ETZGAR CONVEYOR COMPANY Controls Section v12.05



Similar documents
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Glossary of Common Crane Ter ms:

OPERATING INSTRUCTIONS

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Oil and Coolant Circulating Heating System. Model - OCSM

Introduction to Process Control Actuators

HM-W536 Install Guide

PUSH BUTTON START INSTALLATION MANUAL

Comparison of NEMA and IEC schematic diagrams

Specifying a Variable Frequency Drive s

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

EET272 Worksheet Week 8

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

IMPORTANT SAFETY RULES TO FOLLOW

3BASIC RELAY INSTRUCTIONS

Section 1: Safety. General Safety. Recognizing Safety Precautions. Locking Out the Machine. Safety Circuits. Interpreting the Light Column

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

EDI Distributor Control Interface Wiring and Setup Instructions

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15


INSTALLATION INSTRUCTIONS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Single Phase Soft Starter

MCC Ratings. Voltage Rating

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Model 2300DR Installation Guide

Electro-Pneumatic Bus Door Control Mechanism

OPL BASIC. Dosing System for Professional Laundry machines. Contents

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

e-ask electronic Access Security Keyless-entry

MODEL HSR-007 Direct Drive Rolling Steel

MIC-WKT and MIC-WKT-IR

Technical Information

Thyristor-controlled power supplies and battery chargers

SECTION LOW VOLTAGE LIGHTING CONTROLS

Unit 24: Applications of Pneumatics and Hydraulics

Diesel Engine Driven Generators Page 1 of 6

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

THE INPUT/OUTPUT SYSTEM. Key Points

Electrical Symbols and Line Diagrams

SECTION VARIABLE FREQUENCY DRIVES

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Operating Instructions. UL325 Compliant Non-monitored

Vilter motor starter solutions The NEW industry standard in motor starter packages

Electronic, Digital and Mechanical Vibration Switches

GLOLAB Two Wire Stepper Motor Positioner

Centro-Matic Automatic Lubrication Systems System Controls

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Cable/Conduit Conversion

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Series Hose Reels

P70, P72, and P170 Series Controls for Dual Pressure Applications

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e.

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

DC Motor control Reversing

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

BERMAD Fire Protection

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Pentalift Equipment Corporation Lift table and positioning equipment glossary of terms

*.ppt 11/2/ :48 PM 1

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Low Voltage Fuses For Motor Protection

Instructions & Safety Information Models A220-20D and A220-20L Version 2

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Programming Logic controllers

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Compressor Service & Maintenance Manual

PC1131 Electric Air Compressor

ABR Brake Rectifier Instruction Manual

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Fig 3. PLC Relay Output

Reverse Cycle Inverter Split System Air Conditioner

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

How to read this guide

Bolted contact switches. Pringle switches

Transcription:

Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed Packages 7-6 AC vs DC Variable Speed Application Information 7-7 DC Variable Speed Packages and Accessories 7-1 Metzgar Conveyor Co. 2012

Motor Data Table 1- Estimated Full Load Amps of Motors Horsepower 110v Single φ 220v Single φ 208v Three φ 230v Three φ 460v Three φ 1/3 5.8 2.9 1.4 1.3 0.65 ½ 8.8 4.4 2.0 1.8 0.9 1 10.8 5.4 3.0 2.8 1.4 1 ½ 17.2 8.6 5.2 5.0 2.5 2 20.0 10.0 6.5 6.2 3.1 Industry Standard Enclosure Ratings: NEMA1 Enclosures rated for indoor use primarily to provide a degree of protection against contact with the equipment in the enclosure. NEMA4 Enclosures rated for indoor use primarily to provide a degree of protection against wind blown dust and rain, splashing water and hose directed water. NEMA12 Enclosures rated for indoor use primarily to provide a degree of protection against dust, falling dirt, dripping non-corrosive liquids. NEMA13 Enclosures rated for indoor use primarily to provide a degree of protection against dust, spraying water, oil and non-corrosive coolant. Controls Glossary: Control Panel A control enclosure that could contain motor starters, relays, fuses, Control transformers, programmable logic controllers and terminal Control Station - A Control Enclosure containing pushbuttons. Control Transformer A device used to convert high voltage to a lower level where it is used to power pushbuttons, photoeyes, motor starters and solenoids. Emergency Stop A device that stops the equipment in the event of an emergency. Common types include pushbuttons and pull cord switches. Magnetic Starter A electromechanical device which when activated applies power to motors. Motor Safety Switch A lockout device that inhibits a motor from being run when maintenance personnel are working on the conveyor. Overload Relay A device that detects if a motor is drawing too much current and stops the motor before damage occurs. PC Personal Computer PLC Programmable Logic Controller Solenoid Valve 3-way An electrically operated pneumatic valve commonly used to operate brakes on line shaft conveyor. Solenoid Valve 4-way An electrically operated pneumatic valve commonly used to operate transfers and pop-up stops with double acting cylinders. Variable Speed DC (Direct Current) An operator can vary the speed of the conveyor with a DC motor and DC SCR speed controller. Power Source required 110vac or 220vac single phase. Variable Speed AC (Alternating Current) An operator can vary the speed of the conveyor with a three phase AC motor and AC variable frequency drive speed controller. 7-2 Metzgar Conveyor Co. 2012

Controls Safety Guidelines: This section is provided to give you basic conveyor safety guidelines in addition to giving information on which controls accessories should be used in a particular application. For Safety considerations and applications not listed below consult the factory or a qualified source (OSHA, state or Local codes) to determine the safety requirements for your application. Lockout Safety Switches or Disconnect Switches: All control cabinets and motors should be provided with a safety switch. These completely remove the power from the conveyor. These switches have provisions for locking in the off position for any personnel working on the conveyor. Start-up Warning Horns: All conveyors should be within sight of the operator pushing the start pushbutton. If the operator cannot see the entire conveyor being started some type of audible device is required. The time delay would allow personnel to activate a emergency stop or become clear before motion begins. Emergency Stops: At each location where operators are working at or on the conveyor, an emergency stop should be located. An operator working directly at the conveyor should not be required to move to actuate an emergency stop. If several operators are working along the conveyor a cable operated switch is the most cost effective means for providing an emergency stop. Manual reset of the emergency stop that was activated is required before the system can be restarted. For instances which the operators are not working at or on the conveyor, stop buttons should be provided so an operator can stop the system without having to cross any obstructions. In this instance the stop would be used to protect the equipment from damage rather than personal safety. Air Pressure Actuated Switches: Air pressure switches should be used on systems using air operated devices. The conveyor should stop rather than cause damage to personnel or product. Controls Logic and Start Circuits: Start-up circuits and emergency stop circuits should be configured using control relays and hardwired devices. Foot Switches: Foot Switches can be dangerous operator controls when not applied correctly. A footswitch should be used in a application when accidental actuation will not cause harm to the operator. Safety Codes: State and Local codes may require additional safety devices not covered in this section. Consult your local or state OSHA office for additional information. METZGAR CONVEYOR COMPANY ASSUMES NO LIABILITY TO THE INCLUSION OF ALL FEDERAL, STATE, LOCAL OR PLANT SAFETY DEPARTMENT REQUIREMENTS. IF METZGAR CONVEYOR IS MADE AWARE OF SUCH REQUIREMENTS AT THE TIME OF BID, WE WILL INCORPORATE THEM AS PART OF OUR PROPOSAL. 7-3 Metzgar Conveyor Co. 2012

Controls Packages Fixed Speed: Non-UL Non-Reversing Package Model Number: E605 - N - 460 3 E6 Controls and Motor HP * Non-Reversing Package Voltage(110, 220, 208, 230 or 460) 1=Single phase, 3=Three Phase Non-Reversing Equipment List: (1)- Control Enclosure 1- Disconnect Switch 1- IEC Style Magnetic Motor Starter 1- IEC Style Overload Relay 1- Control Transformer ( 3 Phase Only) 1- Start Conveyor Pushbutton 1- Stop Conveyor Pushbutton (1)- Standard Enclosure Mounting Bracket Non-UL Reversing Package Model Number: E605 - R - 460 3 E6 Controls and Motor HP * Reversing Package Voltage(110, 220, 208, 230 or 460) 1=Single phase, 3=Three Phase Reversing Equipment List: (1)- Control Enclosure 1- Disconnect Switch 1- IEC Style Reversing Magnetic Motor Starter 1- IEC Style Overload Relay 1- Control Transformer ( 3 Phase Only) (1)- Standard Enclosure Mounting Bracket (2)- Forward/Reverse/Stop Control Stations * Motor Sizes ½ = 05, ¾ =75, 1=10, 1 ½ = 15 and 2=20 Refer to Controls safety guidelines for your application to determine if any additional accessories are required. All controls packages are shipped loose unless factory prewiring is purchased. Consult factory if specific brands or parts are required. 7-4 Metzgar Conveyor Co. 2012

Controls Packages AC Three Phase Variable Speed: Non-UL Non-Reversing Package Model Number: E605 - N - 460-3VS E6 Controls and Motor HP * Non-Reversing Package Voltage(110, 220, 208, 230 or 460) 1=Single phase, 3=Three Phase Three Phase Variable Speed Non-Reversing Equipment List: (1)- Control Enclosure 1- Disconnect Switch 1- AC Variable Frequency Drive 1- Control Transformer 1- Door mounted Speed control knob 1- Start Conveyor Pushbutton 1- Stop Conveyor Pushbutton (1)- Standard Enclosure Mounting Bracket Non-UL Reversing Package Model Number: E605 - R - 460-3VS E6 Controls and Motor HP * Reversing Package Voltage(110, 220, 208, 230 or 460) 1=Single phase, 3=Three Phase Three Phase Variable Speed Reversing Equipment List: (1)- Control Enclosure 1- Disconnect Switch 1- AC Variable Frequency Drive 1- Control Transformer 1- Door mounted Speed control knob (1)- Standard Enclosure Mounting Bracket (2)- Forward/Reverse/Stop Control Stations * Motor Sizes ½ = 05, ¾ =75, 1=10, 1 ½ = 15 and 2=20 Refer to Controls safety guidelines for your application to determine if any additional accessories are required. All controls packages are shipped loose unless factory prewiring is purchased. 7-5 Metzgar Conveyor Co. 2012

Consult factory if specific brands or parts are required. Order Separately: Inverter Duty Motor 7-6 Metzgar Conveyor Co. 2012

AC vs DC Variable Speed Application Information: DC Variable Speed: Power Requirements: 110 or 220 volts Single Phase. Motor:90 volt DC Motor for 110v input, 180 volt DC Motor for 220v input. Speed Controller: DC SCR Speed Controller Advantages: Disadvantages: -Low Cost - Motor cost above 1 hp increases significantly. -Constant Torque - Motors have brushes that eventually will wear out. -Allows for slow speeds -Plug into wall power -Easy to make portable Table-1 DC Speed Chart Speed of Minimum Conveyor Speed Drive FPM FPM Maximum Speed FPM 20 2 20 30 3 30 40 4 40 50 5 50 60 6 60 70 7 70 80 8 80 90 9 90 100 10 100 AC Variable Speed: Power Requirements: Three Phase (Special Drives can use Single phase for small motors). Motor: AC three Phase Motor Speed Controller: AC Drive also Referred to as an Inverter Advantages: Disadvantages: - Uses Common Three Phase Motor -Three Phase Power Required - Allows for Over Speeding of the Motor -Higher Initial Cost - Is More Energy Efficient Table-1 AC Speed Chart Speed of Minimum Conveyor Speed Drive FPM FPM Maximum Speed FPM 20 7 30 30 10 45 40 14 60 50 17 75 60 20 90 70 24 105 80 27 120 90 30 135 100 33 150 7-7 Metzgar Conveyor Co. 2012

* Conveyor Speeds over 100FPM require Special Mechanical Components 7-8 Metzgar Conveyor Co. 2012

Controls Packages DC Variable Speed: DC Variable Speed (Requires 110 vac Power) E6DC-09005 ½ HP DC Adder Includes 3 Phase to 90 VDC motor upgrade and SCR controller E6DC-09075 ¾ HP DC Adder Includes 3 Phase to 90 VDC motor upgrade and SCR controller E6DC-09010 1 HP DC Adder Includes 3 Phase to 90 VDC motor upgrade and SCR controller Controls Accessories: Pull Cord E6ES-000001 E6CK-000025 E6CK-000050 E6CK-000100 E6CK-000150 Control Stations E6CS-ES0001 E6CS-SS0001 E6CS-FRS001 E6CS-UDS001 Safety Switch E6SW-NF0100 Emergency Stop Pull Cord Switch and Mounting Bracket 25 Red Plastic Coated Cable and Mounting Hardware 50 Red Plastic Coated Cable and Mounting Hardware 100 Red Plastic Coated Cable and Mounting Hardware 150 Red Plastic Coated Cable and Mounting Hardware Emergency Stop Pushbutton Control station Start-Stop Pushbutton Control Station Forward-Reverse-Stop Pushbutton Control Station Up-Down-Stop Pushbutton Control Station Non-Fused Motor Safety Switch with Mounting Bracket Controls Prewiring: E6PW-K003PH Wiring Three Phase Package to the Motor E6PW-K003PH Wiring Three Phase Package to the Motor E6PW-K001PH Wiring Single Phase Package to the Motor E6PW-K001PH Wiring Single Phase Package to the Motor E6PW-K001DC Wiring DC SCR Speed Controller to the Motor and 15 cord and Plug 7-9 Metzgar Conveyor Co. 2012

Notes: 7-10 Metzgar Conveyor Co. 2012