Radiation Monitoring System DLMon



Similar documents
Radiation Monitoring System RMS

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

RADIATION MONITORING NETWORK OF THE CZECH REPUBLIC

Combi switchbox with integrated 3/2 way pilot valve

thyroid uptake systems

RADIATION PROTECTION. Alpha-Beta Particulates Monitor LB 150 D-R. ABPD Particulates Monitor combined with Alpha Energy Range Discrimination (AERD)

Application Note. ipix A Gamma imager to support various applications

RADIATION PROTECTION. Choose your application of. H ß - ɣ / ß + RAD Protect. personal dose rate meter. dose rate meter. portable.

Cronos -1 Gamma Object / Tool Monitors

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Report on heat production during preliminary tests on the Rossi Ni-H reactor.

OT 40L / 90L. Laboratory Steam Sterilizers

Pedestrian and post-luggage monitors. Vehicle monitors. Mobile monitors. Integrated monitoring system

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Tutorial 4.6 Gamma Spectrum Analysis

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Radiation Detection and Measurement

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Stack Monitor Operating Experience Review

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Introduction to Geiger Counters

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

CRIIRAD report N Analyses of atmospheric radon 222 / canisters exposed by Greenpeace in Niger (Arlit/Akokan sector)

UniOP epad33 and epad33t

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: NIS Ingenieurgesellschaft mbh lndustriestr Alzenau Germany

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Radiation Strip Thickness Measurement Systems

Dedicated computer software to radiation dose optimization for the staff performing nuclear medicine procedures

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

A Review of Emerging Gamma Detector Technologies for Airborne. Radiation Monitoring

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

Atomic and Nuclear Physics Laboratory (Physics 4780)

HEAVY WATER LEAK DETECTOR

K-Type Thermocouple Sensor User s Guide

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

RADIATION MONITORING SYSTEMS

(including ASBU RADIATION SUMMARY HISTORY WORLD INTERNATIONAL CIVIL AVIATION ORGANIZATION MET/14-IP/ /20. 4/6/14 English only

PHYA5/1. General Certificate of Education Advanced Level Examination June Unit 5 Nuclear and Thermal Physics Section A

Development of on line monitor detectors used for clinical routine in proton and ion therapy

How the People Counter Works. Enhanced Building Security and Improved Marketing Intelligence. 3D MLI Sensor Technology

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

G64 Area Gamma Monitor

Radiation-Sensor-Equipped Radio Frequency Identification System. H. Lee, J. Anderson, B. Craig, H. Tsai, Y. Liu, and J. Shuler 1

Assessment of environmental radiation monitoring data in Hungary following the Fukushima accident

Radiological mapping and characterization at the Barsebäck nuclear power plant

GAMMA-RAY SPECTRA REFERENCES

PRODUCT CATALOGUE.

Technical Information POWER PLANT CONTROLLER

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

C-10 Radiation Monitoring Network

WD-AMX Water Detection Controllers

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

RADIATION DETECTION & ANALYSIS SYSTEMS FOR WATER

Information about the T9 beam line and experimental facilities

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Q Environmental Emissions Data for Pickering Nuclear ONTARIO POWER GENERATION ONT

Principles of dosimetry The ionization chamber

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ZC-24DO CANopen I/O Module: 24 Digital Outputs

THYROID UPTAKE SYSTEMS LIST OF CONTENTS:

7.1 id Intelligent Infrastructure Management. 7.2 id Active

zamak nitrile rubber self-extinguishing technopolymer aluminum

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Quality Assurance Testing of AtomLab Dose Calibrators

Chlorophyll Content Meter. CCM-200 plus

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.

Proton tracking for medical imaging and dosimetry

Nederland België / Belgique

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

ABB i-bus EIB Logic Module LM/S 1.1

NoteLocker 8 NoteLocker 8 as a Floor-standing Solution

Metrological features of a beta absorption particulate air monitor operating with wireless communication system

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

HART HSSD High Sensitivity Smoke Detection

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Conventional Fire Detection and Extinguishant Control System Specification

-SFYLYHTC06 FOR MESSRS. :

An Innovative, portable MCA based on Digital Signal Processing. R.D. Bingham, R.M. Keyser, T.R. Twomey

Blast Vibration and Overpressure Monitor

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Strahlenschutzbelehrung Allgemeiner Teil. Radiation Protection

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Preset Counter signo 721

Radium-223 Therapy: Handling & Radiation Safety Issues


Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Antoine Henri Becquerel was born in Paris on December 15, 1852

FOR MESSRS. : WC1602A PAGE: 1/12 CONTENTS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

- 1 - BISC 367 Plant Physiology Laboratory SFU

Transcription:

Radiation Monitoring System DLMon Fields of Application: Dose rate monitoring system for use in nuclear medicine Area monitoring ( e.g. manufacturing of radionuclides, laboratories, nuclear power plants, or storage facilities of radioactive materials) Features: Custom-oriented measuring system consisting of intelligent radiation detectors and displays (up to 255 single elements). Analysis software based on advanced Client-Server-Concept (customdesigned analysis of acquired data) Address: Sensortechnik und Phone: (0)37367 / 9791 and 9792

System - Components: intelligent detector with internal micro-controller intelligent single and double displays with internal micro-controller and selectable thresholds intelligent large-scale displays with special features data acquisition and processing unit (consisting of computer, printer, nobreak power supply and RS-485 interface) Client-Server-Software ( operating system: Windows NT, 2000)

Intelligent radiation Detector: SON16 Measuring value: Photon dose equivalent rate or ambient dose equivalent rate Detector: Geiger-Muller tube Typ 70004 Measurement range: Energy range: 1 µsv/h*... 500 µsv/h * (Measurement time 200 s, Measurement uncertainty < 3 %) 35 kev... 1.3 MeV Collimator: Material: Lead Acceptance angle: ± 30 Electronics: micro-controller with internal memory 128-kByte-Flash-EPROM calculation of dose rate from counting rate correction for detector dead time and background counting rate data memory (up to 9088) values including date and time in a nonvolatile cyclic memory acquisition parameters (acquisition time, number of cycles) can be defined continuous self-monitoring of all internal and external operating voltages; functional tests of the detectors, interfaces and memories

Intelligent radiation Detector: SON20 Measuring value: Photon dose equivalent rate or ambient dose equivalent rate Detectors: Geiger-Muller tube Typ 70013E (*) Measurement range: Energy range: Collimator: 0.5 µsv/h*... 200 µsv/h * (Measurement time 200 s, Measurement uncertainty < 3 %) 35 KeV... 1.3 MeV none Electronics: micro-controller with internal memory 128-kByte-Flash-EPROM calculation of dose rate from counting rate correction for detector dead time and background counting rate data memory (up to 9088) values including date and time in a nonvolatile cyclic memory acquisition parameters (acquisition time, number of cycles) can be defined continuous self-monitoring of all internal and external operating voltages; functional tests of the detectors, interfaces and memories (*) The Type SON20 is available in versions with different GM-Tubes and several measurement ranges.

Intelligenter exhaust air monitor: AL 2000 Description: The system AL 2000 is designed for exhaust air monitoring during handling of gaseous radionuclides. Three highly-sensitive proportional counters - arranged within a 5 cm lead shielding measure the background and airborne radioactivity separately. Data acquisition and processing is computer-controlled. Dimensions (L x W x H): 560 mm x 510 mm x 630 mm Weight: Measuring values: Measuring Unit: Shielding: Functional Check: 600 kg Activity concentration Bq/m³ Detectors: Window: Volume: Lead, 5 cm external check source 3 Xe-filled proportional counters RXD 1000 1000cm², 15µm titanium foil 5 l, gas inlet and outlet with separate gas distribution chamber Electronics: micro-controller with internal memory 128-kByte-Flash-EPROM calculation of dose rate from counting rate correction for detector dead time and background counting rate data memory (up to 9088) values including date and time in a nonvolatile cyclic memory acquisition parameters (acquisition time, number of cycles) can be defined continuous self-monitoring of all internal and external operating voltages; functional tests of the detectors, interfaces and memories

Intelligent display unit: AT1 1 AT1-2 Single display for each detector or double display for two detectors, resp. Display of the measuring value: 3 1/2 - digit display (height of digits: 17.8 mm), LCD with backlighting quasi-analogue bar graph (20 elements) optical and acoustic error signalling (reset by software) 3 LED (red, yellow, green) for rapid signalling of the health risk for staff (respective thresholds can be chosen seperately for each display) EPROM for data storage Electronics: micro-controller with internal memory 128-kByte-Flash-EPROM data memory (up to 9088) values including date and time in a nonvolatile cyclic memory internal functional tests

Software Module Server-Software: Local server, automaticdataacquisation from detector and datatransfer to display Automatic monitoring of all bus components Fault-tolerant data aquisition Automatic data back-up Providing data for various clientsoftware

DLMon-client-software: Analysis software for patient monitoring for use in radioiodine therapy. Display of the arrangement of each detector in the rooms to be monitored Detector overview: display of the current dose rate digitally as well as by a colour code Dose rate histogram Long-term archiving of acquired data Detector calibration Automatic monitoring of all components and functions Marginal check: if pre-selected thresholds are exceeded - emission of warning signals and/or activation of safety facilities Patient check-in (optional: chip-card reader) Patient data base Histograms including the display of discharge-thresholds (user programmable) Data fit to estimate the effective half-life of the incorporated nuclide Transfer of patients by mouse-click Printing forms for patient discharge Drawing up reports on chosen periods

RMon-client -software: Analysis software for room monitoring for use in laboratories and exposed rooms. Display of the arrangement of each detector in the rooms to be monitored Detector overview: display of the current dose rate digitally as well as by a colour code Dose rate histograms Detector calibration Marginal check: if pre-selected thresholds are exceeded-emission of warning signals and/or activation of safety facilities