D RDC2 Controller d One digital controller manages both the generator set and



Similar documents
Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Diesel Engine Driven Generators Page 1 of 6

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Diesel Generating Set

DIESEL GENERATOR SETS

Spark-ignited generator set

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Technical Specification. Generating Set with Waukesha engine burning natural gas

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

It s storming outside. Neighbors have no power. For you, dinner s on in 15.

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Operation. Residential/Commercial Generator Sets. Models: 14/20RESA 14/20RESAL 20RESC 20RESCL. Controllers: RDC2 DC2.

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Industrial Generator Set Accessories

Frequently Asked Questions Generators

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Automatic Transfer Switch Controller

Magnum Mobile Generator MMG55 Specifications

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

20 kw. 20 kw ISO. Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine FEATURES

Centro-Matic Automatic Lubrication Systems System Controls

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Diesel Generator Set Model DFHC 60 Hz

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Generator Set Model DFMB 60 Hz

How To Control A Power Command Powerplant

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

New 27 hp 2 Cylinder Liquid-Cooled Engine

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Diesel Generator Set Model DGDK 60 Hz

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

APS100 Rental Generator Set Specification

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

C18 ACERT Fire Pump Tier bkw/ rpm

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Back-UPS Pro 1300/1500 Installation and Operation

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Explosion-Proof Electric Unit Heaters

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

POWER GENERATION.

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Atlas Copco Generators

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Industrial Generator Set Accessories

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Fronius IG Plus. The next generation grid-connected PV inverter

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

16/20/22 kw CENTURION SERIES

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

16/20/22 kw. 16/20/22 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Medical Air Systems: Scroll

Integrated Power Systems for Data Centers

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Industrial Generator Set Accessories

Operation 8.5/12/18RES 12/18TRES. Residential/Commercial Generator Sets. Models: Controller: Advanced Digital Control ADC-RES.

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Technical data. Danfoss DHP-A

Commercial Gas Furnace Upflow

Internet Office 500VA Tower Standby 120V UPS with USB port

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Continuous Power... Continuous Protection

Marine Generating Sets 3.7 to 50 kva

Annex-A TECHNICAL SPECIFICATION

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Everything you need for protection scheme testing

ENGINEERING ENGINEERING PERFORMANCE PERFORMANCE

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Digital Controllers ACTUATOR COMPATABILITY

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Transcription:

Models: 14/20RESA Multi-Fuel / The Kohler r Advantage High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra-low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with an industry-leading 5-year or 2000 hour limited warranty. Powerful Performance Exclusive Powerboostt technology provides excellent starting power. The Kohler 14 kw generator can easily startandruna5tonairconditioner.* Corrosion-Proof Enclosure The bold new Kohler design is completely corrosion proof, even in harsh seaside environments, and is impactresistant even at --34_ C(--30_ F). Fast Response Kohler generators restore power to your home quickly and reliably. Standard Features RC2 Controller d One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). d esigned for today s most sophisticated electronics. d Electronic speed control responds quickly to varying demand. d igital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality. Kohler Command PRO Engine Features d Kohler Command PROr OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. d Powerful, reliable air-cooled performance. d Simple field conversion between natural gas and fuels while maintaining emission certification. esigned for Easy Installation d Polymer base eliminates the need for a concrete mounting pad, reducing installation time and cost. d Fuel and electrical connections through the enclosure wall eliminate the need for stub-ups through the bottom. d Load connection terminal block allows easy field wiring. d esigned for outdoor installation only. Certifications d Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and. Note: CARB does not regulate emergency standby generators with outputs less than 50 HP. d UL 2200 listed (60 Hz model). d CSA certification available (60 Hz model). d GOST certified (Russia). d Accepted by the Massachusetts Board of Registration of Plumbers and Fitters Warranty d 5-year/ 2000 hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. d 18 month/ 1000 hour limited warranty for off-grid (non-standby) applications (Model 14RESA only). * Check the appliance manufacturer s specifications for actual power requirements. Consult a Kohlerr Power Systems professional to calculate your exact residential power system requirements.

Generator Ratings Standby Ratings Line Circuit Breaker Model Alternator Voltage Phase Hz kw/kva Amps kw/kva Amps Amps Poles 120 * 1 60 12/12 100 13/13 108 125 1 110/220 1 60 12/12 54 14/14 63 100 2 120/240 * 1 60 12/12 50 14/14 58 70 2 2F5 115/230 1 50 10/10 43 11/11 47 70 2 220[ 1 50 10/10 45 11/11 50 50 1 230 1 50 10/10 43 11/11 47 50 1 240[ 1 50 10/10 41 11/11 45 50 1 14RESA 120/208 * 3 60 12/15 41 13/16 45 50 3 127/220 3 60 12/15 39 13/16 42 50 4 120/240 * 3 60 12/15 36 13/16 39 50 3 2G5 220/380 3 60 12/15 22 13/16 24 32 4 277/480 3 60 12/15 18 13/16 20 25 3 220/380] 3 50 10/12 18 11/13 20 25 4 230/400 3 50 10/12 18 11/13 19 25 4 240/416] 3 50 10/12 17 11/13 19 25 4 120 * 1 60 18/18 150 20/20 166 175 1 110/220 1 60 18/18 81 20/20 90 100 2 120/240 * 1 60 18/18 75 20/20 83 100 2 2F7 100/200 1 50 15/15 75 16/16 80 80 2 115/230 1 50 15/15 65 16/16 69 100 2 220[ 1 50 15/15 68 16/16 72 80 1 230 1 50 15/15 65 16/16 69 80 2 240[ 1 50 15/15 62 16/16 66 80 1 20RESA 120/208 * 3 60 17/21 58 17/21 58 70 3 110/220 3 60 17/21 55 17/21 55 80 3 127/220 3 60 17/21 55 17/21 55 80 4 120/240 * 3 60 17/21 51 17/21 51 60 3 2G7 220/380 3 60 17/21 32 17/21 32 40 4 277/480 3 60 17/21 26 17/21 26 30 3 100/200 3 50 14/17 50 15/18 54 63 3 220/380] 3 50 14/17 26 15/18 28 32 4 230/400 3 50 14/17 25 15/18 27 32 4 240/416] 3 50 14/17 24 15/18 26 32 4 * UL listed. [ 50 Hz single-phase models are factory-connected as 230 volts. Field-adjustable to 220 or 240 volts by an authorized service technician. ] 50 Hz 3-phase models are factory-connected as 230/400 volts. Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and IN 6271. GENERAL GUIELINES FOR ERATING: ALTITUE: erate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: erate 2% per 5.5_C(10_F) temperature increase above 16_C(60_F). Availability is subject to change without notice. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co. generator distributor for availability.

Alternator Specifications Specifications Manufacturer Kohler Alternator Specifications Alternator Features Alternator Type 2-Pole, Rotating Field Leads, quantity 2F5, 2F7 4 2G5, 2G7 12 Voltage regulator igital Insulation: NEMA MG1-1.66 Material Class H Temperature rise 130_C Standby Bearing: quantity, type 1, Sealed Coupling irect Amortisseur windings Full Voltage regulation, no-load to full-load RMS ±1.0% One-step load acceptance 100% of Rating Peak motor starting kva: (35% dip for voltages below) 14RESA: 240V, 1 ph 2F5 (4 lead) 33 (60 Hz) 220 V, 1 ph 2F5 (4 lead) 26 (50 Hz) 480 V or 240 V, 3 ph 2G5 (12 lead) 54 (60 Hz) 380 V or 220 V, 3 ph 2G5 (12 lead) 38 (50 Hz) 20RESA: 240 V, 1 ph 2F7 (4 lead) 41 (60 Hz) 220 V, 1 ph 2F7 (4 lead) 28 (50 Hz) 480 or 240 V, 3 ph 2G7 (12 lead) 69 (60 Hz) 380 or 220 V, 3 ph 2G7 (12 lead) 55 (50 Hz) Compliance with NEMA, IEEE, and ANSI standards for temperature rise. Self-ventilated and dripproof construction. Windings are vacuum-impregnated with epoxy varnish for dependability and long life Superior voltage waveform and minimum harmonic distortion from skewed alternator construction. igital voltage regulator with 1.0% no-load to full-load RMS regulation. Rotating-field alternator with static exciter for excellent load response. Total harmonic distortion (TH) from no load to full load with a linear load is less than 5%.

Engine Engine Specifications 14RESA 20RESA Manufacturer Kohler Engine: model, type CH740 4-Cycle Cylinder arrangement V-2 Application ata Fuel Pipe Size CH1000 4-Cycle isplacement, cm 3 (cu. in.) 725 (44) 999 (61) Bore and stroke, mm (in.) 83 x 67 (3.27 x 2.64) 90 x 78.5 (3.54 x 3.1) Compression ratio 9:1 8.8:1 Main bearings: quantity, type 2, Parent Material Rated RPM 60 Hz 3600 50 Hz 3000 Max. engine power at rated rpm, kw (HP), 60 Hz 17.6 (23.6) 23.0 (30.9), 50 Hz 15.8 (21.2) 20.0 (26.8) gas, 60 Hz 15.3 (20.5) 20.2 (27.1) gas, 50 Hz 13.8 (18.5) 16.8 (22.5) Cylinder head material Aluminum Valve material Steel/Stelliter Piston type and material Aluminum Alloy Crankshaft material Heat Treated, uctile Iron Governor: type Electronic Frequency regulation, no load to full load Isochronous Frequency regulation, steady state 0.5% Air cleaner type ry Engine Electrical Engine Electrical System 14RESA 20RESA Ignition system Electronic, Capacitive ischarge Starter motor rated voltage (C) 12 Battery (purchased separately): Ground Negative Volts (C) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for --18_C (0_F) 500 Group size 51 Exhaust Exhaust System 14RESA 20RESA Exhaust temperature exiting the enclosure at rated kw, dry, _C (_F) 260 (500) Lubrication Lubricating System 14RESA 20RESA Type Full Pressure Oil capacity (with filter), L (qt.) 1.8 (1.9) 1.9 (2.0) Oil filter: quantity, type 1, Cartridge Oil cooler Integral Minimum Pipe Size Recommendation, in. NPT 14RESA 20RESA Pipe Length, m (ft.) 193,000 203,000 281,000 340,000 8 (25) 3/4 3/4 1 3/4 15 (50) 1 3/4 1 1 30 (100) 1 1 1 1/4 1 46 (150) 1 1/4 1 1 1/4 1 1/4 61 (200) 1 1/4 1 1 1/4 1 1/4 Fuel Requirements Fuel System 14RESA 20RESA Fuel types or Fuel supply inlet 1/2 NPT Fuel supply pressure, kpa (in. H 2 O): gas 1.2--2.7 (5-11) LP 1.7--2.7 (7-11) Fuel Composition Limits * Nat. Methane, % by volume (minimum) 90 min. Ethane, % by volume (maximum) 4.0 max. Propane, % by volume 1.0 max. 85 min. Propene, % by volume (maximum) 0.1 max. 5.0 max. C 4 and higher, % by volume 0.3 max. 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heating value, MJ/m 3 (Btu/ft 3 ), (minimum) 33.2 (890) 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Operation Requirements Fuel Consumption Model 14RESA 20RESA Fuel Type Fuel Consumption, m 3 /hr. (cfh) % Load 60 Hz 50 Hz 100 5.4 (193) 4.9 (175) 75 4.7 (163) 4.2 (148) 50 3.5 (124) 3.1 (108) 25 2.6 (93) 2.4 (84) Exercise 1.7 (60) 1.7 (60) 100 2.3 (81) 2.1 (74) 75 2.1 (75) 1.9 (68) 50 1.8 (60) 1.5 (53) 25 1.2 (45) 1.1 (40) Exercise 0.8 (30) 0.8 (30) 100 8.0 (281) 6.4 (225) 75 6.9 (243) 5.4 (189) 50 4.6 (161) 3.9 (139) 25 3.6 (127) 2.9 (103) Exercise 2.0 (71) 2.0 (71) 100 3.9 (136) 2.9 (102) 75 3.1 (109) 2.4 (85) 50 2.3 (82) 1.8 (63) 25 1.7 (59) 1.3 (47) Exercise 1.0 (35) 1.0 (35) Nominal fuel rating: gas: 37 MJ/m 3 (1000 Btu/ft. 3 ) : 93 MJ/m 3 (2500 Btu/ft. 3 ) conversion factors: 8.58 ft. 3 =1lb. 0.535 m 3 =1kg 36.39 ft. 3 = 1 gal.

Voltage: Freq: 240 V 60.0 Hz The RC2 controller provides integrated control for the generator set, Kohlerr Model RXT transfer switch, programmable interface module (PIM), and load control module (LCM). The RC2 controller s 2-line LC screen displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RC2 Controller Features Membrane keypad: d OFF, AUTO, and RUN pushbuttons d Select and arrow buttons for access to system configuration and adjustment menus LE indicators for OFF, AUTO, and RUN modes LE indicators for utility power and generator set source availability and ATS position (Model RXT transfer switch required) LC display: d Two lines x 16 characters per line d Backlit display with adjustable contrast for excellent visibility in all lighting conditions Scrolling system status display: d Generator set status d Voltage and frequency d Engine temperature d Oil pressure d Battery voltage d Engine runtime hours ate and time displays Smart engine cooldown senses engine temperature igital isochronous governor to maintain steady-state speed at all loads igital voltage regulation: ±1.0% RMS no-load to full-load Automatic start with programmed cranking cycle Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks Exercise modes: d Unloaded weekly exercise with complete system diagnostics d Unloaded full-speed exercise d Loaded full-speed exercise (Model RXT ATS required) Front-access mini USB connector for SiteTecht or USB Utility connection Integral Ethernet connector for Kohlerr OnCuer Plus Built-in 2.5 amp battery charger Remote two-wire start/stop capability for optional connection of Model RT or RSB transfer switches RC2 Controller Additional RC2 Controller Features iagnostic messages: d isplays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load control module (LCM) d Over 70 diagnostic messages can be displayed Maintenance reminders System settings: d System voltage, frequency, and phase d Voltage adjustment d Measurement system, English or metric ATS status (Model RXT ATS required): d Source availability d ATS position (normal/utility or emergency/generator) d Source voltage and frequency ATS control (Model RXT ATS required): d Source voltage and frequency settings d Engine start time delay d Transfer time delays d Voltage calibration d Fixed pickup and dropout settings Programmable Interface Module (PIM) status displays: d Input status (active/inactive) d Output status (active/inactive) Load control module (LCM) menus: d Load status d Test function Generator Set Sound ata Model 14RESA 8 point logarithmic average sound levels are 63 db(a) during weekly engine exercise and 67 db(a) during full-speed generator diagnostics and normal operation. For comparison to competitor ratings, the lowest sound levels are 58 db(a) and 63 db(a) respectively.* Model 20RESA 8 point logarithmic average sound levels are 64 db(a) during weekly engine exercise and 69 db(a) during full-speed generator diagnostics and normal operation. For comparison to competitor ratings, the lowest point sound levels are 62 db(a) and 67 db(a) respectively.* All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation parameters.

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Battery cables EPA certified fuel system Corrosion-proof polymer sound enclosure Critical silencer Field-connection terminal block Fuel solenoid valve and secondary regulator Line circuit breaker Multi-fuel system, /natural gas, field-convertible Oil drain extension with shutoff valve Premium 5-year limited warranty 18-month limited warranty for non-standby (off-grid) applications (14RESA only) RC2 generator set/ats controller Rodent-resistant construction Sound-deadening, flame-retardant foam per UL 94, class HF-1 Available Options Approvals and Listings - CSA approval Communication Accessories - OnCuer Plus Generator Management System - OnCuer Plus Wireless Generator Management System Concrete Mounting Pads - Concrete mounting pad, 3 in. thick - Concrete mounting pad, 4 in. thick (recommended for storm-prone areas) Electrical System - Battery - Battery heater, 120VAC - Battery heater, 240VAC - Emergency stop kit - Load control module (LCM) (provides 4 power relays and 2 HVAC relays) - PowerSynct Automatic Paralleling Module (APM) (single phase only; parallels two 14RESA or two 20RESA generators) - Programmable interface module (PIM) (provides 2 digital inputs and 6 relay outputs) Available Options, Continued Fuel System - Flexible fuel line Literature - General maintenance literature kit - Overhaul literature kit - Production literature kit Maintenance - Maintenance kit (includes air filter, oil, oil filter, and spark plugs) Starting Aids - Carburetor heater, 120 VAC - Carburetor heater, 240 VAC Carburetor heater is recommended for reliable starting at temperatures below 0_C (32_F) - Fuel regulator heater pad 120VAC (20RESA) - Fuel regulator heater pad 240VAC (20RESA) Fuel regulator heater is recommended for reliable starting at temperatures below --18_C (0_F). Kohlerr Automatic Transfer Switch - Model RXT - Model RT - Model RSB - Other Kohlerr ATS Generator Set imensions and Weights Overall Size, L x W x H: 1216 x 665 x 733 mm (48 x 26.2 x 29 in.) Shipping Weight: 14RESA 191 kg (420 lb.) 20RESA 243 kg (535 lb.) L Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 H W NOTE: imensions are provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. ISTRIBUTE BY: 2011, 2012, 2013, 2014, 2015 by Kohler Co. All rights reserved.