42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor



Similar documents
MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Refrigeration Basics 101. By: Eric Nelson

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

New Trends in the Field of Automobile Air Conditioning

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

Increasing the evaporation temperature with the help of an internal heat exchanger

UNDERSTANDING REFRIGERANT TABLES

Energy savings in commercial refrigeration. Low pressure control

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Air Conditioning 101. STN Presentation AC101

How To Calculate The Performance Of A Refrigerator And Heat Pump

AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

Automobile Air Conditioning Primer

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

A/C refrigerant system, overview

Rusty Walker, Corporate Trainer Hill PHOENIX

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

Characteristics of Evaporators

Silicagel-water adsorption cooling prototype system for mobile air conditioning

UNIT 2 REFRIGERATION CYCLE

Mohan Chandrasekharan #1

Chapter 3.4: HVAC & Refrigeration System

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Testing methods applicable to refrigeration components and systems

Thermodynamics - Example Problems Problems and Solutions

Advanced Engine Cooling Systems for Vehicle Application

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

Combination Ductless Heat Pump & Heat Pump Water Heater Lab and Field Tests

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

APAds Air Conditioning Protection and Control System. Technical Help Frequently Asked Questions

Air Conditioning System

Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

Optimal operation of an Ammonia refrigeration cycle

Heat Recovery In Retail Refrigeration

How To Know If A Refrigeration System Is Efficient

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

HVAC-02, Air Conditioning Troubleshooting and Repair

DRAFT. Appendix C.2 - Air Conditioning Thermodynamics 1

Why and How we Use Capacity Control

How To Save Energy With High Pressure Control

Development and testing of a multi-type air conditioner without using AC inverters

Technical Support Bulletin Nr. 20 Special AC Functions

HEATER, AIR CONDITIONING AND VENTILATION

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

Failure code manual. content

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Signature and ISX CM870 Electronics

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Hybrid Air Conditioning Systems Overview

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Heavy-Duty Air Conditioning And Heater Service

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

REFRIGERATION (& HEAT PUMPS)

SMM. Installation Operation Maintenance

ON-VEHICLE INSPECTION

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Condensers & Evaporator Chapter 5

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Glossary of Heating, Ventilation and Air Conditioning Terms

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

AIR REVERSING R744 AIR CONDITIONING SYSTEM

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

HOW HVAC WORKS. How HVAC. Works PAGE 1

Basic Technology Series

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Section 6. Introduction to Automatic A/C. Automatic Temperature Control

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Zero Emission Engine. An Economic and Environmental Benefit

Electric Coolant Pumps. Always at the Correct Temperature

Refrigeration & HVAC

K. G. Duleep President, H-D Systems Presented at the Michelin Bibendum Berlin, May 2011

EMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

MP-4000 Alarm List (Software version or later)

The Second Law of Thermodynamics

Transcription:

2004-01-1478 42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor Bapiraju Surampudi, Mark Walls, Joe Redfield, Alan Montemayor Southwest Research Institute Chips Ingold Modine Manufacturing Jim Abela Masterflux Copyright 2003 SAE International ABSTRACT The electrification of accessories using a fuel cell as an auxiliary power unit reduces the load on the engine and provides opportunities to increase propulsion performance or reduce engine displacement. The SunLine Class 8 tractor electric accessory integration project is a United States Army National Automotive Center (NAC ) initiative in partnership with Cummins Inc., Dynetek Industries Ltd., General Dynamics C4 Systems, Acumentrics Corporation, Michelin North America, Engineered Machine Products (EMP ), Peterbilt Motors Company, Modine Manufacturing and Masterflux. Southwest Research Institute is the technical integration contractor to SunLine Services Group. In this paper the SunLine tractor electric Air Conditioning (AC) system is described and the installation of components on the tractor is illustrated. The AC system has been designed to retrofit into an existing automotive system and every effort was made to maintain OEM components whenever modifications were made. Hardware modifications were limited to replacing the engine driven compressor for a 42 volt DC driven one, exchanging the expansion orifice for a thermal expansion valve and positioning the components to minimize the length of refrigerant lines. The thermodynamics and PID control algorithms are discussed. Closed loop test results are presented in controlled ambient conditions. Analysis of reversed Carnot cycle changes due to transient operation and coefficient of performance changes are given. INTRODUCTION The engine driven air conditioning system on the 2002 Peterbilt 385 is used for maintaining a comfortable incab temperature and as a windshield defroster. The Original Equipment Manufacturer (OEM) system includes a Sanden SD7 engine driven compressor that draws approximately 6 kw at full load. One disadvantage of this compressor is that it is the same one that is used on all of their trucks, and therefore it is sized for the trucks with the full size sleeper. Peterbilt and Modine engineers have designed this system to provide up to 25000 BTU/hr of cooling. Other disadvantages of having the engine driven compressor include constant parasitic losses from clutch drag, inability to operate the compressor in its efficient zones, and packaging. BASICS Block Diagram The block diagram of the air conditioning system is shown in Figure 1. The locations of instrumentation of different parameters are shown in this figure. Two pressures (Compressor Outlet after condenser and compressor inlet or evaporator outlet) and six temperatures were measured for purposes of analysis and control. The state of the refrigerant at compressor inlet is named as1, at compressor outlet as 2, at condenser outlet as 3 and evaporator outlet as 4. Objectives The objectives of this paper are to present the preliminary steps involved in installing and commissioning an electrical air conditioning system.

Compressor High Pressure Condenser Outlet Temp Receiver/ Dryer Expansion Valve 4 ADVANTAGES/DISADVANTAGES 3 Evaporator Inlet Temp Warm Air Condenser Cool Air Flow due to Vehicle and Fan Cabin Air Temp Evaporator AC Evaporator Temp (Air Side) Compressor High Figure 1 Block Diagram of Air Conditioning System with Instrumentation Points The advantages of electrification of accessories such as air conditioning system are multifold. The direct load on the engine is reduced. The efficiency penalty for transforming the energy from mechanical to electrical form can be made up by efficiency gains of de-coupling the duty cycle of air conditioning compressor and engine. The control of the compressor has the additional degree of freedom in that its speed of operation is not statically linked to engine speed. The operation of the air conditioning system will be just as effective when the engine is idling or when the engine is at different power levels. INSTALLATION AND COMMISSIONING Compressor AC Compressor Low Pressure and The OEM 134a air conditioning system consisted of a compressor, condenser, fixed orifice, evaporator, and an accumulator. To ease the transition into an electric A/C system, some of the OEM components, such as the evaporator and condenser were retained as well as using 134a as the refrigerant. The mechanical compressor, fixed orifice, and accumulator were replaced with an electric compressor, thermal expansion valve and a receiver/dryer, respectively. For the A/C system to work properly and efficiently, size matching of the components must be considered. The compressor was sized for enough capacity to cool the cabin of the vehicle in 115 O F ambient conditions. The OEM 1270 square inch condenser is oversized for this application, but does not degrade system performance. A thermal expansion valve (TXV) was chosen to match the compressor capacities. Finally the large OEM evaporator is still in use, but might be replaced in the future with a smaller capacity unit to improve system efficiency. 2 1 The 10 cubic inch Sanden SD7 7 cylinder compressor was replaced with a 42 volt DC Masterflux compressor. This variable speed rolling piston compressor has a max capacity of 16500 Btu/hr as compared to the 25000 Btu/hr OEM compressor. The smaller capacity works for this application because of the small cab volume in the day cab Peterbilt 385. This more efficient design not only allows the max power consumption to be cut by more than one third, but also allows for control of the compressor speed since it is no longer coupled with the engine. The OEM fixed orifice was the next item to be replaced. A Parker-Hannifin TXV was used in its place to further improve system efficiency. The 16000 Btu/hr capacity TXV controls the liquid flow rate through the evaporator by maintaining the superheat temperature or the fluid exiting evaporator to 6.5 F. The use of this TXV allows a much wider range of operating conditions, such as compressor speed and was a necessary step to take full advantage of the variable speed compressor. The physical locations and line lengths allow for another efficiency gain. As seen in figures X OEM System, and X 42V System, a considerable drop in line length can be seen. Another point to be seen in the figures is the replacement of the accumulator with a receiver/dryer. Powered by the 42-volt bus, the electric compressor is controlled through the Masterflux variable speed power electronics, which takes a speed setpoint value from RPECS (Rapid Prototyping Electronic Control System). The RPECS controls the compressor speed based on some of the pressure and temperature instrumentation in the system. This instrumentation includes pressure, and temperature sensors on the condenser outlet, and on the evaporator outlet, measuring the subcooled and superheated values of the refrigerant. Two more temperature sensors are also used for control, one placed in the air stream of the evaporator outlet and one measuring the cabin temperature. The control method is discussed below. Tuning the new system for the proper refrigerant amount involved adding 134a refrigerant in small increments while monitoring the subcooled temperatures out of the condenser and superheated temperatures out of the evaporator. With the proper amount of refrigerant, a subcooled value of 10-15 F and a superheated value of 2-5 F were observed. CONTROLS The control system takes the values of sensors described in the block diagram in Figure 2. A variable speed compressor receives an analog voltage command from the SwRI RPECS (Rapid Prototyping Electronic Control System) and all instrumented signals are wired to RPECS. A brief introduction to RPECS is given below.

Test Results The cab doors were closed and an external fan was blowing across the radiator for simulating airflow during truck movement. The closed loop test results are shown in the following figures. The PID controller was tuned for stability and steady state error of ±1 C. Two-step inputs in desired cab temperature were given and response of actual cab temperature is shown in Figure 4. Figure 2 SwRI Rapid Prototyping Electronic Control System (RPECS ) is used to control the 42 V AC System The compressor command from the PID controller and the power consumption (kw) of the compressor are shown in Figure 5. We can notice that as the desired temperature is achieved the compressor goes to its minimum setting of 1V. We can see that peak compressor power consumption is 1.5 kw and steady state consumption is 1 kw. RPECS The RPECS has a convenient PC/104 form factor with compact packaging for shorter wiring harness lengths while retaining full desktop processing power. It uses QNX 4.25 a hard real-time POSIX compliant operating system capable of supporting preemptive multitasking. The AC control software was developed using ANSI C. RPECS is RS232/RS485 compatible and can communicate using TCP/IP, CAN J1939 protocol, or MODBUS protocol. It has a built in UPS to handle voltage drop during cranking of the engine. It can tolerate supply voltage changes from 8 to 32 V DC. It can also operate between -25 to 60 deg C ambient temperatures. A single FPGA provides flexible digital I/O, logic and capability to measure/send PWM signals. The Graphical User Interface is installed on a laptop running Redhat Linux capable of communicating with QNX RTOS using TCP/IP. The hardware is easily extendible to accommodate required analog inputs/outputs and digital inputs/outputs. Figure 4 PID Controller Performance to Step Changes in Desired Cab CONTROL BLOCK DIAGRAM The block diagram for preliminary control system developed for commissioning of the AC system is shown in Figure 3. This system is to ensure that driver demanded cab temperatures are feasible with the components picked under controlled ambient conditions. It consists of a proportional integral controller that takes the error between driver desired cab temperature and actual cab temperature as input and produces a compressor speed set point command as an output. Desired Cab + - Actual Cab PID Controller Figure 3 Preliminary AC Control System Compressor Speed Figure 5 Compressor Command and Power commanded by the PID controller The pressures across the compressor are shown in Figure 6. We can note that the inlet pressure goes up while the outlet pressure falls during initial portion of the step change. The oscillations observed are due to the expansion valve hunting. Corresponding temperature

effects are shown in Figure 7. The valve expansion valve orifice has been set to maintain a superheated 6.5 F (or 3.5 C) at compressor inlet and its hunting (Figure 8) with respect to the superheated temperature (difference between Compress inlet temperature and corresponding saturated temperature). This hunting is seen normally in automobile A/C systems with variable valve orifice feedback. Figure 8 Expansion Valve hunting during attempts to achieve the superheat set point of 3.6 C (6.5 F) at Compressor Inlet ANALYSIS Figure 6 Compressor Inlet and Outlet Pressures (Not the oscillations due to expansion valve hunting Figure 7 Variations during tracking of desired cab temperature The reverse Carnot cycle is shown in Figure 9. State 1 is compressor inlet, State 2 compressor outlet, 3 is expansion valve outlet and 4 is evaporator inlet. The expansion valve has been assumed to have adiabatic pressure drop and the pressure drops across the condenser and evaporator have been neglected. The enthalpies have been suitably calculated based on whether the refrigerant is superheated, subcooled or two phase mixture. The two thick magenta lines are liquid to vapor and vapor to liquid conversion points. The cyan blue lines are constant temperature lines in the superheated region. The cycle is plotted just for the first step response input. The cycle lines that are red and thin are for the beginning of step response and the lines that are blue and thick are for steady state or end part of the response. The color and line thickness progresses smoothly between the two extremes. We can notice that area is much higher in the transient region and smaller at steady state. The superheated point at state 1 scatters due to the expansion valve hunting and can be improved to stay closer to 6.5 F by tuning the orifice set point and the thermal inertia of the evaporator. Pinching off additional lines on the evaporator can change the thermal inertia. We can compute from the deviation of the process of compression (1 to 2) from isentropic line, the average operating compressor efficiency is about 60%.

Pressure (psia) Enthalpy (BTU/lb) Pressure (psia) Figure 9 Reverse Carnot Cycle Variation during transient associated with first step change The process for second step is shown in Figure 10. We can notice that significant additional work for the second step due to the low temperature set point (or the cold region in theoretical reverse Carnot cycle). These maps point to the targeted tuning of the AC system for improving the operating efficiency and are useful tool during commissioning of the system. The Coefficient of performance (COP) is plotted in Figure 11. The constant pressure drop assumptions and electrical sensor noise cause an actual COP to be slightly higher than the theoretical Carnot COP during initial transient. During steady state the COP converges to 2.8 compared to the possible theoretical COP of 3.2. Figure 11 Coefficient of performance of the 42V AC System (2.8) is close to the theoretical limit (3.3) CONCLUSION The 42 V electrical AC system has been installed in a Class 8 tractor and commissioning has been completed. Preliminary control strategies and analysis tools indicate promising areas of tuning the hardware and controller for minimizing the energy consumption of the system. Although the present work is using a Class 8 tractor platform the approach and technique is generic enough for all classes of passenger automobiles. With clear indications of improvement in emissions and fuel economy with fuel cells and the convergence of the auto industry towards a 42 V electric system the two technologies are synergistic. Hybrid vehicles using electrification of accessories with a small fuel cell and the resulting reduction of engine size can pave the way for full-fledged fuel cell vehicles of the future. Future work will target optimization of the AC system and developing mathematical models for exploring model based control strategies. ACKNOWLEDGMENTS Enthalpy (BTU/lb) Figure 10 Reverse Carnot Cycle Variation during transient associated with second step change The authors would like to thank the SunLine Services Group, The United States Army National Automotive Center (NAC ), Cummins Inc., Dynetek Industries Ltd., General Dynamics C4 Systems, Acumentrics Corporation, Michelin North America, Engineered Machine Products (EMP), Peterbilt Motors Company, Modine Manufacturing and Masterflux for their contributions to the Sunline integration project.

REFERENCES 1. Michael J. Moran and Howard N. Shapiro, "Fundamentals of Engineering Thermodynamics", John Wiley and Sons Inc, New York. 2. Dupont SUVA Technical Information Publication T134a-ENG, "Thermodynamic Properties of HFC- 134a"