5) RJ45 phone socket (PSTN) (11) Switch between RS232 / RS422 (6) Power supply (24 V DC) Can also be operated as RS485 for additional Modbus devices 3 48

4. Cabling 4.1 RS485 and RS232/422 The two RS485 and RS232/422 interfaces are used to query information recorded on various bus devices such as inverters, power quality analyzers, etc. The RS232/422 interface can also be used as an RS485 interface. In order to do this the interface has to be operated in RS422 mode (for this, please refer to the manual of your WEB log data logger). Which interface you should use to connect inverters and accessories depends on your specific driver. Please refer to the appropriate driver datasheet (http://www.meteocontrol.de/downloads/). Please note the following regarding the bus cabling: All devices on a bus must use the same protocol to communicate. The data logger functions exclusively as a master on the bus. The maximum permitted number of bus devices has to be observed (see driver datasheets). The order of the bus devices on the bus is unimportant. The use of a repeater is necessary for every 32nd bus device and for long cable runs. The bus should be cabled with a twisted and shielded pair of wires. The shield of the bus cable must be grounded at one end of the connection only. The data logger does not have its own grounding When you wire the bus wires, make sure that AC and DC cables are routed separately. Do not switch the buses signal wires. Different manufacturers interpret the RS485 interface s underlying standard differently. A and B wire labels may be different for different manufacturers. The + and indicators, on the other hand, are unambiguous. To prevent reflections, the bus must always be terminated with a parallel terminator. 4 48

Daisy chain If you want to connect more than one device to the bus, you must daisychain the connection. This means that different devices can only be queried jointly if they use the same communication protocol and the same serial communication parameters (baud rate, data bits, parity, stop bits). The first and last device on the bus must be terminated with a resistor. The data logger is provided with integrated terminating resistors that are permanently activated. Daisy chain cabling RS485/422 5 48

Star wiring Another possible way of operating multiple devices on the RS485 bus is called star wiring. In this wiring variant, a HUB 6 Port RS485 S (item number 421.641) is used to seperate the bus into a serveral bus strings. To connect the HUB 6 Port RS485 S to the WEB log, please use a Connect Universal RS cable (item number: 422.537). Various devices can only be queried together if they communicate with the same protocol and have identical serial communication parameters (baud rate, number of data bits, parity, stop bits). Each bus string can have a maximum length of 1200 m. All the devices on the same bus string are wired together in a daisy chain. The first and last device of each bus string must be terminated with a resistor. The HUB has integrated terminating resistors at each interface, which are permanently activated. In this wiring variant, the total number of bus devices may not exceed the maximum permissible number of bus devices. Star wiring for RS485 6 48

7 48

5. Sensors 5.1 Irradiance sensors SI-12-TC, SI-12-TC-T Item Product name Item number Particularity Irradiance sensor Si-12-TC 423.000 Connection cable: 3 m Irradiance sensor Si-12-TC 423.002 Connection cable: 30 m Irradiance sensor Si-12-TC 423.004 Connection cable: 15 m Irradiance sensor Si-12-TC 423.013 Connection cable: 60 m Irradiance sensor Si-12-TC-T 423.001 Connection cable: 3 m Irradiance sensor Si-12-TC-T 423.003 Connection cable: 30 m Irradiance sensor Si-12-TC-T 423.005 Connection cable: 15 m Connection Wire color Use Black Ground Red Power supply (12 24 V DC) Brown Temperature signal (0 10 V / 0 20 ma / 12.28 20 ma) Orange Irradiance signal (0 10 V) Configuration data SI-12-TC-T Sensor Measurement Input Unit Gradient Offset Irradiance Analog 0 10 V W/m 2 120 0 Temperature Analog 0 10 V C 10.869-20 In the case of the sensor SI-12-TC, the brown wire for temperature measurement is not used 8 48

Sensor connection 9 48

SI-12-TC-LC Connection Wire color Use Black Ground Red Power supply (12 24 V DC) Orange Irradiance signal (0 10 V) Configuration data Sensor Measurement Input Unit Gradient Offset SI-12-TC-T Irradiance Analog 0 10 V W/m 2 120 0 10 48

Sensor connection 11 48

SI-420-TC, SI-420-TC-T Item Product name Item number Particularity Irradiance sensor Si-420-TC 423.010 Connection cable: 3 m Irradiance sensor Si-420-TC-T 423.011 Connection cable: 3 m Irradiance sensor Si-420-TC-T 423.012 Connection cable: 15 m Connection Wire color Black Red Brown Orange Use Ground Power supply (12 24 V DC) Temperature signal (12.28 20 ma) Irradiance signal (4 20 ma) Configuration data Sensor Measurement Input Unit Gradient Offset Irradiance Analog 4 20 ma W/m 2 75-300 SI-420-TC-T Temperature Analog 12.28 20 ma C 12.5-173.5 In the case of the sensor SI-420-TC, the brown wire for temperature measurement is not used 12 48

Sensor connection 13 48

Si-RS485-TC-T (Modbus RTU), Si-RS485-TC-T V2 (Modbus RTU) Item Product name Item number Particularity Irradiance sensor Si-RS485-TC-T V2 423.016 Connection cable: 3 m Connection Wire color Use Black Ground Red Power supply (12 24 V DC) Brown RS485 Modbus interface A (+) Orange RS485 Modbus interface B (-) Set the bus address on the sensor (see sensor documentation). If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). 14 48

Sensor connection 15 48

5.2 Pyranometer Kipp & Zonen SMP10 / SMP11 (analog interface) Item Product name Item number Pyranometer SMP11 423.029 Connection Wire color Black White Brown Green Use Ground Power supply (5 30 V DC) Irradiance signal GND Irradiance signal (4 20 ma) Configuration data Measurement Input Unit Gradient Offset Irradiance on horizontal plane Analog 4 20 ma W/m 2 100-400 Irradiance on module plane Analog 4 20 ma W/m 2 100-400 The sensor outputs (power signal) must have a resistance of approx. 500 Ω for a correct measurement. Since the data logger has an internal load resistance of 70 Ω, we recommend you to install a commonly available 430 Ω load resistor on the sensor output. Pyranometers can be used to measure irradiance either on the horizontal plane or on the module plane. 16 48

Sensor connection 17 48

Kipp & Zonen SMP10 / SMP11 (Modbus RTU) Item Product name Item number Pyranometer SMP11 423.029 Connection Wire color Use Black Ground White Power supply (5 30 V DC) Gray RS485 Modbus interface B (-) Yellow RS485 Modbus interface A (+) Blue RS485 Modbus interface GND Set the bus address on the sensor (see sensor documentation). If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). Pyranometers can be used to measure irradiance either on the horizontal plane or on the module plane. 18 48

Sensor connection 19 48

Kipp & Zonen CMP11 with AMPBOX Item Product name Item number Pyranometer CMP11 423.024 AMPBOX 423.310 Connection Wire color White Green Use Power supply + 24 V DC Analog output 4 ma to 20 ma Configuration data Measurement Input Unit Gradient Offset Irradiance on horizontal plane Analog 4 20 ma W/m 2 100-400 Irradiance on module plane Analog 4 20 ma W/m 2 100-400 Pyranometers can be used to measure irradiance either on the horizontal plane or on the module plane. The input and output of the AMPBOX are galvanically isolated to prevent feedback and interference and to protect the data logger. The connecting cable between the AMPBOX and the pyranometer must not be lengthened or shortened. Because the AMPBOX and the pyranometer are calibrated together, both devices must always be installed together. 20 48

Sensor connection 21 48

5.3 Temperature sensors PT1000 Adhesive Sensor Item Product name Item number PT1000 adhesive sensor 423.211 Connection Wire color Brown White Use Ground PT1000 temperature signal Configuration data Measurement Input Unit Gradient Offset Temperature PT1000 C 1 0 22 48

Sensor connection 23 48

PT100 adhesive sensor with signal converter Item Product name Item number Particularity PT100 adhesive sensor 423.201 PT100 signal converter 24 V DC 423.301 Power supply: 24 V DC PT100 signal converter 230 V DC 423.302 Power supply: 230 V AC Connection Wire color Red White Use Ground Temperature signal PT100 Configuration data Measurement Input Unit Gradient Offset Temperature Analog 0 10 V C 15-50 The following signal converters are available for connecting the temperature sensor: - 423.301 PT100 Signal converter 24 V power supply - 423.302 PT100 Signal converter 230 V power supply 24 48

Sensor connection 25 48

5.4 Hygro-thermal sensors meteocontrol compact hygro-thermal sensor Item Product name Hygro- thermal sensor meteocontrol compact Item number 423.309 Connection Wire color Yellow Black Green Brown Use Power supply for humidity sensor (24 V DC) Power supply for temperature sensor (24 V DC) Temperature signal (4 20 ma) Ambient humidity signal (4 20 ma) Configuration data Measurement Input Unit Gradient Offset Temperature Analog 4 20 ma C 6.25-55 Relative humidity Analog 4 20 ma % r. h. 6.25-25 The sensor outputs (power signal) must have a resistance of approx. 500 Ω for a correct measurement. Since the data logger has an internal load resistance of 70 Ω, we recommend you to install commonly available 430 Ω load resistors on the sensor outputs. 26 48

Sensor connection 27 48

5.5 Wind speed sensors meteocontrol compact wind speed sensor (0 10 V) / (4 20 ma) Item Product name Item number Particularity Wind speed sensor meteocontrol 423.412 Output: 4 20 ma compact Wind speed sensor meteocontrol compact 423.430 Output: 0 10 V Connection Wire color Use Yellow Wind speed signal ground Green Wind speed signal (4 20 ma) Gray Power supply for heater (24 V AC or DC +) Pink Heater GND (24 V DC -) White Power supply for sensor (24 V AC or DC +) Brown Sensor GND (24 V AC or DC -) Configuration data Sensor Measurement Input Unit Gradient Offset mc comp. wind speed sensor (0-10 V) Wind speed Analog 0 10 V m/s 5 0 mc comp. wind speed sensor (4-20 ma) Wind speed Analog 4 20 ma m/s 3.09-11.86 28 48

Sensor connection 29 48

5.6 Wind direction sensors meteocontrol compact wind direction sensor (0 10 V) / (4 20 ma) Item Product name Item number Particularity Wind direction sensor meteocontrol 423.411 Output: 4 20 ma compact Wind direction sensor meteocontrol compact 423.431 Output: 0 10 V Connection Wire color Use Yellow Wind direction signal GND Green Wind direction signal (4 20 ma) Gray Power supply for heater (24 V AC or DC +) Pink Heater GND (24 V DC -) White Power supply for sensor (24 V AC or DC +) Brown Sensor GND (24 V AC or DC -) Configuration data Sensor Measurement Input Unit Gradient Offset mc compact wind direction (0-10 V) Wind direction Analog 0 10 V 36 0 mc compact wind direction (4-20 ma) Wind direction Analog 4 20 ma 22.5-90 30 48

Sensor connection 31 48

5.7 Weather stations Compact weather station WS501 / WS510 / WS600 UMB (Modbus RTU) Item Product name Item number Compact weather station WS501 UMB 423.307 Compact weather station WS510 UMB 423.312 Compact weather station WS600 UMB 423.306 Connection Wire color Use Green RS485 bus wire A (+) Yellow RS485 bus wire B (-) Brown Power supply for sensor (+24 V DC) White Sensor GND (-) Red Power supply for heater (+24 V DC) Blue Heater GND (-) Set the bus address on the compact weather station (see compact weather station documentation). If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). 32 48

Sensor connection 33 48

6. Power quality analyzers 6.1 Janitza power quality analyzers UMG604 (Modbus RTU) Item Product name Item number Particularity Power quality analyzer UMG 604 422.128 Power supply: 230 V AC Power quality analyzer UMG 604 422.129 Power supply: 24 V DC Set the bus address on the power quality analyzer (see power quality analyzer documentation). If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. To ensure sufficient query speed for the power control, it is recommended to operate the power quality analyzer as a single device on the bus. 34 48

Sensor connection 35 48

7. Energy meter 7.1 Three-phase energy meter ALE3 (Modbus RTU) energy meter Item Product name Item number Energy meter ALE3 424.202 Set the bus address on the energy meter (see energy meter documentation). If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. Energy meter suitable for IPL function 36 48

Sensor connection 37 48

Energy meter ALE3 (S0) Item Product name Item number Energy meter ALE3 424.204 Pulse value of the S0 interface is 1000 pul/kwh Energy meter suitable for IPL function Configuring the IPL meter In the factory, the meter s S0 interface is set up in a way that allows for pulses to be transmitted in both directions (in and out), when energy is flowing. With this setting it is not possible to determine the direction of flow. To use the meter for IPL you will need to configure the S0 interface for one energy flow direction. You will need to make the following settings, depending on the recorded measurement. Measurement Use Setting Energy fed into the grid Feed-in meter Out mode Energy drawn from the grid Import meter In mode Energy used by electrical equipment Consumption meter In mode 38 48

Sensor connection 39 48

8. String measuring technology 8.1 meteocontrol string measuring technology i catcher 8-1B, i catcher 16-1B, i catcher 24-1B (Modbus RTU) Item Product name Item number i catcher 8-1B 423.101 i catcher 16-1B 423.116 i catcher 24-1B 423.103 Set the bus address on the i'catcher (see i'catcher documentation). If this is the last bus device on the RS485 bus, set the terminating switches (Term.) to On. Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). 40 48

(1) RJ12 connector (WEB'log), (5) Last i catcher RS485/RS422 (2) Pinout of Connect Universal RS (6) Terminating resistor 120 Ω (3) Terminals (i catcher) (7) Bus cable (4) First i catcher 41 48

Connection i catcher, central power supply, separate shield Connection i catcher, central power supply, connected shield 42 48

Connection i catcher, decentralized power supply, separate shield Connection i catcher decentralized power supply, connected shield 43 48

String Monitoring Units SMU 0825, SMU 1225, SMU 1625, SMU 2422 (Modbus RTU) Item Product name Item number String Monitoring Unit 0825 421.925 String Monitoring Unit 1225 421.926 String Monitoring Unit 1625 421.927 String Monitoring Unit 2422 421.928 Set the bus address on the String Monitoring Unit (see String Monitoring Unit documentation) If the device is the last one on the RS485 bus, terminate the bus with a 120 Ω terminating resistor. Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). 44 48

Sensor connection 45 48

46 48

47 48

48 48

Text and illustrations represent state-of-the-art technology at the time of printing Subject to technical modifications We assume no liability for printing errors. Version 20160425