FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

Similar documents
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Mohan Chandrasekharan #1

APPLIED THERMODYNAMICS. TUTORIAL No.3 GAS TURBINE POWER CYCLES. Revise gas expansions in turbines. Study the Joule cycle with friction.

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Thermodynamics - Example Problems Problems and Solutions

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

UNIT 2 REFRIGERATION CYCLE

Chapter 3.4: HVAC & Refrigeration System

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

SIMULATION OF THERMODYNAMIC ANALYSIS OF CASCADE REFRIGERATION SYSTEM WITH ALTERNATIVE REFRIGERANTS

42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation

Jet Propulsion. Lecture-2. Ujjwal K Saha, Ph.D. Department of Mechanical Engineering Indian Institute of Technology Guwahati 1

OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE. TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS

Condensers & Evaporator Chapter 5

Development of a model for the simulation of Organic Rankine Cycles based on group contribution techniques

AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY

Transient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2

The Second Law of Thermodynamics

How To Calculate The Performance Of A Refrigerator And Heat Pump

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Research on the Air Conditioning Water Heater System

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS *

Waste Heat Recovery through Air Conditioning System

Chapter 10: Refrigeration Cycles

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Business Model of Micro-Chp Efficiency and Energy Requirements

The Second Law of Thermodynamics

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Theory of turbo machinery / Turbomaskinernas teori. Chapter 4

New Trends in the Field of Automobile Air Conditioning

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Energy Saving by ESCO (Energy Service Company) Project in Hospital

AdSORPTION CHILLER NAK

CO MPa (abs) 20 C

Exergy: the quality of energy N. Woudstra

Author's personal copy

ME 201 Thermodynamics

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Experimental Analysis of a Variable Capacity Heat Pump System Focusing on the Compressor and Inverter Loss Behavior

Fluid Mechanics Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Silicagel-water adsorption cooling prototype system for mobile air conditioning

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

Energy savings in commercial refrigeration. Low pressure control

Applications in Mobile Air-Conditioning and Applications in Heat Pumps

Petroleum Refinery Hydrogen Production Unit: Exergy and Production Cost Evaluation

Diesel Cycle Analysis

STEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7

AIR REVERSING R744 AIR CONDITIONING SYSTEM

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Thermodynamical aspects of the passage to hybrid nuclear power plants

Warm medium, T H T T H T L. s Cold medium, T L

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

How To Know If A Refrigeration System Is Efficient

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

Stirling heat engine Internal combustion engine (Otto cycle) Diesel engine Steam engine (Rankine cycle) Kitchen Refrigerator

ANNEX 1. Analysis of scientific literature

THERMAL TO MECHANICAL ENERGY CONVERSION: ENGINES AND REQUIREMENTS

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

REFRIGERATION (& HEAT PUMPS)

COGENERATION. This section briefly describes the main features of the cogeneration system or a Combined Heat & Power (CHP) system. 36 Units.

INNOVATIVE AIR-CONDITIONING SYSTEMS FOR CONVENTIONAL AND ELECTRIC VEHICLES

Glossary of Heating, Ventilation and Air Conditioning Terms

Boiler efficiency measurement. Department of Energy Engineering

GEOTHERMAL POWER PLANT CYCLES AND MAIN COMPONENTS

A/C refrigerant system, overview

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Basics of Low-temperature Refrigeration

Unit 96: Marine Propulsion Power Plant

THE HUMIDITY/MOISTURE HANDBOOK

Transient Performance Prediction for Turbocharging Systems Incorporating Variable-geometry Turbochargers

OPTIMIZATION OF DIAMETER RATIO FOR ALPHA-TYPE STIRLING ENGINES

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

C H A P T E R T W O. Fundamentals of Steam Power

Energy Procedia Energy 00 Procedia (2011) (2012) 56 65

HVAC Efficiency Definitions

Refrigeration and Air Conditioning with Psychrometry

C H A P T E R F I V E GAS TURBINES AND JET ENGINES

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

The final numerical answer given is correct but the math shown does not give that answer.

A heat pipe heat recovery heat exchanger for a mini-drier

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Performance Analysis of Gas Turbine Integrated Geothermal Power Plant in Turkey: The Proposed Kizildere Project

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Transcription:

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM L. H. M. Beatrice a, and F. A. S. Fiorelli a a Universidade de São Paulo Escola Politécnica Departamento de Engenharia Mecânica Av. Prof. Mello Moraes, 2231 Cidade Universitária São Paulo, São Paulo, Brasil fiorelli@usp.br ABSTRACT The goal of this work is to develop a preliminary analysis on the feasibility of using an alternative automotive air conditioning system based on the Brayton cycle, to be assembled using a turbocompression-intercooling system configuration available in the market. The first step of the analysis was a thermodynamic study to define the system capacity and parameters for selecting the system components. The next step was to select from turbocompressor maps a suitable model for the application, and to determine pressures/temperatures throughout the system in order to evaluate intercooler capacity and select a suitable model available in the market. The impact of the turbocompression system was also analyzed in engine performance. The proposed turbocompression system requires 1,7 kw from the engine, which is very similar to a conventional air conditioning system requirement. In terms of weight, this preliminary analysis indicated that the proposed system is about 1,0 kg heavier than the conventional system. The analysis indicated that the alternative system is about 56% more expensive than the conventional one, but on the other hand presents a 24% lower maintenance cost. Considering the results of the preliminary analysis, the proposed system is technically feasible for application in automotive air conditioning, but requires a design optimization process in order to reduce its weight and initial costs, which might allow lower maintenance costs to payback the alternative system. Keywords: Automotive Air Conditioning, Brayton Cycle, Thermoeconomical Analysis. NOMENCLATURE COP coefficient of performance c p specific heat at constant pressure h specific enthalpy k isentropic coefficient m& mass flow rate p pressure Q & heat transfer T temperature W & power Greek symbols φ relative humidity η efficiency ω absolute humidity Subscripts 0 external a air C compressor E evaporator outlet H warm region in inlet L cold region net net out outlet s isentropic w water INTRODUCTION The automotive air conditioning systems in use are based on the vapor compression refrigeration cycle, and the required power to the system is provided to the compressor by the vehicle engine through a magnetic clutch. Such power supply to compressor has a significant impact on engine fuel consumption and power transfer to tires, particularly for economic class cars. According to Kaynakli & Horuz (2003), a typical automotive air conditioning system requires a compressor power of about 1,6 1,7 kw from the engine. Nowadays there is a global scenario of instability in the petrol market, with a price increase tendency in the medium/long term, as well as environmental concerns about pollution and global warming. Internal combustion engine-driven vehicles are an important source of pollution, and the optimization of peripheral systems connected to the engine, such as the air conditioning system, is important and required to reduce vehicle fuel consumption and pollutant emissions. Another environmental aspect that affects air conditioning systems is that the halogenated refrigerant typically used in the system contributes to global warming, and the development of a system that eliminates such substances is also important. 10 Engenharia Térmica (Thermal Engineering), Vol. 8 N o 02 December 2009 p. 10-14

Considering these aspects, the goal of this work is to develop a preliminary technical-economical analysis on the viability of using an alternative turbocompression automotive air conditioning system based on the Brayton cycle, to be assembled using a turbocompression-intercooling system configuration available in the market, as shown in Fig. 1. This kind of system is already in use in aircrafts and it is interesting in environmental terms since it uses air as working fluid, thus eliminating the impact of halogenated refrigerants in global warming. This configuration may also optimize fuel usage since it retrieves energy from combustion gases to power AC system. Figure 1. Turbocompression automotive air conditioning system. Figure 2. Vapor compression refrigeration cycle (Moran & Shapiro, 2004). REFRIGERATION CYCLES As stated before, nowadays automotive air conditioning systems are based on the vapor compression refrigeration cycle (Fig. 2). Heat and work transfers in the cycle are given by Eq. (1) considering steady state and negligible potential and kinetic energy variations: Q & W & = m & hout hin (1) Cycle performance can be evaluated by coefficient of performance COP, given by: Q& L h1 h4 COP = = C h2 h1 (2) The reverse Brayton closed refrigeration cycle (Fig. 3) is the theoretical cycle that approaches the proposed turbocompression AC system presented in Fig. 1. In this cycle, isothermal heat exchanges are replaced by isobaric ones, as shown in the T-s diagram of Fig. 3. Considering reversible processes, COP for such cycle is given by: Q& 4-1 T1 T4 COP = = net 2 1 3 4 ( T T ) ( T T ) (3) Figure 3. Reverse Brayton closed refrigeration cycle (Moran & Shapiro, 2004) Engenharia Térmica (Thermal Engineering), Vol. 8 N o 02 December 2009 p. 10-14 11

COOLING LOAD DEMAND EVALUATION In order to evaluate the cooling load demand for automotive air conditioning systems, the parameters listed in Table 1 were assumed. From such values, peak cooling load demand can be evaluated by Eq. (4): Q & L = m & a he h0 ωe ω0 hw (4) Air enthalpies and absolute humidities of Eq. (4) can be evaluated from Table 1 values and psychometric charts, and condensate enthalpy h w can be obtained from vapor tables. Values for the present case are listed in Table 2. Considering such values, cooling load demand is: Q & L = 5,68 kw = 1,6 TR (1) Table 1. Parameters for cooling load demand evaluation (Forrest & Bhatti, 2002) Parameter Value T 0 38 C φ 0 40% p 0 101,325 kpa T E 10 C φ E 100% m& a 0,1285 kg/s Table 2. Air and water properties for Equation (4) Property h E h 0 ω E ω 0 h w Value 81,0 kj/kg 29,0 kj/kg 0,0078 kg vapor /kg dry air 0,0168 kg vapor /kg dry air 42,0 kj/kg SYSTEM DESIGN AND THERMODYNAMIC ANALYSIS As stated before, the intent of this work is to analyze the viability of assembling an alternative turbocompression automotive air conditioning system based on the Brayton cycle using a turbocompression-intercooling system configuration available in the market. Thus, the first step of the development was to select a suitable turbocompressor model for the application. Figure 4 presents the compressor and turbine maps of the selected turbocompressor system. Figure 4. Turbocompressor maps for the selected model (Garrett, 2010) Assuming a compressor speed of 100.000 rpm and the desired mass flow rate, the turbocompression system operates with a pressure ratio of 1,25 and an isentropic efficiency of about 68%. Considering such values and also assuming air as ideal gas with constant c p, it is possible to evaluate air temperature at compressor outlet from isentropic compression: ( ) T2,s T1 = p1 p2 T2,s T1 η s = T2 T1 k 1 k T2 = 47,6 C (6) From the conditions in the vehicle interior and assuming negligible air velocity (worst case scenario), it is possible to evaluate, from Bernoulli equation, that the vehicle interior pressure is equal to p 4 = 101,8 kpa. Considering the vehicle interior conditions and assuming isenthalpic process in an expansion device, air temperature at the expansion device inlet is: 12 Engenharia Térmica (Thermal Engineering), Vol. 8 N o 02 December 2009 p. 10-14

p3 = p2 T3 = 14,7 C h3 = h4 (7) With the air temperatures at compressor outlet and expansion device inlet, the intercooler required capacity is: Q & intercooler = m & acp,a T2 T3 = 4,24 kw (8) Considering the required intercooling capacity and the available systems in the market, a 2,0 m 2 face area air-air intercooler with an auxiliary evaporative cooling system was selected. SYSTEM IMPACT ON ENGINE PERFORMANCE Considering the experimental data provided by the manufacturer, the turbocompressor increases the outlet engine pressure by 3,5% in the worst case scenario, and the impact on engine power is nearly the same: without turbo 1,035 with turbo (9) For a typical small-size car with a maximum engine power of 51 kw, turbocompressor impact on the engine is 1,7 kw, which is similar to the typical compressor power consumption of a conventional air conditioning system (about 1,6-1,7 kw according to Kaynakli & Horuz, 2003). Another aspect to be considered in terms of engine impact is the system weight. The weight of the proposed system was evaluated to be about 11,5 kg, while the conventional system weighs approximately 10,5 kg. Taking these aspects into account, this first approach indicates that the proposed system would increase fuel consumption, mainly due to higher weight. Nevertheless, considering that system weights are very similar, an optimizing process on proposed system might eliminate such fuel consumption increase. ENVIRONMENTAL IMPACT As stated before, an environmental aspect that affects air conditioning systems is that the halogenated refrigerant typically used in the system contributes to global warming, and the development of a system that eliminates such substances is important. One of such refrigerants is HFC 134a (tetrafluoroethane), typically used in conventional automotive air conditioning systems. According to the Brazilian automotive manufacturers association (ANFAVEA), about 90 tons of HFC 134a are released into the atmosphere every year due to leakages and system maintenances (. Such amount has a significant environmental impact. So far, the main advantage of the proposed system is connected to this aspect. Considering that it uses air as refrigerant, the turbocompression AC system eliminates this environmental impact. COST COMPARISON In order to evaluate the economic viability of the proposed system, initial and routine maintenance costs were compared for both systems. Initial costs were evaluated by the cost of the main components of both systems, and maintenance costs were considered for a three-year period, which is the typical warranty period for a new vehicle. Tables 3 and 4 present the comparison results, indicating that the alternative system is about 56% more expensive than the conventional one; on the other hand, it presents a maintenance cost that is 24% lower. Nevertheless, considering the three-year warrant period, the savings on maintenance cost are insufficient to pay back the higher initial cost. CONCLUSION A preliminary feasibility analysis of an alternative automotive air conditioning system based on the Brayton cycle was presented, to be assembled using a turbocharging system adapted for this purpose. Table 3. Initial costs for conventional and proposed AC system Conventional System Main components Compressor 800,00 Evaporator / Expansion Device 500,00 Condenser 400,00 Total Initial Cost 1.700,00 Proposed System Main components Turbocompressor 2.000,00 Intercooler 300,00 Evaporative System 200,00 Expansion Device 150,00 Total Initial Cost 2.650,00 Engenharia Térmica (Thermal Engineering), Vol. 8 N o 02 December 2009 p. 10-14 13

Table 4. Maintenance costs for conventional and proposed AC system Conventional System Maintenance routine Refrigerant charge 100,00 System sanitation 200,00 Air filter replacement 180,00 Total Maintenance Cost 480,00 Proposed System Maintenance routine System sanitation 200,00 Air filter replacement 180,00 Total Maintenance Cost 480,00 compression ratios at levels of lower rotation and lower weight system, which would result in a reduction in vehicle fuel consumption, thus allowing the use of the proposed system. REFERENCES Forrest, W., and Bhatti, M., 2002, Energy efficient automotive air conditioning system, Proceedings of the SAE 2002 World Congress, Detroit, USA. Kaynakli, Ö., Horuz, I., 2003, An experimental analysis of Automotive Air Conditioning System, International Communications in Heat and Mass Transfer, Vol. 30, No. 2, pp. 273-284. Moran, M., Shapiro, H., 2004, Fundamentals of Engineering Thermodynamics, 5 th. Ed., John Wiley & Sons, Hoboken, USA, 874p. Garret, 2010, Garrett Product Catalog, <http://www.turbobygarrett.com/turbobygarrett/catel og/turbochargers/gt15/gt1548_466755_3.htm>. The first part of this study was the thermodynamic analysis of the system, from which a suitable turbocompressor system and an air-air intercooler with auxiliary evaporative cooling subsystem were selected. The next step was an evaluation of the impact of the proposed system on vehicles engine fuel consumption, which indicated that the proposed system has a power requirement similar to that of the conventional system. Concerning system weight, the analysis indicated that the proposed system is about 1,0 kg heavier than the conventional system. This is a negative aspect of the proposed system, since it indicates higher fuel consumption. Nevertheless, considering that system weights are very similar, an optimizing process in the proposed system might eliminate such fuel consumption increase. The main advantage of the proposed system is the elimination of the environmental impact caused by the contribution of halogenated refrigerants to global warming. In terms of costs, the proposed system presents a 56% higher initial cost, but on the other hand it has a maintenance cost that is 24% lower. Nevertheless, considering a three-year warrant period, the savings on maintenance cost do not manage to pay back the higher initial cost. Considering the results of the preliminary analysis, the proposed system is technically feasible for application in automotive air conditioning, but requires a design optimization process in order to reduce its weight and initial costs, which might allow lower maintenance costs to pay back the alternative system. As a subsequent study, the suggestion is that new turbo compressors are addressed, which are not available in the domestic market, in search of better 14 Engenharia Térmica (Thermal Engineering), Vol. 8 N o 02 December 2009 p. 10-14