With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS



Similar documents
Centrifugal Fans and Pumps are sized to meet the maximum

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Motors and Inverters for Environmentally Friendly Industrial Equipment

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

FTQ. Daikin Inverter Ducted Heat Pump

Approach to Energy Management for Companies

Power Supply and Demand Control Technologies for Smart Cities

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

VARIABLE VOLUME / VARIABLE SPEED SYSTEMS APPLICATIONS

FTXS. Wall Mount Heat Pump or Cooling Only

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

FULL DC INVERTER SYSTEMS

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Can old buildings be just as energy-efficient as new ones?

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Frequently Asked Questions

Energy Audits Waste Water Treatment Plants

ROTARY SCREW COMPRESSOR. RMD kw

Infrastructure & Cities Sector

AORC Technical meeting 2014

Mixing Valves. ARGUS Application Note: Mixing Valves

Lesson 36 Selection Of Air Conditioning Systems

Glossary of Heating, Ventilation and Air Conditioning Terms

ENERGY SAVING BY COOPERATIVE OPERATION BETWEEN DISTRICT HEATING AND COOLING PLANT AND BUILDING HVAC SYSTEM

Printing and Publishing Energy Savings Guide

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Design Guide. Managing Peak Energy Demand In Live Performance Venues

Ship Propulsion/Electric Power Hybrid System Recovering Waste Heat of Marine Diesel Engine

New Technologies for Electric Power Distribution Systems

On-Demand Ventilation Energy Saving in Industrial Applications

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

ENERGY SAVING OF OIL HYDRAULIC PUMP UNIT BY IDLING STOP METHOD USING AN ACCUMULATOR

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL.

Delivering exceptional performance and Ecovalue. Ecocent

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

Application Guide Guardian Over the NET Server Room Solution

Sigma Control PC INSIDE. 97 psi 187 F R on load

Absorption. LG HVAC Solution.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

FINAL CONFERENCE 10 TH JUNE 2015

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

DataCenter 2020: first results for energy-optimization at existing data centers

Energy efficiency in building automation and control

Electric Coolant Pumps. Always at the Correct Temperature

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

District Cooling Plant : Refrigeration Plant Simulation

imagine SOLAR AIR CONDITIONING MADE EASY

Room thermostats wide variety and high energy efficiency

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

GSM ATT Modules Simply effective remote control

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Absolute and relative humidity Precise and comfort air-conditioning

KNX System Principles

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Optimising Energy Use in Cities through Smart Decision Support Systems

How To Save Energy On A Power Supply

Specifying a Variable Frequency Drive s

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Present Status and Future Outlook for Smart Communities

CenterMind G+ Smart and Proactive Environment Monitoring

Rainwater Harvesting

Drives and motors. A guide to using variable-speed drives and motors in car parks

Development and testing of a multi-type air conditioner without using AC inverters

Recovery of Plant Waste Heat by a Thermoelectric Generating System

High-efficient gas boiler CompactGas

FCQ. Roundflow Cassette Heat Pump or Cooling Only

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

AUTOMATIONWORX. Seamless system technology from the remote control station to the control center

HVAC System Optimization

Green IT Promotion Council, Japan

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Cost Management and Cost Reduction

HERZ-Thermal Actuators

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

AVTECH Software Inc.

Recent Technologies in Nuclear Power Plant Supervisory and Control Systems

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SCADA and Monitoring for Solar Energy Plant

Catalyst RTU Controller Study Report

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Choosing Close-Coupled IT Cooling Solutions

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Energy Saving Ideas for Your Box Plant

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Transcription:

ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS SAWAI Tsuneji *1 TAKAHASHI Hiroshi *1 INOUE Ken-ichi *2 We have developed the Econo-Pilot energy-saving system for water pumps, which reduces the power consumption of motors for water supply. In the energy-saving control field, the conventional method used is that of constant pressure control of the water supply with inverters. However, as Econo-Pilot employs a method of variable water pressure control corresponding to flow volume, the system can raise the energy-saving ratio up to 90 percent. This paper describes the principles of the system and its basic functions, along with a case study of some practical applications. INTRODUCTION With the background of fulfilling public commitments for the prevention of global warming, many countries have consolidated related laws and regulations aiming to reduce energy consumption. Energy conservation has become one of the important issues for companies and organizations accredited with the ISO 14000 series standards certification because they are required to achieve yearly targets for improvements, which have, in a sense, the same implications as laws. In a prolonged recession, investments in energy-saving activities directly linked with cost reduction have attracted increasing attention. However, large-scale renewal investments which entail enormous costs cannot be implemented easily. Consequently, there have been increasing needs for energy conservation activities which bring about substantial cost reduction effects but can be conducted inexpensively with ease and minimum risks, while at the same time utilizing existing facilities. Figure 1 is a graphical indication of the energy consumption ratios of office buildings, which is based on research conducted by the Building-Energy Manager s Association of Japan. As indicated in the graph, air conditioning-related items account for *1 Industrial Solutions Business Headquarters *2 Industrial Automation Systems Business Division half of the total consumption. This means that air conditioning must be the main target for energy conservation. Among air conditioning-related technologies, we have focused on the control of air conditioning pumps and have developed a new energy-saving control system called Econo- Pilot which meets the requirements for implementations mentioned earlier. Figure 2 shows an external view of this system. The Econo-Pilot adopts a new control mechanism contrived by three enterprises Yokogawa Electric Corporation, Asahi Kogyosha Co., Ltd., and The First Energy Service Company, Others (electric outlets, sanitation, transportation, etc.) Lighting 25% 30% 25% Air conditioning ventilation 13% 7% s for air conditioning Air conditioning pumps Figure 1 Energy Consumption of Office Buildings by Usage Econo-Pilot Energy-saving System for Water Pumps 5

Constant pressure control is applied also to prevent excessive pressure. To be closed when room temperature reaches a preset value. Flow volumes vary Return valve for maintaining constant pressure Secondary pump for supplying water to air conditioners Supply water of constant temperature all the time Secondary pump Controller Return valve Return valve for maintaining constant pressure Primary pump The number of secondary pumps and the number of heat sources are controlled according to flow volumes. Flow volume Figure 2 External View of the Econo-Pilot Figure 4 Typical Air Conditioning System Limited and was commercialized by Yokogawa after the development and demonstration phases, through joint research with the New Energy and Industrial Technical Development Organization (NEDO). OVERVIEW OF AN AIR CONDITIONING SYSTEM Figure 3 shows an overview of an air conditioning system. Broadly speaking, energy is consumed by heat sources, water pumps, and ventilators. A heat source generates cold/hot water through gas combustion in the case of applying a gas-based cold/hot water generator, the cold/hot water is then conveyed to air conditioners by water pumps. Inside air conditioner, the cold/hot water is flowing through heat exchange equipment where air is warmed up or cooled when passing through the heat exchange equipment via ventilators, and then the warmed/cooled air is blown to an area through ducts. Water pumps are mainly classified into primary pumps, secondary pumps, and cooling pumps, but their power consumption is almost the same. Among them, we have focused on secondary water pumps whose flow volume varies significantly according to demand. Figure 4 shows the configuration of a typical air conditioning system, which indicates the flow direction of cold/hot water by using arrows. Cold/hot water generated in heat sources is returned by primary pumps so that water at constant temperature is always available. Secondary water pumps are responsible for conveying the cold/hot water upon demand of the air conditioners on the load side. Cold/hot water Flow volume Water pumps Primary pump for air conditioning Secondary pump for air conditioning Pump for cooling water Secondary pump Escape valve Conventional controller FCJ Inverter Primary pump Ventilator Figure 3 Overview of an Air Conditioning System Figure 5 Configuration of an Air Conditioning System Using the Econo-Pilot 6 Yokogawa Technical Report English Edition, No. 36 (2003)

Constant pressure Constant pressure Flow volume 100% pressure Flow volume 50% pressure 25 50 100 25 50 100 Flow volume 25% 25 50 100 Flow volume (%) Flow volume (%) pressure Flow volume (%) (a) Conventional return valve method (constant discharge pressure control) (b) Conventional inverter method (constant discharge pressure control) (c) Econo-Pilot Method (predictive control of conduit resistance characteristics) Figure 6 Comparison between a Conventional Control Mechanism and the Econo-Pilot Mechanism s are controlled locally on each floor or in each area by room temperature sensors and two-way valves. These valves are closed automatically when the room temperature reaches a preset value. As a result, the flow volume of cold/hot water running on the secondary pump side varies significantly. In order to support the flow volume fluctuations efficiently, multiple secondary water pumps are frequently used: for example, two or three pumps are operated to control the turning on/off of each pump according to flow volume changes. Moreover, in order to protect the pipes and air conditioners, return valves are used for control so that constant pressure will be applied to the pipes. However, these return valves play another role of bringing the pumped water back to the original locations, which is essentially a waste of power. Recently, with the prices of inverters becoming less and less expensive, an energy-saving technique of increasing or decreasing the number of revolutions of water pumps to supply only the necessary amount of water has become increasingly common. However, since these inverters employ a control mechanism to maintain constant pressure as in the case of return values, they do not, in actuality, bring about substantial energy conservation effects. CONFIGURATION AND ENERGY-SAVING PRINCIPLES OF AN AIR CONDITIONING SYSTEM BASED ON THE ECONO-PILOT Configuration Figure 5 exemplifies the configuration of an air conditioning system based on the Econo-Pilot. The Econo-Pilot can be easily introduced if a compact site-based STARDOM FCJ controller is added to an existing air conditioning system. More specifically, sensor signals that have been used in the existing control system are branched out and are connected to the STARDOM FCJ. Outputs for directing the number of revolutions are connected to inverters by way of a switch. Since this configuration enables the existing control system to remain as it used to be, focusing on the energy conservation of water pumps, complicated work such as the readjustment of existing control system is never required. Energy-Saving Principles The conventional inverter method employs a constant discharge pressure control mechanism. On the other hand, the Econo-Pilot has achieved energy-saving by optimizing the discharge pressure control while taking account of pressure loss in pipes. Relationships between the number of revolutions of a water pump and its power are described here. Theoretical characteristics of the pump are as follows: (1) Flow volumes are proportional to the number of revolutions. (2) Discharge pressure (pump head) is proportional to the square of the number of revolutions. (3) Power consumption is proportional to the cube of the number of revolutions. That is, if a flow volume is 1/2, pressure becomes 1/4 and power consumption becomes 1/8, thereby providing a power reduction ratio of 87.5 percent. Figure 6 shows the differences between a conventional control mechanism and the Econo-Pilot mechanism. The horizontal axis shows flow volumes, while the vertical axis shows pump heads (discharge pressures). Solid curved lines show pump head curves (performance curves). The greater a flow volume is selected, the smaller a pump head becomes. On the other hand, the greater the pump head is selected, the smaller the flow volume becomes. Broken lines show conduit resistance curves when the entire secondary pump system is viewed macroscopically. It is construed that if the flow volume increases, conduit resistance also increases in proportion to the square of the flow volume. Differences in control operations among (a), (b), and (c) are described below: (a) Conventional return valve method (constant discharge pressure control) Econo-Pilot Energy-saving System for Water Pumps 7

Compact and autonomous controller FCJ that is ideal for installation at sites Site monitoring and adjustment Example of a window Remote monitoring and adjustment Escape valve (emergency use) meter Public telephone line (via modems) or intranet (Ethernet) General-purpose PC (web browser) Flow volume Inverter Control of pressure (number of revolutions) according to flow volumes Figure 7 Remote Monitoring and Adjustment System of the Econo-Pilot The intersection point between the horizontal line showing the constant pressure and the head curve is the operation point. Since a return valve provides pressure control, the pump s operation point is always the same regardless of load situations, while power consumption also remains the same. (b) Conventional inverter method (constant control of discharge pressures) At present, this method is the commonly used energy-saving technique for secondary water pumps. Since constant pressure control is adopted, the operation point moves on the linear constant pressure line. The number of revolutions cannot be decreased substantially, because pressure needs to be maintained even if the flow volume is small. Consequently, the power reduction ratio is usually in the degree of 20 to 30 percent. (c) Econo-Pilot method (predicted control of pipe resistance characteristics) This method is employed for the Econo-Pilot. Since the method allows the operation point to move on the conduit resistance curve, the graph shows that energy-saving effects increase dramatically if the flow volume is small. CONFIGURATION OF A REMOTE MONITORING SYSTEM Figure 7 shows an example of system configurations. The compact STARDOM FCJ controller that can be installed at sites provides not only a control function superior to PLC, but also an information processing function equivalent to the one of PCs. This controller is connected to an indicator for site operation monitoring that is used to monitor energy-saving operations or change settings. The indicator also enables real-time monitoring of power reduction ratios or monthly energy consumption/ reduction status. Logging and monitoring of energy-saving effects (i.e., power consumption ratios) further enable users to optimize operational conditions for energy conservation or to check returns on investments. Moreover, the Econo-Pilot allows users to operate and monitor windows showing the same information through web browsers, thereby enabling the energy monitoring and adjustment in anytime and at anywhere. One of the advantages of adopting web browsers is that users can adjust their systems remotely. For example, users can initially carry out rough adjustments at sites. Then, remotely, they can perform gradual adjustments to enhance energy-saving effects while checking the operational conditions. If any changes occur on the load side for example a dramatic increase in personnel users can remotely access their sites to obtain detailed information and provide optimized readjustments. Thus, enhanced energy-saving effects can now be obtained without risks. ECONO-PILOT S SCOPE OF APPLICATION AND VERIFICATION OF EFFECTS The Econo-Pilot is ideal for energy conservation of factories or ordinary buildings, especially for already installed secondary pump facilities. It can also be applied to water pumps in general which provide not only air conditioning but also pressure control. One of the most effective applications is realized during long-term operation. The longer operation hours become, the greater energy is saved even for the equipments of the same scale. For example, on a yearly basis facilities such as semiconductorrelated factories, hospitals, or hotels operating continuously for 24 hours a day generate reduction effects which are several times greater than those of office buildings. Moreover, if the scale of a facility (i.e., power consumption of pumps) is larger, greater 8 Yokogawa Technical Report English Edition, No. 36 (2003)

financial gains can be obtained even from the same reduction ratio. This control system has actually been introduced to a university hospital, the details of which are described below. This case shows that greater reduction effects were obtained in comparison with that using a conventional inverter s constant pressure control. Type of industry: university hospital (about 1,200 beds) Area of air conditioning to be controlled: 5,000 m 2 Target facility: One secondary pump using cold/hot water, 37 kw Reduction effects: 186 MWh/year, 71.4 tons of CO2/year Energy reduction ratio: 67% Payback period of investment: 1.9 years CONCLUSION This paper focused on a case study in which a secondary water pump for air conditioning used our energy-saving control system, which can be inexpensively installed with ease while utilizing existing facilities. Environmental investments including energy-savings can be implemented only when they are compatible with economic efficiency, from which substantial environmental improvements can be expected. We intend to support cost reductions at offices, factories, and other locations by broadening the scope of this system to equipment other than secondary water pumps for air conditioning, thereby contributing to further reductions of global warming gases. ACKNOWLEDGMENTS We would like to express our appreciation to all parties involved in the research and development of this product, which was achieved through joint research with the New Energy and Industrial Technology Development Organization (NEDO) under a project entitled Development of Optimum Control Technologies for Reduction of Operational Electric Losses. REFERENCES (1) Ishizuka Hitoshi, Overview of the Development of Optimum Control Technologies for Reduction of Operational Electric Losses, SICE System Integration Department Lecture, SY0014/02/0002-0309, December 2002, p. 309 (2) Yokogawa Electric Corporation, Electric Power Reduction by Optimum Control of Heat Sources for Air Conditioning, Research Report, NEDO, 2002 (3) General Management Methodologies for Energy-Savings at Buildings, Building-Energy Manager s Association of Japan, 2000, p. 35 * Econo-Pilot is a trademark of Yokogawa Electric Corporation. The Econo-Pilot received the Agency of Natural Resources and Energy Director-Genera s Award for fiscal year 2002. Econo-Pilot Energy-saving System for Water Pumps 9