sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved



Similar documents
Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

Simple Self-Diagnosis by Malfunction Code

PANASONIC TROUBLE SHOOTING GUIDE

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

INSTALLATION MANUAL. Address card EKAC10B

, User s Manual

14. Troubleshooting Guide

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

IntesisBox Modbus Server SAMSUNG Air Conditioners

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Failure code manual. content

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)


Modbus Server SAMSUNG Air Conditioners

Split and Multi Split air conditioners Service information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

IntesisBox KNX Mitsubishi Heavy Industries AC

Diagnostic Fault Codes For Cummins Engines

1 Application Description Objective Goals... 3

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

HEATER, AIR CONDITIONING AND VENTILATION

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

KNX Panasonic Air Conditioners

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

IntesisBox KNX LG Air Conditioning

Variable Air Volume - VAV

T5000 T000 LCD Digital Fan Coil Thermostat

Designed for multi-injector endurance testing, the

Technical service manual

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

USER S MANUAL HSC-24A

Technical Information

Technical service manual 2009

SMM. Installation Operation Maintenance

Application Engineering

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Impact of Control System Technologies on Industrial Energy Savings

Instruction manual for Firstline FCS12000CH

Air conditioning, electrical testing

Midea Commercial Air Conditioner Malfunction Handbook

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

REMOTE CONTROL MANUAL

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Oil and Coolant Circulating Heating System. Model - OCSM

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

CONTINUOUSLY VARIABLE TRANSMISSION (CVT)

Table of Contents. 1 - Specifications Installation Wiring User controls...7

PROCEDURES FOR SELF DIAGNOSTICS

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

MP-4000 Alarm List (Software version or later)

Aerona Air Source Heat Pumps

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

SERVICE MANUAL INDOOR UNIT

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Workshop 7 PC Software - Tracker

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

NC-12 Modbus Application

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

MANUAL PC1000R

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

INSTALLATION OPERATING & MAINTENANCE MANUAL

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V

ECOCIAT. Domestic hot water heat recovery unit

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

IQAN MDM Operation Manual

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

B/S/H/ Error codes and service programmes PH

HVAC Processes. Lecture 7

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

SERVICE MANUAL REFRIGERATION

Fault Code Check List

REGTRONIC OPERATING INSTRUCTIONS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

WINDOW ROOM AIR CONDITIONER

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

HEAT SIPHON ANSWERBOOK

A/C-HEATER SYSTEM - AUTOMATIC

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

Appendix - Controllers 179

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Transcription:

Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009

Section : Configuration Connect power supply to SIP and power up The default connection for the Sanyo AMY is via Serial Port # on the SIP Connect to laptop/pc via Ethernet port for configuration Fixed IP address is 9.68..6 To configure the Sanyo serial port: - Select the Baudrate - default 9600 - Select Port No and click SEND & REBOOT to save changes To configure the Modbus serial port: - Select the Baudrate - default 9600 - Select the Port type - default RS - Select Port No and click SEND & REBOOT to save changes NB: Sanyo Software for the AMY uses a Baudrate of 9600. The AMY may be set to 900 (default), therefore either the the AMY or the SIP has to be changed. The rest of the serial port settings are 8-databits, no parity, one stop bit.

Section : SIP/AMY 6 MODBUS TABLE PROHIBITS 0 - ON/OFF MODE SETPOINT FLAP FAN SPEED NOT USED TEMP READING FLAP 6 SWING Unit FAN SPEED 0 AUTO MANUAL HIGH MANUAL MEDIUM MANUAL LOW MODE 6 7 HEAT COOL FAN DAY AUTO - AUTO COOL - AUTO HEAT 6 SETPOINT 7 FILTER SIGN 8 ALARM CODE 9 ON/OFF Unit 0-8 Read Only Unit 6 Temperatures need 0. scaling Mode has to read from FUNCTION and change via FUNCTION AMY read/write values go via FUNCTION Read only values are not available in FUNCTION All other points are available as Read Only on FUNCTION Modbus slave address is calculated from the AMY adaptor number by adding to the adaptor number. In each AMY there are adaptors, per link. Each link is a Modbus slave containing up to 6 units.

Section : Technical Specification 6 (0.) V- V+ 9-0Vdc (0.6). (0.9) Reset Button 0 (.09) sip (0.98) P P P P P P6 P7 P8 7 (0.8) Serial Ports Power Supply 8 (6.) 70 (6.69) 80 (7.08)

Section : Pinouts, Cable Connections & Wiring SIP Cable Connections SIP to AMY SIP (RJ) AMY (Screw) A Data + A B Data - B 0 Screen SIP to Modbus (RS8) SIP (RJ) A Data + Screen B Data SIP to Modbus (RS) SIP (RJ) Ground TX RX Wiring Default AMY(RS8) RJ RS DATA + DATA - RS8 Selectable from Configuration Page P Default Modbus(RS)

Section : Alarm Fault Codes Numeric Code Sanyo Code 6 7 8 0 6 7 8 9 0 6 7 0 6 7 8 8 9 0 6 7 8 6 6 66 A0 A0 A0 A0 A0 A06 A07 A08 A0 A A A A A A6 A7 A8 A9 A0 A A A A A A6 A7 A0 C0 C0 C0 C0 C0 C06 C C6 C7 C8 C9 C C C C C C6 C E0 E0 Engine oil pressure abnormality. Engine oil abnormality. Engine over-revving abnormality. Engine low revs abnormality. Ignition power abnormality. Engine start failure. Fuel gas valve abnormality. Stalling. High exhaust gas temperature. Engine oil level abnormality. Throttle (step motor) abnormality. Fuel gas regulating valve abnormality. Engine oil pressure switch abnormality. Short-circuit in starter power source output. Starter lock. CT abnormality (defective starter current detection). Cooling water pump current abnormality. Three-way wax valve abnormality. High cooling water temperature. Cooling water level abnormality. Overload of cooling water pump. Crank angle sensor abnormality. Cam angle sensor abnormality. Clutch abnormality. Accidental fires. Catalyzer temperature abnormality. Low fuel gas pressure abnormality. Poor setting on Control Address (duplicated). Discord of number of units in central process control. Miswiring of central process control. Misconnection of central process control. Transmission error of central process control. Reception error of central process control. Lump alarm by local adapter. Poor transmission of the adapter to the unit. Poor reception of the adapter from the unit. Duplicated control addresses in the adapter. Duplication of adapter addresses. Non-volatile memory in the adapter is abnormal. Poor setting of adapter address. Faulty host terminal (software). Faulty host terminal (hardware). Abnormal processing of the host terminal. Communication error in the host terminal. Change of constitution (the adapter detects the change). Poor reception of the signal on the remote controller. Poor transmission of the signal on the remote controller. 67 E0 Poor reception of the indoor unit from the remote controller(central process control). 68 69 70 7 7 7 E0 E0 E06 E07 E08 E09 Poor reception of the indoor unit from the outdoor unit. Poor transmission of the indoor unit to the outdoor unit. Poor reception of the outdoor unit from the indoor unit. Poor transmission of the outdoor unit to the indoor unit. Duplicated setting of indoor unit?s address. Setting multiple master remote controllers. Description

Section : Alarm Fault Codes Numeric Code Sanyo Code 7 76 77 78 79 80 8 8 87 88 89 90 9 9 9 9 97 98 99 00 0 0 0 0 0 E E E E E E6 E7 E8 E E E E6 E7 E8 E9 E0 F0 F0 F0 F0 F0 F06 F07 F08 F09 Poor reception of the indoor unit from the signal output P.C.B.. (CR-WAY TG) No auto address setting. (Auto address is in setting) Poor transmission of indoor unit to the remote controller. Duplicated address of master indoor unit in group processing control. Alarm for auto address setting.(number of indoor units is too small.) Alarm for auto address setting.(number of indoor units is too large.) Poor transmission from outdoor unit to indoor unit. Poor communication of group processing control caused by miswiring. Poor transmission of CCU to outdoor sub bus. Poor reception of CCU from outdoor sub bus. Poor setting of outdoor sub bus address. (duplicated) Discord of number of outdoor sub bus units. Miswiring of outdoor sub bus. Misconnection of outdoor units. Poor reception of outdoor serial. Poor transmission of outdoor serial. Abnormal sensor for the inlet temp. on the heat exchanger of the indoor unit. Abnormal sensor for mid-point temp. on the heat exchanger of the indoor unit. Abnormal sensor for the outlet temp. on the heat exchanger of the indoor unit. Abnormal sensor for the outlet temperature of the PC compressor. Abnormal sensor for the outlet temperature of the AC compressor. Abnormal sensor for the inlet temp. on the heat exchanger of the outdoor unit. Abnormal sensor for the outlet temp. on the heat exchanger of the outdoor unit. Abnormal sensor for outdoor temperature. Actuation of scroll compressor protective thermostat. 06 F0 Abnormal sensor for suction temperature of indoor unit. 07 08 0 7 8 9 0 6 7 9 0 F F F F6 F8 F9 F F F F F F6 F7 F8 F9 F0 F H0 H0 H0 H0 H0 Abnormal sensor for discharge temperature of indoor unit. Abnormal sensor for cooling water temperature. Abnormal sensor for engine room temperature. Abnormal sensor for suction and discharge gas. Abnormal sensor for exhaust gas temperature. Abnormal sensor for compressor bottom temperature. Abnormal sensor for compressor current. Abnormal sensor for discharge gas temperature from compressor. Abnormal sensor for refrigerant gas temperature in the heat exchanger. Abnormal sensor for liquid refrigerant temperature in the heat exchanger. Abnormal sensor for heat exchanger coil temperature. Abnormal sensor for heat exchanger coil temperature. Abnormal sensor for compressor current. Abnormal sensor for compressor current. Abnormal non-volatile memory (EEPROM) in indoor unit. Abnormal timer (RTC). Abnormal non-volatile memory (EEPROM) in outdoor unit. Incorrect current value for compressor.(over current) Incorrect current value for compressor.(locked compressor) CT sensor is dislocated from compressor - Short circuited. Protective thermostat for scroll compressor. Protective thermostat for scroll compressor is slipped off. 6 7 8 9 H06 H07 H08 H09 H0 H Activation of low pressure switch. No oil in compressor. Incorrect connection of oil sensor. Chattering of magnet switch.(multi) Defective sensor for crank case heater. Incorrect current value for compressor.(over current) Description

Section : Alarm Fault Codes Numeric Code Sanyo Code 0 H Incorrect current value for compressor.(locked compressor) H CT sensor is dislocated from compressor - Short circuited. H Protective thermostat for scroll compressor. H Protective thermostat for scroll compressor is dislocated. H6 No oil in compressor. H7 Sensed unbalanced power voltage. 6 H8 Chattering of magnet switch (Espacio). 7 H9 Chattering of magnet switch. 8 H0 Defective sensor for crank case heater. 9 H Incorrect current value for compressor.(over current) 0 H Incorrect current value for compressor.(locked compressor) H CT sensor is dislocated from compressor - Short circuited. H Protective thermostat for scroll compressor. H Protective thermostat for scroll compressor is slipped off. H6 No oil in compressor. H7 Incorrect connection of oil sensor. 6 H8 Incorrect connection of oil sensor. 7 H9 Chattering of magnet switch. 8 H0 Defective sensor for crank case heater. 9 L0 Incorrect address for indoor unit. (No master indoor unit.) 9 L0 Mismatch of indoor and outdoor units. 9 L0 Setting plural master indoor units for group control. 96 L0 Duplicate setting of system address (outdoor unit). 97 L0 Duplicate setting of priority indoor unit. (for priority indoor unit) 98 L06 Duplicate setting of priority indoor unit. (for other than priority indoor unit.) 99 L07 Group control wiring to individually controlled indoor unit. 00 L08 No Setting of indoor unit address. 0 L09 No Setting of indoor unit capacity. 0 L0 No Setting of outdoor unit capacity. 0 L Mis-wiring of group control wire. (Espacio) 0 L Discord of indoor unit?s capacity. (Multi) 0 L Poor setting of indoor unit's type. 06 L Discord of power frequency. (0-60Hz) 07 L Defective double duct bearing. P0 Abnormal indoor fan motor. 6 P0 Actuation of outdoor fan motor - protective thermostats for CM and AC. 7 P0 High discharge temperature of compressor. 8 P0 Actuation of high refrigerant pressure switch. 9 P0 Reversed phase of the power source. P09 Poor connection of ceiling panel connector for indoor unit. P0 Actuation of indoor unit float switch. Description 9 P No refrigerant gas. P7 Abnormal discharge gas temperature from compressor. P8 Abnormal discharge gas temperature from compressor. P0 Abnormally high refrigerant gas pressure. P Abnormal pressure difference in compressor oil. P0 P Abnormal sub indoor units in group control. (Centralized processing control detected the abnormality.) Abnormal group control.