Bar Code Label Specification



Similar documents
actidata Bar Code Label Specification for LTO Ultrium Cartridges

Revision 5 - (Released April 2008) Added further definitions of RFID tag contents and testing requirements for RFID tag read range.

Layman's Guide to ANSI X3.182

THE VALSPAR CORPORATION

MEDIA LABELS. A Division of EDPH

Identification of products that require activation at the Pointof-sale. The global language of business. in Europe

To view this information... Installing additional tape drives page 5 Replacing a tape drive with the same configuration

Elfring Fonts, Inc. PCL MICR Fonts

Packaging Identification Standard

HP StorageWorks Tape Bar Code Label Requirements, Compatibility, and Usage

ELFRING FONTS INC. MICR FONTS FOR WINDOWS

Customer Barcoding Technical Specifications

Contents. Bar code data transmission specifications...b-1. A October 1997 i

LEAR Corporation Sweden. Odette Transport Label Guideline Vers. 1 Rev. 4

Price List - Ultrium LTO Data Cartridges Fujifilm, HP, IBM, SONY, Quantum, Maxell, Dell

Everything you wanted to know about data tape bar codes but were afraid to ask

The Layman's Guide to ANSI, CEN, and ISO Bar Code Print Quality Documents

BAR CODE CONTROL BAR CODE CONTROL - 1

Maximum Length = 4 lines of text, (10 or 8 Points or 6 or 7 LPB). Width of block no larger than 1.75 inches. Page 1 of 9

Programming Reference Guide HP USB Barcode Scanner

LTO label are. your labels to. environment. The human. label enables. Prefix. Tuesdays. The

North American Labeling Requirements (Canada, Mexico and United States) TRW PROCEDURE WA.D20.001

Technical guide 1. june 2011

Support Guide for Codification of Medicines

REVISION HISTORY Revision Description of Change Writer/Reviser. A New Release Julio Henriquez / Johan Martinsson / Dennis Quek

Bar Code & Label Layout Specification

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM

Sumitomo Electric Wiring Systems, Inc. Part Identification and Labeling Requirements

Ten steps to GS1 barcode implementation. User Manual

GS1-128 CARTON LABELING

Guardian Automotive Supplier Label Specification

GS1 bar code validation and verification

WM002 LCD Display Wall Mounting Kit Installation Guide. Welcome

UCC 128 Carton Label

Create!form Barcodes. User Guide

HP StorageWorks tape bar code label requirements, compatibility, and usage white paper

BARCODE PRINTING SET UP BARCODE PRINTING

Product Label Specification

Application of Data Matrix Verification Standards

Packaging Guidelines Version Date: 11/6/12. ABB Inc. Packaging Guidelines. Version 1.0. Page P08.W03 Rev 0

THE BASIC BACKUP GUIDE TAPE BACKUP STRATEGIES FOR THE SMALL-TO-MEDIUM BUSINESS

MH10 Shipping Label. Contents

2 Advanced Scanner Configuration Guide

Enhanced Bar Code Engine

Produce Traceability Initiative Best Practices for Formatting Hybrid Pallet Labels

Getting Started with IntelleView POS Administrator Software

Elo Touch Solutions Elo Tablet Software Update

RECOMMENDED PRACTICE 1600u CARGO POUCH LABEL (NEW)

Laser Barcode Scanner

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

TOLEDO MOLDING & DIE, INC.

HP Tape Automation Bar Code and RFID Labels

USER'S GUIDE NUSCAN 2100 Series

Parcel Labeling Guide

Magnum 224 LTO Library, StorageLibrary T24, or StorageLoader 2U LTO RIGHT LEFT. Shipping locks

QuickSpecs. HP Ultrium Media Overview

Motorola Receiving Bar Code Specification

QuickSpecs. HP Ultrium Media Overview

IBM Half High LTO Gen 4 SAS Tape Drive

The ID Technology. Introduction to GS1 Barcodes

Learn about OCR: Optical Character Recognition Track, Trace & Control Solutions

How To Use A Corona Mdi 110

ELECTRONIC DOCUMENT IMAGING

Unified Utility Manual Label Printer. Rev. 2.08

Laser Barcode Scanner User s Manual

Many government agencies are requiring disclosure of security breaches. 32 states have security breach similar legislation

Produce Traceability Initiative Best Practices for Formatting Hybrid Pallet Labels

FUJIFILM Recording Media U.S.A., Inc. LTO Ultrium Technology

Sony LTO Data Media Storage Tapes

UCC/EAN 128 SERIAL SHIPPING CONTAINER LABEL (SSCC-18)

The Barcode Printing option may be purchased for an additional cost. You will receive a CD that you will use to activate this feature.

3 Thermal Transfer Acrylate Label Material 3921

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

IBM Rational Rhapsody Gateway Add On. CaliberRM Coupling Notes

BAR CODE GUIDELINES Revision 12/18/2015

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

WHITE PAPER DECEMBER 2010 CREATING QUALITY BAR CODES FOR YOUR MOBILE APPLICATION

Barcode Labels Feature Focus Series. POSitive For Windows

simplify printing TX Guide v. 1. make IT simple Tricerat, Inc Cronridge Drive Suite 100 Owings Mills, MD , All rights Reserved

GS1-128 Label Specifications. Version 1.0

High Performance Visible Laser Diode Scanners

ECM (ELO-KIT-ECMG2-AND)

Version of Barcode Toolbox adds support for Adobe Illustrator CS

Laser Scanner Programming Guide (SE923 laser engine)

TROY Secure Print Enterprise Lite Users Guide

BAR CODE FORMAT REQUIREMENTS Europe DVD EDS027 Issue 1 Apr 2014

RDX. removable hard disk storage system. smart. simple. safe.

Ontrack PowerControls User Guide Version 8.1

Disk-to-Disk-to-Tape Backup

Transcription:

1Tandberg Data Corporation Bar Code Label Specification 2for LTO Ultrium Cartridges 1004080-000 Rev C #1004080-000C#

Copyright Disclaimer Copyright 2000 2007 by Tandberg Data Corporation. All rights reserved. This item and the information contained herein are the property of Tandberg Data Corporation. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the express written permission of Tandberg Data Corporation, 2108 55th Street, Boulder, Colorado 80301. Tandberg Data Corporation makes no representation or warranties with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Tandberg Data Corporation reserves the right to revise this publication without obligation to notify any person or organization of such revision or changes. Trademark Notices Exabyte, the Exabyte Logo, EZ17, M2, VXA, and VXAtape are registered trademarks; ExaBotics, MammothTape, and SmartClean are trademarks; SupportSuite is a service mark. Linear Tape-Open, LTO, the LTO Logo, Ultrium and the Ultrium Logo are trademarks of HP, IBM, and Quantum in the US and other countries. All other product names are trademarks or registered trademarks of their respective owners. Revision History Revision Date Description 000 August 2000 Initial Release B June 2004 Update address C April 2007 Converted to Tandberg Tandberg Data Corporation 2108 55th Street Boulder, Colorado USA 80301 www.tandbergdata.com/us 2 1004080

Contents About this Specification................................ page 4 Symbology............................................ page 4 Bar Code Characters................................... page 5 Encodation............................................ page 5 Quiet Zone............................................. page 5 Optical Specification.................................... page 6 Label Dimensions...................................... page 7 Volume Identifier Formats.............................. page 10 1004080 3

About this Specification This document provides specifications for creating bar code labels used on cartridges in Tandberg Data LTO Ultrium libraries. The specifications are defined to both standardize labels and allow users the option of purchasing or printing their own labels. This specification contains the following information about the bar code labels: Symbology Bar code characters Encodations Quiet zone Optical specification Label dimensions Volume identifier formats Symbology The LTO Ultrium cartridge label uses the bar code symbology of USS-39. A description and definition of this symbology is available from the Automatic Identification Manufacturers (AIM) specification Uniform Symbol Specification (USS-39) and the ANSI MH10.8M-1993 ANSI Barcode specification. 4 1004080

Bar Code Characters The bar code string consists of a start character, eight alphanumeric characters, and the stop character. Quiet zones precede and follow the start and stop characters. The first six characters may be any combination of upper case A through Z or 0 through 9 (for example, ABC123) to identify the cartridge volume. The last two characters are determined by the LTO Ultrium cartridge media type (for example L for LTO Ultrium and 1 for tape cartridge generation or drive manufacturer-unique identifier). Only upper case alpha A through Z or numeric 0 through 9 characters are allowed. Human readable characters may be used, provided there is not a conflict or interference with the automation code. The user specifies the format, colors, and location of the human readable characters. Encodation Refer to the AIM Uniform Symbol USS-39 specification for the description and format of the start character, identifier characters, and stop character. Quiet Zone The quiet zones are the areas preceding the start and after the stop characters. They are clear of any printing or reflective properties that could cause spurious reflections. The quiet zones are further defined in the AIM Uniform Symbol USS-39 specification. 1004080 5

Optical Specification The optical specifications for the bar code labels are listed below. Use the white calibration standard to calibrate the print contrast of the Mcbeth PCMII. Be sure the filter select switch is on position A for all calibration and measurements. The reflectivity of the white background (RW) is the reflectivity measured in the center of narrow spaces using the Mcbeth PCMII print contrast meter. The RW must be between 70% and 85%. At this measurement, isolated print defects and edge roughness are avoided. A spot is defined as an area anywhere within the white background in which the reflectivity is less than 65%. Spots may not be greater than 0.004 inches (0.102 mm) enclosed diameter. There may be no more than five spots in the bar code area per label. Spots may not be any closer to each other than 0.01 inches (0.254 mm). The reflectivity of the black areas (RB) may be measured anywhere within any black area on the bar code. The print contrast signal (PCS) is defined as (RW-RB)/RW and is measured using the Mcbeth PCMII print contrast meter. PCS must be a minimum of 0.85. Using the PCS measurement will avoid isolated print defects and edge roughness. A void is an area within a black area where the PCS is less than 0.85. No voids may be greater than 0.004 inches (0.102 mm) enclosed diameter. There may be no more than five voids in the bar code area per label. Voids may not be any closer to each other than 0.01 inches (0.254 mm). Note: For additional optical requirements and measurement techniques, refer to the AIM Uniform Symbol USS-39 specification. 6 1004080

Label Dimensions The following figure shows the bar code label dimensions. Note: Dimensions are given in inches with millimeters in parentheses. f 2x.170 Minimum (Quiet zone) [4.32] 3.110 +0/-.031 [79.00 +0/-.80] 2.917 0.015 [74.09 0.038] 0 0 0 3 2 1 L1 Alphanumeric characters 0.437 Minimum [11.10 Minimum].669 +0/-.031 [17.00 +0/-.80] Bar code The following table lists the bar code label dimension specifications. 1004080 7

Note: The LTO Ultrium label dimensions are derived using the AIM USS-39 specification. Specification Symbol height Dimension 0.44 inches (11.1 mm) minimum as measured to the inside of the edge roughness a Wide to narrow ratio 1:2.75 Narrow element width 0.017 inches + 0.001/ 0.003 inches (0.432 mm +0.03/ 0.076 mm) Nominal width of wide spaces and bars 0.047 inches (1.188 mm) Inter character gap 0.017 inches +0.001/ 0.003 inches (0.432 mm +0.03/ 0.076 mm) Bar code element width maximum Quiet zone at the beginning and end of printed bar code string Total bar code string length, including quiet zones Bar code string direction Edge roughness a Tolerances Variation between all wide bars, white and black Variation between all narrow bars, white and black Measured to the outside of the edge roughness a. Space width is then the distance between bar maxima. 10 narrow width = 0.17 inches (4.32 mm) Nominal 2.917 inches (74.088 mm) May be printed in either direction on the label but must begin/end with a valid start/stop character ( ) 0.0015 inches (0.038 mm) maximum 0.XXX± 0.005 inches, 0.XX±.0.03 inches) (0.XXX± 0.127 mm, 0.XX± 0.762 mm) Less than ± 0.0015 inches (0.0381 mm) Less than ± 0.0015 inches (0.0381 mm) 8 1004080

Specification Print side Label stock dimensions Minimum length for quiet zones, start-stop and data characters Minimum width Corner cut Dimension (Continued) Print the bar code string on the label so it is on the side of the label towards the hub 3.110 x 0.669 inches (79 17 mm) b Nominal 2.917 inches (74.088 mm) No less than 0.059 inches (1.5 mm) narrower than the cartridge label recess width 0.059 inches (1.5 mm radius) a The edge roughness is defined as the transition encountered as a horizontal line is moved vertically from all black to all white. The bar code edge is defined as the edge of all printed area attached to the bar. b Must fit within the label recess on the face of the cartridge without curling up on the sides or ends. 1004080 9

Volume Identifier Formats The volume identifier only uses ASCII characters A through Z (41h- 5Ah), 0 through 9 (30h-39h), and the combinations of CLN and DG{space} as described below. The prefix CLNvnnL1 is reserved for cleaning cartridges. The v field is an alphanumeric field to identify a drive-unique cleaning cartridge. The nn alphanumeric field is used to track individual cleaning cartridge activity (for example, usage and life). When the drive requires cleaning, it will request loading of the unique type cleaner cartridge. Diagnostic/Service cartridges use the prefix DG{space}vnnL1. The v field is an alphanumeric field to identify a drive-unique diagnostic cartridge, if required. The nn alphanumeric field identifies a specific diagnostic cartridge volume. The volume identifier field consists of six left-justified alphanumeric characters as specified in SCSI-3 Medium Changer Commands (SMC) ANSI NCITS 314-199X. The media identifier characters Lg are controlled characters. The L designates the LTO Ultrium type of cartridge. The next character g (alphanumeric) designates the generation of the LTO Ultrium cartridge. End of document 10 1004080